Vulnerability from cvelistv5 – Published: 2024-09-25 08:04 – Updated: 2024-09-25 14:02
VLAI?
EPSS
Title
CODESYS: web server vulnerable to DoS
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
Severity ?
7.5 (High)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.14.0.0
(semver)
|
||
|
|
||||
Credits
ABB
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_control_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:44:03.391474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:02:28.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:33:10.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"source": {
"advisory": "VDE-2024-057",
"defect": [
"CERT@VDE#641681"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: web server vulnerable to DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-8175",
"datePublished": "2024-09-25T08:04:23.196Z",
"dateReserved": "2024-08-26T09:58:34.794Z",
"dateUpdated": "2024-09-25T14:02:28.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"An unauthenticated remote attacker can\\u00a0causes the CODESYS web server to access invalid memory which results in a DoS.\"}, {\"lang\": \"es\", \"value\": \"Un atacante remoto no autenticado puede provocar que el servidor web CODESYS acceda a una memoria no v\\u00e1lida, lo que resulta en un DoS.\"}]",
"id": "CVE-2024-8175",
"lastModified": "2024-09-26T13:32:02.803",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"info@cert.vde.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2024-09-25T08:15:04.727",
"references": "[{\"url\": \"https://cert.vde.com/en/advisories/VDE-2024-057\", \"source\": \"info@cert.vde.com\"}, {\"url\": \"https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download=\", \"source\": \"info@cert.vde.com\"}]",
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"info@cert.vde.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-754\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-8175\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2024-09-25T08:15:04.727\",\"lastModified\":\"2024-09-26T13:32:02.803\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto no autenticado puede provocar que el servidor web CODESYS acceda a una memoria no v\u00e1lida, lo que resulta en un DoS.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2024-057\",\"source\":\"info@cert.vde.com\"},{\"url\":\"https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download=\",\"source\":\"info@cert.vde.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-8175\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-25T13:44:03.391474Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_empc-a\\\\/imx6_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*\"], \"vendor\": \"codesys\", \"product\": \"runtime_toolkit\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:codesys:control_rte_\\\\(for_beckhoff_cx\\\\)_sl:*:*:*:*:*:*:*:*\"], \"vendor\": \"codesys\", \"product\": \"control_rte_\\\\(for_beckhoff_cx\\\\)_sl\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*\"], \"vendor\": \"codesys\", \"product\": \"virtual_control_sl\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*\", \"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*\"], \"vendor\": \"codesys\", \"product\": \"runtime_toolkit\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-25T13:53:18.029Z\"}}], \"cna\": {\"title\": \"CODESYS: web server vulnerable to DoS\", \"source\": {\"defect\": [\"CERT@VDE#641681\"], \"advisory\": \"VDE-2024-057\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"ABB\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for BeagleBone SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for emPC-A/iMX6 SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for IOT2000 SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for Linux ARM SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for Linux SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for PFC100 SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for PFC200 SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for PLCnext SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for Raspberry Pi SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control for WAGO Touch Panels 600 SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control RTE (for Beckhoff CX) SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control RTE (SL)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Control Win (SL)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Embedded Target Visu Toolkit\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS HMI (SL)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Remote Target Visu Toolkit\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Runtime Toolkit\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.5.20.30\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"CODESYS\", \"product\": \"CODESYS Virtual Control SL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.14.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2024-057\"}, {\"url\": \"https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download=\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An unauthenticated remote attacker can\\u00a0causes the CODESYS web server to access invalid memory which results in a DoS.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-754\", \"description\": \"CWE-754 Improper Check for Unusual or Exceptional Conditions\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2024-09-25T13:33:10.408Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-8175\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-25T14:02:28.368Z\", \"dateReserved\": \"2024-08-26T09:58:34.794Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2024-09-25T08:04:23.196Z\", \"assignerShortName\": \"CERTVDE\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CVE-2024-8175
Vulnerability from csaf_festosecokg - Published: 2026-02-26 08:00 - Updated: 2026-02-26 08:00Summary
Several CODESYS vulnerabilities in Festo Automation Suite
Notes
Summary
Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.
This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.
Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.
Impact
The vulnerabilities covered by this advisory have a broad range of impacts ranging from denial-of-service to disclosure or manipulation/deletion of information.
Remediation
Download and install Festo Automation Suite version 2.8.0.138 and download the latest, patched version of Codesys directly from the official Codesys website.
Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied.
Regularly monitor Codesys security advisories and apply updates promptly.
Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.
General recommendations
As part of a security strategy, Festo recommends the following general defense measures to reduce the risk of exploits:
- Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.
- Use firewalls to protect and separate the control system network from other networks.
- Use VPN (Virtual Private Networks) tunnels if remote access is required.
- Activate and apply user management and password features.
- Use encrypted communication links.
- Limit the access to both development and control system by physical means, operating system features, etc.
- Protect both development and control systems by using up-to-date virus detection solutions.
Festo strongly recommends minimizing and protecting network access to connected devices with state-of-the-art techniques and processes.
To ensure secure operation follow the recommendations in the product manuals.
Disclaimer
Festo assumes no liability whatsoever for indirect, collateral, accidental or consequential losses that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided free of charge and on good faith by Festo. Insofar as permissible by law, however, none of this information shall establish any warranty, guarantee, commitment, or liability on the part of Festo.
Note: In no case does this information release the operator or responsible person from the obligation to check the effect on his system or installation before using the information and, in the event of negative consequences, not to use the information.
In addition, the actual general terms, and conditions for delivery, payment and software use of Festo, available under http://www.festo.com and the special provisions for the use of Festo Security Advisory available at https://www.festo.com/psirt shall apply.
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination and support with this publication",
"urls": [
"https://certvde.com"
]
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
"text": "Critical"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.\n\nThis change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.\n\nPlease ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.",
"title": "Summary"
},
{
"category": "description",
"text": "The vulnerabilities covered by this advisory have a broad range of impacts ranging from denial-of-service to disclosure or manipulation/deletion of information.",
"title": "Impact"
},
{
"category": "description",
"text": "Download and install Festo Automation Suite version 2.8.0.138 and download the latest, patched version of Codesys directly from the official Codesys website.\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\nRegularly monitor Codesys security advisories and apply updates promptly.\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"title": "Remediation"
},
{
"category": "general",
"text": "As part of a security strategy, Festo recommends the following general defense measures to reduce the risk of exploits: \n- Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\n- Use firewalls to protect and separate the control system network from other networks.\n- Use VPN (Virtual Private Networks) tunnels if remote access is required.\n- Activate and apply user management and password features.\n- Use encrypted communication links.\n- Limit the access to both development and control system by physical means, operating system features, etc. \n- Protect both development and control systems by using up-to-date virus detection solutions.\n\nFesto strongly recommends minimizing and protecting network access to connected devices with state-of-the-art techniques and processes. \nTo ensure secure operation follow the recommendations in the product manuals.",
"title": "General recommendations"
},
{
"category": "legal_disclaimer",
"text": "Festo assumes no liability whatsoever for indirect, collateral, accidental or consequential losses that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided free of charge and on good faith by Festo. Insofar as permissible by law, however, none of this information shall establish any warranty, guarantee, commitment, or liability on the part of Festo.\n\nNote: In no case does this information release the operator or responsible person from the obligation to check the effect on his system or installation before using the information and, in the event of negative consequences, not to use the information.\n\nIn addition, the actual general terms, and conditions for delivery, payment and software use of Festo, available under http://www.festo.com and the special provisions for the use of Festo Security Advisory available at https://www.festo.com/psirt shall apply.",
"title": "Disclaimer"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@festo.com",
"name": "Festo SE \u0026 Co. KG",
"namespace": "https://www.festo.com"
},
"references": [
{
"category": "external",
"summary": "For further security-related issues in Festo products please contact the Festo Product Security Incident Response Team (PSIRT)",
"url": "https://www.festo.com/psirt"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories",
"url": "https://certvde.com/en/advisories/vendor/festo/"
},
{
"category": "self",
"summary": "FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF",
"url": "https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json"
},
{
"category": "self",
"summary": "FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML",
"url": "https://certvde.com/en/advisories/VDE-2025-108"
},
{
"category": "external",
"summary": "https://nvd.nist.gov/vuln/detail/CVE-2025-2595",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2595"
}
],
"title": "Several CODESYS vulnerabilities in Festo Automation Suite",
"tracking": {
"aliases": [
"VDE-2025-108"
],
"current_release_date": "2026-02-26T08:00:00.000Z",
"generator": {
"date": "2026-02-25T19:13:41.744Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.43"
}
},
"id": "FSA-202601",
"initial_release_date": "2026-02-26T08:00:00.000Z",
"revision_history": [
{
"date": "2026-02-26T08:00:00.000Z",
"number": "1.0.0",
"summary": "Initial version"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003c2.8.0.138",
"product": {
"name": "Festo Automation Suite \u003c2.8.0.138",
"product_id": "CSAFPID-51001",
"product_identification_helper": {
"model_numbers": [
"8074657"
],
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8074657"
},
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Website",
"uri": "https://www.festo.com/us/en/a/8074657/?q=8074657%7E%3AfestoSortOrderScored"
}
]
}
}
},
{
"category": "product_version",
"name": "2.8.0.138",
"product": {
"name": "Festo Automation Suite 2.8.0.138",
"product_id": "CSAFPID-52001",
"product_identification_helper": {
"cpe": "cpe:2.3:a:festo:festo_automation_suite:2.8.0.138*:*:*:*:*:*:*:*",
"model_numbers": [
"8074657"
],
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8074657"
},
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Website",
"uri": "https://www.festo.com/us/en/a/8074657/?q=8074657%7E%3AfestoSortOrderScored"
}
]
}
}
},
{
"category": "product_version",
"name": "2.8.0.137",
"product": {
"name": "Festo Automation Suite 2.8.0.137",
"product_id": "CSAFPID-51002",
"product_identification_helper": {
"cpe": "cpe:2.3:a:festo:festo_automation_suite:2.8.0.138*:*:*:*:*:*:*:*",
"model_numbers": [
"8074657"
],
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Wesite",
"uri": "https://www.festo.com/us/en/a/8074657/?q=8074657%7E%3AfestoSortOrderScored"
}
]
}
}
}
],
"category": "product_name",
"name": "Festo Automation Suite"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "FESTO"
},
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "3.5.21.20",
"product": {
"name": "CODESYS Development System 3.5.21.20",
"product_id": "CSAFPID-52002",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.21.20*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version",
"name": "3.0",
"product": {
"name": "CODESYS Development System 3.0",
"product_id": "CSAFPID-51003",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version",
"name": "3.5.16.10",
"product": {
"name": "CODESYS Development System 3.5.16.10",
"product_id": "CSAFPID-51004",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*"
}
}
}
],
"category": "product_name",
"name": "CODESYS Development System"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "CODESYS"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
],
"summary": "Affected Products."
}
],
"relationships": [
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite \u003c2.8.0.138 installed with CODESYS Development System 3.0",
"product_id": "CSAFPID-31001",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-51001",
"relates_to_product_reference": "CSAFPID-51003"
},
{
"category": "external_component_of",
"full_product_name": {
"name": "CODESYS Development System 3.5.21.20 external component of Festo Automation Suite 2.8.0.138",
"product_id": "CSAFPID-32001",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.21.20*:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-52002",
"relates_to_product_reference": "CSAFPID-52001"
},
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite \u003c2.8.0.138 installed with CODESYS Development System 3.5.16.10",
"product_id": "CSAFPID-31002",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-51001",
"relates_to_product_reference": "CSAFPID-51004"
},
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite 2.8.0.137 installed with CODESYS Development System 3.0",
"product_id": "CSAFPID-31003",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-51002",
"relates_to_product_reference": "CSAFPID-51003"
},
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite 2.8.0.137 installed with CODESYS Development System 3.5.16.10",
"product_id": "CSAFPID-31004",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-51002",
"relates_to_product_reference": "CSAFPID-51004"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-2595",
"cwe": {
"id": "CWE-425",
"name": "Direct Request (\u0027Forced Browsing\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can bypass the user management in CODESYS Visualization and read visualization template files or static elements by means of forced browsing.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\n\nDownload the latest, patched version of Codesys directly from the official Codesys website.\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\nRegularly monitor Codesys security advisories and apply updates promptly.\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-2595"
},
{
"cve": "CVE-2010-5250",
"cwe": {
"id": "CWE-426",
"name": "Untrusted Search Path"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Untrusted search path vulnerability in the pthread_win32_process_attach_np function in pthreadGC2.dll in Pthreads-win32 2.8.0 allows local users to gain privileges via a Trojan horse quserex.dll file in the current working directory. NOTE: some of these details are obtained from third party information.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v2": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"environmentalScore": 6.9,
"integrityImpact": "COMPLETE",
"temporalScore": 6.9,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2010-5250"
},
{
"cve": "CVE-2017-3735",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2017-3735"
},
{
"cve": "CVE-2018-0739",
"cwe": {
"id": "CWE-674",
"name": "Uncontrolled Recursion"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Constructed ASN.1 types with a recursive definition (such as can be found in PKCS7) could eventually exceed the stack given malicious input with excessive recursion. This could result in a Denial Of Service attack. There are no such structures used within SSL/TLS that come from untrusted sources so this is considered safe. Fixed in OpenSSL 1.1.0h (Affected 1.1.0-1.1.0g). Fixed in OpenSSL 1.0.2o (Affected 1.0.2b-1.0.2n).",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2018-0739"
},
{
"cve": "CVE-2018-10612",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2018-10612"
},
{
"cve": "CVE-2018-20025",
"cwe": {
"id": "CWE-330",
"name": "Use of Insufficiently Random Values"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2018-20025"
},
{
"cve": "CVE-2018-20026",
"cwe": {
"id": "CWE-923",
"name": "Improper Restriction of Communication Channel to Intended Endpoints"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2018-20026"
},
{
"cve": "CVE-2019-13532",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-13532"
},
{
"cve": "CVE-2019-13538",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.6,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 8.6,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-13538"
},
{
"cve": "CVE-2019-13542",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-13542"
},
{
"cve": "CVE-2019-13548",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-13548"
},
{
"cve": "CVE-2019-18858",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-18858"
},
{
"cve": "CVE-2019-19789",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-19789"
},
{
"cve": "CVE-2019-5105",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System).",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-5105"
},
{
"cve": "CVE-2019-9008",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-9008"
},
{
"cve": "CVE-2019-9009",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-9009"
},
{
"cve": "CVE-2019-9010",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-9010"
},
{
"cve": "CVE-2019-9011",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), an attacker can identify valid usernames.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-9011"
},
{
"cve": "CVE-2019-9012",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-9012"
},
{
"cve": "CVE-2019-9013",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2019-9013"
},
{
"cve": "CVE-2020-10245",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-10245"
},
{
"cve": "CVE-2020-12067",
"cwe": {
"id": "CWE-640",
"name": "Weak Password Recovery Mechanism for Forgotten Password"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user\u0027s password may be changed by an attacker without knowledge of the current password.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-12067"
},
{
"cve": "CVE-2020-12068",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-12068"
},
{
"cve": "CVE-2020-12069",
"cwe": {
"id": "CWE-916",
"name": "Use of Password Hash With Insufficient Computational Effort"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-12069"
},
{
"cve": "CVE-2020-14509",
"cwe": {
"id": "CWE-805",
"name": "Buffer Access with Incorrect Length Value"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-14509"
},
{
"cve": "CVE-2020-14513",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-14513"
},
{
"cve": "CVE-2020-14515",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-14515"
},
{
"cve": "CVE-2020-14517",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-14517"
},
{
"cve": "CVE-2020-14519",
"cwe": {
"id": "CWE-346",
"name": "Origin Validation Error"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-14519"
},
{
"cve": "CVE-2020-15806",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-15806"
},
{
"cve": "CVE-2020-16233",
"cwe": {
"id": "CWE-404",
"name": "Improper Resource Shutdown or Release"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-16233"
},
{
"cve": "CVE-2020-7052",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-7052"
},
{
"cve": "CVE-2021-21863",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21863"
},
{
"cve": "CVE-2021-21864",
"cwe": {
"id": "CWE-50",
"name": "Path Equivalence: \u0027//multiple/leading/slash\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21864"
},
{
"cve": "CVE-2021-21865",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21865"
},
{
"cve": "CVE-2021-21866",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21866"
},
{
"cve": "CVE-2021-21867",
"cwe": {
"id": "CWE-50",
"name": "Path Equivalence: \u0027//multiple/leading/slash\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21867"
},
{
"cve": "CVE-2021-21868",
"cwe": {
"id": "CWE-50",
"name": "Path Equivalence: \u0027//multiple/leading/slash\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21868"
},
{
"cve": "CVE-2021-21869",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-21869"
},
{
"cve": "CVE-2021-29239",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-29239"
},
{
"cve": "CVE-2021-29240",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-29240"
},
{
"cve": "CVE-2021-29241",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-29241"
},
{
"cve": "CVE-2021-29242",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-29242"
},
{
"cve": "CVE-2021-30186",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-30186"
},
{
"cve": "CVE-2021-30187",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-30187"
},
{
"cve": "CVE-2021-30188",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-30188"
},
{
"cve": "CVE-2021-30190",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-30190"
},
{
"cve": "CVE-2021-30195",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-30195"
},
{
"cve": "CVE-2021-33485",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-33485"
},
{
"cve": "CVE-2021-33486",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-33486"
},
{
"cve": "CVE-2021-34593",
"cwe": {
"id": "CWE-75",
"name": "Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-34593"
},
{
"cve": "CVE-2021-34595",
"cwe": {
"id": "CWE-823",
"name": "Use of Out-of-range Pointer Offset"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-34595"
},
{
"cve": "CVE-2021-34596",
"cwe": {
"id": "CWE-82",
"name": "Improper Neutralization of Script in Attributes of IMG Tags in a Web Page"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-34596"
},
{
"cve": "CVE-2021-36763",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-36763"
},
{
"cve": "CVE-2021-36764",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-36764"
},
{
"cve": "CVE-2021-36765",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2021-36765"
},
{
"cve": "CVE-2022-1965",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-1965"
},
{
"cve": "CVE-2022-1989",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-1989"
},
{
"cve": "CVE-2022-22508",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 4.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 4.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22508"
},
{
"cve": "CVE-2022-22513",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22513"
},
{
"cve": "CVE-2022-22514",
"cwe": {
"id": "CWE-822",
"name": "Untrusted Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22514"
},
{
"cve": "CVE-2022-22515",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22515"
},
{
"cve": "CVE-2022-22516",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22516"
},
{
"cve": "CVE-2022-22517",
"cwe": {
"id": "CWE-33",
"name": "Path Traversal: \u0027....\u0027 (Multiple Dot)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22517"
},
{
"cve": "CVE-2022-22519",
"cwe": {
"id": "CWE-12",
"name": "ASP.NET Misconfiguration: Missing Custom Error Page"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-22519"
},
{
"cve": "CVE-2022-30791",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-30791"
},
{
"cve": "CVE-2022-30792",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-30792"
},
{
"cve": "CVE-2022-31805",
"cwe": {
"id": "CWE-523",
"name": "Unprotected Transport of Credentials"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-31805"
},
{
"cve": "CVE-2022-31806",
"cwe": {
"id": "CWE-1188",
"name": "Initialization of a Resource with an Insecure Default"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-31806"
},
{
"cve": "CVE-2022-32136",
"cwe": {
"id": "CWE-82",
"name": "Improper Neutralization of Script in Attributes of IMG Tags in a Web Page"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32136"
},
{
"cve": "CVE-2022-32137",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32137"
},
{
"cve": "CVE-2022-32138",
"cwe": {
"id": "CWE-194",
"name": "Unexpected Sign Extension"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32138"
},
{
"cve": "CVE-2022-32139",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32139"
},
{
"cve": "CVE-2022-32140",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32140"
},
{
"cve": "CVE-2022-32141",
"cwe": {
"id": "CWE-126",
"name": "Buffer Over-read"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32141"
},
{
"cve": "CVE-2022-32142",
"cwe": {
"id": "CWE-823",
"name": "Use of Out-of-range Pointer Offset"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32142"
},
{
"cve": "CVE-2022-32143",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-32143"
},
{
"cve": "CVE-2022-4046",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-4046"
},
{
"cve": "CVE-2022-4048",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Inadequate Encryption Strength in CODESYS Development System V3 versions prior to V3.5.18.40 allows an unauthenticated local attacker to access and manipulate code of the encrypted boot application.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.7,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.7,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-4048"
},
{
"cve": "CVE-2022-4224",
"cwe": {
"id": "CWE-1188",
"name": "Initialization of a Resource with an Insecure Default"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u00c2 could utilize this vulnerability to read and modify system files and OS resources or DoS the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-4224"
},
{
"cve": "CVE-2022-47378",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47378"
},
{
"cve": "CVE-2022-47379",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into memory which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47379"
},
{
"cve": "CVE-2022-47380",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based\u00c2 out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47380"
},
{
"cve": "CVE-2022-47381",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47381"
},
{
"cve": "CVE-2022-47383",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47383"
},
{
"cve": "CVE-2022-47384",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47384"
},
{
"cve": "CVE-2022-47385",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47385"
},
{
"cve": "CVE-2022-47386",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47386"
},
{
"cve": "CVE-2022-47387",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47387"
},
{
"cve": "CVE-2022-47388",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47388"
},
{
"cve": "CVE-2022-47389",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47389"
},
{
"cve": "CVE-2022-47390",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47390"
},
{
"cve": "CVE-2022-47391",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products in multiple versions an unauthorized, remote attacker may use a improper input validation vulnerability to read from invalid addresses leading to a denial of service.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47391"
},
{
"cve": "CVE-2022-47392",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a improper input validation vulnerability in the CmpApp/CmpAppBP/CmpAppForce Components of multiple CODESYS products in multiple versions to read from an invalid address which can lead\u00c2 to a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47392"
},
{
"cve": "CVE-2022-47393",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in multiple versions of multiple CODESYS products to force a denial-of-service situation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47393"
},
{
"cve": "CVE-2023-3662",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context .",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-3662"
},
{
"cve": "CVE-2023-3663",
"cwe": {
"id": "CWE-940",
"name": "Improper Verification of Source of a Communication Channel"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-3663"
},
{
"cve": "CVE-2023-3669",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"environmentalScore": 3.3,
"environmentalSeverity": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 3.3,
"temporalSeverity": "LOW",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-3669"
},
{
"cve": "CVE-2023-3670",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Development System 3.5.9.0 to\u00c2 3.5.17.0 and\u00c2 CODESYS Scripting\u00c2 4.0.0.0 to\u00c2 4.1.0.0 unsafe directory permissions would allow an attacker with local access to the workstation to place potentially harmful and disguised scripts that could be executed by legitimate users.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-3670"
},
{
"cve": "CVE-2023-37545",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546,\u00c2 CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37545"
},
{
"cve": "CVE-2023-37546",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37546"
},
{
"cve": "CVE-2023-37547",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37547"
},
{
"cve": "CVE-2023-37548",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00c2 CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37548"
},
{
"cve": "CVE-2023-37549",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00c2 CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37549"
},
{
"cve": "CVE-2023-37550",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00c2 CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37550"
},
{
"cve": "CVE-2023-37551",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37551"
},
{
"cve": "CVE-2023-37552",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00c2 CVE-2023-37554,\u00c2 CVE-2023-37555 and\u00c2 CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37552"
},
{
"cve": "CVE-2023-37553",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00c2 CVE-2023-37552,\u00c2 CVE-2023-37554,\u00c2 CVE-2023-37555 and\u00c2 CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37553"
},
{
"cve": "CVE-2023-37554",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00c2 CVE-2023-37552,\u00c2 CVE-2023-37553, CVE-2023-37555 and\u00c2 CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37554"
},
{
"cve": "CVE-2023-37555",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00c2 CVE-2023-37552,\u00c2 CVE-2023-37553,\u00c2 CVE-2023-37554 and\u00c2 CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37555"
},
{
"cve": "CVE-2023-37556",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00c2 CVE-2023-37552,\u00c2 CVE-2023-37553,\u00c2 CVE-2023-37554 and CVE-2023-37555.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37556"
},
{
"cve": "CVE-2023-37557",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37557"
},
{
"cve": "CVE-2023-37558",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37558"
},
{
"cve": "CVE-2023-37559",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-37559"
},
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-3935"
},
{
"cve": "CVE-2023-49675",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability.\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-49675"
},
{
"cve": "CVE-2023-49676",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated local attacker may trick a user to open corrupted project files to crash the system due to use after free vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-49676"
},
{
"cve": "CVE-2023-6357",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2023-6357"
},
{
"cve": "CVE-2024-5000",
"cwe": {
"id": "CWE-13",
"name": "ASP.NET Misconfiguration: Password in Configuration File"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can use a\u00c2 malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2024-5000"
},
{
"cve": "CVE-2024-8175",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can\u00c2 causes the CODESYS web server to access invalid memory which results in a DoS.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2024-8175"
},
{
"cve": "CVE-2025-0694",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.6,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-0694"
},
{
"cve": "CVE-2025-1468",
"cwe": {
"id": "CWE-203",
"name": "Observable Discrepancy"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-1468"
},
{
"cve": "CVE-2025-41658",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 5.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 5.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-41658"
},
{
"cve": "CVE-2025-41659",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.3,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-41659"
},
{
"cve": "CVE-2020-11023",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In jQuery versions greater than or equal to 1.0.3 and before 3.5.0, passing HTML containing \u003coption\u003e elements from untrusted sources - even after sanitizing it - to one of jQuery\u0027s DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code. This problem is patched in jQuery 3.5.0.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.9,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 6.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2020-11023"
},
{
"cve": "CVE-2022-47382",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead\u00c2 to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2022-47382"
}
]
}
GHSA-V6P4-R397-Q442
Vulnerability from github – Published: 2024-09-25 09:30 – Updated: 2024-09-25 15:31
VLAI?
Details
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
Severity ?
7.5 (High)
{
"affected": [],
"aliases": [
"CVE-2024-8175"
],
"database_specific": {
"cwe_ids": [
"CWE-754"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-09-25T08:15:04Z",
"severity": "HIGH"
},
"details": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS.",
"id": "GHSA-v6p4-r397-q442",
"modified": "2024-09-25T15:31:12Z",
"published": "2024-09-25T09:30:46Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-8175"
},
{
"type": "WEB",
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"type": "WEB",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
WID-SEC-W-2024-2208
Vulnerability from csaf_certbund - Published: 2024-09-23 22:00 - Updated: 2025-01-07 23:00Summary
CODESYS: Schwachstelle ermöglicht Denial of Service
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
CODESYS ist eine herstellerunabhängige Automatisierungssoftware für die Entwicklung von Steuerungsanwendungen in der industriellen Automatisierung.
Angriff
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in CODESYS ausnutzen, um einen Denial of Service Angriff durchzuführen.
Betroffene Betriebssysteme
- Sonstiges
{
"document": {
"aggregate_severity": {
"text": "mittel"
},
"category": "csaf_base",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "de-DE",
"notes": [
{
"category": "legal_disclaimer",
"text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen."
},
{
"category": "description",
"text": "CODESYS ist eine herstellerunabh\u00e4ngige Automatisierungssoftware f\u00fcr die Entwicklung von Steuerungsanwendungen in der industriellen Automatisierung.",
"title": "Produktbeschreibung"
},
{
"category": "summary",
"text": "Ein entfernter, anonymer Angreifer kann eine Schwachstelle in CODESYS ausnutzen, um einen Denial of Service Angriff durchzuf\u00fchren.",
"title": "Angriff"
},
{
"category": "general",
"text": "- Sonstiges",
"title": "Betroffene Betriebssysteme"
}
],
"publisher": {
"category": "other",
"contact_details": "csaf-provider@cert-bund.de",
"name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"namespace": "https://www.bsi.bund.de"
},
"references": [
{
"category": "self",
"summary": "WID-SEC-W-2024-2208 - CSAF Version",
"url": "https://wid.cert-bund.de/.well-known/csaf/white/2024/wid-sec-w-2024-2208.json"
},
{
"category": "self",
"summary": "WID-SEC-2024-2208 - Portal Version",
"url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2024-2208"
},
{
"category": "external",
"summary": "CODESYS Security Advisory vom 2024-09-23",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
},
{
"category": "external",
"summary": "ABB Security Advisory vom 2025-01-07",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011377\u0026LanguageCode=en\u0026DocumentPartId=CSAF\u0026Action=Launch"
}
],
"source_lang": "en-US",
"title": "CODESYS: Schwachstelle erm\u00f6glicht Denial of Service",
"tracking": {
"current_release_date": "2025-01-07T23:00:00.000+00:00",
"generator": {
"date": "2025-01-08T10:37:40.968+00:00",
"engine": {
"name": "BSI-WID",
"version": "1.3.10"
}
},
"id": "WID-SEC-W-2024-2208",
"initial_release_date": "2024-09-23T22:00:00.000+00:00",
"revision_history": [
{
"date": "2024-09-23T22:00:00.000+00:00",
"number": "1",
"summary": "Initiale Fassung"
},
{
"date": "2025-01-07T23:00:00.000+00:00",
"number": "2",
"summary": "Neue Updates aufgenommen"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.8.0",
"product": {
"name": "ABB AC-500 \u003c3.8.0",
"product_id": "T040044"
}
},
{
"category": "product_version",
"name": "3.8.0",
"product": {
"name": "ABB AC-500 3.8.0",
"product_id": "T040044-fixed",
"product_identification_helper": {
"cpe": "cpe:/h:abb:ac-500:3.8.0"
}
}
}
],
"category": "product_name",
"name": "AC-500"
}
],
"category": "vendor",
"name": "ABB"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS CODESYS \u003c4.14.0.0",
"product_id": "T037805"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS CODESYS 4.14.0.0",
"product_id": "T037805-fixed",
"product_identification_helper": {
"cpe": "cpe:/a:codesys:codesys:4.14.0.0"
}
}
},
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS CODESYS \u003c3.5.20.30",
"product_id": "T037806"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS CODESYS 3.5.20.30",
"product_id": "T037806-fixed",
"product_identification_helper": {
"cpe": "cpe:/a:codesys:codesys:3.5.20.30"
}
}
}
],
"category": "product_name",
"name": "CODESYS"
}
],
"category": "vendor",
"name": "CODESYS"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-8175",
"notes": [
{
"category": "description",
"text": "Es besteht eine Schwachstelle in CODESYS. Dieser Fehler besteht aufgrund einer unsachgem\u00e4\u00dfen Behandlung von R\u00fcckgabewerten bei der Verarbeitung von TLS-Paketen, was zu einem ung\u00fcltigen Speicherzugriff f\u00fchrt. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen, der den Webserver zum Absturz bringt, wenn er mit speziell gestalteten TLS-Paketen angegriffen wird."
}
],
"product_status": {
"known_affected": [
"T037805",
"T037806",
"T040044"
]
},
"release_date": "2024-09-23T22:00:00.000+00:00",
"title": "CVE-2024-8175"
}
]
}
3ADR011377
Vulnerability from csaf_abb - Published: 2025-01-07 00:30 - Updated: 2025-01-07 00:30Summary
AC500 V3 Multiple vulnerabilities
Notes
Summary
An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory.
An attacker who successfully exploited these vulnerabilities could call shell functions (CVE-2023-6357),
crash the PLC (CVE-2024-5000), crash the web server of the PLC (CVE-2024-8175), grant read access to
files (CVE-2024-12429) or enable command execution (CVE-2024-12430).
The vulnerabilities CVE-2023-6357, CVE-2024-12429 and CVE-2024-12430 require successful authentication.
General security recommendations
For any installation of software-related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:
– Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls
and separate them from any general-purpose network (e.g. office or home networks).
– Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.
– Never connect programming software or computers containing programming software to any network other than the network for the devices that it is intended for.
– Scan all data imported into your environment before use to detect potential malware infections.
– Minimize network exposure for all applications and endpoints to ensure that they are not accessible
from the Internet unless they are designed for such exposure and the intended use requires such.
– Ensure all nodes are always up to date in terms of installed software, operating system, and firmware
patches as well as anti-virus and firewall.
– When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices
Support
For additional instructions and support please contact your local ABB service organization. For contact
information, see www.abb.com/contactcenters.
Information about ABB’s cyber security program and capabilities can be found at www.abb.com/cybersecurity.
Notice
The information in this document is subject to change without notice, and should not be construed as a
commitment by ABB.
ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a
particular purpose, for the information contained in this document, and assumes no responsibility for
any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of
this document, or from the use of any hardware or software described in this document, even if ABB or
its suppliers have been advised of the possibility of such damages.
This document and parts hereof must not be reproduced or copied without written permission from
ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.
All rights to registrations and trademarks reside with their respective owners.
Workarounds
Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality.
ABB has tested the following workarounds. Although these workarounds will not correct the underlying
vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is
identified below as “Impact of workaround”.
To exploit the vulnerabilities CVE-2023-6357, CVE-2024-12429 and CVE-2024-12430, successful authentication is required. Therefore, the affected products shall only be used with activated user management
and by setting strong passwords. Details regarding the device user management are available from the
application note “AC500 User Management with V3”.
ABB strongly recommends using the online user management. This not only prevents an attacker from
downloading and execute malicious code, but also suppresses start, stop, debug, or other actions on a known working application that could potentially disrupt a machine or system.
Mitigating factors
Refer to section “General security recommendations” for further advise on how to keep your system secure
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory. \nAn attacker who successfully exploited these vulnerabilities could call shell functions (CVE-2023-6357), \ncrash the PLC (CVE-2024-5000), crash the web server of the PLC (CVE-2024-8175), grant read access to \nfiles (CVE-2024-12429) or enable command execution (CVE-2024-12430).\nThe vulnerabilities CVE-2023-6357, CVE-2024-12429 and CVE-2024-12430 require successful authentication.\n",
"title": "Summary"
},
{
"category": "other",
"text": "For any installation of software-related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:\n\u2013 Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls \nand separate them from any general-purpose network (e.g. office or home networks).\n\u2013 Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.\n\u2013 Never connect programming software or computers containing programming software to any network other than the network for the devices that it is intended for.\n\u2013 Scan all data imported into your environment before use to detect potential malware infections.\n\u2013 Minimize network exposure for all applications and endpoints to ensure that they are not accessible \nfrom the Internet unless they are designed for such exposure and the intended use requires such.\n\u2013 Ensure all nodes are always up to date in terms of installed software, operating system, and firmware \npatches as well as anti-virus and firewall.\n\u2013 When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices",
"title": "General security recommendations"
},
{
"category": "other",
"text": "For additional instructions and support please contact your local ABB service organization. For contact \ninformation, see www.abb.com/contactcenters.\nInformation about ABB\u2019s cyber security program and capabilities can be found at www.abb.com/cybersecurity.",
"title": "Support"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice, and should not be construed as a \ncommitment by ABB.\nABB provides no warranty, express or implied, including warranties of merchantability and fitness for a \nparticular purpose, for the information contained in this document, and assumes no responsibility for \nany errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of \nthis document, or from the use of any hardware or software described in this document, even if ABB or \nits suppliers have been advised of the possibility of such damages.\nThis document and parts hereof must not be reproduced or copied without written permission from \nABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.\nAll rights to registrations and trademarks reside with their respective owners.\n",
"title": "Notice"
},
{
"category": "general",
"text": "Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. \nABB has tested the following workarounds. Although these workarounds will not correct the underlying \nvulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is \nidentified below as \u201cImpact of workaround\u201d.\nTo exploit the vulnerabilities CVE-2023-6357, CVE-2024-12429 and CVE-2024-12430, successful authentication is required. Therefore, the affected products shall only be used with activated user management \nand by setting strong passwords. Details regarding the device user management are available from the \napplication note \u201cAC500 User Management with V3\u201d.\nABB strongly recommends using the online user management. This not only prevents an attacker from \ndownloading and execute malicious code, but also suppresses start, stop, debug, or other actions on a known working application that could potentially disrupt a machine or system.",
"title": "Workarounds"
},
{
"category": "general",
"text": "Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure",
"title": "Mitigating factors"
}
],
"publisher": {
"category": "vendor",
"name": "ABB PSIRT",
"namespace": "https://global.abb/group/en/technology/cyber-security/alerts-and-notifications"
},
"references": [
{
"category": "self",
"summary": "ABB CYBERSECURITY ADVISORY - PDF version",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011377\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"summary": "CVE-2023-6357: CODESYS Control V3 on Linux and QNX operating systems\n",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18027\u0026token=43109051cf95d3445bc616e4efb8414336ebcc47\u0026download="
},
{
"summary": "CVE-2024-5000: CODESYS Control V3 - OPC UA Stack",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
},
{
"summary": "CVE-2024-8175: CODESYS Control V3 web server",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
},
{
"summary": "Application note: AC500 User Management with V3",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR010315\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"summary": "Automation Builder 2.8.0",
"url": "https://new.abb.com/plc/automationbuilder/platform/software"
},
{
"category": "self",
"summary": "ABB CYBERSECURITY ADVISORY - CSAF version",
"url": "https://psirt.abb.com/csaf/2025/3adr011377.json"
}
],
"title": "AC500 V3 Multiple vulnerabilities",
"tracking": {
"current_release_date": "2025-01-07T00:30:00.000Z",
"generator": {
"date": "2025-09-23T17:38:21.065Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.35"
}
},
"id": "3ADR011377",
"initial_release_date": "2025-01-07T00:30:00.000Z",
"revision_history": [
{
"date": "2025-01-07T00:30:00.000Z",
"legacy_version": "A",
"number": "1",
"summary": "Initial version. "
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.8.0",
"product": {
"name": "AC500 V3 products (PM5xxx) \u003c 3.8.0",
"product_id": "AV1"
}
},
{
"category": "product_version",
"name": "3.8.0",
"product": {
"name": "AC500 V3 firmware version 3.8.0",
"product_id": "FX1"
}
}
],
"category": "product_name",
"name": "AC500 V3"
}
],
"category": "vendor",
"name": "ABB"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-6357",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "A successfully authenticated control programmer could exploit this vulnerability to inject calls to additional operating system shell functions via the SysFile or CAA file system libraries.",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"FX1"
],
"known_affected": [
"AV1"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-6357",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-6357"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "The problem is corrected in AC500 V3 firmware version 3.8.0.\n\nABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0. ",
"product_ids": [
"AV1"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"AV1"
]
}
],
"title": " CVE-2023-6357"
},
{
"cve": "CVE-2024-5000",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "description",
"text": "The OPC UA stack, implemented by the CmpOPCUAStack component, is an optional part of the runtime \nsystem. Both the OPC UA Server and the OPC UA Client of the runtime system use the OPC UA Stack as a \ncommon implementation. The OPC UA protocol enables data exchange between the runtime system and \nOPC UA clients such as SCADA or HMIs, or OPC UA servers such as PLCs or other devices.\nIf a runtime system containing the CmpOPCUAStack component receives a specially crafted request/response, the required buffer size in the OPC UA server/client may be incorrectly calculated. This can lead \nto a crash of the runtime system during the subsequent initialization of the receive buffer with zero.\nAn attacker can exploit this vulnerability by using a malicious OPC UA client to send a crafted request to \nthe AC500 V3 PLC with an affected OPC UA server. Conversely, AC500 V3 PLCs with an affected OPC UA \nclient can be crashed if they have connected to a malicious OPC UA server. The runtime systems usually \ncontain both the OPC UA client and the server.\n",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"FX1"
],
"known_affected": [
"AV1"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2024-5000",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-5000"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "The problem is corrected in AC500 V3 firmware version 3.8.0.\n\nABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0. ",
"product_ids": [
"AV1"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"AV1"
]
}
],
"title": "CVE-2024-5000"
},
{
"cve": "CVE-2024-8175",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "description",
"text": "The AC500 V3 web server, implemented by the CmpWebServer component, is an optional part of the \nruntime system. It is used by the AC500 V3 WebVisu to display visualization screens in a web browser. \nThe AC500 V3 web server supports both the HTTP and HTTPS protocols. Because the AC500 V3 web \nserver does not correctly check the return value of an underlying function, it reacts in a wrong way to \nspecifically crafted TLS packets that are received via an HTTPS connection. This causes the AC500 V3 \nweb server to access invalid memory and the web server task to crash.",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"FX1"
],
"known_affected": [
"AV1"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2024-8175",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-8175"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "The problem is corrected in AC500 V3 firmware version 3.8.0.\n\nABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0. ",
"product_ids": [
"AV1"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"AV1"
]
}
],
"title": "CVE-2024-8175"
},
{
"acknowledgments": [
{
"names": [
"D. Blagojevic",
"S. Dietz",
"T. Weber"
],
"organization": " CyberDanube",
"summary": "reporting the vulnerabilities through responsible disclosure"
}
],
"cve": "CVE-2024-12429",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "AC500 V3 PLC has a slot for memory cards that can be used e.g. for logging purposes or for updating \nthe firmware or the boot application. Because the AC500 V3 does not correctly validate the content of \nthe memory card, a specifically crafted memory card can be used for directory traversal. A successfully \nauthenticated attacker can use this vulnerability to read system-wide files and configuration",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"FX1"
],
"known_affected": [
"AV1"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2024-12429",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-12429"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "The problem is corrected in AC500 V3 firmware version 3.8.0.\n\nABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0. ",
"product_ids": [
"AV1"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 4.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 4.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"AV1"
]
}
],
"title": "CVE-2024-12429"
},
{
"acknowledgments": [
{
"names": [
"D. Blagojevic",
"S. Dietz",
"T. Weber"
],
"organization": " CyberDanube",
"summary": "reporting the vulnerabilities through responsible disclosure"
}
],
"cve": "CVE-2024-12430",
"cwe": {
"id": "CWE-280",
"name": "Improper Handling of Insufficient Permissions or Privileges"
},
"notes": [
{
"category": "description",
"text": "After successfully exploiting CVE-2024-12429 (directory traversal), a successfully authenticated attacker \ncan inject arbitrary commands into a specifically crafted file, which then will be executed by root user",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"FX1"
],
"known_affected": [
"AV1"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2024-12430",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-12430"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "The problem is corrected in AC500 V3 firmware version 3.8.0.\n\nABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0. ",
"product_ids": [
"AV1"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"AV1"
]
}
],
"title": "CVE-2024-12430"
}
]
}
CVE-2024-8175
Vulnerability from csaf_codesysgmbh - Published: 2024-09-25 21:59 - Updated: 2025-04-03 10:00Summary
CODESYS: CODESYS web server vulnerable to DoS
Notes
Summary
The CODESYS web server component of the CODESYS Control runtime system is used by the CODESYS
WebVisu to display visualization screens in a web browser. Receiving a specifically crafted TLS packet on an
HTTPS connection causes the CODESYS web server to crash because the return value of an underlying
function is not checked correctly for such unusual conditions.
Impact
The CODESYS web server, implemented by the CmpWebServer component, is an optional part of the
CODESYS Control runtime system. It is used by the CODESYS WebVisu to display CODESYS visualization
screens in a web browser. The CODESYS web server supports both the HTTP and HTTPS protocols.
Because the CODESYS web server does not correctly check the return value of an underlying function, it
reacts in a wrong way to specifically crafted TLS packets that are received via an HTTPS connection. This
causes the CODESYS web server to access invalid memory and the web server task to crash.
Remediation
Update the following products to version 3.5.20.30.
* CODESYS Control RTE (SL)
* CODESYS Control RTE (for Beckhoff CX) SL
* CODESYS Control Win (SL)
* CODESYS HMI (SL)
* CODESYS Runtime Toolkit
* CODESYS Embedded Target Visu Toolkit
* CODESYS Remote Target Visu Toolkit
Update the following products to version 4.14.0.0.
* CODESYS Control for BeagleBone SL
* CODESYS Control for emPC-A/iMX6 SL
* CODESYS Control for Linux ARM SL
* CODESYS Control for Linux SL
* CODESYS Control for PFC100 SL
* CODESYS Control for PFC200 SL
* CODESYS Control for PLCnext SL
* CODESYS Control for Raspberry Pi SL
* CODESYS Control for WAGO Touch Panels 600 SL
* CODESYS Virtual Control SL
Update the following product to version 4.15.0.0 (Version 4.14.0.0 has not been released).
* CODESYS Control for IOT2000 SL
The products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS download area https://www.codesys.com/download .
General Recommendation
As part of a security strategy, CODESYS GmbH strongly recommends at least the following best-practice
defense measures:
* Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside
* Use firewalls to protect and separate the control system network from other networks
* Activate and apply user management and password features
* Limit the access to both development and control system by physical means, operating system features, etc.
* Use encrypted communication links
* Use VPN (Virtual Private Networks) tunnels if remote access is required
* Protect both development and control system by using up to date virus detecting solutions
For more information and general recommendations for protecting machines and plants, see also the
CODESYS Security Whitepaper [here.](https://customers.codesys.com/fileadmin/data/customers/security/CODESYS-Security-Whitepaper.pdf)
Disclaimer
CODESYS GmbH assumes no liability whatsoever for indirect, collateral, accidental or consequential losses
that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided on good faith by CODESYS GmbH.
Insofar as permissible by law, however, none of this information shall establish any guarantee, commitment or
liability on the part of CODESYS GmbH.
Note: Not all CODESYS features are available in all territories. For more information on geographic restrictions,
please contact sales@codesys.com.
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
},
{
"organization": "ABB",
"summary": "reporting"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "The CODESYS web server component of the CODESYS Control runtime system is used by the CODESYS\nWebVisu to display visualization screens in a web browser. Receiving a specifically crafted TLS packet on an\nHTTPS connection causes the CODESYS web server to crash because the return value of an underlying\nfunction is not checked correctly for such unusual conditions.",
"title": "Summary"
},
{
"category": "description",
"text": "The CODESYS web server, implemented by the CmpWebServer component, is an optional part of the\nCODESYS Control runtime system. It is used by the CODESYS WebVisu to display CODESYS visualization\nscreens in a web browser. The CODESYS web server supports both the HTTP and HTTPS protocols.\nBecause the CODESYS web server does not correctly check the return value of an underlying function, it\nreacts in a wrong way to specifically crafted TLS packets that are received via an HTTPS connection. This\ncauses the CODESYS web server to access invalid memory and the web server task to crash.",
"title": "Impact"
},
{
"category": "description",
"text": "Update the following products to version 3.5.20.30.\n* CODESYS Control RTE (SL)\n* CODESYS Control RTE (for Beckhoff CX) SL\n* CODESYS Control Win (SL)\n* CODESYS HMI (SL)\n* CODESYS Runtime Toolkit\n* CODESYS Embedded Target Visu Toolkit\n* CODESYS Remote Target Visu Toolkit\n\nUpdate the following products to version 4.14.0.0.\n* CODESYS Control for BeagleBone SL\n* CODESYS Control for emPC-A/iMX6 SL\n* CODESYS Control for Linux ARM SL\n* CODESYS Control for Linux SL\n* CODESYS Control for PFC100 SL\n* CODESYS Control for PFC200 SL\n* CODESYS Control for PLCnext SL\n* CODESYS Control for Raspberry Pi SL\n* CODESYS Control for WAGO Touch Panels 600 SL\n* CODESYS Virtual Control SL\n\nUpdate the following product to version 4.15.0.0 (Version 4.14.0.0 has not been released). \n* CODESYS Control for IOT2000 SL\n\nThe products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS download area https://www.codesys.com/download .",
"title": "Remediation"
},
{
"category": "general",
"text": "As part of a security strategy, CODESYS GmbH strongly recommends at least the following best-practice\ndefense measures:\n\n* Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside\n* Use firewalls to protect and separate the control system network from other networks\n* Activate and apply user management and password features\n* Limit the access to both development and control system by physical means, operating system features, etc.\n* Use encrypted communication links\n* Use VPN (Virtual Private Networks) tunnels if remote access is required\n* Protect both development and control system by using up to date virus detecting solutions\n\nFor more information and general recommendations for protecting machines and plants, see also the\nCODESYS Security Whitepaper [here.](https://customers.codesys.com/fileadmin/data/customers/security/CODESYS-Security-Whitepaper.pdf)\n",
"title": "General Recommendation"
},
{
"category": "legal_disclaimer",
"text": "CODESYS GmbH assumes no liability whatsoever for indirect, collateral, accidental or consequential losses\nthat occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided on good faith by CODESYS GmbH.\nInsofar as permissible by law, however, none of this information shall establish any guarantee, commitment or\nliability on the part of CODESYS GmbH.\n\nNote: Not all CODESYS features are available in all territories. For more information on geographic restrictions,\nplease contact sales@codesys.com.",
"title": "Disclaimer"
}
],
"publisher": {
"category": "vendor",
"contact_details": "security@codesys.com",
"name": "CODESYS GmbH",
"namespace": "https://www.codesys.com"
},
"references": [
{
"category": "external",
"summary": "CERT@VDE Security Advisories for CODESYS GmbH",
"url": "https://certvde.com/en/advisories/vendor/codesys"
},
{
"category": "self",
"summary": "Advisory2024-05_VDE-2024-057: CODESYS: CODESYS web server vulnerable to DoS - HTML",
"url": "https://certvde.com/en/advisories/VDE-2024-057"
},
{
"category": "self",
"summary": "CODESYS Security Advisory 2024-05",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
},
{
"category": "external",
"summary": "CODESYS Security Advisories",
"url": "https://www.codesys.com/security/security-reports.html"
},
{
"category": "self",
"summary": "Advisory2024-05_VDE-2024-057: CODESYS: CODESYS web server vulnerable to DoS - CSAF",
"url": "https://codesys.csaf-tp.certvde.com/.well-known/csaf/white/2024/advisory2024-05_vde-2024-057.json"
}
],
"title": "CODESYS: CODESYS web server vulnerable to DoS",
"tracking": {
"aliases": [
"VDE-2024-057",
"CODESYS Security Advisory 2024-05"
],
"current_release_date": "2025-04-03T10:00:00.000Z",
"generator": {
"date": "2025-03-27T10:26:55.430Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.21"
}
},
"id": "Advisory2024-05_VDE-2024-057",
"initial_release_date": "2024-09-25T21:59:00.000Z",
"revision_history": [
{
"date": "2024-09-25T21:59:00.000Z",
"number": "1",
"summary": "Initial revision."
},
{
"date": "2024-12-12T11:00:00.000Z",
"number": "2",
"summary": "Further software update available"
},
{
"date": "2025-04-03T10:00:00.000Z",
"number": "3",
"summary": "Fixed version information for CODESYS Control for IOT2000 SL.\nFixed typos in version ranges."
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS Control RTE (for Beckhoff CX) SL \u003c3.5.20.30",
"product_id": "CSAFPID-41001"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS Control RTE (for Beckhoff CX) SL 3.5.20.30",
"product_id": "CSAFPID-42001"
}
}
],
"category": "product_name",
"name": "Control RTE (for Beckhoff CX) SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS Control RTE (SL) \u003c3.5.20.30",
"product_id": "CSAFPID-41002"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS Control RTE (SL) 3.5.20.30",
"product_id": "CSAFPID-42002"
}
}
],
"category": "product_name",
"name": "Control RTE (SL) "
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS Control Win (SL) \u003c3.5.20.30",
"product_id": "CSAFPID-41003"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS Control Win (SL) 3.5.20.30",
"product_id": "CSAFPID-42003"
}
}
],
"category": "product_name",
"name": "Control Win (SL)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS Embedded Target Visu Toolkit \u003c3.5.20.30",
"product_id": "CSAFPID-41004"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS Embedded Target Visu Toolkit 3.5.20.30",
"product_id": "CSAFPID-42004"
}
}
],
"category": "product_name",
"name": "Embedded Target Visu Toolkit"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS HMI (SL) \u003c3.5.20.30",
"product_id": "CSAFPID-41005"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS HMI (SL) 3.5.20.30",
"product_id": "CSAFPID-42005"
}
}
],
"category": "product_name",
"name": "HMI (SL)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS Remote Target Visu Toolkit \u003c3.5.20.30",
"product_id": "CSAFPID-41006"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS Remote Target Visu Toolkit 3.5.20.30",
"product_id": "CSAFPID-42006"
}
}
],
"category": "product_name",
"name": "Remote Target Visu Toolkit"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.5.20.30",
"product": {
"name": "CODESYS Runtime Toolkit \u003c3.5.20.30",
"product_id": "CSAFPID-41007"
}
},
{
"category": "product_version",
"name": "3.5.20.30",
"product": {
"name": "CODESYS Runtime Toolkit 3.5.20.30",
"product_id": "CSAFPID-42007"
}
}
],
"category": "product_name",
"name": "Runtime Toolkit "
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Virtual Control SL \u003c4.14.0.0",
"product_id": "CSAFPID-41008"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Virtual Control SL 4.14.0.0",
"product_id": "CSAFPID-42008"
}
}
],
"category": "product_name",
"name": "Virtual Control SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for BeagleBone SL \u003c4.14.0.0",
"product_id": "CSAFPID-41009"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for BeagleBone SL 4.14.0.0",
"product_id": "CSAFPID-42009"
}
}
],
"category": "product_name",
"name": "Control for BeagleBone SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for emPC-A/iMX6 SL \u003c4.14.0.0",
"product_id": "CSAFPID-41010"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for emPC-A/iMX6 SL 4.14.0.0",
"product_id": "CSAFPID-42010"
}
}
],
"category": "product_name",
"name": "Control for emPC-A/iMX6 SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for IOT2000 SL \u003c4.14.0.0",
"product_id": "CSAFPID-41011"
}
},
{
"category": "product_version",
"name": "4.15.0.0",
"product": {
"name": "CODESYS Control for IOT2000 SL 4.15.0.0",
"product_id": "CSAFPID-42011"
}
}
],
"category": "product_name",
"name": "Control for IOT2000 SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for Linux ARM SL \u003c4.14.0.0",
"product_id": "CSAFPID-41012"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for Linux ARM SL 4.14.0.0",
"product_id": "CSAFPID-42012"
}
}
],
"category": "product_name",
"name": "Control for Linux ARM SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for Linux SL \u003c4.14.0.0",
"product_id": "CSAFPID-41013"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for Linux SL 4.14.0.0",
"product_id": "CSAFPID-42013"
}
}
],
"category": "product_name",
"name": "Control for Linux SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for PFC100 SL \u003c4.14.0.0",
"product_id": "CSAFPID-41014"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for PFC100 SL 4.14.0.0",
"product_id": "CSAFPID-42014"
}
}
],
"category": "product_name",
"name": "Control for PFC100 SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for PFC200 SL \u003c4.14.0.0",
"product_id": "CSAFPID-41015"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for PFC200 SL 4.14.0.0",
"product_id": "CSAFPID-42015"
}
}
],
"category": "product_name",
"name": " Control for PFC200 SL "
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for PLCnext SL \u003c4.14.0.0",
"product_id": "CSAFPID-41016"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for PLCnext SL 4.14.0.0",
"product_id": "CSAFPID-42016"
}
}
],
"category": "product_name",
"name": "Control for PLCnext SL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for Raspberry Pi SL \u003c4.14.0.0",
"product_id": "CSAFPID-41017"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for Raspberry Pi SL 4.14.0.0",
"product_id": "CSAFPID-42017"
}
}
],
"category": "product_name",
"name": "Control for Raspberry Pi SL "
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.14.0.0",
"product": {
"name": "CODESYS Control for WAGO Touch Panels 600 SL \u003c4.14.0.0",
"product_id": "CSAFPID-41018"
}
},
{
"category": "product_version",
"name": "4.14.0.0",
"product": {
"name": "CODESYS Control for WAGO Touch Panels 600 SL 4.14.0.0",
"product_id": "CSAFPID-42018"
}
}
],
"category": "product_name",
"name": "Control for WAGO Touch Panels 600 SL"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "CODESYS"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-41001",
"CSAFPID-41002",
"CSAFPID-41003",
"CSAFPID-41004",
"CSAFPID-41005",
"CSAFPID-41006",
"CSAFPID-41007"
],
"summary": "Affected products v3.5.x."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-42001",
"CSAFPID-42002",
"CSAFPID-42003",
"CSAFPID-42004",
"CSAFPID-42005",
"CSAFPID-42006",
"CSAFPID-42007"
],
"summary": "Fixed products v3.5.x."
},
{
"group_id": "CSAFGID-0003",
"product_ids": [
"CSAFPID-41008",
"CSAFPID-41009",
"CSAFPID-41010",
"CSAFPID-41011",
"CSAFPID-41012",
"CSAFPID-41013",
"CSAFPID-41014",
"CSAFPID-41015",
"CSAFPID-41016",
"CSAFPID-41017",
"CSAFPID-41018"
],
"summary": "Affected products v4.x."
},
{
"group_id": "CSAFGID-0004",
"product_ids": [
"CSAFPID-42008",
"CSAFPID-42009",
"CSAFPID-42010",
"CSAFPID-42012",
"CSAFPID-42013",
"CSAFPID-42014",
"CSAFPID-42015",
"CSAFPID-42016",
"CSAFPID-42017",
"CSAFPID-42018"
],
"summary": "Fixed products v4.x."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-8175",
"cwe": {
"id": "CWE-253",
"name": "Incorrect Check of Function Return Value"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker sending a specially crafted TLS packet on an HTTPS connection causes the CODESYS web server to access invalid memory, resulting in a DoS.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-42001",
"CSAFPID-42002",
"CSAFPID-42003",
"CSAFPID-42004",
"CSAFPID-42005",
"CSAFPID-42006",
"CSAFPID-42007",
"CSAFPID-42008",
"CSAFPID-42009",
"CSAFPID-42010",
"CSAFPID-42011",
"CSAFPID-42012",
"CSAFPID-42013",
"CSAFPID-42014",
"CSAFPID-42015",
"CSAFPID-42016",
"CSAFPID-42017",
"CSAFPID-42018"
],
"known_affected": [
"CSAFPID-41001",
"CSAFPID-41002",
"CSAFPID-41003",
"CSAFPID-41004",
"CSAFPID-41005",
"CSAFPID-41006",
"CSAFPID-41007",
"CSAFPID-41008",
"CSAFPID-41009",
"CSAFPID-41010",
"CSAFPID-41011",
"CSAFPID-41012",
"CSAFPID-41013",
"CSAFPID-41014",
"CSAFPID-41015",
"CSAFPID-41016",
"CSAFPID-41017",
"CSAFPID-41018"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update the following products to version 3.5.20.30.\n* CODESYS Control RTE (SL)\n* CODESYS Control RTE (for Beckhoff CX) SL\n* CODESYS Control Win (SL)\n* CODESYS HMI (SL)\n* CODESYS Runtime Toolkit\n* CODESYS Embedded Target Visu Toolkit\n* CODESYS Remote Target Visu Toolkit\n\nThe products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS\nInstaller or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will\nfind further information on obtaining the software update in the CODESYS download area.",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update the following products to version 4.14.0.0.\n* CODESYS Control for BeagleBone SL\n* CODESYS Control for emPC-A/iMX6 SL\n* CODESYS Control for Linux ARM SL\n* CODESYS Control for Linux SL\n* CODESYS Control for PFC100 SL\n* CODESYS Control for PFC200 SL\n* CODESYS Control for PLCnext SL\n* CODESYS Control for Raspberry Pi SL\n* CODESYS Control for WAGO Touch Panels 600 SL\n* CODESYS Virtual Control SL\n\nThe products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS\nInstaller or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will\nfind further information on obtaining the software update in the CODESYS download area.",
"group_ids": [
"CSAFGID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update the following product to version 4.15.0.0 (Version 4.14.0.0 has not been released). \n* CODESYS Control for IOT2000 SL\n\nThe products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS\nInstaller or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will\nfind further information on obtaining the software update in the CODESYS download area.",
"product_ids": [
"CSAFPID-41011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-41001",
"CSAFPID-41002",
"CSAFPID-41003",
"CSAFPID-41004",
"CSAFPID-41005",
"CSAFPID-41006",
"CSAFPID-41007",
"CSAFPID-41008",
"CSAFPID-41009",
"CSAFPID-41010",
"CSAFPID-41011",
"CSAFPID-41012",
"CSAFPID-41013",
"CSAFPID-41014",
"CSAFPID-41015",
"CSAFPID-41016",
"CSAFPID-41017",
"CSAFPID-41018"
]
}
],
"title": "CVE-2024-8175"
}
]
}
CVE-2024-8175
Vulnerability from csaf_wagogmbhcokg - Published: 2024-12-03 11:00 - Updated: 2024-12-03 11:00Summary
WAGO: Vulnerabilities in CODESYS Control
Notes
Summary
The following firmware versions installed on several devices are vulnerable due to a vulnerability in the CODESYS Control V3 web server.
Impact
The configuration UI called web based management is part of the control runtime system and is also used for the visualization of running applications. Because the web server does not correctly check the return value of an underlying function, it reacts in a wrong way to specifically crafted TLS packets that are received via an HTTPS connection. This causes the web server to access invalid memory and the web server task to crash.
Remediation
Update to Firmware version 01.04.07 (FW4).
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
"text": "High"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "The following firmware versions installed on several devices are vulnerable due to a vulnerability in the CODESYS Control V3 web server.",
"title": "Summary"
},
{
"category": "description",
"text": "The configuration UI called web based management is part of the control runtime system and is also used for the visualization of running applications. Because the web server does not correctly check the return value of an underlying function, it reacts in a wrong way to specifically crafted TLS packets that are received via an HTTPS connection. This causes the web server to access invalid memory and the web server task to crash.",
"title": "Impact"
},
{
"category": "description",
"text": "Update to Firmware version 01.04.07 (FW4).",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@wago.com",
"name": "WAGO GmbH \u0026 Co. KG",
"namespace": "https://www.wago.com/psirt"
},
"references": [
{
"category": "external",
"summary": "CERT@VDE Security Advisories for WAGO",
"url": "https://certvde.com/de/advisories/vendor/wago/"
},
{
"category": "self",
"summary": "VDE-2024-072: WAGO: Vulnerabilities in CODESYS Control - HTML",
"url": "https://certvde.com/en/advisories/VDE-2024-072"
},
{
"category": "self",
"summary": "VDE-2024-072: WAGO: Vulnerabilities in CODESYS Control - CSAF",
"url": "https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2024/vde-2024-072.json"
}
],
"source_lang": "en",
"title": "WAGO: Vulnerabilities in CODESYS Control",
"tracking": {
"aliases": [
"VDE-2024-072"
],
"current_release_date": "2024-12-03T11:00:00.000Z",
"generator": {
"date": "2024-12-02T08:10:08.806Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.15"
}
},
"id": "VDE-2024-072",
"initial_release_date": "2024-12-03T11:00:00.000Z",
"revision_history": [
{
"date": "2024-12-03T11:00:00.000Z",
"number": "1",
"summary": "Initial revision."
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_name",
"name": "0751-8000",
"product": {
"name": "Basic Controller 0751-8000",
"product_id": "CSAFPID-11001",
"product_identification_helper": {
"model_numbers": [
"0751-9?01"
]
}
}
},
{
"category": "product_name",
"name": "0750-8001",
"product": {
"name": "Basic Controller 0750-8001",
"product_id": "CSAFPID-11002"
}
}
],
"category": "product_family",
"name": "Basic Controller"
}
],
"category": "product_family",
"name": "Hardware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=01.03.03 (FW3)",
"product": {
"name": "Firmware \u003c=01.03.03 (FW3)",
"product_id": "CSAFPID-21001"
}
},
{
"category": "product_version",
"name": "01.04.07 (FW4)",
"product": {
"name": "Firmware 01.04.07 (FW4)",
"product_id": "CSAFPID-22001"
}
}
],
"category": "product_family",
"name": "Firmware"
}
],
"category": "vendor",
"name": "WAGO"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002"
],
"summary": "Affected products."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-32001",
"CSAFPID-32002"
],
"summary": "Fixed products."
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware \u003c=01.03.03 (FW3) installed on Basic Controller 0751-8000",
"product_id": "CSAFPID-31001"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware \u003c=01.03.03 (FW3) installed on Basic Controller 0750-8001",
"product_id": "CSAFPID-31002"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11002"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware 01.04.07 (FW4) installed on Basic Controller 0751-8000",
"product_id": "CSAFPID-32001"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware 01.04.07 (FW4) installed on Basic Controller 0750-8001",
"product_id": "CSAFPID-32002"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11002"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-8175",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Receiving a specifically crafted TLS packet on an HTTPS connection causes the CODESYS web server to crash because the return value of an underlying function is not checked correctly for such unusual conditions.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001",
"CSAFPID-32002"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002"
]
},
"references": [
{
"category": "external",
"summary": "CODESYS Advisory 2024-05",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"remediations": [
{
"category": "vendor_fix",
"date": "2024-10-04T09:00:00.000Z",
"details": "Update to Firmware version 01.04.07 (FW4).",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"title": "CVE-2024-8175"
}
]
}
CVE-2024-8175
Vulnerability from fstec - Published: 24.09.2024
VLAI Severity ?
Title
Уязвимость веб-сервера CODESYS среды выполнения CODESYS Control, позволяющая нарушителю вызвать отказ в обслуживании
Description
Уязвимость веб-сервера CODESYS среды выполнения CODESYS Control связана с недостаточной проверкой необычных или исключительных состояний. Эксплуатация уязвимости может позволить нарушителю, действующему удалённо, вызвать отказ в обслуживании путём отправки специально сформированного TLS-пакета
Severity ?
Vendor
CODESYS GmbH
Software Name
CODESYS Control RTE (SL), CODESYS Control RTE (for Beckhoff CX) SL, CODESYS Control Win (SL), CODESYS HMI (SL), CODESYS Runtime Toolkit, CODESYS Embedded Target Visu Toolkit, CODESYS Remote Target Visu Toolkit, CODESYS Control for BeagleBone SL, CODESYS Control for emPC-A/iMX6 SL, CODESYS Control for IOT2000 SL, CODESYS Control for Linux SL, CODESYS Control for Linux ARM SL, CODESYS Control for PFC100 SL, CODESYS Control for PFC200 SL, CODESYS Control for PLCnext SL, CODESYS Control for Raspberry Pi SL, CODESYS Control for WAGO Touch Panels 600 SL, CODESYS Virtual Control SL
Software Version
до 3.5.20.30 (CODESYS Control RTE (SL)), до 3.5.20.30 (CODESYS Control RTE (for Beckhoff CX) SL), до 3.5.20.30 (CODESYS Control Win (SL)), до 3.5.20.30 (CODESYS HMI (SL)), до 3.5.20.30 (CODESYS Runtime Toolkit), до 3.5.20.30 (CODESYS Embedded Target Visu Toolkit), до 3.5.20.30 (CODESYS Remote Target Visu Toolkit), до 4.14.0.0 (CODESYS Control for BeagleBone SL), до 4.14.0.0 (CODESYS Control for emPC-A/iMX6 SL), до 4.14.0.0 (CODESYS Control for IOT2000 SL), до 4.14.0.0 (CODESYS Control for Linux SL), до 4.14.0.0 (CODESYS Control for Linux ARM SL), до 4.14.0.0 (CODESYS Control for PFC100 SL), до 4.14.0.0 (CODESYS Control for PFC200 SL), до 4.14.0.0 (CODESYS Control for PLCnext SL), до 4.14.0.0 (CODESYS Control for Raspberry Pi SL), до 4.14.0.0 (CODESYS Control for WAGO Touch Panels 600 SL), до 4.14.0.0 (CODESYS Virtual Control SL)
Possible Mitigations
Установка обновлений из доверенных источников.
В связи со сложившейся обстановкой и введенными санкциями против Российской Федерации рекомендуется устанавливать обновления программного обеспечения только после оценки всех сопутствующих рисков.
Компенсирующие меры:
- сегментирование сети для ограничения доступа к промышленному оборудованию;
- ограничение доступа из внешних сетей (Интернет) к промышленному оборудованию;
- использование средств межсетевого экранирования для фильтрации TLS-пакетов;
- использование виртуальных частных сетей для организации удаленного доступа (VPN).
Использование рекомендаций:
https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=18604&token=d5e1e2820ee63077b875b3bb41014b1f102e88a3&download=
Reference
https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=18604&token=d5e1e2820ee63077b875b3bb41014b1f102e88a3&download=
CWE
CWE-754
{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "CODESYS GmbH",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 3.5.20.30 (CODESYS Control RTE (SL)), \u0434\u043e 3.5.20.30 (CODESYS Control RTE (for Beckhoff CX) SL), \u0434\u043e 3.5.20.30 (CODESYS Control Win (SL)), \u0434\u043e 3.5.20.30 (CODESYS HMI (SL)), \u0434\u043e 3.5.20.30 (CODESYS Runtime Toolkit), \u0434\u043e 3.5.20.30 (CODESYS Embedded Target Visu Toolkit), \u0434\u043e 3.5.20.30 (CODESYS Remote Target Visu Toolkit), \u0434\u043e 4.14.0.0 (CODESYS Control for BeagleBone SL), \u0434\u043e 4.14.0.0 (CODESYS Control for emPC-A/iMX6 SL), \u0434\u043e 4.14.0.0 (CODESYS Control for IOT2000 SL), \u0434\u043e 4.14.0.0 (CODESYS Control for Linux SL), \u0434\u043e 4.14.0.0 (CODESYS Control for Linux ARM SL), \u0434\u043e 4.14.0.0 (CODESYS Control for PFC100 SL), \u0434\u043e 4.14.0.0 (CODESYS Control for PFC200 SL), \u0434\u043e 4.14.0.0 (CODESYS Control for PLCnext SL), \u0434\u043e 4.14.0.0 (CODESYS Control for Raspberry Pi SL), \u0434\u043e 4.14.0.0 (CODESYS Control for WAGO Touch Panels 600 SL), \u0434\u043e 4.14.0.0 (CODESYS Virtual Control SL)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0439 \u0438\u0437 \u0434\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432.\n\u0412 \u0441\u0432\u044f\u0437\u0438 \u0441\u043e \u0441\u043b\u043e\u0436\u0438\u0432\u0448\u0435\u0439\u0441\u044f \u043e\u0431\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u043e\u0439 \u0438 \u0432\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u0430\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u043f\u0440\u043e\u0442\u0438\u0432 \u0420\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u043e\u0439 \u0424\u0435\u0434\u0435\u0440\u0430\u0446\u0438\u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u0442\u0441\u044f \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u043e\u0441\u043b\u0435 \u043e\u0446\u0435\u043d\u043a\u0438 \u0432\u0441\u0435\u0445 \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0440\u0438\u0441\u043a\u043e\u0432.\n\n\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u0438\u0437 \u0432\u043d\u0435\u0448\u043d\u0438\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442) \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0444\u0438\u043b\u044c\u0442\u0440\u0430\u0446\u0438\u0438 TLS-\u043f\u0430\u043a\u0435\u0442\u043e\u0432;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN).\n\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download=",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "24.09.2024",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "30.12.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "30.09.2024",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2024-07535",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2024-8175",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "CODESYS Control RTE (SL), CODESYS Control RTE (for Beckhoff CX) SL, CODESYS Control Win (SL), CODESYS HMI (SL), CODESYS Runtime Toolkit, CODESYS Embedded Target Visu Toolkit, CODESYS Remote Target Visu Toolkit, CODESYS Control for BeagleBone SL, CODESYS Control for emPC-A/iMX6 SL, CODESYS Control for IOT2000 SL, CODESYS Control for Linux SL, CODESYS Control for Linux ARM SL, CODESYS Control for PFC100 SL, CODESYS Control for PFC200 SL, CODESYS Control for PLCnext SL, CODESYS Control for Raspberry Pi SL, CODESYS Control for WAGO Touch Panels 600 SL, CODESYS Virtual Control SL",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u0435\u0431-\u0441\u0435\u0440\u0432\u0435\u0440\u0430 CODESYS \u0441\u0440\u0435\u0434\u044b \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f CODESYS Control, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043d\u0435\u043e\u0431\u044b\u0447\u043d\u044b\u0445 \u0438\u043b\u0438 \u0438\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0439 (CWE-754)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u0435\u0431-\u0441\u0435\u0440\u0432\u0435\u0440\u0430 CODESYS \u0441\u0440\u0435\u0434\u044b \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f CODESYS Control \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u043e\u0439 \u043d\u0435\u043e\u0431\u044b\u0447\u043d\u044b\u0445 \u0438\u043b\u0438 \u0438\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0439. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043f\u0443\u0442\u0451\u043c \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u0444\u043e\u0440\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e TLS-\u043f\u0430\u043a\u0435\u0442\u0430",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u0418\u0441\u0447\u0435\u0440\u043f\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download=",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f, \u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-754",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.1 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)"
}
FKIE_CVE-2024-8175
Vulnerability from fkie_nvd - Published: 2024-09-25 08:15 - Updated: 2024-09-26 13:32
Severity ?
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado puede provocar que el servidor web CODESYS acceda a una memoria no v\u00e1lida, lo que resulta en un DoS."
}
],
"id": "CVE-2024-8175",
"lastModified": "2024-09-26T13:32:02.803",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
},
"published": "2024-09-25T08:15:04.727",
"references": [
{
"source": "info@cert.vde.com",
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"source": "info@cert.vde.com",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…