CWE-326

Inadequate Encryption Strength

The product stores or transmits sensitive data using an encryption scheme that is theoretically sound, but is not strong enough for the level of protection required.

CVE-2014-2380 (GCVE-0-2014-2380)
Vulnerability from cvelistv5
Published
2014-08-28 01:00
Modified
2025-10-31 23:11
Severity ?
CWE
Summary
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file.
Impacted products
Vendor Product Version
Schneider Electric Wonderware Information Server Portal Version: 4.0 SP1
Version: 4.5
Version: 5.0
Version: 5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:14:25.364Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wonderware Information Server Portal",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 SP1"
            },
            {
              "status": "affected",
              "version": "4.5"
            },
            {
              "status": "affected",
              "version": "5.0"
            },
            {
              "status": "affected",
              "version": "5.5"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:4.0_sp1:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:4.5:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:5.0:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:5.5:*:*:*:*:*:*:*",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitry Serebryannikov of the Positive Technologies Research Team"
        }
      ],
      "datePublic": "2014-08-26T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file."
            }
          ],
          "value": "Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-31T23:11:04.615Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-238-02"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-238-02.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has created an update for WIS web pages and \ncomponents to address the vulnerabilities listed in this advisory. \nCustomers using all versions of WIS are affected and should upgrade to \nWIS Version 5.5 and then apply the security update.\u003c/p\u003e\n\u003cp\u003eCustomers using the affected versions of WIS should set the security \nlevel settings in the Internet browser to \u201cMedium \u2013 High\u201d to minimize \nthe risks presented by these vulnerabilities. In addition, the \nWonderware Information Server Portal can be configured to use HTTPS that\n will require additional steps as documented in the products user \ndocumentation.\u003c/p\u003e\n\u003cp\u003eSchneider Electric has released a security bulletin titled \u201cMultiple \nVulnerabilities in Wonderware Information Server LFSEC00000102\u201d to \nannounce the security update, which is available at the following \nlocation:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000102.pdf\"\u003ehttps://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000102.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric has created an update for WIS web pages and \ncomponents to address the vulnerabilities listed in this advisory. \nCustomers using all versions of WIS are affected and should upgrade to \nWIS Version 5.5 and then apply the security update.\n\n\nCustomers using the affected versions of WIS should set the security \nlevel settings in the Internet browser to \u201cMedium \u2013 High\u201d to minimize \nthe risks presented by these vulnerabilities. In addition, the \nWonderware Information Server Portal can be configured to use HTTPS that\n will require additional steps as documented in the products user \ndocumentation.\n\n\nSchneider Electric has released a security bulletin titled \u201cMultiple \nVulnerabilities in Wonderware Information Server LFSEC00000102\u201d to \nannounce the security update, which is available at the following \nlocation:\n\n\n https://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000102.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-14-238-02",
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Electric Wonderware Inadequate Encryption Strength",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-2380",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-2380",
    "datePublished": "2014-08-28T01:00:00",
    "dateReserved": "2014-03-13T00:00:00",
    "dateUpdated": "2025-10-31T23:11:04.615Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-2381 (GCVE-0-2014-2381)
Vulnerability from cvelistv5
Published
2014-08-28 01:00
Modified
2025-10-31 23:19
Severity ?
CWE
Summary
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive information by reading a credential file.
Impacted products
Vendor Product Version
Schneider Electric Wonderware Information Server Portal Version: 4.0 SP1
Version: 4.5
Version: 5.0
Version: 5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:14:25.871Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wonderware Information Server Portal",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 SP1"
            },
            {
              "status": "affected",
              "version": "4.5"
            },
            {
              "status": "affected",
              "version": "5.0"
            },
            {
              "status": "affected",
              "version": "5.5"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:4.0_sp1:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:4.5:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:5.0:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:schneider_electric:wonderware_information_server_portal:5.5:*:*:*:*:*:*:*",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitry Serebryannikov of the Positive Technologies Research Team"
        }
      ],
      "datePublic": "2014-08-26T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive information by reading a credential file."
            }
          ],
          "value": "Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive information by reading a credential file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-31T23:19:54.894Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-238-02"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-238-02.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has created an update for WIS web pages and \ncomponents to address the vulnerabilities listed in this advisory. \nCustomers using all versions of WIS are affected and should upgrade to \nWIS Version 5.5 and then apply the security update.\u003c/p\u003e\n\u003cp\u003eCustomers using the affected versions of WIS should set the security \nlevel settings in the Internet browser to \u201cMedium \u2013 High\u201d to minimize \nthe risks presented by these vulnerabilities. In addition, the \nWonderware Information Server Portal can be configured to use HTTPS that\n will require additional steps as documented in the products user \ndocumentation.\u003c/p\u003e\n\u003cp\u003eSchneider Electric has released a security bulletin titled \u201cMultiple \nVulnerabilities in Wonderware Information Server LFSEC00000102\u201d to \nannounce the security update, which is available at the following \nlocation:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000102.pdf\"\u003ehttps://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000102.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric has created an update for WIS web pages and \ncomponents to address the vulnerabilities listed in this advisory. \nCustomers using all versions of WIS are affected and should upgrade to \nWIS Version 5.5 and then apply the security update.\n\n\nCustomers using the affected versions of WIS should set the security \nlevel settings in the Internet browser to \u201cMedium \u2013 High\u201d to minimize \nthe risks presented by these vulnerabilities. In addition, the \nWonderware Information Server Portal can be configured to use HTTPS that\n will require additional steps as documented in the products user \ndocumentation.\n\n\nSchneider Electric has released a security bulletin titled \u201cMultiple \nVulnerabilities in Wonderware Information Server LFSEC00000102\u201d to \nannounce the security update, which is available at the following \nlocation:\n\n\n https://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000102.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-14-238-02",
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Electric Wonderware Inadequate Encryption Strength",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-2380",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-2381",
    "datePublished": "2014-08-28T01:00:00",
    "dateReserved": "2014-03-13T00:00:00",
    "dateUpdated": "2025-10-31T23:19:54.894Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-9199 (GCVE-0-2014-9199)
Vulnerability from cvelistv5
Published
2015-01-17 02:00
Modified
2025-09-05 21:23
Severity ?
CWE
Summary
The Clorius Controls Java web client before 01.00.0009g allows remote attackers to discover credentials by sniffing the network for cleartext-equivalent traffic.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:24.875Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "A/S Java web client",
          "vendor": "Clorius Controls",
          "versions": [
            {
              "lessThanOrEqual": "01.00.0009b",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aditya Sood"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe Clorius Controls Java web client before 01.00.0009g allows remote attackers to discover credentials by sniffing the network for cleartext-equivalent traffic.\u003c/p\u003e"
            }
          ],
          "value": "The Clorius Controls Java web client before 01.00.0009g allows remote attackers to discover credentials by sniffing the network for cleartext-equivalent traffic."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-05T21:23:35.441Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-02"
        },
        {
          "url": "http://www.cloriuscontrols.com"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eClorius Controls A/S produced an update (Version 01.00.0009g) that \nmitigates this vulnerability. Contact Clorius Controls A/S for more \ninformation at:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003email@cloriuscontrols.com\u003c/a\u003e\u003c/p\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.cloriuscontrols.com\"\u003ehttp://www.cloriuscontrols.com\u003c/a\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Clorius Controls A/S produced an update (Version 01.00.0009g) that \nmitigates this vulnerability. Contact Clorius Controls A/S for more \ninformation at:\n\n\n http://www.cloriuscontrols.com"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-02",
        "discovery": "EXTERNAL"
      },
      "title": "Clorius Controls A/S ISC SCADA Insecure Java Client Inadequate Encryption Strength",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9199",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Clorius Controls Java web client before 01.00.0009g allows remote attackers to discover credentials by sniffing the network for cleartext-equivalent traffic."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9199",
    "datePublished": "2015-01-17T02:00:00",
    "dateReserved": "2014-12-02T00:00:00",
    "dateUpdated": "2025-09-05T21:23:35.441Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10125 (GCVE-0-2020-10125)
Vulnerability from cvelistv5
Published
2020-08-21 20:30
Modified
2025-11-04 19:12
Severity ?
CWE
  • CWE-326 - Inadequate Encryption Strength
Summary
NCR SelfServ ATMs running APTRA XFS 04.02.01 and 05.01.00 implement 512-bit RSA certificates to validate bunch note acceptor (BNA) software updates, which can be broken by an attacker with physical access in a sufficiently short period of time, thereby enabling the attacker to sign arbitrary files and CAB archives used to update BNA software, as well as bypass application whitelisting, resulting in the ability to execute arbitrary code.
Impacted products
Vendor Product Version
NCR SelfServ ATM Version: APTRA XFS 04.02.01
Version: APTRA XFS 05.01.00
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T19:12:03.905Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.cert.org/vuls/id/815655"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/815655"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SelfServ ATM",
          "vendor": "NCR",
          "versions": [
            {
              "status": "affected",
              "version": "APTRA XFS  04.02.01"
            },
            {
              "status": "affected",
              "version": "APTRA XFS  05.01.00"
            }
          ]
        }
      ],
      "datePublic": "2020-08-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "NCR SelfServ ATMs running APTRA XFS 04.02.01 and 05.01.00 implement 512-bit RSA certificates to validate bunch note acceptor (BNA) software updates, which can be broken by an attacker with physical access in a sufficiently short period of time, thereby enabling the attacker to sign arbitrary files and CAB archives used to update BNA software, as well as bypass application whitelisting, resulting in the ability to execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-21T20:30:40.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.cert.org/vuls/id/815655"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "DATE_PUBLIC": "2020-08-20T16:34:00.000Z",
          "ID": "CVE-2020-10125",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SelfServ ATM",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "APTRA XFS",
                            "version_value": "04.02.01"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APTRA XFS",
                            "version_value": "05.01.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NCR"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NCR SelfServ ATMs running APTRA XFS 04.02.01 and 05.01.00 implement 512-bit RSA certificates to validate bunch note acceptor (BNA) software updates, which can be broken by an attacker with physical access in a sufficiently short period of time, thereby enabling the attacker to sign arbitrary files and CAB archives used to update BNA software, as well as bypass application whitelisting, resulting in the ability to execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-326 Inadequate Encryption Strength"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.cert.org/vuls/id/815655",
              "refsource": "MISC",
              "url": "https://kb.cert.org/vuls/id/815655"
            },
            {
              "name": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_",
              "refsource": "MISC",
              "url": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2020-10125",
    "datePublished": "2020-08-21T20:30:40.398Z",
    "dateReserved": "2020-03-05T00:00:00.000Z",
    "dateUpdated": "2025-11-04T19:12:03.905Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-25685 (GCVE-0-2020-25685)
Vulnerability from cvelistv5
Published
2021-01-20 00:00
Modified
2025-11-04 19:12
Severity ?
CWE
Summary
A flaw was found in dnsmasq before version 2.83. When getting a reply from a forwarded query, dnsmasq checks in forward.c:reply_query(), which is the forwarded query that matches the reply, by only using a weak hash of the query name. Due to the weak hash (CRC32 when dnsmasq is compiled without DNSSEC, SHA-1 when it is) this flaw allows an off-path attacker to find several different domains all having the same hash, substantially reducing the number of attempts they would have to perform to forge a reply and get it accepted by dnsmasq. This is in contrast with RFC5452, which specifies that the query name is one of the attributes of a query that must be used to match a reply. This flaw could be abused to perform a DNS Cache Poisoning attack. If chained with CVE-2020-25684 the attack complexity of a successful attack is reduced. The highest threat from this vulnerability is to data integrity.
Impacted products
Vendor Product Version
n/a dnsmasq Version: dnsmasq 2.83
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T19:12:13.209Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.jsof-tech.com/disclosures/dnspooq/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1889688"
          },
          {
            "name": "FEDORA-2021-84440e87ba",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WYW3IR6APUSKOYKL5FT3ACTIHWHGQY32/"
          },
          {
            "name": "GLSA-202101-17",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202101-17"
          },
          {
            "name": "DSA-4844",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2021/dsa-4844"
          },
          {
            "name": "FEDORA-2021-2e4c3d5a9d",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/QGB7HL3OWHTLEPSMLDGOMXQKG3KM2QME/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12135-security-advisory-61"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/434904"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "dnsmasq",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "dnsmasq 2.83"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw was found in dnsmasq before version 2.83. When getting a reply from a forwarded query, dnsmasq checks in forward.c:reply_query(), which is the forwarded query that matches the reply, by only using a weak hash of the query name. Due to the weak hash (CRC32 when dnsmasq is compiled without DNSSEC, SHA-1 when it is) this flaw allows an off-path attacker to find several different domains all having the same hash, substantially reducing the number of attempts they would have to perform to forge a reply and get it accepted by dnsmasq. This is in contrast with RFC5452, which specifies that the query name is one of the attributes of a query that must be used to match a reply. This flaw could be abused to perform a DNS Cache Poisoning attack. If chained with CVE-2020-25684 the attack complexity of a successful attack is reduced. The highest threat from this vulnerability is to data integrity."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-07T00:00:00.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "url": "https://www.jsof-tech.com/disclosures/dnspooq/"
        },
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1889688"
        },
        {
          "name": "FEDORA-2021-84440e87ba",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WYW3IR6APUSKOYKL5FT3ACTIHWHGQY32/"
        },
        {
          "name": "GLSA-202101-17",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202101-17"
        },
        {
          "name": "DSA-4844",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4844"
        },
        {
          "name": "FEDORA-2021-2e4c3d5a9d",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/QGB7HL3OWHTLEPSMLDGOMXQKG3KM2QME/"
        },
        {
          "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12135-security-advisory-61"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2020-25685",
    "datePublished": "2021-01-20T00:00:00.000Z",
    "dateReserved": "2020-09-16T00:00:00.000Z",
    "dateUpdated": "2025-11-04T19:12:13.209Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2021-37209 (GCVE-0-2021-37209)
Vulnerability from cvelistv5
Published
2022-03-08 00:00
Modified
2025-08-12 11:10
CWE
  • CWE-326 - Inadequate Encryption Strength
Summary
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM i800 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM i801 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM i802 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM i803 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM M2100 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM M2200 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM M969 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RMC30 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RMC8388 V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RMC8388 V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RP110 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS1600 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS1600F Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS1600T Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS400 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS401 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS416 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS416P Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS416Pv2 V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS416Pv2 V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RS416v2 V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS416v2 V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RS8000 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS8000A Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS8000H Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS8000T Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900 (32M) V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900 (32M) V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RS900G Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900G (32M) V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900G (32M) V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RS900GP Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900L Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900M-GETS-C01 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900M-GETS-XX Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900M-STND-C01 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900M-STND-XX Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS900W Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS910 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS910L Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS910W Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS920L Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS920W Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS930L Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS930W Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS940G Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RS969 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2100 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2100 (32M) V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2100 (32M) V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG2100P Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2100P (32M) V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2100P (32M) V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG2200 Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2288 V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2288 V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG2300 V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2300 V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG2300P V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2300P V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG2488 V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG2488 V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG907R Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG908C Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG909R Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG910C Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSG920P V4.X Version: 0   < V4.3.8
Create a notification for this product.
   Siemens RUGGEDCOM RSG920P V5.X Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RSL910 Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RST2228 Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RST2228P Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RST916C Version: 0   < V5.7.0
Create a notification for this product.
   Siemens RUGGEDCOM RST916P Version: 0   < V5.7.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.378Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764417.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37209",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:15:32.474081Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:55:53.304Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i800",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i801",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i802",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i803",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC30",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RP110",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600T",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS401",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000A",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000H",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000T",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-GETS-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-GETS-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-STND-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-STND-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS969",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG907R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG908C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG909R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG910C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSL910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM i800 (All versions \u003c V4.3.8), RUGGEDCOM i801 (All versions \u003c V4.3.8), RUGGEDCOM i802 (All versions \u003c V4.3.8), RUGGEDCOM i803 (All versions \u003c V4.3.8), RUGGEDCOM M2100 (All versions \u003c V4.3.8), RUGGEDCOM M2200 (All versions \u003c V4.3.8), RUGGEDCOM M969 (All versions \u003c V4.3.8), RUGGEDCOM RMC30 (All versions \u003c V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RP110 (All versions \u003c V4.3.8), RUGGEDCOM RS1600 (All versions \u003c V4.3.8), RUGGEDCOM RS1600F (All versions \u003c V4.3.8), RUGGEDCOM RS1600T (All versions \u003c V4.3.8), RUGGEDCOM RS400 (All versions \u003c V4.3.8), RUGGEDCOM RS401 (All versions \u003c V4.3.8), RUGGEDCOM RS416 (All versions \u003c V4.3.8), RUGGEDCOM RS416P (All versions \u003c V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS8000 (All versions \u003c V4.3.8), RUGGEDCOM RS8000A (All versions \u003c V4.3.8), RUGGEDCOM RS8000H (All versions \u003c V4.3.8), RUGGEDCOM RS8000T (All versions \u003c V4.3.8), RUGGEDCOM RS900 (All versions \u003c V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS900G (All versions \u003c V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS900GP (All versions \u003c V4.3.8), RUGGEDCOM RS900L (All versions \u003c V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions \u003c V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions \u003c V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions \u003c V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions \u003c V4.3.8), RUGGEDCOM RS900W (All versions \u003c V4.3.8), RUGGEDCOM RS910 (All versions \u003c V4.3.8), RUGGEDCOM RS910L (All versions \u003c V4.3.8), RUGGEDCOM RS910W (All versions \u003c V4.3.8), RUGGEDCOM RS920L (All versions \u003c V4.3.8), RUGGEDCOM RS920W (All versions \u003c V4.3.8), RUGGEDCOM RS930L (All versions \u003c V4.3.8), RUGGEDCOM RS930W (All versions \u003c V4.3.8), RUGGEDCOM RS940G (All versions \u003c V4.3.8), RUGGEDCOM RS969 (All versions \u003c V4.3.8), RUGGEDCOM RSG2100 (All versions \u003c V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2100P (All versions \u003c V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2200 (All versions \u003c V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG907R (All versions \u003c V5.7.0), RUGGEDCOM RSG908C (All versions \u003c V5.7.0), RUGGEDCOM RSG909R (All versions \u003c V5.7.0), RUGGEDCOM RSG910C (All versions \u003c V5.7.0), RUGGEDCOM RSG920P V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG920P V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSL910 (All versions \u003c V5.7.0), RUGGEDCOM RST2228 (All versions \u003c V5.7.0), RUGGEDCOM RST2228P (All versions \u003c V5.7.0), RUGGEDCOM RST916C (All versions \u003c V5.7.0), RUGGEDCOM RST916P (All versions \u003c V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326: Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:10:51.567Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764417.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-764417.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37209",
    "datePublished": "2022-03-08T00:00:00.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-08-12T11:10:51.567Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-4333 (GCVE-0-2023-4333)
Vulnerability from cvelistv5
Published
2023-08-15 18:25
Modified
2025-11-04 16:10
Severity ?
CWE
  • CWE-326 - Inadequate Encryption Strength
Summary
Broadcom RAID Controller web interface doesn’t enforce SSL cipher ordering by server
Impacted products
Vendor Product Version
Broadcom LSI Storage Authority (LSA) Version: 0   < 7.017.011.000
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T16:10:26.180Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/resources/product-security-center"
          },
          {
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00926.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4333",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-08T19:34:27.460689Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-08T19:34:36.730Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "LSI Storage Authority (LSA)",
          "vendor": "Broadcom",
          "versions": [
            {
              "lessThan": "7.017.011.000",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Intel DCG"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Broadcom RAID Controller web interface doesn\u2019t enforce SSL cipher ordering by server"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-24T14:43:56.277Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "url": "https://www.broadcom.com/support/resources/product-security-center"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue is fixed in 7.017.011.000. For more information please contact your Broadcom representative."
            }
          ],
          "value": "This issue is fixed in 7.017.011.000. For more information please contact your Broadcom representative."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Broadcom RAID Controller web interface doesn\u2019t enforce SSL cipher ordering by server",
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2023-4333",
    "datePublished": "2023-08-15T18:25:37.222Z",
    "dateReserved": "2023-08-14T21:25:58.657Z",
    "dateUpdated": "2025-11-04T16:10:26.180Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-38867 (GCVE-0-2024-38867)
Vulnerability from cvelistv5
Published
2024-07-09 12:05
Modified
2025-08-27 20:42
CWE
  • CWE-326 - Inadequate Encryption Strength
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports.
Impacted products
Vendor Product Version
Siemens SIPROTEC 5 6MD84 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 6MD85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 6MD85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 6MD86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 6MD86 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 6MD89 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 6MU85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7KE85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7KE85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7SA82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SA84 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA86 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SA87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA87 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SD82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SD84 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD86 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SD87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD87 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ81 (CP100) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ81 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ82 (CP100) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ85 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ86 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SK82 (CP100) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 7SK82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SK85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SK85 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SL82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SL86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL86 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SL87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL87 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SS85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SS85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7ST85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7ST85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7ST86 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7SX82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7SX85 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7UM85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7UT82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT82 (CP150) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7UT85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT85 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7UT86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT86 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7UT87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT87 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7VE85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7VK87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7VK87 (CP300) Version: 0   < V9.65
Create a notification for this product.
   Siemens SIPROTEC 5 7VU85 (CP300) Version: 0   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) Version: 0   < V9.62
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) Version: 0   < V9.62
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BD-2FO Version: 0   < V9.62
Create a notification for this product.
   Siemens SIPROTEC 5 Compact 7SX800 (CP050) Version: 0   < V9.64
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-38867",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:29:09.013832Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T20:42:54.907Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T04:19:20.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-750499.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD84 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD89 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA84 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD84 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UM85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.65",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.62",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.62",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BD-2FO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.62",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Compact 7SX800 (CP050)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V9.64), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V9.65), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions \u003c V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions \u003c V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). \r\nThis could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326: Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:10.991Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-750499.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-38867",
    "datePublished": "2024-07-09T12:05:10.052Z",
    "dateReserved": "2024-06-20T12:58:59.139Z",
    "dateUpdated": "2025-08-27T20:42:54.907Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-12478 (GCVE-0-2025-12478)
Vulnerability from cvelistv5
Published
2025-10-29 16:37
Modified
2025-10-29 19:37
CWE
  • CWE-326 - Inadequate Encryption Strength
Summary
Non-Compliant TLS Configuration.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12478",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-29T19:16:17.499372Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-29T19:37:55.616Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BLU-IC2",
          "vendor": "Azure Access Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.19.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BLU-IC4",
          "vendor": "Azure Access Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.19.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Kevin Schaller"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Benjamin Lafois"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Alexi Bitsios"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Sebastian Toscano"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Dominik Schneider"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Non-Compliant TLS Configuration.\u003cp\u003eThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .\u003c/p\u003e"
            }
          ],
          "value": "Non-Compliant TLS Configuration.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 ."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-192",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-192 Protocol Analysis"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-29T16:37:47.165Z",
        "orgId": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
        "shortName": "azure-access"
      },
      "references": [
        {
          "url": "https://azure-access.com/security-advisories"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Non-Compliant TLS Configuration",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
    "assignerShortName": "azure-access",
    "cveId": "CVE-2025-12478",
    "datePublished": "2025-10-29T16:37:47.165Z",
    "dateReserved": "2025-10-29T16:36:02.981Z",
    "dateUpdated": "2025-10-29T19:37:55.616Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-36106 (GCVE-0-2025-36106)
Vulnerability from cvelistv5
Published
2025-07-21 18:08
Modified
2025-08-18 01:32
CWE
  • CWE-326 - Inadequate Encryption Strength
Summary
IBM Cognos Analytics Mobile (iOS) 1.1.0 through 1.1.22 could allow malicious actors to view and modify information coming to and from the application which could then be used to access confidential information on the device or network by using a the deprecated or misconfigured AFNetworking library at runtime.
References
Impacted products
Vendor Product Version
IBM Cognos Analytics Mobile Version: 1.1.0    1.1.22
    cpe:2.3:a:ibm:cognos_analytics_mobile:1.1.0:*:*:*:*:ios:*:*
    cpe:2.3:a:ibm:cognos_analytics_mobile:1.1.22:*:*:*:*:ios:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-36106",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T18:41:45.044508Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T18:43:15.502Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:ibm:cognos_analytics_mobile:1.1.0:*:*:*:*:ios:*:*",
            "cpe:2.3:a:ibm:cognos_analytics_mobile:1.1.22:*:*:*:*:ios:*:*"
          ],
          "defaultStatus": "unaffected",
          "platforms": [
            "iOS"
          ],
          "product": "Cognos Analytics Mobile",
          "vendor": "IBM",
          "versions": [
            {
              "lessThanOrEqual": "1.1.22",
              "status": "affected",
              "version": "1.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IBM Cognos Analytics Mobile (iOS) 1.1.0 through 1.1.22 could allow malicious actors to view and modify information coming to and from the application which could then be used to access confidential information on the device or network by using a the deprecated or misconfigured AFNetworking library at runtime."
            }
          ],
          "value": "IBM Cognos Analytics Mobile (iOS) 1.1.0 through 1.1.22 could allow malicious actors to view and modify information coming to and from the application which could then be used to access confidential information on the device or network by using a the deprecated or misconfigured AFNetworking library at runtime."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-18T01:32:49.740Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7239635"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IBM encourages customers to update their devices promptly.\u003cbr\u003e\u003cbr\u003eIBM Cognos Analytics Mobile (iOS)  1.1.0 - 1.1.22  IBM Cognos Analytics Mobile (iOS) 1.1.23\u003cbr\u003e"
            }
          ],
          "value": "IBM encourages customers to update their devices promptly.\n\nIBM Cognos Analytics Mobile (iOS)  1.1.0 - 1.1.22  IBM Cognos Analytics Mobile (iOS) 1.1.23"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IBM Cognos Analytics Mobile (iOS) information disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2025-36106",
    "datePublished": "2025-07-21T18:08:09.988Z",
    "dateReserved": "2025-04-15T21:16:16.298Z",
    "dateUpdated": "2025-08-18T01:32:49.740Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Use an encryption scheme that is currently considered to be strong by experts in the field.
CAPEC-112: Brute Force

In this attack, some asset (information, functionality, identity, etc.) is protected by a finite secret value. The attacker attempts to gain access to this asset by using trial-and-error to exhaustively explore all the possible secret values in the hope of finding the secret (or a value that is functionally equivalent) that will unlock the asset.

CAPEC-192: Protocol Analysis

An adversary engages in activities to decipher and/or decode protocol information for a network or application communication protocol used for transmitting information between interconnected nodes or systems on a packet-switched data network. While this type of analysis involves the analysis of a networking protocol inherently, it does not require the presence of an actual or physical network.

CAPEC-20: Encryption Brute Forcing

An attacker, armed with the cipher text and the encryption algorithm used, performs an exhaustive (brute force) search on the key space to determine the key that decrypts the cipher text to obtain the plaintext.

Back to CWE stats page