All the vulnerabilites related to Iocharger - Iocharger firmware for AC models
cve-2024-43662
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 15:08
Severity ?
EPSS score ?
Summary
The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it.
Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43662/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-43662", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:07:52.620397Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T15:08:01.416Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The \u0026lt;redacted\u0026gt;.exe or \u0026lt;redacted\u0026gt;.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt;.exe or \u0026lt;redacted\u0026gt;.exe CGI binary and upload the file, or convince a user with such access to upload it.\u003cbr\u003e\u003cbr\u003eImpact: Low \u2013 The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.\u003cbr\u003e\u003cbr\u003eCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "The \u003credacted\u003e.exe or \u003credacted\u003e.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate \u2013 An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the \u003credacted\u003e.exe or \u003credacted\u003e.exe CGI binary and upload the file, or convince a user with such access to upload it.\n\nImpact: Low \u2013 The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.\n\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-165", "descriptions": [ { "lang": "en", "value": "CAPEC-165 File Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 5.3, "baseSeverity": "MEDIUM", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "LOW", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-862", "description": "CWE-862 Missing Authorization", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A01", "lang": "en" } ] }, { "descriptions": [ { "description": "OWASP-A03", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:45.624Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43662/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated arbitrary file upload to /tmp/ and /tmp/upload/", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43662", "datePublished": "2025-01-09T07:56:45.624Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T15:08:01.416Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43650
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 15:09
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects firmware versions before 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43650/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-43650", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:09:01.310561Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T15:09:57.625Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\u003cbr\u003e\u003cbr\u003eThis issue affects\u0026nbsp; firmware versions before 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to \"pivot\" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y)." } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\n\nThis issue affects\u00a0 firmware versions before 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to \"pivot\" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:45.504Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43650/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43650", "datePublished": "2025-01-09T07:56:45.504Z", "dateReserved": "2024-08-14T09:27:41.767Z", "dateUpdated": "2025-01-09T15:09:57.625Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43655
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 15:12
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43655/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-43655", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:11:43.639526Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T15:12:19.472Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:45.279Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43655/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Any authenticated users can execute OS commands as root using the \u003credacted\u003e.sh CGI script.", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43655", "datePublished": "2025-01-09T07:56:45.279Z", "dateReserved": "2024-08-14T09:27:41.768Z", "dateUpdated": "2025-01-09T15:12:19.472Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43651
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 15:21
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43651/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-43651", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:20:15.887605Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T15:21:03.613Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 241207101\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification:\u0026nbsp;Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially \"pivot\" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y)." } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC models before version 241207101\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification:\u00a0Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially \"pivot\" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:47.394Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43651/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43651", "datePublished": "2025-01-09T07:56:47.394Z", "dateReserved": "2024-08-14T09:27:41.767Z", "dateUpdated": "2025-01-09T15:21:03.613Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43660
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:38
Severity ?
EPSS score ?
Summary
The CGI script <redacted>.sh can be used to download any file on the filesystem.
This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood: High, but credentials required.
Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43660/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43660", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:37:36.870610Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:38:13.440Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The CGI script \u0026lt;redacted\u0026gt;.sh can be used to download any file on the filesystem.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers beforeversion 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: High, but credentials required.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.\u003cbr\u003e\u003cbr\u003eCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y\u003cbr\u003eCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "The CGI script \u003credacted\u003e.sh can be used to download any file on the filesystem.\n\nThis issue affects Iocharger firmware for AC model chargers beforeversion 24120701.\n\nLikelihood: High, but credentials required.\n\nImpact: Critical \u2013 The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.\n\nCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-1", "descriptions": [ { "lang": "en", "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 7.1, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-552", "description": "CWE-552 Files or Directories Accessible to External Parties", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:46.841Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43660/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Arbitrary file download using \u003credacted\u003e.sh", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43660", "datePublished": "2025-01-09T07:56:46.841Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T14:38:13.440Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43658
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 15:22
Severity ?
EPSS score ?
Summary
Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files
This issue affects Iocharger firmware for AC model before firmware version 25010801.
Likelihood: High, but requires authentication
Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43658/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 25010801 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-43658", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:21:29.851527Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T15:22:45.477Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "25010801", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files\u003cbr\u003eThis issue affects Iocharger firmware for AC model before firmware version 25010801.\u003cbr\u003e\u003cbr\u003eLikelihood: High, but requires authentication\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (V\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVC:N/VI:H/VA:H\u003c/span\u003e), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files\nThis issue affects Iocharger firmware for AC model before firmware version 25010801.\n\nLikelihood: High, but requires authentication\n\nImpact: Critical \u2013 The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-165", "descriptions": [ { "lang": "en", "value": "CAPEC-165 File Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 7.2, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-27", "description": "CWE-27 Patch traversal", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-73", "description": "CWE-73 External Control of File Name or Path", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:47.273Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43658/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Using the \u003credacted\u003e action or \u003credacted\u003e.sh script, arbitrary files and directories can be deleted using directory traversal.", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43658", "datePublished": "2025-01-09T07:56:47.273Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T15:22:45.477Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43659
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:48
Severity ?
EPSS score ?
Summary
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.
This issue affects Iocharger firmware for AC models before firmware version 25010801.
The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.
Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.
Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43659/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 25010801 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43659", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:48:10.199874Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:48:39.535Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "25010801", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "After gaining access to the firmware of a charging station, a file at \u0026lt;redacted\u0026gt; can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before firmware version 25010801. \u003cbr\u003e\u003cbr\u003eThe issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using \u0026lt;redacted\u0026gt;.sh) to gain access to the \u0026lt;redacted\u0026gt;.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System \u2192 Custom page.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the \"super user\" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "After gaining access to the firmware of a charging station, a file at \u003credacted\u003e can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.\n\nThis issue affects Iocharger firmware for AC models before firmware version 25010801. \n\nThe issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.\n\nLikelihood: Moderate \u2013 The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using \u003credacted\u003e.sh) to gain access to the \u003credacted\u003e.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.\n\nImpact: Critical \u2013 All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System \u2192 Custom page.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the \"super user\" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-653", "descriptions": [ { "lang": "en", "value": "CAPEC-653: Use of Known Operating System Credentials" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NO", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 8.3, "baseSeverity": "HIGH", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/S:P/AU:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-256", "description": "CWE-256 Plaintext Storage of a Password", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-1391", "description": "CWE-1391 Use of Weak Credentials", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-1393", "description": "CWE-1393 Use of Default Password", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:45.847Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43659/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Plaintext default credentials in firmware", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43659", "datePublished": "2025-01-09T07:56:45.847Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T14:48:39.535Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43656
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:50
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43656/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43656", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:49:55.938365Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:50:41.207Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 It might be difficult for an attacker to identify the file structure of the \u0026lt;redated\u0026gt; directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 It might be difficult for an attacker to identify the file structure of the \u003credated\u003e directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:45.743Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43656/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "A backup can be manipulated and then restored to create arbitrary files inside the \u003credacted\u003e directory. A CGI script can be added to the web directory this way, allowing for full remote code execution.", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43656", "datePublished": "2025-01-09T07:56:45.743Z", "dateReserved": "2024-08-14T09:27:41.768Z", "dateUpdated": "2025-01-09T14:50:41.207Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43649
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:36
Severity ?
EPSS score ?
Summary
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43649/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43649", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:35:10.473442Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:36:23.194Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Authenticated command injection in the filename of a \u0026lt;redacted\u0026gt;.exe request leads to remote code execution as the root user.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u0026lt;redacted\u0026gt; fields. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a payload.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification:\u0026nbsp;This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y)." } ], "value": "Authenticated command injection in the filename of a \u003credacted\u003e.exe request leads to remote code execution as the root user.\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u003credacted\u003e fields. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a payload.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification:\u00a0This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:46.982Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43649/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated command injection via \u003credacted\u003e.exe \u003credacted\u003e parameter", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43649", "datePublished": "2025-01-09T07:56:46.982Z", "dateReserved": "2024-08-14T09:27:41.767Z", "dateUpdated": "2025-01-09T14:36:23.194Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43648
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:46
Severity ?
EPSS score ?
Summary
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43648/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43648", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:45:36.579487Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:46:04.780Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Command injection in the \u0026lt;redacted\u0026gt; parameter of a \u0026lt;redacted\u0026gt;.exe request leads to remote code execution as the root user.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u0026lt;redacted\u0026gt; fields. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a payload.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).\u0026nbsp; A compromised charger can be used to \"pivot\" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H).\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBecause this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (\u003c/span\u003eS:P). The attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Command injection in the \u003credacted\u003e parameter of a \u003credacted\u003e.exe request leads to remote code execution as the root user.\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u003credacted\u003e fields. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a payload.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).\u00a0 A compromised charger can be used to \"pivot\" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H).\u00a0Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:46.114Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43648/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated command injection via \u003credacted\u003e.exe \u003credacted\u003e parameter", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43648", "datePublished": "2025-01-09T07:56:46.114Z", "dateReserved": "2024-08-14T09:27:41.767Z", "dateUpdated": "2025-01-09T14:46:04.780Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43661
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:41
Severity ?
EPSS score ?
Summary
The <redacted>.so library, which is used by <redacted>, is
vulnerable to a buffer overflow in the code that handles the deletion
of certificates. This buffer overflow can be triggered by providing a
long file path to the <redacted> action of the <redacted>.exe CGI binary or
to the <redacted>.sh CGI script. This binary or script will write this
file path to <redacted>, which is then
read by <redacted>.so
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – An attacker will have to find this exploit by
either obtaining the binaries involved in this vulnerability, or by trial
and error. Furthermore, the attacker will need a (low privilege)
account to gain access to the <redacted>.exe CGI binary or <redacted>.sh
script to trigger the vulnerability, or convince a user with such access
send an HTTP request that triggers it.
Impact: High – The <redacted> process, which we assume is
responsible for OCPP communication, will keep crashing after
performing the exploit. This happens because the buffer overflow
causes the process to segfault before
<redacted> is removed. This means that,
even though <redacted> is automatically restarted, it will crash
again as soon as it tries to parse the text file.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43661/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43661", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:40:55.906992Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:41:21.642Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The \u0026lt;redacted\u0026gt;.so library, which is used by \u0026lt;redacted\u0026gt;, is\nvulnerable to a buffer overflow in the code that handles the deletion\nof certificates. This buffer overflow can be triggered by providing a\nlong file path to the \u0026lt;redacted\u0026gt; action of the \u0026lt;redacted\u0026gt;.exe CGI binary or\nto the \u0026lt;redacted\u0026gt;.sh CGI script. This binary or script will write this\nfile path to \u0026lt;redacted\u0026gt;, which is then\nread by \u0026lt;redacted\u0026gt;.so\n\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 An attacker will have to find this exploit by\neither obtaining the binaries involved in this vulnerability, or by trial\nand error. Furthermore, the attacker will need a (low privilege)\naccount to gain access to the \u0026lt;redacted\u0026gt;.exe CGI binary or \u0026lt;redacted\u0026gt;.sh\nscript to trigger the vulnerability, or convince a user with such access\nsend an HTTP request that triggers it.\n\u003cbr\u003e\u003cbr\u003eImpact: High \u2013 The \u0026lt;redacted\u0026gt; process, which we assume is\nresponsible for OCPP communication, will keep crashing after\nperforming the exploit. This happens because the buffer overflow\ncauses the process to segfault before\n\u0026lt;redacted\u0026gt; is removed. This means that,\neven though \u0026lt;redacted\u0026gt; is automatically restarted, it will crash\nagain as soon as it tries to parse the text file.\u003cbr\u003e\u003cbr\u003eCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).\u003cbr\u003e" } ], "value": "The \u003credacted\u003e.so library, which is used by \u003credacted\u003e, is\nvulnerable to a buffer overflow in the code that handles the deletion\nof certificates. This buffer overflow can be triggered by providing a\nlong file path to the \u003credacted\u003e action of the \u003credacted\u003e.exe CGI binary or\nto the \u003credacted\u003e.sh CGI script. This binary or script will write this\nfile path to \u003credacted\u003e, which is then\nread by \u003credacted\u003e.so\n\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate \u2013 An attacker will have to find this exploit by\neither obtaining the binaries involved in this vulnerability, or by trial\nand error. Furthermore, the attacker will need a (low privilege)\naccount to gain access to the \u003credacted\u003e.exe CGI binary or \u003credacted\u003e.sh\nscript to trigger the vulnerability, or convince a user with such access\nsend an HTTP request that triggers it.\n\n\nImpact: High \u2013 The \u003credacted\u003e process, which we assume is\nresponsible for OCPP communication, will keep crashing after\nperforming the exploit. This happens because the buffer overflow\ncauses the process to segfault before\n\u003credacted\u003e is removed. This means that,\neven though \u003credacted\u003e is automatically restarted, it will crash\nagain as soon as it tries to parse the text file.\n\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I)." } ], "impacts": [ { "capecId": "CAPEC-607", "descriptions": [ { "lang": "en", "value": "CAPEC-607 Obstruction" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "IRRECOVERABLE", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 7.1, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/AU:Y/R:I", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Exploit Non-Production Interfaces", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:46.514Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43661/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Buffer overflow in \u003credacted\u003e.so leads to DoS of OCPP service", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43661", "datePublished": "2025-01-09T07:56:46.514Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T14:41:21.642Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43654
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:33
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43654/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 25010801 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43654", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:32:43.409061Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:33:30.319Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "25010801", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\u003cbr\u003eThis issue affects all Iocharger AC EV charger models on a firmware version before 25010801.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\nThis issue affects all Iocharger AC EV charger models on a firmware version before 25010801.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:47.131Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43654/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43654", "datePublished": "2025-01-09T07:56:47.131Z", "dateReserved": "2024-08-14T09:27:41.768Z", "dateUpdated": "2025-01-09T14:33:30.319Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43663
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:47
Severity ?
EPSS score ?
Summary
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.
Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43663/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43663", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:47:03.073105Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:47:32.866Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: High \u2013 Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.\u003cbr\u003e\u003cbr\u003eImpact: Low \u2013 Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.\u003cbr\u003e\u003cbr\u003eCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect\u0026nbsp; this vulnerability to have a safety impact. The attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.\n\nLikelihood: High \u2013 Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.\n\nImpact: Low \u2013 Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.\n\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect\u00a0 this vulnerability to have a safety impact. The attack can be automated (AU:Y)." } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "AUTOMATIC", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 5.3, "baseSeverity": "MEDIUM", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/AU:Y/R:A", "version": "4.0", "vulnAvailabilityImpact": "LOW", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:45.961Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43663/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Buffer overflow vulnerabilities in CGI scripts lead to segfault", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43663", "datePublished": "2025-01-09T07:56:45.961Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T14:47:32.866Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43653
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:40
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43653/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43653", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:39:24.235683Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:40:21.083Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u0026nbsp; allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u00a0 allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:46.647Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43653/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43653", "datePublished": "2025-01-09T07:56:46.647Z", "dateReserved": "2024-08-14T09:27:41.767Z", "dateUpdated": "2025-01-09T14:40:21.083Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43657
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:44
Severity ?
EPSS score ?
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory | |
https://csirt.divd.nl/CVE-2024-43657/ | third-party-advisory | |
https://iocharger.com | product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Iocharger | Iocharger firmware for AC models |
Version: 0 < 2024120701 |
|
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-43657", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T14:43:42.626573Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T14:44:32.880Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "2024120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e" } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-09T07:56:46.268Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43657/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "When uploading new firmware, a shell script inside a firmware file is executed during its processing. This can be used to craft a custom firmware file with a custom script with arbitrary code, which will then be executed on the charging station.", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2024-43657", "datePublished": "2025-01-09T07:56:46.268Z", "dateReserved": "2024-08-14T09:27:41.769Z", "dateUpdated": "2025-01-09T14:44:32.880Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }