Refine your search
1 vulnerability found for by Autodesk
CVE-2025-10885 (GCVE-0-2025-10885)
Vulnerability from cvelistv5
Published
2025-11-06 17:01
Modified
2025-11-06 17:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-250 - Execution with Unnecessary Privileges
Summary
A maliciously crafted file, when executed on the victim's machine, can lead to privilege escalation to NT AUTHORITY/SYSTEM due to an insufficient validation of loaded binaries. An attacker with local and low-privilege access could exploit this to execute code as SYSTEM.
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10885",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-06T17:27:21.398064Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-06T17:27:39.347Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:autodesk:installer:2.18:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "Installer",
"vendor": "Autodesk",
"versions": [
{
"lessThan": "2.19",
"status": "affected",
"version": "2.18",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A maliciously crafted file, when executed on the victim\u0027s machine, can lead to privilege escalation to NT AUTHORITY/SYSTEM due to an insufficient validation of loaded binaries. An attacker with local and low-privilege access could exploit this to execute code as SYSTEM.\u003cbr\u003e"
}
],
"value": "A maliciously crafted file, when executed on the victim\u0027s machine, can lead to privilege escalation to NT AUTHORITY/SYSTEM due to an insufficient validation of loaded binaries. An attacker with local and low-privilege access could exploit this to execute code as SYSTEM."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250 Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-06T17:58:04.357Z",
"orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
"shortName": "autodesk"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://emsfs.autodesk.com/utility/odis/1/installer/latest/AdODIS-installer.exe"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2025-0022"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Privilege Escalation Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
"assignerShortName": "autodesk",
"cveId": "CVE-2025-10885",
"datePublished": "2025-11-06T17:01:19.327Z",
"dateReserved": "2025-09-23T15:29:52.416Z",
"dateUpdated": "2025-11-06T17:58:04.357Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}