Action not permitted
Modal body text goes here.
cve-2022-26507
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://Claroty.com | Not Applicable, Third Party Advisory | |
cve@mitre.org | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | Mitigation, Release Notes, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://Claroty.com | Not Applicable, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | Mitigation, Release Notes, Third Party Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:03:32.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://Claroty.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-14T12:04:26", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://Claroty.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "tags": [ "unsupported-when-assigned" ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-26507", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://Claroty.com", "refsource": "MISC", "url": "https://Claroty.com" }, { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-26507", "datePublished": "2022-04-14T12:04:26", "dateReserved": "2022-03-06T00:00:00", "dateUpdated": "2024-08-03T05:03:32.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-26507\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-04-14T13:15:11.637\",\"lastModified\":\"2024-11-21T06:54:04.920\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cve@mitre.org\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer\"},{\"lang\":\"es\",\"value\":\"** NO SOPORTADO CUANDO SE ASIGN\u00d3 ** Se presenta un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en XML Decompression DecodeTreeBlock en AT\u0026amp;T Labs Xmill versi\u00f3n 0.7. Un archivo de entrada dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Esto no es lo mismo que cualquiera de: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, o CVE-2021-21830. NOTA: Esta vulnerabilidad s\u00f3lo afecta a productos que ya no son soportados por el mantenedor\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"8DCC0C29-32C2-4463-B98F-AB4B56FF5314\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"78F6B1CC-488B-48E8-B96B-77A1894E9E92\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2021\",\"matchCriteriaId\":\"FAB4A9EC-96A2-424D-A858-162E662EBEFB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FFDF36B-30A5-4B35-956C-60DC15CE7EE4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F51A7887-4F1A-428C-9E68-260E7262A678\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58BACC54-6609-4DCE-AEEC-A9C2396635A0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFDF44F3-2514-4CB0-A1A4-87123225B0F1\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E\"}]}]}],\"references\":[{\"url\":\"https://Claroty.com\",\"source\":\"cve@mitre.org\",\"tags\":[\"Not Applicable\",\"Third Party Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mitigation\",\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://Claroty.com\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\",\"Third Party Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Release Notes\",\"Third Party Advisory\"]}]}}" } }
gsd-2022-26507
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-26507", "description": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "id": "GSD-2022-26507" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-26507" ], "details": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "id": "GSD-2022-26507", "modified": "2023-12-13T01:19:39.338073Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-26507", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://Claroty.com", "refsource": "MISC", "url": "https://Claroty.com" }, { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*", "matchCriteriaId": "4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "78F6B1CC-488B-48E8-B96B-77A1894E9E92", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB", "versionEndExcluding": "2021", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E", "vulnerable": false } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" }, { "lang": "es", "value": "** NO SOPORTADO CUANDO SE ASIGN\u00d3 ** Se presenta un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en XML Decompression DecodeTreeBlock en AT\u0026amp;T Labs Xmill versi\u00f3n 0.7. Un archivo de entrada dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Esto no es lo mismo que cualquiera de: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, o CVE-2021-21830. NOTA: Esta vulnerabilidad s\u00f3lo afecta a productos que ya no son soportados por el mantenedor" } ], "id": "CVE-2022-26507", "lastModified": "2024-04-11T01:14:57.903", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-14T13:15:11.637", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable", "Third Party Advisory" ], "url": "https://Claroty.com" }, { "source": "cve@mitre.org", "tags": [ "Mitigation", "Release Notes", "Third Party Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] } } } }
ghsa-92r8-w862-f2pj
Vulnerability from github
** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
{ "affected": [], "aliases": [ "CVE-2022-26507" ], "database_specific": { "cwe_ids": [ "CWE-787" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-04-14T13:15:00Z", "severity": "CRITICAL" }, "details": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "id": "GHSA-92r8-w862-f2pj", "modified": "2022-04-24T00:00:38Z", "published": "2022-04-15T00:00:45Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-26507" }, { "type": "WEB", "url": "https://Claroty.com" }, { "type": "WEB", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
var-202204-0257
Vulnerability from variot
** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0257", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xmill", "scope": "eq", "trust": 1.0, "vendor": "att", "version": "0.7" }, { "model": "ecostruxure process expert", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "2021" }, { "model": "ecostruxure control expert", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "15.1" }, { "model": "ecostruxure control expert", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": "15.1" }, { "model": "remoteconnect", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": null } ], "sources": [ { "db": "NVD", "id": "CVE-2022-26507" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "15.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2021", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-26507" } ] }, "cve": "CVE-2022-26507", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2022-26507", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "HIGH", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-26507", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-26507", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202204-3389", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2022-26507", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-26507" }, { "db": "CNNVD", "id": "CNNVD-202204-3389" }, { "db": "NVD", "id": "CVE-2022-26507" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer", "sources": [ { "db": "NVD", "id": "CVE-2022-26507" }, { "db": "VULMON", "id": "CVE-2022-26507" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SCHNEIDER", "id": "SEVD-2021-222-02", "trust": 1.7 }, { "db": "NVD", "id": "CVE-2022-26507", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202204-3389", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-26507", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-26507" }, { "db": "CNNVD", "id": "CNNVD-202204-3389" }, { "db": "NVD", "id": "CVE-2022-26507" } ] }, "id": "VAR-202204-0257", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.7375 }, "last_update_date": "2022-05-04T09:32:10.215000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "AT\u0026T Labs Xmill Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190458" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3389" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-26507" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://claroty.com" }, { "trust": 1.7, "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-222-02" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26507/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-26507" }, { "db": "CNNVD", "id": "CNNVD-202204-3389" }, { "db": "NVD", "id": "CVE-2022-26507" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-26507" }, { "db": "CNNVD", "id": "CNNVD-202204-3389" }, { "db": "NVD", "id": "CVE-2022-26507" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-14T00:00:00", "db": "VULMON", "id": "CVE-2022-26507" }, { "date": "2022-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-3389" }, { "date": "2022-04-14T13:15:00", "db": "NVD", "id": "CVE-2022-26507" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-23T00:00:00", "db": "VULMON", "id": "CVE-2022-26507" }, { "date": "2022-04-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-3389" }, { "date": "2022-04-23T02:21:00", "db": "NVD", "id": "CVE-2022-26507" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3389" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "AT\u0026T Labs Xmill Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3389" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3389" } ], "trust": 0.6 } }
icsa-22-223-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Carl Hurd" ], "organization": "Cisco Talos", "summary": "reporting these vulnerabilities" }, { "names": [ "Uri Katz" ], "organization": "Claroty Research", "summary": "reporting these vulnerabilities" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "The successful exploitation of these vulnerabilities on the affected products could lead to the execution of malicious files, which could result in code execution with elevated privileges.", "title": "Risk evaluation" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-223-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-223-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-223-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70", "tracking": { "current_release_date": "2022-08-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-223-03", "initial_release_date": "2022-08-11T00:00:00.000000Z", "revision_history": [ { "date": "2022-08-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": " \u003c 15.1 HF001 (including former Unity Pro)", "product": { "name": "EcoStruxure Control Expert: All versions (including former Unity Pro) prior to V15.1 HF001", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "EcoStruxure Control Expert" }, { "branches": [ { "category": "product_version_range", "name": " \u003c 2021 (including former HDCS)", "product": { "name": "EcoStruxure Process Expert: All versions (including former HDCS) prior to V2021", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "EcoStruxure Process Expert" }, { "branches": [ { "category": "product_version_range", "name": "\u003c R2.7.3", "product": { "name": "SCADAPack RemoteConnect for x70: All versions prior to R2.7.3", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SCADAPack RemoteConnect for x70" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-21810", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21810 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21825" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21825", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability exists in the XML Decompression. PlainTextUncompressor::UncompressItem functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XMI file could lead to remote code execution. An attacker could provide a malicious file to trigger this vulnerability.CVE-2021-21825 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21825" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21829", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21829 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21829" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21830", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability exists in the XML Decompression LabelDict::Load functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XML file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21830 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21830" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21811", "cwe": { "id": "CWE-191", "name": "Integer Underflow (Wrap or Wraparound)" }, "notes": [ { "category": "summary", "text": "A memory corruption vulnerability exists in the XML-parsing CreateLabelOrAttrib functionality of AT\u0026T Labs \u0027 Xmill 0.7. The product subtracts one value from another such that the result is less than the minimum allowable integer value, which produces a value not equal to the correct result. CVE-2021-21811 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21811" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21812", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT\u0026T Labs \u0027 Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a static sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger these vulnerabilities.CVE-2021-21812 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21812" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21813", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Within the function HandleFileArg, the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to memcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow.CVE-2021-21813 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21813" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21814", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strlen to determine the ending location of the char* passed in by the user, no checks are done to see if the passed in char* is longer than the staticly sized buffer data is memcpy-d into, but after the memcpy a null byte is written to what is assumed to be the end of the buffer to terminate the char*, but without length checks, this null write occurs at an arbitrary offset from the buffer. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21814 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21814" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21815", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT\u0026T Labs\u0027 Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21815 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21815" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21826", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT\u0026T Labs Xmill 0.7. Within `DecodeTreeBlock,` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer.CVE-2021-21826 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21826" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21827", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT\u0026T Labs Xmill 0.7. Within `DecodeTreeBlock` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21827 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21827" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-21828", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "In the command-line-parsing HandleFileArg functionality of AT\u0026T Labs \u0027 Xmill 0.7, an attacker could trigger the vulnerability by using a specially crafted command-line argument that can lead to code execution.CVE-2021-21828 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21828" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-26507", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file could lead to remote code execution.CVE-2022-26507 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-26507" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "EcoStruxure Control Expert V15.1 HF001 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/" }, { "category": "mitigation", "details": "EcoStruxure Process Expert V2021 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release" }, { "category": "mitigation", "details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://shop.exchange.se.com/en-US/apps/58663" }, { "category": "mitigation", "details": "Securely store the project files and restrict access to trusted users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Use secure communication channels when exchanging files over the network,.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Only open project files received from trusted sources.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running EcoStruxure Process Expert.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Harden the workstation running SCADAPackRemoteConnect for x70", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.