CVE-2021-21829 (GCVE-0-2021-21829)
Vulnerability from cvelistv5
- CWE-122 - Heap-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:23:29.464Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AT\u0026T",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "AT\u0026T Labs Xmill 0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-13T18:17:15",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21829",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AT\u0026T",
"version": {
"version_data": [
{
"version_value": "AT\u0026T Labs Xmill 0.7"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2021-21829",
"datePublished": "2021-08-13T18:17:16",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-08-03T18:23:29.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2021-21829\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2021-08-13T19:15:07.137\",\"lastModified\":\"2024-11-21T05:49:03.670\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en la funcionalidad XML Decompression EnumerationUncompressor::UncompressItem de Xmill versi\u00f3n 0.7 de AT\u0026amp;T Labs. Un archivo XMI especialmente dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Un atacante puede proporcionar un archivo malicioso para desencadenar esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4\"}]}]}],\"references\":[{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
CERTFR-2022-AVI-215
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- EcoStruxure Control Expert versions antérieures à 15.1
- EcoStruxure Process Expert versions antérieures à 2021
- SCADAPack RemoteConnect for x70 toutes versions, se référer aux mesures de contournement proposées par l'éditeur
- Smart-UPS séries SMT micrologiciels versions antérieures à UPS 04.6 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806
- Smart-UPS séries SMC micrologiciels versions antérieures à UPS 04.3 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806
- Aucun correctif n'est disponible pour les séries Smart-UPS SCL, SMX et SRT ainsi que les séries SmartConnect SMTL, SCL, et SMX. Se référer aux mesures de contournement proposées par l'éditeur
- Ritto Wiser Door toutes versions, se référer aux mesures de contournement proposées par l'éditeur
Pour les vulnérabilités identifiées CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise à niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une première étape de contournement. L'éditeur annoncera la publication d'un nouveau micrologiciel afin de corriger ces vulnérabilités.
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eEcoStruxure Control Expert versions ant\u00e9rieures \u00e0 15.1\u003c/li\u003e \u003cli\u003eEcoStruxure Process Expert versions ant\u00e9rieures \u00e0 2021\u003c/li\u003e \u003cli\u003eSCADAPack RemoteConnect for x70 toutes versions, se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMT micrologiciels versions ant\u00e9rieures \u00e0 UPS 04.6 permettant une correction partielle de la vuln\u00e9rabilit\u00e9 CVE-2022-0715 et une correction des vuln\u00e9rabilit\u00e9s CVE-2022-22805 et CVE-2022-22806\u003c/li\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMC micrologiciels versions ant\u00e9rieures \u00e0 UPS 04.3 permettant une correction partielle de la vuln\u00e9rabilit\u00e9 CVE-2022-0715 et une correction des vuln\u00e9rabilit\u00e9s CVE-2022-22805 et CVE-2022-22806\u003c/li\u003e \u003cli\u003eAucun correctif n\u0027est disponible pour les s\u00e9ries Smart-UPS SCL, SMX et SRT ainsi que les s\u00e9ries SmartConnect SMTL, SCL, et SMX. Se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003cli\u003eRitto Wiser Door toutes versions, se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003c/ul\u003e \u003cp\u003ePour les vuln\u00e9rabilit\u00e9s identifi\u00e9es CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise \u00e0 niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une premi\u00e8re \u00e9tape de contournement. L\u0027\u00e9diteur annoncera la publication d\u0027un nouveau micrologiciel afin de corriger ces vuln\u00e9rabilit\u00e9s.\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2021-21814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21814"
},
{
"name": "CVE-2021-34527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34527"
},
{
"name": "CVE-2021-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21830"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22781",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22781"
},
{
"name": "CVE-2021-22780",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22780"
},
{
"name": "CVE-2021-21828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21828"
},
{
"name": "CVE-2021-21810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21810"
},
{
"name": "CVE-2021-21813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21813"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2021-21825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21825"
},
{
"name": "CVE-2021-21829",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21829"
},
{
"name": "CVE-2021-1675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-1675"
},
{
"name": "CVE-2021-22782",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22782"
},
{
"name": "CVE-2021-22778",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22778"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2021-21826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21826"
},
{
"name": "CVE-2021-21812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21812"
},
{
"name": "CVE-2021-21827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21827"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2021-21815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21815"
},
{
"name": "CVE-2021-22783",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22783"
},
{
"name": "CVE-2021-21811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21811"
},
{
"name": "CVE-2020-12525",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12525"
}
],
"initial_release_date": "2022-03-08T00:00:00",
"last_revision_date": "2022-03-08T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-215",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-03-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-222-02 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-03 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider 2021-194-01 du 13 juillet 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
}
]
}
CERTFR-2022-AVI-646
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | EcoStruxure Control Expert (incluant le produit Unity Pro) versions antérieures à 15.1 HF001 | ||
| Schneider Electric | N/A | X80 advanced RTU Communication Module (BMENOR2200H) versions antérieures à 2.0.1 | ||
| Schneider Electric | N/A | OPC UA Modicon Communication Module (BMENUA0100) versions 1.10 et antérieures : L'éditeur ne propose pas de correctif, se référer aux mesures de contournement | ||
| Schneider Electric | N/A | EcoStruxure Process Expert (incluant le produit HDCS) versions antérieures à 2021 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Control Expert (incluant le produit Unity Pro) versions ant\u00e9rieures \u00e0 15.1 HF001",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "X80 advanced RTU Communication Module (BMENOR2200H) versions ant\u00e9rieures \u00e0 2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "OPC UA Modicon Communication Module (BMENUA0100) versions 1.10 et ant\u00e9rieures : L\u0027\u00e9diteur ne propose pas de correctif, se r\u00e9f\u00e9rer aux mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert (incluant le produit HDCS) versions ant\u00e9rieures \u00e0 2021",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-21814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21814"
},
{
"name": "CVE-2022-34760",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34760"
},
{
"name": "CVE-2021-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21830"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2022-34762",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34762"
},
{
"name": "CVE-2021-21828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21828"
},
{
"name": "CVE-2021-21810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21810"
},
{
"name": "CVE-2021-21813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21813"
},
{
"name": "CVE-2022-34761",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34761"
},
{
"name": "CVE-2021-21825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21825"
},
{
"name": "CVE-2022-34759",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34759"
},
{
"name": "CVE-2021-21829",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21829"
},
{
"name": "CVE-2022-34764",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34764"
},
{
"name": "CVE-2022-34763",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34763"
},
{
"name": "CVE-2021-21826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21826"
},
{
"name": "CVE-2021-21812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21812"
},
{
"name": "CVE-2021-21827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21827"
},
{
"name": "CVE-2022-26507",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26507"
},
{
"name": "CVE-2022-34765",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34765"
},
{
"name": "CVE-2021-21815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21815"
},
{
"name": "CVE-2021-21811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21811"
}
],
"initial_release_date": "2022-07-15T00:00:00",
"last_revision_date": "2022-08-19T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric\u00a0SEVD-2022-193-01 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules_Security_Notification_V3.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric\u00a0SEVD-2021-257-01 mis \u00e0 jour le 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-257-01_EcoStruxure_Control_Expert_EcoStruxure_Process_Expert_SCADAPack_Security_Notification_V3.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric\u00a0SEVD-2021-222-02 mis \u00e0 jour le 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-222-02_AT%26T_Labs-XMILX_DEMILL_Eco_Struxure_Control_ExpertEco_Struxure_Process_Expert_SCADA_Pack_RemoteConnect_x70_Security_Notification_V4.0.pdf"
}
],
"reference": "CERTFR-2022-AVI-646",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-07-15T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-01 du 12 juillet 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-02 mis \u00e0 jour le 12 juillet 2022",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-01 du 12 juillet 2022",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-257-01 mis \u00e0 jour le 12 juillet 2022",
"url": null
}
]
}
CERTFR-2021-AVI-622
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer un problème de sécurité non spécifié par l'éditeur, une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Modicon et PLC Simulator (suivre la procédure de contournement décrite dans le bulletin SEVD-2021-222-04) | ||
| Schneider Electric | N/A | Pro-face GP-Pro EX versions antérieures à V4.09.300 | ||
| Schneider Electric | N/A | Vijeo Designer versions antérieures à V6.2 SP11 | ||
| Schneider Electric | N/A | EcoStruxure Process Expert toutes versions (inclus HDCS) et SCADAPack RemoteConnect pour x70 (suivre la procédure de contournement décrite dans le bulletin SEVD-2021-222-02) | ||
| Schneider Electric | N/A | AccuSine PCS+ / PFV+ versions antérieures à V1.6.7 | ||
| Schneider Electric | N/A | Vijeo Designer Basic versions antérieures à V1.2 | ||
| Schneider Electric | N/A | EcoStruxure Control Expert versions antérieures à V15.0 SP1 (suivre la procédure de remédiation décrite dans le bulletin SEVD-2021-222-02) | ||
| Schneider Electric | N/A | AccuSine PCSn versions antérieures à V2.2.4 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert versions antérieures à V2.0 | ||
| Schneider Electric | N/A | SHAIIS-MT-111, SHASU-MT-107, SHFK-MT et SHFK-MT-104 sans le dernier correctif pour Windows | ||
| Schneider Electric | N/A | Programmable Automation Controller (PacDrive) M versions antérieures à 3 (suivre la procédure de contournement décrite dans le bulletin SEVD-2021-222-06) |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon et PLC Simulator (suivre la proc\u00e9dure de contournement d\u00e9crite dans le bulletin SEVD-2021-222-04)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP-Pro EX versions ant\u00e9rieures \u00e0 V4.09.300",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer versions ant\u00e9rieures \u00e0 V6.2 SP11",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert toutes versions (inclus HDCS) et SCADAPack RemoteConnect pour x70 (suivre la proc\u00e9dure de contournement d\u00e9crite dans le bulletin SEVD-2021-222-02)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "AccuSine PCS+ / PFV+ versions ant\u00e9rieures \u00e0 V1.6.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer Basic versions ant\u00e9rieures \u00e0 V1.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Control Expert versions ant\u00e9rieures \u00e0 V15.0 SP1 (suivre la proc\u00e9dure de rem\u00e9diation d\u00e9crite dans le bulletin SEVD-2021-222-02)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "AccuSine PCSn versions ant\u00e9rieures \u00e0 V2.2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SHAIIS-MT-111, SHASU-MT-107, SHFK-MT et SHFK-MT-104 sans le dernier correctif pour Windows",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Programmable Automation Controller (PacDrive) M versions ant\u00e9rieures \u00e0 3 (suivre la proc\u00e9dure de contournement d\u00e9crite dans le bulletin SEVD-2021-222-06)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-21814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21814"
},
{
"name": "CVE-2021-34527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34527"
},
{
"name": "CVE-2021-22791",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22791"
},
{
"name": "CVE-2021-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21830"
},
{
"name": "CVE-2021-21828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21828"
},
{
"name": "CVE-2021-21810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21810"
},
{
"name": "CVE-2021-21813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21813"
},
{
"name": "CVE-2021-22790",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22790"
},
{
"name": "CVE-2021-21825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21825"
},
{
"name": "CVE-2021-21829",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21829"
},
{
"name": "CVE-2021-31166",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31166"
},
{
"name": "CVE-2021-1675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-1675"
},
{
"name": "CVE-2021-21826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21826"
},
{
"name": "CVE-2021-21812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21812"
},
{
"name": "CVE-2021-30186",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30186"
},
{
"name": "CVE-2021-21827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21827"
},
{
"name": "CVE-2021-30188",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30188"
},
{
"name": "CVE-2021-22789",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22789"
},
{
"name": "CVE-2021-21815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21815"
},
{
"name": "CVE-2021-22792",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22792"
},
{
"name": "CVE-2021-22793",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22793"
},
{
"name": "CVE-2021-22704",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22704"
},
{
"name": "CVE-2021-30195",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30195"
},
{
"name": "CVE-2021-21811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21811"
},
{
"name": "CVE-2021-22775",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22775"
}
],
"initial_release_date": "2021-08-12T00:00:00",
"last_revision_date": "2021-08-12T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-622",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-08-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer un probl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur, une\nex\u00e9cution de code arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-08 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-08"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-07 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-03 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-01 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-05 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-04 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-02 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-06 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-06"
}
]
}
CERTFR-2022-AVI-628
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | SpaceLogic C-Bus Home Controller (5200WHC2), C-Bus Wiser Homer Controller MK2 versions antérieures à 4.14.0 (PICED_V4.14.0 Programming Interface for C-Bus Embedded Devices version V4.14.0) | ||
| Schneider Electric | N/A | X80 advanced RTU Communication Module (BMENOR2200H) versions antérieures à 2.01 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22074 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect for x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | Micrologiciels Easergy P5 versions antérieures à 01.401.102 | ||
| Schneider Electric | N/A | Acti9 PowerTag Link C (A9XELC10-B) versions antérieures à 2.14.0 | ||
| Schneider Electric | N/A | OPC UA Modicon Communication Module (BMENUA0100) versions 1.10 et antérieures | ||
| Schneider Electric | N/A | Acti9 PowerTag Link C (A9XELC10-A) versions antérieures à 2.14.0 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert versions antérieures à 2.0.3 | ||
| Schneider Electric | N/A | Micrologiciels Smart-UPS SCL, SRT, SRC, & XU Series versions antérieures à 15.0 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SpaceLogic C-Bus Home Controller (5200WHC2), C-Bus Wiser Homer Controller MK2 versions ant\u00e9rieures \u00e0 4.14.0 (PICED_V4.14.0 Programming Interface for C-Bus Embedded Devices version V4.14.0)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "X80 advanced RTU Communication Module (BMENOR2200H) versions ant\u00e9rieures \u00e0 2.01",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22074",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect for x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Micrologiciels Easergy P5 versions ant\u00e9rieures \u00e0 01.401.102",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Acti9 PowerTag Link C (A9XELC10-B) versions ant\u00e9rieures \u00e0 2.14.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "OPC UA Modicon Communication Module (BMENUA0100) versions 1.10 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Acti9 PowerTag Link C (A9XELC10-A) versions ant\u00e9rieures \u00e0 2.14.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert versions ant\u00e9rieures \u00e0 2.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Micrologiciels Smart-UPS SCL, SRT, SRC, \u0026 XU Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-2329",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2329"
},
{
"name": "CVE-2021-21814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21814"
},
{
"name": "CVE-2021-21869",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21869"
},
{
"name": "CVE-2022-34760",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34760"
},
{
"name": "CVE-2021-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21830"
},
{
"name": "CVE-2021-21866",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21866"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2022-34753",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34753"
},
{
"name": "CVE-2022-34762",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34762"
},
{
"name": "CVE-2022-34758",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34758"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22781",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22781"
},
{
"name": "CVE-2021-22780",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22780"
},
{
"name": "CVE-2021-21828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21828"
},
{
"name": "CVE-2021-21810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21810"
},
{
"name": "CVE-2021-21813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21813"
},
{
"name": "CVE-2022-34761",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34761"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2021-21825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21825"
},
{
"name": "CVE-2022-34759",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34759"
},
{
"name": "CVE-2022-34757",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34757"
},
{
"name": "CVE-2021-21829",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21829"
},
{
"name": "CVE-2021-21863",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21863"
},
{
"name": "CVE-2022-34754",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34754"
},
{
"name": "CVE-2021-22782",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22782"
},
{
"name": "CVE-2021-22778",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22778"
},
{
"name": "CVE-2022-34764",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34764"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2021-21865",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21865"
},
{
"name": "CVE-2022-34763",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34763"
},
{
"name": "CVE-2021-21867",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21867"
},
{
"name": "CVE-2022-34756",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34756"
},
{
"name": "CVE-2021-21826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21826"
},
{
"name": "CVE-2021-21812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21812"
},
{
"name": "CVE-2021-21827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21827"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-26507",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26507"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2022-34765",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34765"
},
{
"name": "CVE-2021-21815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21815"
},
{
"name": "CVE-2021-21811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21811"
},
{
"name": "CVE-2020-12525",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12525"
},
{
"name": "CVE-2021-29240",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"name": "CVE-2021-21864",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21864"
},
{
"name": "CVE-2022-24324",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24324"
},
{
"name": "CVE-2021-21868",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21868"
},
{
"name": "CVE-2021-33485",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33485"
}
],
"initial_release_date": "2022-07-12T00:00:00",
"last_revision_date": "2022-08-22T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-628",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-07-12T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour des liens",
"revision_date": "2022-08-22T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour des liens",
"revision_date": "2022-08-22T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-194-01 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-194-01_EcoStruxure_Control_Expert_Process_Expert_SCADAPack_RemoteConnect_Modicon_M580_M340_V4.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-02 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-01 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules_Security_Notification_V3.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-03 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-011-06 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-011-06_CODESYSV3_Runtime_Development_System_and_Gateway_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-257-01 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-257-01_EcoStruxure_Control_Expert_EcoStruxure_Process_Expert_SCADAPack_Security_Notification_V3.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-067-02 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-102-01 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-102-01_IGSS_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-04 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-04_Easergy_P5_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-02 du 12 juillet 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-222-02_AT%26T_Labs-XMILX_DEMILL_Eco_Struxure_Control_ExpertEco_Struxure_Process_Expert_SCADA_Pack_RemoteConnect_x70_Security_Notification_V4.0.pdf"
}
]
}
ICSA-22-223-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Carl Hurd"
],
"organization": "Cisco Talos",
"summary": "reporting these vulnerabilities"
},
{
"names": [
"Uri Katz"
],
"organization": "Claroty Research",
"summary": "reporting these vulnerabilities"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "The successful exploitation of these vulnerabilities on the affected products could lead to the execution of malicious files, which could result in code execution with elevated privileges.",
"title": "Risk evaluation"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-22-223-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-223-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-223-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70",
"tracking": {
"current_release_date": "2022-08-11T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-223-03",
"initial_release_date": "2022-08-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-08-11T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": " \u003c 15.1 HF001 (including former Unity Pro)",
"product": {
"name": "EcoStruxure Control Expert: All versions (including former Unity Pro) prior to V15.1 HF001",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EcoStruxure Control Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": " \u003c 2021 (including former HDCS)",
"product": {
"name": "EcoStruxure Process Expert: All versions (including former HDCS) prior to V2021",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "EcoStruxure Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c R2.7.3",
"product": {
"name": "SCADAPack RemoteConnect for x70: All versions prior to R2.7.3",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SCADAPack RemoteConnect for x70"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-21810",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21810 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21825"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21825",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression. PlainTextUncompressor::UncompressItem functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XMI file could lead to remote code execution. An attacker could provide a malicious file to trigger this vulnerability.CVE-2021-21825 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21825"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21829",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21829 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21829"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21830",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression LabelDict::Load functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XML file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21830 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21830"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21811",
"cwe": {
"id": "CWE-191",
"name": "Integer Underflow (Wrap or Wraparound)"
},
"notes": [
{
"category": "summary",
"text": "A memory corruption vulnerability exists in the XML-parsing CreateLabelOrAttrib functionality of AT\u0026T Labs \u0027 Xmill 0.7. The product subtracts one value from another such that the result is less than the minimum allowable integer value, which produces a value not equal to the correct result. CVE-2021-21811 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21811"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21812",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT\u0026T Labs \u0027 Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a static sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger these vulnerabilities.CVE-2021-21812 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21812"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21813",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Within the function HandleFileArg, the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to memcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow.CVE-2021-21813 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21813"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21814",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strlen to determine the ending location of the char* passed in by the user, no checks are done to see if the passed in char* is longer than the staticly sized buffer data is memcpy-d into, but after the memcpy a null byte is written to what is assumed to be the end of the buffer to terminate the char*, but without length checks, this null write occurs at an arbitrary offset from the buffer. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21814 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21814"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21815",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT\u0026T Labs\u0027 Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21815 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21815"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21826",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT\u0026T Labs Xmill 0.7. Within `DecodeTreeBlock,` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer.CVE-2021-21826 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21826"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21827",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT\u0026T Labs Xmill 0.7. Within `DecodeTreeBlock` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21827 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21827"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21828",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "In the command-line-parsing HandleFileArg functionality of AT\u0026T Labs \u0027 Xmill 0.7, an attacker could trigger the vulnerability by using a specially crafted command-line argument that can lead to code execution.CVE-2021-21828 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21828"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2022-26507",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file could lead to remote code execution.CVE-2022-26507 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-26507"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
icsa-22-223-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Carl Hurd"
],
"organization": "Cisco Talos",
"summary": "reporting these vulnerabilities"
},
{
"names": [
"Uri Katz"
],
"organization": "Claroty Research",
"summary": "reporting these vulnerabilities"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "The successful exploitation of these vulnerabilities on the affected products could lead to the execution of malicious files, which could result in code execution with elevated privileges.",
"title": "Risk evaluation"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-22-223-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-223-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-223-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70",
"tracking": {
"current_release_date": "2022-08-11T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-223-03",
"initial_release_date": "2022-08-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-08-11T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": " \u003c 15.1 HF001 (including former Unity Pro)",
"product": {
"name": "EcoStruxure Control Expert: All versions (including former Unity Pro) prior to V15.1 HF001",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EcoStruxure Control Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": " \u003c 2021 (including former HDCS)",
"product": {
"name": "EcoStruxure Process Expert: All versions (including former HDCS) prior to V2021",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "EcoStruxure Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c R2.7.3",
"product": {
"name": "SCADAPack RemoteConnect for x70: All versions prior to R2.7.3",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SCADAPack RemoteConnect for x70"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-21810",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21810 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21825"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21825",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression. PlainTextUncompressor::UncompressItem functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XMI file could lead to remote code execution. An attacker could provide a malicious file to trigger this vulnerability.CVE-2021-21825 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21825"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21829",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21829 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21829"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21830",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression LabelDict::Load functionality of AT\u0026T Labs \u0027 Xmill 0.7. A specially crafted XML file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21830 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21830"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21811",
"cwe": {
"id": "CWE-191",
"name": "Integer Underflow (Wrap or Wraparound)"
},
"notes": [
{
"category": "summary",
"text": "A memory corruption vulnerability exists in the XML-parsing CreateLabelOrAttrib functionality of AT\u0026T Labs \u0027 Xmill 0.7. The product subtracts one value from another such that the result is less than the minimum allowable integer value, which produces a value not equal to the correct result. CVE-2021-21811 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-21811"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21812",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT\u0026T Labs \u0027 Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a static sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger these vulnerabilities.CVE-2021-21812 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21812"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21813",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Within the function HandleFileArg, the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to memcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow.CVE-2021-21813 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21813"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21814",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strlen to determine the ending location of the char* passed in by the user, no checks are done to see if the passed in char* is longer than the staticly sized buffer data is memcpy-d into, but after the memcpy a null byte is written to what is assumed to be the end of the buffer to terminate the char*, but without length checks, this null write occurs at an arbitrary offset from the buffer. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21814 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21814"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21815",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT\u0026T Labs\u0027 Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21815 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21815"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21826",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT\u0026T Labs Xmill 0.7. Within `DecodeTreeBlock,` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer.CVE-2021-21826 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21826"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21827",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT\u0026T Labs Xmill 0.7. Within `DecodeTreeBlock` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21827 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21827"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2021-21828",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "In the command-line-parsing HandleFileArg functionality of AT\u0026T Labs \u0027 Xmill 0.7, an attacker could trigger the vulnerability by using a specially crafted command-line argument that can lead to code execution.CVE-2021-21828 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21828"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2022-26507",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file could lead to remote code execution.CVE-2022-26507 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-26507"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "AT\u0026T Labs have stated this software is longer supported and recommends vendors to move away from using it.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "EcoStruxure Control Expert V15.1 HF001 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/ControlExpert_V151_HF001/"
},
{
"category": "mitigation",
"details": "EcoStruxure Process Expert V2021 or later.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "mitigation",
"details": "SCADAPack RemoteConnect for R2.7.3 or later (Users no longer need to update the RemoteConnect application when a Control Expert update is present.)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://shop.exchange.se.com/en-US/apps/58663"
},
{
"category": "mitigation",
"details": "Securely store the project files and restrict access to trusted users.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Use secure communication channels when exchanging files over the network,.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Only open project files received from trusted sources.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Compute a hash of the project files and regularly check the consistency of this hash to verify integrity before usage.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Control Expert or Unity Pro.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Users using Unity Pro should consider migrating to EcoStruxure Control Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running EcoStruxure Process Expert.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Harden the workstation running SCADAPackRemoteConnect for x70",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "See the Schneider Electric Security Notification, number SEVD-2021-222-02 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-222-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
fkie_cve-2021-21829
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292 | Exploit, Third Party Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en la funcionalidad XML Decompression EnumerationUncompressor::UncompressItem de Xmill versi\u00f3n 0.7 de AT\u0026amp;T Labs. Un archivo XMI especialmente dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Un atacante puede proporcionar un archivo malicioso para desencadenar esta vulnerabilidad."
}
],
"id": "CVE-2021-21829",
"lastModified": "2024-11-21T05:49:03.670",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-13T19:15:07.137",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
ghsa-whj6-8xvc-hmjm
Vulnerability from github
A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT&T Labs’ Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.
{
"affected": [],
"aliases": [
"CVE-2021-21829"
],
"database_specific": {
"cwe_ids": [
"CWE-787",
"CWE-91"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-08-13T19:15:00Z",
"severity": "CRITICAL"
},
"details": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.",
"id": "GHSA-whj6-8xvc-hmjm",
"modified": "2022-06-01T00:00:24Z",
"published": "2022-05-24T22:29:03Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21829"
},
{
"type": "WEB",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
gsd-2021-21829
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2021-21829",
"description": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.",
"id": "GSD-2021-21829"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-21829"
],
"details": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.",
"id": "GSD-2021-21829",
"modified": "2023-12-13T01:23:10.567435Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21829",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AT\u0026T",
"version": {
"version_data": [
{
"version_value": "AT\u0026T Labs Xmill 0.7"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21829"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT\u0026T Labs\u2019 Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292",
"refsource": "MISC",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1292"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-10-25T16:04Z",
"publishedDate": "2021-08-13T19:15Z"
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.