GCVE-1988-2026-0426
Vulnerability from gna-1988 – Published: 2026-10-02 04:57 – Updated: 2026-10-02 04:57
VLAI
EPSS
VEX
Title
[0day-rubbish] Lantronix SGX5150 9.13.0.0R7 Authenticated FsBrowseClean command injection to root RCE (7.2)
Summary
0day Rubbish Research Team is publicly disclosing a vulnerability in Lantronix
SGX5150, firmware 9.13.0.0R7, an IT/OT device server.
Type: authenticated OS command injection (CWE-78) in the FsBrowseClean AJAX
handler (0x5eea0) of /bin/ltrx_evo. A per-character filter blocks & | < ; ! $
backslash backtick and > but permits single quote, hash and newline. The path
POST parameter is concatenated into /sbin/ltrx_usb_umount '%s' and run through
/bin/sh -c as root. Sending path=x'%0a<cmd>%20%23 closes the quoted argument,
opens a new shell line carrying the attacker's command, and comments out the
trailing quote. The sink is blind.
Scoring. This finding is dual-scored, and the conditional figure is NOT
verified, which is stated rather than glossed:
- PRIMARY, adopted, 7.2 High, CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
PR:H rests on a genuine privileged web session being required.
- CONDITIONAL, NOT verified, 9.8 Critical,
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Applies only if the device
serial number is obtainable, which would make the factory administrator
password (recorded as serial-derived) no secret and the chain effectively
unauthenticated. Serial recovery was NOT verified, and neither was the
derivation itself.
- SEPARATE secondary defect, 9.8 Critical, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, reachable only where Digest
authentication is configured: the
Digest username extractor at 0xff838 verifies no nonce, realm or response, so a
forged Authorization: Digest username="admin" header alone sets the identity to
admin. This is independent of, and not additive to, the primary finding.
Scoring note. The research record attached 8.8 to the PR:H vector. That vector
computes to 7.2, not 8.8 under CVSS 3.1; this advisory recomputes from the vector
printed beside it and reports 7.2, keeping 8.8 only as a labelled PR:L
hypothetical (no lower-privileged account passing the filesystem write test was
enumerated, so it is not claimed).
Impact: root execution on an industrial gateway (ltrx_evo runs as root), giving
full read of configuration and serial traffic, arbitrary root modification,
persistent implantation, total availability loss and a pivot into segmented
networks.
Authentication: an authenticated web session satisfying
IsGroupListWritable(identity, "filesystem"); the session precondition is static
analysis, not dynamically verified.
Verification boundary, stated plainly. No physical SGX5150 hardware was used at
any point; verification is sink-faithful rather than full-stack. The character
filter, the IseUSB gate and the sink construction were replicated in a chroot of
the extracted ARM rootfs under qemu-arm-static, and the injected newline vector
passed the product's own filter and ran as root via the product's own /bin/sh and
marker owned by root:root. End-to-end HTTP against a live daemon was not
achievable, because ltrx_evo requires NVRAM state, the encrypted factory.xcr
device-serial material and a ZMQ IPC stack that could not be reconstructed
outside the device.
Full technical analysis and a reproducible proof-of-concept:
https://0day-rubbish.com/blog/lantronix-sgx5150-fsbrowseclean-command-injection
Project archive (ongoing disclosure series):
https://github.com/Exploit-Garbage/0day-Rubbish
The vendor has been notified through its published security contact. No vulnerability identifier has been assigned to
this finding yet.
--
0day Rubbish Research Team
disclosure () 0day-rubbish com
https://0day-rubbish.com
_______________________________________________
Sent through the Full Disclosure mailing list
https://nmap.org/mailman/listinfo/fulldisclosure
Web Archives & RSS: https://seclists.org/fulldisclosure/
Severity
No CVSS data available.
CWE
Assigner
References
7 references
{
"containers": {
"cna": {
"affected": [
{
"product": "SGX5150",
"vendor": "Lantronix",
"versions": [
{
"status": "affected",
"version": "unknown"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "disclosure via Fulldisclosure"
}
],
"descriptions": [
{
"lang": "en",
"value": "0day Rubbish Research Team is publicly disclosing a vulnerability in Lantronix\nSGX5150, firmware 9.13.0.0R7, an IT/OT device server.\n\nType: authenticated OS command injection (CWE-78) in the FsBrowseClean AJAX\nhandler (0x5eea0) of /bin/ltrx_evo. A per-character filter blocks \u0026 | \u003c ; ! $\nbackslash backtick and \u003e but permits single quote, hash and newline. The path\nPOST parameter is concatenated into /sbin/ltrx_usb_umount \u0027%s\u0027 and run through\n/bin/sh -c as root. Sending path=x\u0027%0a\u003ccmd\u003e%20%23 closes the quoted argument,\nopens a new shell line carrying the attacker\u0027s command, and comments out the\ntrailing quote. The sink is blind.\n\nScoring. This finding is dual-scored, and the conditional figure is NOT\nverified, which is stated rather than glossed:\n- PRIMARY, adopted, 7.2 High, CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.\n PR:H rests on a genuine privileged web session being required.\n- CONDITIONAL, NOT verified, 9.8 Critical,\n CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Applies only if the device\n serial number is obtainable, which would make the factory administrator\n password (recorded as serial-derived) no secret and the chain effectively\n unauthenticated. Serial recovery was NOT verified, and neither was the\n derivation itself.\n- SEPARATE secondary defect, 9.8 Critical, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, reachable only where Digest \nauthentication is configured: the\n Digest username extractor at 0xff838 verifies no nonce, realm or response, so a\n forged Authorization: Digest username=\"admin\" header alone sets the identity to\n admin. This is independent of, and not additive to, the primary finding.\n\nScoring note. The research record attached 8.8 to the PR:H vector. That vector\ncomputes to 7.2, not 8.8 under CVSS 3.1; this advisory recomputes from the vector\nprinted beside it and reports 7.2, keeping 8.8 only as a labelled PR:L\nhypothetical (no lower-privileged account passing the filesystem write test was\nenumerated, so it is not claimed).\n\nImpact: root execution on an industrial gateway (ltrx_evo runs as root), giving\nfull read of configuration and serial traffic, arbitrary root modification,\npersistent implantation, total availability loss and a pivot into segmented\nnetworks.\n\nAuthentication: an authenticated web session satisfying\nIsGroupListWritable(identity, \"filesystem\"); the session precondition is static\nanalysis, not dynamically verified.\n\nVerification boundary, stated plainly. No physical SGX5150 hardware was used at\nany point; verification is sink-faithful rather than full-stack. The character\nfilter, the IseUSB gate and the sink construction were replicated in a chroot of\nthe extracted ARM rootfs under qemu-arm-static, and the injected newline vector\npassed the product\u0027s own filter and ran as root via the product\u0027s own /bin/sh and\nmarker owned by root:root. End-to-end HTTP against a live daemon was not\nachievable, because ltrx_evo requires NVRAM state, the encrypted factory.xcr\ndevice-serial material and a ZMQ IPC stack that could not be reconstructed\noutside the device.\n\nFull technical analysis and a reproducible proof-of-concept:\n https://0day-rubbish.com/blog/lantronix-sgx5150-fsbrowseclean-command-injection\n\nProject archive (ongoing disclosure series):\n https://github.com/Exploit-Garbage/0day-Rubbish\n\nThe vendor has been notified through its published security contact. No vulnerability identifier has been assigned to\nthis finding yet.\n\n--\n0day Rubbish Research Team\ndisclosure () 0day-rubbish com\nhttps://0day-rubbish.com\n_______________________________________________\nSent through the Full Disclosure mailing list\nhttps://nmap.org/mailman/listinfo/fulldisclosure\nWeb Archives \u0026 RSS: https://seclists.org/fulldisclosure/"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T04:57:33Z",
"orgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
"shortName": "VULNARCHIVE"
},
"references": [
{
"tags": [
"technical-description",
"exploit"
],
"url": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/74"
},
{
"tags": [
"technical-description"
],
"url": "https://seclists.org/fulldisclosure/2026/Sep/74"
},
{
"url": "https://0day-rubbish.com"
},
{
"url": "https://0day-rubbish.com/blog/lantronix-sgx5150-fsbrowseclean-command-injection"
},
{
"url": "https://github.com/Exploit-Garbage/0day-Rubbish"
},
{
"url": "https://nmap.org/mailman/listinfo/fulldisclosure"
},
{
"url": "https://seclists.org/fulldisclosure/"
}
],
"source": {
"defect": [
"https://seclists.org/fulldisclosure/2026/Sep/74"
],
"discovery": "EXTERNAL"
},
"title": "[0day-rubbish] Lantronix SGX5150 9.13.0.0R7 Authenticated FsBrowseClean command injection to root RCE (7.2)",
"x_gcve": [
{
"recordType": "advisory",
"relationships": [],
"vulnId": "GCVE-1988-2026-0426",
"x_vulnarchive": {
"archiveUrl": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/74",
"automated": true,
"contentSha256": "d6670722639ae6e018f6457e300ad3ae04f054ec188213319fd7740f05872762",
"evidenceScore": 11,
"messageId": "",
"originalUrl": "https://seclists.org/fulldisclosure/2026/Sep/74",
"policy": "vulnarchive-1",
"sourceFormat": "text/html",
"sourcePublishedAt": "2026-09-23T04:54:13Z"
}
}
]
}
},
"cveMetadata": {
"assignerOrgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
"assignerShortName": "VULNARCHIVE",
"datePublished": "2026-10-02T04:57:33Z",
"dateUpdated": "2026-10-02T04:57:33Z",
"state": "PUBLISHED",
"vulnId": "GCVE-1988-2026-0426"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-91191 (GCVE-0-2026-91191)
Vulnerability from nvd – Published: 2026-09-29 21:04 – Updated: 2026-09-30 15:28
VLAI
EPSS
VEX
Title
Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature
Summary
The device's update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-30 15:03 UTC
CWE
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lantronix | G520 Series |
Affected:
2.6.0.4R6 stable
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-91191",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-30T15:03:47.430624Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-30T15:28:15.769Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "G520 Series",
"vendor": "Lantronix",
"versions": [
{
"status": "affected",
"version": "2.6.0.4R6 stable"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ievgen Bondarenko reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
}
],
"value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:04:52.546Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
},
{
"url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003c/div\u003e"
}
],
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
}
],
"source": {
"advisory": "ICSA-26-272-01",
"discovery": "EXTERNAL"
},
"title": "Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-91191",
"datePublished": "2026-09-29T21:04:52.546Z",
"dateReserved": "2026-09-17T19:24:31.384Z",
"dateUpdated": "2026-09-30T15:28:15.769Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-84409 (GCVE-0-2026-84409)
Vulnerability from nvd – Published: 2026-09-29 21:02 – Updated: 2026-09-30 15:28
VLAI
EPSS
VEX
Title
Lantronix G520 Series Cellular Gateway Cross-site Scripting
Summary
The device's update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker‑controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system‑level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-30 15:03 UTC
CWE
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lantronix | G520 Series |
Affected:
2.6.0.4R6 stable
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-84409",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-30T15:03:34.956731Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-30T15:28:15.903Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "G520 Series",
"vendor": "Lantronix",
"versions": [
{
"status": "affected",
"version": "2.6.0.4R6 stable"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ievgen Bondarenko reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
}
],
"value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:02:09.711Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
},
{
"url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
}
],
"source": {
"advisory": "ICSA-26-272-01",
"discovery": "EXTERNAL"
},
"title": "Lantronix G520 Series Cellular Gateway Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-84409",
"datePublished": "2026-09-29T21:02:09.711Z",
"dateReserved": "2026-09-17T19:24:31.388Z",
"dateUpdated": "2026-09-30T15:28:15.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80156 (GCVE-0-2026-80156)
Vulnerability from nvd – Published: 2026-09-22 15:23 – Updated: 2026-09-24 19:11
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass
Summary
Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-23 15:42 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.5
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:42:01.037508Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:42:10.927Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device\u0027s filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:11:50.183Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-arbitrary-file-write-via-upload-filename-validation-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80156",
"datePublished": "2026-09-22T15:23:24.784Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:11:50.183Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80155 (GCVE-0-2026-80155)
Vulnerability from nvd – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:11
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation
Summary
Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:42 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.5
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80155",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:42:37.923706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:43:00.393Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:11:02.375Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-unauthenticated-authentication-bypass-via-snprintf-path-truncation"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80155",
"datePublished": "2026-09-22T15:22:57.059Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:11:02.375Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80154 (GCVE-0-2026-80154)
Vulnerability from nvd – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:10
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass
Summary
All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
Severity
9.6 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 17:22 UTC
CWE
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:31.916185Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:14.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.9,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:10:15.088Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-predictable-session-token-with-validation-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80154",
"datePublished": "2026-09-22T15:22:33.748Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:10:15.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80152 (GCVE-0-2026-80152)
Vulnerability from nvd – Published: 2026-09-22 15:22 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:49 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.3
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:49:36.568082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:52:24.941Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:54.538Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-script-schedule"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80152",
"datePublished": "2026-09-22T15:22:09.965Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-26T13:29:54.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80151 (GCVE-0-2026-80151)
Vulnerability from nvd – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-25 23:35 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.3
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80151",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-25T23:35:00.564701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-25T23:35:17.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:53.855Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-nfs-download"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80151",
"datePublished": "2026-09-22T15:21:45.246Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:53.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80150 (GCVE-0-2026-80150)
Vulnerability from nvd – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-23 15:46 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:46:31.921852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:46:38.366Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:53.179Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webtelnet-ssrf-via-rooturl-parameter"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80150",
"datePublished": "2026-09-22T15:21:22.223Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:53.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80149 (GCVE-0-2026-80149)
Vulnerability from nvd – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:41 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80149",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:41:42.950532Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:42:08.210Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:52.466Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-rooturl-parameter"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80149",
"datePublished": "2026-09-22T15:20:57.823Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:52.466Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80148 (GCVE-0-2026-80148)
Vulnerability from nvd – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 17:22 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80148",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:22.576164Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:20.907Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:51.780Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-username-truncation"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80148",
"datePublished": "2026-09-22T15:20:33.864Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:51.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80147 (GCVE-0-2026-80147)
Vulnerability from nvd – Published: 2026-09-22 15:20 – Updated: 2026-09-24 19:04
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 16:02 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80147",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T16:02:05.783698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T16:04:04.161Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:04:09.218Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80147",
"datePublished": "2026-09-22T15:20:01.691Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:04:09.218Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80146 (GCVE-0-2026-80146)
Vulnerability from nvd – Published: 2026-09-22 15:19 – Updated: 2026-09-25 23:34
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-25 23:33 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80146",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-25T23:33:56.909340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-25T23:34:09.518Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:03:26.826Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-read"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80146",
"datePublished": "2026-09-22T15:19:38.818Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-25T23:34:09.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80145 (GCVE-0-2026-80145)
Vulnerability from nvd – Published: 2026-09-22 15:18 – Updated: 2026-09-24 19:02
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-23 15:47 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80145",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:47:50.948392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:47:57.416Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:15.483Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80145",
"datePublished": "2026-09-22T15:18:34.859Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:15.483Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80144 (GCVE-0-2026-80144)
Vulnerability from nvd – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:43 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80144",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:43:42.780303Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:43:55.512Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:33.612Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-write"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80144",
"datePublished": "2026-09-22T15:17:45.543Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:33.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80143 (GCVE-0-2026-80143)
Vulnerability from nvd – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 17:22 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:12.191184Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:26.836Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:44.035Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-read"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80143",
"datePublished": "2026-09-22T15:17:21.739Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:44.035Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-91191 (GCVE-0-2026-91191)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:04 – Updated: 2026-09-30 15:28
VLAI
EPSS
VEX
Title
Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature
Summary
The device's update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-30 15:03 UTC
CWE
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lantronix | G520 Series |
Affected:
2.6.0.4R6 stable
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-91191",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-30T15:03:47.430624Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-30T15:28:15.769Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "G520 Series",
"vendor": "Lantronix",
"versions": [
{
"status": "affected",
"version": "2.6.0.4R6 stable"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ievgen Bondarenko reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
}
],
"value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:04:52.546Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
},
{
"url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003c/div\u003e"
}
],
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
}
],
"source": {
"advisory": "ICSA-26-272-01",
"discovery": "EXTERNAL"
},
"title": "Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-91191",
"datePublished": "2026-09-29T21:04:52.546Z",
"dateReserved": "2026-09-17T19:24:31.384Z",
"dateUpdated": "2026-09-30T15:28:15.769Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-84409 (GCVE-0-2026-84409)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:02 – Updated: 2026-09-30 15:28
VLAI
EPSS
VEX
Title
Lantronix G520 Series Cellular Gateway Cross-site Scripting
Summary
The device's update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker‑controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system‑level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-30 15:03 UTC
CWE
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lantronix | G520 Series |
Affected:
2.6.0.4R6 stable
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-84409",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-30T15:03:34.956731Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-30T15:28:15.903Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "G520 Series",
"vendor": "Lantronix",
"versions": [
{
"status": "affected",
"version": "2.6.0.4R6 stable"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ievgen Bondarenko reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
}
],
"value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:02:09.711Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
},
{
"url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
}
],
"source": {
"advisory": "ICSA-26-272-01",
"discovery": "EXTERNAL"
},
"title": "Lantronix G520 Series Cellular Gateway Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-84409",
"datePublished": "2026-09-29T21:02:09.711Z",
"dateReserved": "2026-09-17T19:24:31.388Z",
"dateUpdated": "2026-09-30T15:28:15.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80156 (GCVE-0-2026-80156)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:23 – Updated: 2026-09-24 19:11
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass
Summary
Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-23 15:42 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.5
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:42:01.037508Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:42:10.927Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device\u0027s filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:11:50.183Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-arbitrary-file-write-via-upload-filename-validation-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80156",
"datePublished": "2026-09-22T15:23:24.784Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:11:50.183Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80155 (GCVE-0-2026-80155)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:11
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation
Summary
Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:42 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.5
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80155",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:42:37.923706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:43:00.393Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:11:02.375Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-unauthenticated-authentication-bypass-via-snprintf-path-truncation"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80155",
"datePublished": "2026-09-22T15:22:57.059Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:11:02.375Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80154 (GCVE-0-2026-80154)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:10
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass
Summary
All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
Severity
9.6 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 17:22 UTC
CWE
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:31.916185Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:14.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.9,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:10:15.088Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-predictable-session-token-with-validation-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80154",
"datePublished": "2026-09-22T15:22:33.748Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:10:15.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80152 (GCVE-0-2026-80152)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:49 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.3
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:49:36.568082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:52:24.941Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:54.538Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-script-schedule"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80152",
"datePublished": "2026-09-22T15:22:09.965Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-26T13:29:54.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80151 (GCVE-0-2026-80151)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-25 23:35 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.3
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80151",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-25T23:35:00.564701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-25T23:35:17.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:53.855Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-nfs-download"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80151",
"datePublished": "2026-09-22T15:21:45.246Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:53.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80150 (GCVE-0-2026-80150)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-23 15:46 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:46:31.921852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:46:38.366Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:53.179Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webtelnet-ssrf-via-rooturl-parameter"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80150",
"datePublished": "2026-09-22T15:21:22.223Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:53.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80149 (GCVE-0-2026-80149)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:41 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80149",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:41:42.950532Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:42:08.210Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:52.466Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-rooturl-parameter"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80149",
"datePublished": "2026-09-22T15:20:57.823Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:52.466Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80148 (GCVE-0-2026-80148)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation
Summary
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 17:22 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80148",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:22.576164Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:20.907Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:51.780Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-username-truncation"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80148",
"datePublished": "2026-09-22T15:20:33.864Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:51.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80147 (GCVE-0-2026-80147)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:20 – Updated: 2026-09-24 19:04
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 16:02 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80147",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T16:02:05.783698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T16:04:04.161Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:04:09.218Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80147",
"datePublished": "2026-09-22T15:20:01.691Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:04:09.218Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80146 (GCVE-0-2026-80146)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:19 – Updated: 2026-09-25 23:34
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-25 23:33 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80146",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-25T23:33:56.909340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-25T23:34:09.518Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:03:26.826Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-read"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80146",
"datePublished": "2026-09-22T15:19:38.818Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-25T23:34:09.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80145 (GCVE-0-2026-80145)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:18 – Updated: 2026-09-24 19:02
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-23 15:47 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80145",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:47:50.948392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:47:57.416Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:15.483Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80145",
"datePublished": "2026-09-22T15:18:34.859Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:15.483Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80144 (GCVE-0-2026-80144)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
VLAI
EPSS
VEX
Title
Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 15:43 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80144",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:43:42.780303Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:43:55.512Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:33.612Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-write"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80144",
"datePublished": "2026-09-22T15:17:45.543Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:33.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}