Summary
SSA-354112: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.2
Notes
Summary
SCALANCE M-800 family before V8.2 is affected by multiple vulnerabilities.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE M-800 family before V8.2 is affected by multiple vulnerabilities.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-354112: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.2 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-354112.html" }, { "category": "self", "summary": "SSA-354112: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-354112.json" } ], "title": "SSA-354112: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.2", "tracking": { "current_release_date": "2024-11-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-354112", "initial_release_date": "2024-11-12T00:00:00Z", "revision_history": [ { "date": "2024-11-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)", "product_id": "6", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)", "product_id": "7", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "8", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } } ], "category": "product_name", "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "9", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2)", "product_id": "10", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2FA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "11", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)", "product_id": "12", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "13", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "14", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "15", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "16", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1)", "product_id": "17", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA10-2AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1)", "product_id": "18", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA10-2BA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "19", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1)", "product_id": "20", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA10-3AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1)", "product_id": "21", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA10-3BA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1)", "product_id": "22", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3FA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "23", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "24", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)", "product_id": "25", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV8.2", "product": { "name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)", "product_id": "26", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-3506", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds (OOB) memory access flaw was found in fs/f2fs/node.c in the f2fs module in the Linux kernel in versions before 5.12.0-rc4. A bounds check failure allows a local attacker to gain access to out-of-bounds memory leading to a system crash or a leak of internal kernel information. The highest threat from this vulnerability is to system availability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2021-3506" }, { "cve": "CVE-2023-28450", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Dnsmasq before 2.90. The default maximum EDNS.0 UDP packet size was set to 4096 but should be 1232 because of DNS Flag Day 2020.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2023-28450" }, { "cve": "CVE-2023-49441", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "dnsmasq 2.9 is vulnerable to Integer Overflow via forward_query.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2023-49441" }, { "cve": "CVE-2024-2511", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Issue summary: Some non-default TLS server configurations can cause unbounded memory growth when processing TLSv1.3 sessions\r\nImpact summary: An attacker may exploit certain server configurations to trigger unbounded memory growth that would lead to a Denial of Service This problem can occur in TLSv1.3 if the non-default SSL_OP_NO_TICKET option is being used (but not if early_data support is also configured and the default anti-replay protection is in use). In this case, under certain conditions, the session cache can get into an incorrect state and it will fail to flush properly as it fills. The session cache will continue to grow in an unbounded manner. A malicious client could deliberately create the scenario for this failure to force a Denial of Service. It may also happen by accident in normal operation. This issue only affects TLS servers supporting TLSv1.3. It does not affect TLS clients. The FIPS modules in 3.2, 3.1 and 3.0 are not affected by this issue. OpenSSL 1.0.2 is also not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-2511" }, { "cve": "CVE-2024-4603", "cwe": { "id": "CWE-834", "name": "Excessive Iteration" }, "notes": [ { "category": "summary", "text": "Issue summary: Checking excessively long DSA keys or parameters may be very slow. Impact summary: Applications that use the functions EVP_PKEY_param_check() or EVP_PKEY_public_check() to check a DSA public key or DSA parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. The functions EVP_PKEY_param_check() or EVP_PKEY_public_check() perform various checks on DSA parameters. Some of those computations take a long time if the modulus (`p` parameter) is too large. Trying to use a very large modulus is slow and OpenSSL will not allow using public keys with a modulus which is over 10,000 bits in length for signature verification. However the key and parameter check functions do not limit the modulus size when performing the checks. An application that calls EVP_PKEY_param_check() or EVP_PKEY_public_check() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial of Service attack. These functions are not called by OpenSSL itself on untrusted DSA keys so only applications that directly call these functions may be vulnerable. Also vulnerable are the OpenSSL pkey and pkeyparam command line applications when using the `-check` option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-4603" }, { "cve": "CVE-2024-4741", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Issue summary: Calling the OpenSSL API function SSL_free_buffers may cause memory to be accessed that was previously freed in some situations", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-4741" }, { "cve": "CVE-2024-5594", "cwe": { "id": "CWE-117", "name": "Improper Output Neutralization for Logs" }, "notes": [ { "category": "summary", "text": "control channel: refuse control channel messages with nonprintable characters in them. Security scope: a malicious openvpn peer can send garbage to openvpn log, or cause high CPU load", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-5594" }, { "cve": "CVE-2024-26306", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "iPerf3 before 3.17, when used with OpenSSL before 3.2.0 as a server with RSA authentication, allows a timing side channel in RSA decryption operations. This side channel could be sufficient for an attacker to recover credential plaintext. It requires the attacker to send a large number of messages for decryption, as described in \"Everlasting ROBOT: the Marvin Attack\" by Hubert Kario.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-26306" }, { "cve": "CVE-2024-26925", "cwe": { "id": "CWE-667", "name": "Improper Locking" }, "notes": [ { "category": "summary", "text": "In the Linux kernel, the following vulnerability has been resolved: netfilter: nf_tables: release mutex after nft_gc_seq_end from abort path The commit mutex should not be released during the critical section between nft_gc_seq_begin() and nft_gc_seq_end(), otherwise, async GC worker could collect expired objects and get the released commit lock within the same GC sequence. nf_tables_module_autoload() temporarily releases the mutex to load module dependencies, then it goes back to replay the transaction again. Move it at the end of the abort phase after nft_gc_seq_end() is called.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-26925" }, { "cve": "CVE-2024-28882", "cwe": { "id": "CWE-772", "name": "Missing Release of Resource after Effective Lifetime" }, "notes": [ { "category": "summary", "text": "OpenVPN from 2.6.0 through 2.6.10 in a server role accepts multiple exit notifications from authenticated clients which will extend the validity of a closing session", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-28882" }, { "cve": "CVE-2024-50557", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate input in configuration fields of the iperf functionality. This could allow an unauthenticated remote attacker to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-50557" }, { "cve": "CVE-2024-50558", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "Affected devices improperly manage access control for read-only users. This could allow an attacker to cause a temporary denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-50558" }, { "cve": "CVE-2024-50559", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the filenames of the certificate. This could allow an authenticated remote attacker to append arbitrary values which will lead to compromise of integrity of the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-50559" }, { "cve": "CVE-2024-50560", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.1, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-50560" }, { "cve": "CVE-2024-50561", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize the filenames before uploading. This could allow an authenticated remote attacker to compromise of integrity of the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-50561" }, { "cve": "CVE-2024-50572", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.2 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "11", "10", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26" ] } ], "title": "CVE-2024-50572" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.