CWE-940
Improper Verification of Source of a Communication Channel
The product establishes a communication channel to handle an incoming request that has been initiated by an actor, but it does not properly verify that the request is coming from the expected origin.
CVE-2025-0036 (GCVE-0-2025-0036)
Vulnerability from cvelistv5
- CWE-682 - Incorrect Calculation
- CWE-772 - Missing Release of Resource after Effective Lifetime
- CWE-940 - Improper Verification of Source of a Communication Channel
- CWE-941 - Incorrectly Specified Destination in a Communication Channel
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
| Vendor | Product | Version | ||
|---|---|---|---|---|
| AMD | Versal Adaptive SoC Devices |
Patch: 2025.1 release |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0036",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:19:45.871057Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:27:43.315Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Versal Adaptive SoC Devices",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal RF Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal AI Edge Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal Prime Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal Premium Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal AI Core Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal HBM Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Alveo V80 Compute Accelerator",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
}
],
"datePublic": "2025-06-03T16:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.\u003cbr\u003e"
}
],
"value": "In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.2,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-682",
"description": "CWE-682 Incorrect Calculation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-772",
"description": "CWE-772 Missing Release of Resource after Effective Lifetime",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-941",
"description": "CWE-941 Incorrectly Specified Destination in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T14:48:59.255Z",
"orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
"shortName": "AMD"
},
"references": [
{
"url": "https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8011.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
"assignerShortName": "AMD",
"cveId": "CVE-2025-0036",
"datePublished": "2025-06-09T23:57:39.748Z",
"dateReserved": "2024-11-21T16:18:02.918Z",
"dateUpdated": "2025-06-30T14:48:59.255Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-13086 (GCVE-0-2025-13086)
Vulnerability from cvelistv5
- CWE-940 - Improper Verification of Source of a Communication Channel
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-03T21:48:54.419203Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-03T21:49:07.801Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OpenVPN",
"vendor": "OpenVPN",
"versions": [
{
"lessThanOrEqual": "2.6.15",
"status": "affected",
"version": "2.6.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "2.7_rc1",
"status": "affected",
"version": "2.7_alpha1",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper validation of source IP addresses in OpenVPN version 2.6.0 through 2.6.15 and 2.7_alpha1 through 2.7_rc1 allows an attacker to open a session from a different IP address which did not initiate the connection resulting in a denial of service for the originating client"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940: Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-12T13:50:46.678Z",
"orgId": "36a55730-e66d-4d39-8ca6-3c3b3017965e",
"shortName": "OpenVPN"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://community.openvpn.net/Security%20Announcements/CVE-2025-13086"
},
{
"tags": [
"release-notes"
],
"url": "https://www.mail-archive.com/openvpn-announce@lists.sourceforge.net/msg00152.html"
},
{
"tags": [
"release-notes"
],
"url": "https://www.mail-archive.com/openvpn-announce@lists.sourceforge.net/msg00151.html"
}
],
"x_generator": {
"engine": "cvelib 1.8.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "36a55730-e66d-4d39-8ca6-3c3b3017965e",
"assignerShortName": "OpenVPN",
"cveId": "CVE-2025-13086",
"datePublished": "2025-12-03T19:54:10.737Z",
"dateReserved": "2025-11-12T19:37:55.606Z",
"dateUpdated": "2025-12-12T13:50:46.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-20365 (GCVE-0-2025-20365)
Vulnerability from cvelistv5
- CWE-940 - Improper Verification of Source of a Communication Channel
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cisco | Cisco Aironet Access Point Software (IOS XE Controller) |
Version: 16.10.1e Version: 16.10.1 Version: 17.1.1t Version: 17.1.1s Version: 17.1.1 Version: 16.11.1a Version: 16.11.1 Version: 16.11.1c Version: 16.11.1b Version: 16.12.1s Version: 16.12.4 Version: 16.12.1 Version: 16.12.2s Version: 16.12.1t Version: 16.12.4a Version: 16.12.5 Version: 16.12.3 Version: 16.12.6 Version: 16.12.8 Version: 16.12.7 Version: 16.12.6a Version: 17.3.1 Version: 17.3.2a Version: 17.3.3 Version: 17.3.4 Version: 17.3.5 Version: 17.3.2 Version: 17.3.4c Version: 17.3.5a Version: 17.3.5b Version: 17.3.6 Version: 17.3.7 Version: 17.3.8 Version: 17.3.8a Version: 17.2.1 Version: 17.2.1a Version: 17.2.3 Version: 17.2.2 Version: 17.5.1 Version: 17.4.1 Version: 17.6.1 Version: 17.6.2 Version: 17.6.3 Version: 17.6.4 Version: 17.6.5 Version: 17.6.6 Version: 17.6.6a Version: 17.6.5a Version: 17.6.7 Version: 17.6.8 Version: 17.10.1 Version: 17.9.1 Version: 17.9.2 Version: 17.9.3 Version: 17.9.4 Version: 17.9.4a Version: 17.9.5 Version: 17.9.6 Version: 17.9.7 Version: 17.7.1 Version: 17.8.1 Version: 17.11.1 Version: 17.12.1 Version: 17.12.2 Version: 17.12.3 Version: 17.12.5 Version: 17.13.1 Version: 17.14.1 Version: 17.15.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-20365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-15T16:04:21.044698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-15T16:04:29.084Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Aironet Access Point Software (IOS XE Controller)",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "16.10.1e"
},
{
"status": "affected",
"version": "16.10.1"
},
{
"status": "affected",
"version": "17.1.1t"
},
{
"status": "affected",
"version": "17.1.1s"
},
{
"status": "affected",
"version": "17.1.1"
},
{
"status": "affected",
"version": "16.11.1a"
},
{
"status": "affected",
"version": "16.11.1"
},
{
"status": "affected",
"version": "16.11.1c"
},
{
"status": "affected",
"version": "16.11.1b"
},
{
"status": "affected",
"version": "16.12.1s"
},
{
"status": "affected",
"version": "16.12.4"
},
{
"status": "affected",
"version": "16.12.1"
},
{
"status": "affected",
"version": "16.12.2s"
},
{
"status": "affected",
"version": "16.12.1t"
},
{
"status": "affected",
"version": "16.12.4a"
},
{
"status": "affected",
"version": "16.12.5"
},
{
"status": "affected",
"version": "16.12.3"
},
{
"status": "affected",
"version": "16.12.6"
},
{
"status": "affected",
"version": "16.12.8"
},
{
"status": "affected",
"version": "16.12.7"
},
{
"status": "affected",
"version": "16.12.6a"
},
{
"status": "affected",
"version": "17.3.1"
},
{
"status": "affected",
"version": "17.3.2a"
},
{
"status": "affected",
"version": "17.3.3"
},
{
"status": "affected",
"version": "17.3.4"
},
{
"status": "affected",
"version": "17.3.5"
},
{
"status": "affected",
"version": "17.3.2"
},
{
"status": "affected",
"version": "17.3.4c"
},
{
"status": "affected",
"version": "17.3.5a"
},
{
"status": "affected",
"version": "17.3.5b"
},
{
"status": "affected",
"version": "17.3.6"
},
{
"status": "affected",
"version": "17.3.7"
},
{
"status": "affected",
"version": "17.3.8"
},
{
"status": "affected",
"version": "17.3.8a"
},
{
"status": "affected",
"version": "17.2.1"
},
{
"status": "affected",
"version": "17.2.1a"
},
{
"status": "affected",
"version": "17.2.3"
},
{
"status": "affected",
"version": "17.2.2"
},
{
"status": "affected",
"version": "17.5.1"
},
{
"status": "affected",
"version": "17.4.1"
},
{
"status": "affected",
"version": "17.6.1"
},
{
"status": "affected",
"version": "17.6.2"
},
{
"status": "affected",
"version": "17.6.3"
},
{
"status": "affected",
"version": "17.6.4"
},
{
"status": "affected",
"version": "17.6.5"
},
{
"status": "affected",
"version": "17.6.6"
},
{
"status": "affected",
"version": "17.6.6a"
},
{
"status": "affected",
"version": "17.6.5a"
},
{
"status": "affected",
"version": "17.6.7"
},
{
"status": "affected",
"version": "17.6.8"
},
{
"status": "affected",
"version": "17.10.1"
},
{
"status": "affected",
"version": "17.9.1"
},
{
"status": "affected",
"version": "17.9.2"
},
{
"status": "affected",
"version": "17.9.3"
},
{
"status": "affected",
"version": "17.9.4"
},
{
"status": "affected",
"version": "17.9.4a"
},
{
"status": "affected",
"version": "17.9.5"
},
{
"status": "affected",
"version": "17.9.6"
},
{
"status": "affected",
"version": "17.9.7"
},
{
"status": "affected",
"version": "17.7.1"
},
{
"status": "affected",
"version": "17.8.1"
},
{
"status": "affected",
"version": "17.11.1"
},
{
"status": "affected",
"version": "17.12.1"
},
{
"status": "affected",
"version": "17.12.2"
},
{
"status": "affected",
"version": "17.12.3"
},
{
"status": "affected",
"version": "17.12.5"
},
{
"status": "affected",
"version": "17.13.1"
},
{
"status": "affected",
"version": "17.14.1"
},
{
"status": "affected",
"version": "17.15.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the IPv6 Router Advertisement (RA) packet processing of Cisco Access Point Software could allow an unauthenticated, adjacent attacker to modify the IPv6 gateway on an affected device.\r\n\r This vulnerability is due to a logic error in the processing of IPv6 RA packets that are received from wireless clients. An attacker could exploit this vulnerability by associating to a wireless network and sending a series of crafted IPv6 RA packets. A successful exploit could allow the attacker to temporarily change the IPv6 gateway of an affected device. This could also lead to intermittent packet loss for any wireless clients that are associated with the affected device."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "cvssV3_1"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "cwe"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-26T17:11:13.040Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "cisco-sa-ap-ipv6-gw-tUAzpn9O",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ap-ipv6-gw-tUAzpn9O"
}
],
"source": {
"advisory": "cisco-sa-ap-ipv6-gw-tUAzpn9O",
"defects": [
"CSCwm13005"
],
"discovery": "INTERNAL"
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2025-20365",
"datePublished": "2025-09-24T16:40:16.763Z",
"dateReserved": "2024-10-10T19:15:13.261Z",
"dateUpdated": "2025-10-15T16:04:29.084Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23018 (GCVE-0-2025-23018)
Vulnerability from cvelistv5
- CWE-940 - Improper Verification of Source of a Communication Channel
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23018",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T19:38:35.023118Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:20.585Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:00:13.443Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IPv6",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ietf:ipv6:*:*:*:*:*:*:*:*",
"versionEndIncluding": "6",
"versionStartIncluding": "6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IPv4-in-IPv6 and IPv6-in-IPv6 tunneling (RFC 2473) do not require the validation or verification of the source of a network packet, allowing an attacker to spoof and route arbitrary traffic via an exposed network interface. This is a similar issue to CVE-2020-10136."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T19:51:42.363Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2473"
},
{
"url": "https://papers.mathyvanhoef.com/usenix2025-tunnels.pdf"
},
{
"url": "https://www.top10vpn.com/research/tunneling-protocol-vulnerability/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-23018",
"datePublished": "2025-01-14T00:00:00.000Z",
"dateReserved": "2025-01-10T00:00:00.000Z",
"dateUpdated": "2025-11-03T21:00:13.443Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-23019 (GCVE-0-2025-23019)
Vulnerability from cvelistv5
- CWE-940 - Improper Verification of Source of a Communication Channel
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23019",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T19:37:11.123417Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:20.419Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:00:14.906Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IPv6",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ietf:ipv6:*:*:*:*:*:*:*:*",
"versionEndIncluding": "6",
"versionStartIncluding": "6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IPv6-in-IPv4 tunneling (RFC 4213) allows an attacker to spoof and route traffic via an exposed network interface."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T19:54:56.202Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc4213"
},
{
"url": "https://papers.mathyvanhoef.com/usenix2025-tunnels.pdf"
},
{
"url": "https://www.top10vpn.com/research/tunneling-protocol-vulnerability/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-23019",
"datePublished": "2025-01-14T00:00:00.000Z",
"dateReserved": "2025-01-10T00:00:00.000Z",
"dateUpdated": "2025-11-03T21:00:14.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40820 (GCVE-0-2025-40820)
Vulnerability from cvelistv5
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
- CWE-940 - Improper Verification of Source of a Communication Channel
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40820",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:52:45.674847Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:55:23.400Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIDOOR ATD430W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIDOOR ATE530G COATED",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIDOOR ATE530S COATED",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU DIQ",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU PA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU PA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200clean, CM 8x IO-Link",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200clean, DI 16x24VDC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200clean, DIQ 16x24VDC/0,5A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, DI 16x24VDC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, DI 8x24VDC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 MF HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/MF Coupler",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Power Line Booster PLB, Base Module",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Power Line Booster PLB, Modem Module ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU CR40",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU CR60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR40",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR40",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU SR60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST40",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST40",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART CPU ST60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4200 CIM4210",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4200 CIM4210C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4300 CIM4310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212C AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215C AC/DC/RLY",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIWAREX WP231",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIWAREX WP241",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIWAREX WP251",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIWAREX WP521 ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIWAREX WP522 ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of service. The attack succeeds only if an attacker can inject IP packets with spoofed addresses at precisely timed moments, and it affects only TCP-based services."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940: Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:30.977Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-915282.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40820",
"datePublished": "2025-12-09T10:44:30.977Z",
"dateReserved": "2025-04-16T08:50:26.975Z",
"dateUpdated": "2025-12-09T15:55:23.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-42978 (GCVE-0-2025-42978)
Vulnerability from cvelistv5
- CWE-940 - Improper Verification of Source of a Communication Channel
| Vendor | Product | Version | ||
|---|---|---|---|---|
| SAP_SE | SAP NetWeaver Application Server Java |
Version: ENGINEAPI 7.50 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-42978",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T18:11:38.295391Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T18:14:00.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SAP NetWeaver Application Server Java",
"vendor": "SAP_SE",
"versions": [
{
"status": "affected",
"version": "ENGINEAPI 7.50"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe widely used component that establishes outbound TLS connections in SAP NetWeaver Application Server Java does not reliably match the hostname that is used for the connection against the wildcard hostname defined in the received certificate of remote TLS server. This might lead to the outbound connection being established to a possibly malicious remote TLS server and hence disclose information. Integrity and Availability are not impacted.\u003c/p\u003e"
}
],
"value": "The widely used component that establishes outbound TLS connections in SAP NetWeaver Application Server Java does not reliably match the hostname that is used for the connection against the wildcard hostname defined in the received certificate of remote TLS server. This might lead to the outbound connection being established to a possibly malicious remote TLS server and hence disclose information. Integrity and Availability are not impacted."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940: Improper Verification of Source of a Communication Channel",
"lang": "eng",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T00:37:44.388Z",
"orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"shortName": "sap"
},
"references": [
{
"url": "https://me.sap.com/notes/3557179"
},
{
"url": "https://url.sap/sapsecuritypatchday"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insufficiently Secure Hostname Verification for Outbound TLS Connections in SAP NetWeaver Application Server Java",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"assignerShortName": "sap",
"cveId": "CVE-2025-42978",
"datePublished": "2025-07-08T00:37:44.388Z",
"dateReserved": "2025-04-16T13:25:45.231Z",
"dateUpdated": "2025-07-08T18:14:00.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-59159 (GCVE-0-2025-59159)
Vulnerability from cvelistv5
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| SillyTavern | SillyTavern |
Version: < 1.13.4 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-59159",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-06T15:54:29.254980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T15:54:48.346Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SillyTavern",
"vendor": "SillyTavern",
"versions": [
{
"status": "affected",
"version": "\u003c 1.13.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SillyTavern is a locally installed user interface that allows users to interact with text generation large language models, image generation engines, and text-to-speech voice models. In versions prior to 1.13.4, the web user interface for SillyTavern is susceptible to DNS rebinding, allowing attackers to perform actions like install malicious extensions, read chats, inject arbitrary HTML for phishing attacks, etc. The vulnerability has been patched in the version 1.13.4 by introducing a server configuration setting that enables a validation of host names in inbound HTTP requests according to the provided list of allowed hosts: `hostWhitelist.enabled` in config.yaml file or `SILLYTAVERN_HOSTWHITELIST_ENABLED` environment variable. While the setting is disabled by default to honor a wide variety of existing user configurations and maintain backwards compatibility, existing and new users are encouraged to review their server configurations and apply necessary changes to their setup, especially if hosting over the local network while not using SSL."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.7,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-346",
"description": "CWE-346: Origin Validation Error",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940: Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T15:31:46.126Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/SillyTavern/SillyTavern/security/advisories/GHSA-7cxj-w27x-x78q",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/SillyTavern/SillyTavern/security/advisories/GHSA-7cxj-w27x-x78q"
},
{
"name": "https://github.com/SillyTavern/SillyTavern/commit/d134abd50e4a416e3b81233242583b0a23f38320",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/SillyTavern/SillyTavern/commit/d134abd50e4a416e3b81233242583b0a23f38320"
},
{
"name": "https://docs.sillytavern.app/administration/#security-checklist",
"tags": [
"x_refsource_MISC"
],
"url": "https://docs.sillytavern.app/administration/#security-checklist"
},
{
"name": "https://docs.sillytavern.app/administration/config-yaml/#host-whitelisting",
"tags": [
"x_refsource_MISC"
],
"url": "https://docs.sillytavern.app/administration/config-yaml/#host-whitelisting"
},
{
"name": "https://github.com/SillyTavern/SillyTavern/releases/tag/1.13.4",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/SillyTavern/SillyTavern/releases/tag/1.13.4"
}
],
"source": {
"advisory": "GHSA-7cxj-w27x-x78q",
"discovery": "UNKNOWN"
},
"title": "SillyTavern Web Interface Vulnerable to DNS Rebinding"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2025-59159",
"datePublished": "2025-10-06T15:31:46.126Z",
"dateReserved": "2025-09-09T15:23:16.327Z",
"dateUpdated": "2025-10-06T15:54:48.346Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-61932 (GCVE-0-2025-61932)
Vulnerability from cvelistv5
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
- CWE-940 - Improper Verification of Source of a Communication Channel
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOTEX Inc. | Lanscope Endpoint Manager (On-Premises) (Client program (MR) and Detection agent (DA)) |
Version: Ver.9.4.7.1 and earlier |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-61932",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2025-10-22",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-61932"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-22T22:20:23.471Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"name": "CISA KEV",
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-61932"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-10-22T00:00:00+00:00",
"value": "CVE-2025-61932 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Lanscope Endpoint Manager (On-Premises) (Client program (MR) and Detection agent (DA))",
"vendor": "MOTEX Inc.",
"versions": [
{
"status": "affected",
"version": "Ver.9.4.7.1 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Lanscope Endpoint Manager (On-Premises) (Client program (MR) and Detection agent (DA)) improperly verifies the origin of incoming requests, allowing an attacker to execute arbitrary code by sending specially crafted packets."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "Improper Verification of Source of a Communication Channel",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-20T07:25:39.916Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.motex.co.jp/news/notice/2025/release251020/"
},
{
"url": "https://jvn.jp/en/jp/JVN86318557/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2025-61932",
"datePublished": "2025-10-20T07:25:39.916Z",
"dateReserved": "2025-10-06T02:24:53.875Z",
"dateUpdated": "2025-10-22T22:20:23.471Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9999 (GCVE-0-2025-9999)
Vulnerability from cvelistv5
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9999",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-05T17:48:53.486647Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-05T17:49:13.857Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"modules": [
"Networking"
],
"product": "PcVue",
"vendor": "arcinfo",
"versions": [
{
"lessThanOrEqual": "16.3.3",
"status": "affected",
"version": "16.0.0",
"versionType": "cpe"
},
{
"lessThanOrEqual": "15.2.13",
"status": "affected",
"version": "15.0.0",
"versionType": "cpe"
},
{
"lessThanOrEqual": "12.0.32",
"status": "affected",
"version": "12.0.0",
"versionType": "cpe"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
"versionEndIncluding": "16.3.3",
"versionStartIncluding": "16.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
"versionEndIncluding": "15.2.13",
"versionStartIncluding": "15.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
"versionEndIncluding": "12.0.32",
"versionStartIncluding": "12.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Guillaume Andr\u00e9 (Synacktiv)"
},
{
"lang": "en",
"type": "finder",
"value": "Pierre Gertner (Synacktiv)"
}
],
"datePublic": "2025-09-04T22:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Some payload elements of the messages sent between two stations in a networking architecture are not properly checked on the receiving station allowing an attacker to execute unauthorized commands in the application."
}
],
"value": "Some payload elements of the messages sent between two stations in a networking architecture are not properly checked on the receiving station allowing an attacker to execute unauthorized commands in the application."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No POC available."
}
],
"value": "No POC available."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Not known to be exploited"
}
],
"value": "Not known to be exploited"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N/AU:Y/R:U/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"other": {
"content": {
"Automatable": "Yes",
"Exploitation": "None",
"Technical Impact": "Partial",
"version": "2.0.3"
},
"type": "SSVCv2.0"
},
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1288",
"description": "CWE-1288 Improper Validation of Consistency within Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-31T16:47:55.704Z",
"orgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"shortName": "arcinfo"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.pcvue.com/security/#SB2025-4"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003eHarden the configuration\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users\u003cbr\u003eThe system operators are highly recommended to take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:\u003cbr\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet unless required.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003eUpdate PcVue\u003c/b\u003e\u003cbr\u003e\u003cu\u003e\u003c/u\u003eThe previously announced releases, PcVue 12.0.31, 15.2.12 and 16.3.1, are affected by a regression in the client-server networking causing connection instability. If the security fix is enabled, networking packets can be falsely detected as malformed, causing a server station to force a disconnection. This issue leads to a situation where a client station may not be able to stay connected to a server station in a stable way.\u003cbr\u003e\u003cbr\u003eWe recommend users having installed PcVue 12.0.31, 15.2.12 or 16.3.1 to either roll back to an earlier stable release, or to disable this mechanism by:\u003cbr\u003e\u003cul\u003e\u003cli\u003eCheck the security alteration setting named \u0027Networking.Allow security altering configuration options\u0027,\u003c/li\u003e\u003cli\u003eSet the property \u0027Allow stations with altered security\u0027 on Nodes to Yes.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\n\n\u003cb\u003e\u003cu\u003eAvailable patches:\u003c/u\u003e\u003c/b\u003e\u003cbr\u003ePlanned in:\u003cbr\u003e\u003cul\u003e\u003cli\u003e16.3.3\u003c/li\u003e\u003cli\u003e15.2.13\u003c/li\u003e\u003cli\u003e12.0.32\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Harden the configuration\nWho should apply this recommendation: All users\nThe system operators are highly recommended to take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:\n * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet unless required.\n * Locate control system networks and remote devices behind firewalls and isolate them from business networks.\n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n\n\n\nUpdate PcVue\nThe previously announced releases, PcVue 12.0.31, 15.2.12 and 16.3.1, are affected by a regression in the client-server networking causing connection instability. If the security fix is enabled, networking packets can be falsely detected as malformed, causing a server station to force a disconnection. This issue leads to a situation where a client station may not be able to stay connected to a server station in a stable way.\n\nWe recommend users having installed PcVue 12.0.31, 15.2.12 or 16.3.1 to either roll back to an earlier stable release, or to disable this mechanism by:\n * Check the security alteration setting named \u0027Networking.Allow security altering configuration options\u0027,\n * Set the property \u0027Allow stations with altered security\u0027 on Nodes to Yes.\n\n\n\n\n\nAvailable patches:\nPlanned in:\n * 16.3.3\n * 15.2.13\n * 12.0.32"
}
],
"source": {
"advisory": "SB2025-4",
"discovery": "EXTERNAL"
},
"title": "Improper validation of payload elements",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"assignerShortName": "arcinfo",
"cveId": "CVE-2025-9999",
"datePublished": "2025-09-05T16:41:01.957Z",
"dateReserved": "2025-09-04T16:34:24.743Z",
"dateUpdated": "2025-10-31T16:47:55.704Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
Phase: Architecture and Design
Description:
- Use a mechanism that can validate the identity of the source, such as a certificate, and validate the integrity of data to ensure that it cannot be modified in transit using an Adversary-in-the-Middle (AITM) attack.
- When designing functionality of actions in the URL scheme, consider whether the action should be accessible to all mobile applications, or if an allowlist of applications to interface with is appropriate.
CAPEC-500: WebView Injection
An adversary, through a previously installed malicious application, injects code into the context of a web page displayed by a WebView component. Through the injected code, an adversary is able to manipulate the DOM tree and cookies of the page, expose sensitive information, and can launch attacks against the web application from within the web page.
CAPEC-594: Traffic Injection
An adversary injects traffic into the target's network connection. The adversary is therefore able to degrade or disrupt the connection, and potentially modify the content. This is not a flooding attack, as the adversary is not focusing on exhausting resources. Instead, the adversary is crafting a specific input to affect the system in a particular way.
CAPEC-595: Connection Reset
In this attack pattern, an adversary injects a connection reset packet to one or both ends of a target's connection. The attacker is therefore able to have the target and/or the destination server sever the connection without having to directly filter the traffic between them.
CAPEC-596: TCP RST Injection
An adversary injects one or more TCP RST packets to a target after the target has made a HTTP GET request. The goal of this attack is to have the target and/or destination web server terminate the TCP connection.