Common Weakness Enumeration
CWE-924
AllowedImproper Enforcement of Message Integrity During Transmission in a Communication Channel
Abstraction: Base · Status: Incomplete
The product establishes a communication channel with an endpoint and receives a message from that endpoint, but it does not sufficiently ensure that the message was not modified during transmission.
52 vulnerabilities reference this CWE, most recent first.
CVE-2026-54891 (GCVE-0-2026-54891)
Vulnerability from cvelistv5 – Published: 2026-07-02 16:06 – Updated: 2026-08-03 14:51
VLAI
EPSS
VEX
Title
Plaintext APPLICATION_DATA injected during TLS handshake delivered to client application post-handshake in ssl
Summary
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Erlang/OTP ssl (tls_gen_connection module) allows a network-positioned attacker to inject unauthenticated plaintext that the TLS client application later treats as authenticated server data.
The function tls_gen_connection:handle_protocol_record/3 rejects APPLICATION_DATA records that arrive in pre-handshake states when the TLS endpoint acts as a server, but does not apply the same check when the endpoint acts as a client. A network-positioned attacker can send plaintext APPLICATION_DATA records to the client during the handshake. The records are buffered and, once the handshake completes successfully, delivered to the application as if they were authenticated post-handshake data. The attacker cannot observe the client's response or steer the connection, so the impact is limited to blind injection of unauthenticated bytes. The injection window is wider for TLS versions prior to TLS 1.3 than for TLS 1.3.
This vulnerability is associated with program file lib/ssl/src/tls_gen_connection.erl.
TLS 1.3 is affected starting with OTP 22.0, when TLS 1.3 support was added.
This issue affects OTP from OTP R13B03 before OTP 27.3.4.14, from OTP 28.0 before OTP 28.5.0.3, and from OTP 29.0 before OTP 29.0.3, corresponding to ssl from 3.10.7 before 11.2.12.10, from 11.3 before 11.6.0.3, and from 11.7 before 11.7.3. Whether OTP before OTP R13B03, corresponding to ssl before 3.10.7, is affected is unknown.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://github.com/erlang/otp/security/advisories… | vendor-advisoryrelated |
| https://cna.erlef.org/cves/CVE-2026-54891.html | related |
| https://osv.dev/vulnerability/EEF-CVE-2026-54891 | related |
| https://www.erlang.org/doc/system/versions.html#o… | x_version-scheme |
| https://github.com/erlang/otp/commit/07d2d0e93f6a… | patch |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Erlang | OTP |
Unknown:
0 , < R13B03
(otp)
Affected: R13B03 , < 27.3.4.14 (otp) Affected: 28.0 , < 28.5.0.3 (otp) Affected: 29.0 , < 29.0.3 (otp) cpe:2.3:a:erlang:erlang\/otp:*:*:*:*:*:*:*:* |
|
| Erlang | OTP |
Unknown:
0 , < 3.10.7
(otp)
Affected: 3.10.7 , < 11.2.12.10 (otp) Affected: 11.3 , < 11.6.0.3 (otp) Affected: 11.7 , < 11.7.3 (otp) cpe:2.3:a:erlang:erlang\/otp:*:*:*:*:*:*:*:* |
|
| Erlang | OTP |
Affected:
84adefa331c4159d432d22840663c38f155cd4c1 , < 07d2d0e93f6aaf7652a81e8df075fc1728da5e96
(git)
cpe:2.3:a:erlang:erlang\/otp:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54891",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-02T17:24:44.468465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-02T17:24:50.025Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:erlang:erlang\\/otp:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"modules": [
"tls_gen_connection"
],
"packageName": "otp",
"packageURL": "pkg:sid/erlang.org/otp",
"product": "OTP",
"programFiles": [
"lib/ssl/src/tls_gen_connection.erl"
],
"programRoutines": [
{
"name": "tls_gen_connection:handle_protocol_record/3"
}
],
"vendor": "Erlang",
"versions": [
{
"lessThan": "R13B03",
"status": "unknown",
"version": "0",
"versionType": "otp"
},
{
"lessThan": "27.3.4.14",
"status": "affected",
"version": "R13B03",
"versionType": "otp"
},
{
"lessThan": "28.5.0.3",
"status": "affected",
"version": "28.0",
"versionType": "otp"
},
{
"lessThan": "29.0.3",
"status": "affected",
"version": "29.0",
"versionType": "otp"
}
]
},
{
"cpes": [
"cpe:2.3:a:erlang:erlang\\/otp:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"modules": [
"tls_gen_connection"
],
"packageName": "ssl",
"packageURL": "pkg:otp/ssl?repository_url=https:%2F%2Fgithub.com%2Ferlang%2Fotp\u0026vcs_url=git%20https:%2F%2Fgithub.com%2Ferlang%2Fotp.git",
"product": "OTP",
"programFiles": [
"src/tls_gen_connection.erl"
],
"programRoutines": [
{
"name": "tls_gen_connection:handle_protocol_record/3"
}
],
"repo": "https://github.com/erlang/otp",
"vendor": "Erlang",
"versions": [
{
"lessThan": "3.10.7",
"status": "unknown",
"version": "0",
"versionType": "otp"
},
{
"lessThan": "11.2.12.10",
"status": "affected",
"version": "3.10.7",
"versionType": "otp"
},
{
"lessThan": "11.6.0.3",
"status": "affected",
"version": "11.3",
"versionType": "otp"
},
{
"lessThan": "11.7.3",
"status": "affected",
"version": "11.7",
"versionType": "otp"
}
]
},
{
"collectionURL": "https://github.com",
"cpes": [
"cpe:2.3:a:erlang:erlang\\/otp:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"modules": [
"tls_gen_connection"
],
"packageName": "erlang/otp",
"packageURL": "pkg:github/erlang/otp",
"product": "OTP",
"programFiles": [
"lib/ssl/src/tls_gen_connection.erl"
],
"programRoutines": [
{
"name": "tls_gen_connection:handle_protocol_record/3"
}
],
"repo": "https://github.com/erlang/otp",
"vendor": "Erlang",
"versions": [
{
"lessThan": "07d2d0e93f6aaf7652a81e8df075fc1728da5e96",
"status": "affected",
"version": "84adefa331c4159d432d22840663c38f155cd4c1",
"versionType": "git"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:erlang:erlang\\/otp:*:*:*:*:*:*:*:*",
"versionEndExcluding": "27.3.4.14",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:erlang:erlang\\/otp:*:*:*:*:*:*:*:*",
"versionEndExcluding": "28.5.0.3",
"versionStartIncluding": "28.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:erlang:erlang\\/otp:*:*:*:*:*:*:*:*",
"versionEndExcluding": "29.0.3",
"versionStartIncluding": "29.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Lukas Backstr\u00f6m"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ingela Anderton Andin"
},
{
"lang": "en",
"type": "remediation reviewer",
"value": "Dan Gudmundsson"
},
{
"lang": "en",
"type": "remediation reviewer",
"value": "Jakub Witczak"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eImproper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Erlang/OTP ssl (tls_gen_connection module) allows a network-positioned attacker to inject unauthenticated plaintext that the TLS client application later treats as authenticated server data.\u003c/p\u003e\n\u003cp\u003eThe function \u003ccode\u003etls_gen_connection:handle_protocol_record/3\u003c/code\u003e rejects \u003ccode\u003eAPPLICATION_DATA\u003c/code\u003e records that arrive in pre-handshake states when the TLS endpoint acts as a server, but does not apply the same check when the endpoint acts as a client. A network-positioned attacker can send plaintext \u003ccode\u003eAPPLICATION_DATA\u003c/code\u003e records to the client during the handshake. The records are buffered and, once the handshake completes successfully, delivered to the application as if they were authenticated post-handshake data. The attacker cannot observe the client\u0027s response or steer the connection, so the impact is limited to blind injection of unauthenticated bytes. The injection window is wider for TLS versions prior to TLS 1.3 than for TLS 1.3.\u003c/p\u003e\n\u003cp\u003eThis vulnerability is associated with program file \u003ccode\u003elib/ssl/src/tls_gen_connection.erl\u003c/code\u003e.\u003c/p\u003e\n\u003cp\u003eTLS 1.3 is affected starting with OTP\u0026nbsp;22.0, when TLS 1.3 support was added.\u003c/p\u003e\n\u003cp\u003eThis issue affects OTP from OTP\u0026nbsp;R13B03 before OTP\u0026nbsp;27.3.4.14, from OTP\u0026nbsp;28.0 before OTP\u0026nbsp;28.5.0.3, and from OTP\u0026nbsp;29.0 before OTP\u0026nbsp;29.0.3, corresponding to ssl from 3.10.7 before 11.2.12.10, from 11.3 before 11.6.0.3, and from 11.7 before 11.7.3. Whether OTP before OTP\u0026nbsp;R13B03, corresponding to ssl before 3.10.7, is affected is unknown.\u003c/p\u003e"
},
{
"base64": false,
"type": "text/markdown",
"value": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Erlang/OTP ssl (tls_gen_connection module) allows a network-positioned attacker to inject unauthenticated plaintext that the TLS client application later treats as authenticated server data.\n\nThe function `tls_gen_connection:handle_protocol_record/3` rejects `APPLICATION_DATA` records that arrive in pre-handshake states when the TLS endpoint acts as a server, but does not apply the same check when the endpoint acts as a client. A network-positioned attacker can send plaintext `APPLICATION_DATA` records to the client during the handshake. The records are buffered and, once the handshake completes successfully, delivered to the application as if they were authenticated post-handshake data. The attacker cannot observe the client\u0027s response or steer the connection, so the impact is limited to blind injection of unauthenticated bytes. The injection window is wider for TLS versions prior to TLS 1.3 than for TLS 1.3.\n\nThis vulnerability is associated with program file `lib/ssl/src/tls_gen_connection.erl`.\n\nTLS 1.3 is affected starting with OTP\u0026nbsp;22.0, when TLS 1.3 support was added.\n\nThis issue affects OTP from OTP\u00a0R13B03 before OTP\u00a027.3.4.14, from OTP\u00a028.0 before OTP\u00a028.5.0.3, and from OTP\u00a029.0 before OTP\u00a029.0.3, corresponding to ssl from 3.10.7 before 11.2.12.10, from 11.3 before 11.6.0.3, and from 11.7 before 11.7.3. Whether OTP before OTP\u00a0R13B03, corresponding to ssl before 3.10.7, is affected is unknown."
}
],
"value": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Erlang/OTP ssl (tls_gen_connection module) allows a network-positioned attacker to inject unauthenticated plaintext that the TLS client application later treats as authenticated server data.\n\nThe function tls_gen_connection:handle_protocol_record/3 rejects APPLICATION_DATA records that arrive in pre-handshake states when the TLS endpoint acts as a server, but does not apply the same check when the endpoint acts as a client. A network-positioned attacker can send plaintext APPLICATION_DATA records to the client during the handshake. The records are buffered and, once the handshake completes successfully, delivered to the application as if they were authenticated post-handshake data. The attacker cannot observe the client\u0027s response or steer the connection, so the impact is limited to blind injection of unauthenticated bytes. The injection window is wider for TLS versions prior to TLS 1.3 than for TLS 1.3.\n\nThis vulnerability is associated with program file lib/ssl/src/tls_gen_connection.erl.\n\nTLS 1.3 is affected starting with OTP\u00a022.0, when TLS 1.3 support was added.\n\nThis issue affects OTP from OTP\u00a0R13B03 before OTP\u00a027.3.4.14, from OTP\u00a028.0 before OTP\u00a028.5.0.3, and from OTP\u00a029.0 before OTP\u00a029.0.3, corresponding to ssl from 3.10.7 before 11.2.12.10, from 11.3 before 11.6.0.3, and from 11.7 before 11.7.3. Whether OTP before OTP\u00a0R13B03, corresponding to ssl before 3.10.7, is affected is unknown."
}
],
"impacts": [
{
"capecId": "CAPEC-94",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-94 Adversary in the Middle (AiTM)"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-03T14:51:40.832Z",
"orgId": "6b3ad84c-e1a6-4bf7-a703-f496b71e49db",
"shortName": "EEF"
},
"references": [
{
"tags": [
"vendor-advisory",
"related"
],
"url": "https://github.com/erlang/otp/security/advisories/GHSA-gf6r-99xw-6qg6"
},
{
"tags": [
"related"
],
"url": "https://cna.erlef.org/cves/CVE-2026-54891.html"
},
{
"tags": [
"related"
],
"url": "https://osv.dev/vulnerability/EEF-CVE-2026-54891"
},
{
"tags": [
"x_version-scheme"
],
"url": "https://www.erlang.org/doc/system/versions.html#order-of-versions"
},
{
"tags": [
"patch"
],
"url": "https://github.com/erlang/otp/commit/07d2d0e93f6aaf7652a81e8df075fc1728da5e96"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Plaintext APPLICATION_DATA injected during TLS handshake delivered to client application post-handshake in ssl"
}
},
"cveMetadata": {
"assignerOrgId": "6b3ad84c-e1a6-4bf7-a703-f496b71e49db",
"assignerShortName": "EEF",
"cveId": "CVE-2026-54891",
"datePublished": "2026-07-02T16:06:30.982Z",
"dateReserved": "2026-06-16T10:47:13.915Z",
"dateUpdated": "2026-08-03T14:51:40.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-13584 (GCVE-0-2026-13584)
Vulnerability from cvelistv5 – Published: 2026-07-30 06:44 – Updated: 2026-08-04 03:56
VLAI
EPSS
VEX
Title
Information tampering and Denial-of-service (DoS) vulnerability in CC-Link IE TSN communication protocol
Summary
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.mitsubishielectric.com/psirt/vulnerab… | vendor-advisory |
| https://jvn.jp/vu/JVNVU98879231/ | government-resource |
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
115 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-13584",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-30T12:54:42.601094Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-30T12:54:50.557Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR300-16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR300-32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR300-64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR500-128",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-R model MXR500-256",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-8-N32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-8-P32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-16-N32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC MX Controller MX-F model MXF100-16-P32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module RJ71GN11-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module RJ71GN11-SX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module RJ71GN11-EIP",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/local module FX5-CCLGN-MS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN interface board NZ81GN11-SX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN interface board NZ81GN11-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78G64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78GHV",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module RD78GHW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module FX5-40SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion module FX5-80SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion Control Board MR-EM441G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-32DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-32DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCF1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCF1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCE3-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GNCE3-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A4-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A4-16DE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A2-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A2-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A42-16DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN12A42-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2S1-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module NZ2GN2B1-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8D-K",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-8TE-K",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNSS2-16DTE-K",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNS12A2-14DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Block-type remote module with safety functions NZ2GNS12A2-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Analog-Digital converter module NZ2GN2S-60AD4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Analog-Digital converter module NZ2GN2B-60AD4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital-Analog converter module NZ2GN2S-60DA4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital-Analog converter module NZ2GN2B-60DA4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN compatible coupler NZ2FT-GN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FPGA module NZ2GN2S-D41P01",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FPGA module NZ2GN2S-D41D01",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FPGA module NZ2GN2S-D41PD02",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Tension meter LM7-1LG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Tension meter LM7-2LG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5W-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G-HS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G-RJ",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5-G-LL",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-J5D-G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-J5 MR-MD333G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-JET MR-JET-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AC Servo MELSERVO-JET MR-JET-G4-HS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-A8NCG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-A8NCG-S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-A800-GN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-E800-E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Inverter FR-A800/F800/E800 Series FR-E800-SCE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN expansion unit FCU8-EX569",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Computer MELIPC series MI2532-W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Computer MELIPC series MI2332-W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3715-FHCBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3712-WXCBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3715-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3715-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3712-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3712-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3710-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3710-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3708-XRBA",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT3000 Series GT3708-XRBD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Communication Unit GT25-J71GN13-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion Control Software SWM-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Motion Control Software SWM-G-N1",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Master/Local module Designated communication LSI NZ2GACP610-60",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP620-60",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP620-300",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP621-90",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote Station Communication LSI with GbE-PHY NZ2GACP621-720",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote station software development kit SW1DNC-GNSDK1S-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote station software development kit SW1DNC-GNSDK2S-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Liner Track System MTR-S series Linear track control module MTR-SCU00-4G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Liner Track System MTR-S series Linear track control module MTR-SCU00-PG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly."
}
],
"value": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Information Tampering and Denial-of-Service"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-04T03:56:05.662Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU98879231/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-211-07"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Information tampering and Denial-of-service (DoS) vulnerability in CC-Link IE TSN communication protocol",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2026-13584",
"datePublished": "2026-07-30T06:44:46.128Z",
"dateReserved": "2026-06-29T00:29:37.578Z",
"dateUpdated": "2026-08-04T03:56:05.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-12576 (GCVE-0-2026-12576)
Vulnerability from cvelistv5 – Published: 2026-07-01 07:01 – Updated: 2026-07-01 12:21
VLAI
EPSS
VEX
Title
DVP80ES3 Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability
Summary
DVP80ES3 with Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
1 reference
Impacted products
Date Public
2026-07-01 06:43
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-12576",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-01T12:21:21.101697Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T12:21:28.074Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DVP80ES3",
"vendor": "deltaww",
"versions": [
{
"lessThanOrEqual": "1.06.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:deltaww:dvp80es3:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.06.00",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Qian Zou, Ke Xu, Xuewei Feng, Qi Li, Xueying Li, and Gang Jin from Zhongguancun Laboratory"
}
],
"datePublic": "2026-07-01T06:43:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "DVP80ES3 with Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability."
}
],
"value": "DVP80ES3 with Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-596",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-596: TCP RST Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T07:01:17.903Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00009_DVP80ES3%20Multiple%20Vulnerabilities_v1%20(CVE-2026-12575,%2012576,%2012577).pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Users are recommended to update the device firmware to v01.08.10 or later."
}
],
"value": "Users are recommended to update the device firmware to v01.08.10 or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "DVP80ES3 Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2026-12576",
"datePublished": "2026-07-01T07:01:17.903Z",
"dateReserved": "2026-06-18T05:22:53.986Z",
"dateUpdated": "2026-07-01T12:21:28.074Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-29628 (GCVE-0-2025-29628)
Vulnerability from cvelistv5 – Published: 2025-07-25 00:00 – Updated: 2026-02-25 20:14
VLAI
EPSS
VEX
Summary
A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits.
Severity
9.4 (Critical)
8.1 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Gardyn | Home Kit Firmware |
Affected:
0 , < master.619
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-29628",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-25T20:21:30.343689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-25T20:23:05.205Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Home Kit Firmware",
"vendor": "Gardyn",
"versions": [
{
"lessThan": "master.619",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-25T20:14:40.989Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/mselbrede/gardyn/blob/main/CVE-2025-29628_CVE-2025-29631.md"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-055-03"
},
{
"url": "https://mygardyn.com/blog/security-update/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-29628",
"datePublished": "2025-07-25T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2026-02-25T20:14:40.989Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-0592 (GCVE-0-2025-0592)
Vulnerability from cvelistv5 – Published: 2025-02-14 20:16 – Updated: 2025-02-14 22:01
VLAI
EPSS
VEX
Title
SICK Lector8xx and InspectorP8xx vulnerable for code execution
Summary
The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by manipulating the firmware file and uploading it to the device.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://sick.com/psirt | x_SICK PSIRT Website |
| https://cdn.sick.com/media/docs/1/11/411/Special_… | x_ICS-CERT recommended practices on Industrial Security |
| https://www.cisa.gov/resources-tools/resources/ic… | x_ICS-CERT recommended practices on Industrial Security |
| https://www.first.org/cvss/calculator/3.1 | x_CVSS v3.1 Calculator |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisory |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisoryx_csaf |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| SICK AG | SICK Lector8xx |
Affected:
0 , < 2.4.0
(custom)
|
|
| SICK AG | SICK InspectorP8xx |
Affected:
0 , < 3.11.1
(custom)
|
Date Public
2025-02-14 20:15
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0592",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T22:00:51.950757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-14T22:01:00.488Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SICK Lector8xx",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SICK InspectorP8xx",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "3.11.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-02-14T20:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by manipulating the firmware file and uploading it to the device."
}
],
"value": "The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by manipulating the firmware file and uploading it to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-14T20:16:03.352Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"x_SICK PSIRT Website"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"x_ICS-CERT recommended practices on Industrial Security"
],
"url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
},
{
"tags": [
"x_ICS-CERT recommended practices on Industrial Security"
],
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"tags": [
"x_CVSS v3.1 Calculator"
],
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0002.pdf"
},
{
"tags": [
"vendor-advisory",
"x_csaf"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0002.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Users are strongly recommended to upgrade to the latest release of the Lector8xx (\u0026gt;=2.4.0)\nand the InspectorP8xx (\u0026gt;=3.11.1) respectively that includes a patch for the vulnerability. It is also\nrecommended to set a secure password, please refer to the respective operating instructions, linked in\nthe reference section.\n\n\n\u003cbr\u003e"
}
],
"value": "Users are strongly recommended to upgrade to the latest release of the Lector8xx (\u003e=2.4.0)\nand the InspectorP8xx (\u003e=3.11.1) respectively that includes a patch for the vulnerability. It is also\nrecommended to set a secure password, please refer to the respective operating instructions, linked in\nthe reference section."
}
],
"source": {
"advisory": "SCA-2025-0002",
"discovery": "INTERNAL"
},
"title": "SICK Lector8xx and InspectorP8xx vulnerable for code execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2025-0592",
"datePublished": "2025-02-14T20:16:03.352Z",
"dateReserved": "2025-01-20T06:40:46.494Z",
"dateUpdated": "2025-02-14T22:01:00.488Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52288 (GCVE-0-2024-52288)
Vulnerability from cvelistv5 – Published: 2024-11-11 19:10 – Updated: 2024-11-12 14:48
VLAI
EPSS
VEX
Title
RMAC revert to the beginning of the session in libosdp
Summary
libosdp is an implementation of IEC 60839-11-5 OSDP (Open Supervised Device Protocol) and provides a C library with support for C++, Rust and Python3. In affected versions an unexpected `REPLY_CCRYPT` or `REPLY_RMAC_I` may be introduced into an active stream when they should not be. Once RMAC_I message can be sent during a session, attacker with MITM access to the communication may intercept the original RMAC_I reply and save it. While the session continues, the attacker will record all of the replies and save them, till capturing the message to be replied (can be detected by ID, length or time based on inspection of visual activity next to the reader) Once attacker captures a session with the message to be replayed, he stops resetting the connection and waits for signal to perform the replay to of the PD to CP message (ex: by signaling remotely to the MIMT device or setting a specific timing). In order to replay, the attacker will craft a specific RMAC_I message in the proper seq of the execution, which will result in reverting the RMAC to the beginning of the session. At that phase - attacker can replay all the messages from the beginning of the session. This issue has been addressed in commit `298576d9` which is included in release version 3.0.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
Severity
5.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://github.com/goToMain/libosdp/security/advi… | x_refsource_CONFIRM |
| https://github.com/goToMain/libosdp/commit/298576… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52288",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:48:07.852440Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:48:17.830Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "libosdp",
"vendor": "goToMain",
"versions": [
{
"status": "affected",
"version": "\u003c 3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "libosdp is an implementation of IEC 60839-11-5 OSDP (Open Supervised Device Protocol) and provides a C library with support for C++, Rust and Python3. In affected versions an unexpected `REPLY_CCRYPT` or `REPLY_RMAC_I` may be introduced into an active stream when they should not be. Once RMAC_I message can be sent during a session, attacker with MITM access to the communication may intercept the original RMAC_I reply and save it. While the session continues, the attacker will record all of the replies and save them, till capturing the message to be replied (can be detected by ID, length or time based on inspection of visual activity next to the reader) Once attacker captures a session with the message to be replayed, he stops resetting the connection and waits for signal to perform the replay to of the PD to CP message (ex: by signaling remotely to the MIMT device or setting a specific timing). In order to replay, the attacker will craft a specific RMAC_I message in the proper seq of the execution, which will result in reverting the RMAC to the beginning of the session. At that phase - attacker can replay all the messages from the beginning of the session. This issue has been addressed in commit `298576d9` which is included in release version 3.0.0. Users are advised to upgrade. There are no known workarounds for this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-11T19:10:48.919Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/goToMain/libosdp/security/advisories/GHSA-xhjw-7vh5-qxqm",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/goToMain/libosdp/security/advisories/GHSA-xhjw-7vh5-qxqm"
},
{
"name": "https://github.com/goToMain/libosdp/commit/298576d9214b48214092eebdd892ec77be085e5a",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/goToMain/libosdp/commit/298576d9214b48214092eebdd892ec77be085e5a"
}
],
"source": {
"advisory": "GHSA-xhjw-7vh5-qxqm",
"discovery": "UNKNOWN"
},
"title": "RMAC revert to the beginning of the session in libosdp"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2024-52288",
"datePublished": "2024-11-11T19:10:48.919Z",
"dateReserved": "2024-11-06T19:00:26.393Z",
"dateUpdated": "2024-11-12T14:48:17.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43450 (GCVE-0-2024-43450)
Vulnerability from cvelistv5 – Published: 2024-11-12 17:53 – Updated: 2025-07-08 15:41
VLAI
EPSS
VEX
Title
Windows DNS Spoofing Vulnerability
Summary
Windows DNS Spoofing Vulnerability
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://msrc.microsoft.com/update-guide/vulnerabi… | vendor-advisory |
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| Microsoft | Windows Server 2019 |
Affected:
10.0.17763.0 , < 10.0.17763.6532
(custom)
|
|
| Microsoft | Windows Server 2019 (Server Core installation) |
Affected:
10.0.17763.0 , < 10.0.17763.6532
(custom)
|
|
| Microsoft | Windows Server 2022 |
Affected:
10.0.20348.0 , < 10.0.20348.2849
(custom)
|
|
| Microsoft | Windows Server 2022, 23H2 Edition (Server Core installation) |
Affected:
10.0.25398.0 , < 10.0.25398.1251
(custom)
|
|
| Microsoft | Windows Server 2016 |
Affected:
10.0.14393.0 , < 10.0.14393.7515
(custom)
|
|
| Microsoft | Windows Server 2016 (Server Core installation) |
Affected:
10.0.14393.0 , < 10.0.14393.7515
(custom)
|
|
| Microsoft | Windows Server 2008 R2 Service Pack 1 |
Affected:
6.1.7601.0 , < 6.1.7601.27415
(custom)
|
|
| Microsoft | Windows Server 2008 R2 Service Pack 1 (Server Core installation) |
Affected:
6.1.7601.0 , < 6.1.7601.27415
(custom)
|
|
| Microsoft | Windows Server 2012 |
Affected:
6.2.9200.0 , < 6.2.9200.25165
(custom)
|
|
| Microsoft | Windows Server 2012 (Server Core installation) |
Affected:
6.2.9200.0 , < 6.2.9200.25165
(custom)
|
|
| Microsoft | Windows Server 2012 R2 |
Affected:
6.3.9600.0 , < 6.3.9600.22267
(custom)
|
|
| Microsoft | Windows Server 2012 R2 (Server Core installation) |
Affected:
6.3.9600.0 , < 6.3.9600.22267
(custom)
|
|
| Microsoft | Windows Server 2025 |
Affected:
10.0.26100.0 , < 10.0.26100.2314
(custom)
|
|
| Microsoft | Windows Server 2025 (Server Core installation) |
Affected:
10.0.26100.0 , < 10.0.26100.2314
(custom)
|
Date Public
2024-11-12 08:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-43450",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T16:49:32.544991Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T16:49:39.286Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2019",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.6532",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2019 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.6532",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2022",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.20348.2849",
"status": "affected",
"version": "10.0.20348.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.25398.1251",
"status": "affected",
"version": "10.0.25398.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2016",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.7515",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2016 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.7515",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2008 R2 Service Pack 1",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.1.7601.27415",
"status": "affected",
"version": "6.1.7601.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2008 R2 Service Pack 1 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.1.7601.27415",
"status": "affected",
"version": "6.1.7601.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.2.9200.25165",
"status": "affected",
"version": "6.2.9200.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.2.9200.25165",
"status": "affected",
"version": "6.2.9200.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 R2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.3.9600.22267",
"status": "affected",
"version": "6.3.9600.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 R2 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.3.9600.22267",
"status": "affected",
"version": "6.3.9600.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2025",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.26100.2314",
"status": "affected",
"version": "10.0.26100.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2025 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.26100.2314",
"status": "affected",
"version": "10.0.26100.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.17763.6532",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.17763.6532",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.20348.2849",
"versionStartIncluding": "10.0.20348.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.25398.1251",
"versionStartIncluding": "10.0.25398.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.14393.7515",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.14393.7515",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2008_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.1.7601.27415",
"versionStartIncluding": "6.1.7601.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2008_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.1.7601.27415",
"versionStartIncluding": "6.1.7601.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.2.9200.25165",
"versionStartIncluding": "6.2.9200.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.2.9200.25165",
"versionStartIncluding": "6.2.9200.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.3.9600.22267",
"versionStartIncluding": "6.3.9600.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.3.9600.22267",
"versionStartIncluding": "6.3.9600.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.26100.2314",
"versionStartIncluding": "10.0.26100.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.26100.2314",
"versionStartIncluding": "10.0.26100.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"datePublic": "2024-11-12T08:00:00.000Z",
"descriptions": [
{
"lang": "en-US",
"value": "Windows DNS Spoofing Vulnerability"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T15:41:15.121Z",
"orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
"shortName": "microsoft"
},
"references": [
{
"name": "Windows DNS Spoofing Vulnerability",
"tags": [
"vendor-advisory"
],
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-43450"
}
],
"title": "Windows DNS Spoofing Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
"assignerShortName": "microsoft",
"cveId": "CVE-2024-43450",
"datePublished": "2024-11-12T17:53:48.450Z",
"dateReserved": "2024-08-14T01:08:33.514Z",
"dateUpdated": "2025-07-08T15:41:15.121Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12399 (GCVE-0-2024-12399)
Vulnerability from cvelistv5 – Published: 2025-01-17 09:37 – Updated: 2025-09-09 20:41
VLAI
EPSS
VEX
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability
exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs
man in the middle attack by intercepting the communication.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Pro-face GP-Pro EX |
Affected:
all version , < v5.00.100
(version)
|
|
| Schneider Electric | Pro-face Remote HMI |
Affected:
all versions , < v1.70.000
(version)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-17T13:19:08.787250Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T16:55:25.689Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Pro-face GP-Pro EX",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v5.00.100",
"status": "affected",
"version": "all version",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Pro-face Remote HMI",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v1.70.000",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication.\n\n\u003cbr\u003e"
}
],
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T20:41:23.793Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-12399",
"datePublished": "2025-01-17T09:37:35.734Z",
"dateReserved": "2024-12-10T09:21:04.278Z",
"dateUpdated": "2025-09-09T20:41:23.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8933 (GCVE-0-2024-8933)
Vulnerability from cvelistv5 – Published: 2024-11-13 04:06 – Updated: 2024-11-13 15:34
VLAI
EPSS
VEX
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel
vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of
confidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the
logical network while a valid user uploads or downloads a project file into the controller.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
1 reference
Impacted products
6 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
All versions
|
|
| Schneider Electric | Modicon MC80 (part numbers BMKC80) |
Affected:
All versions
|
|
| Schneider Electric | Modicon Momentum Unity M1E Processor (171CBU*) |
Affected:
All Versions
|
|
| schneider-electric | modicon_m340 |
Affected:
0 , < *
(custom)
cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* |
|
| schneider-electric | modicon_mc80 |
Affected:
0 , < *
(custom)
cpe:2.3:h:schneider-electric:modicon_mc80:-:*:*:*:*:*:*:* |
|
| schneider-electric | modicon_momentum_unity_m1e_processor |
Affected:
0 , < *
(custom)
cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m340",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicon_mc80:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_mc80",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_momentum_unity_m1e_processor",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8933",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-13T15:32:16.482241Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T15:34:19.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon MC80 (part numbers BMKC80)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Momentum Unity M1E Processor (171CBU*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel\nvulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of\nconfidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the\nlogical network while a valid user uploads or downloads a project file into the controller.\n\n\u003cbr\u003e"
}
],
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel\nvulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of\nconfidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the\nlogical network while a valid user uploads or downloads a project file into the controller."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T04:06:09.279Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/doc/SEVD-2024-317-02/SEVD-2024-317-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-8933",
"datePublished": "2024-11-13T04:06:09.279Z",
"dateReserved": "2024-09-17T07:30:30.190Z",
"dateUpdated": "2024-11-13T15:34:19.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-30565 (GCVE-0-2023-30565)
Vulnerability from cvelistv5 – Published: 2023-07-13 19:06 – Updated: 2024-10-22 15:36
VLAI
EPSS
VEX
Title
CQI Data Sniffing
Summary
An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Becton Dickinson & Co | CQI Reporter |
Affected:
0 , ≤ 10.17
(custom)
|
Date Public
2023-07-13 15:32
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:28:51.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-alaris-system-with-guardrails-suite-mx"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-30565",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-22T15:23:26.688644Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-22T15:36:36.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CQI Reporter",
"vendor": "Becton Dickinson \u0026 Co",
"versions": [
{
"lessThanOrEqual": "10.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-07-13T15:32:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker."
}
],
"value": "An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-26T15:51:18.816Z",
"orgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18",
"shortName": "BD"
},
"references": [
{
"url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-alaris-system-with-guardrails-suite-mx"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nBD recommends customers update to the BD Alaris\u00e2\u201e\u00a2 System v12.3, where available based on regulatory authorization. Customers who require software updates should contact their BD Account Executive to assist with scheduling the remediation.\n\n\u003cbr\u003e"
}
],
"value": "\nBD recommends customers update to the BD Alaris\u00e2\u201e\u00a2 System v12.3, where available based on regulatory authorization. Customers who require software updates should contact their BD Account Executive to assist with scheduling the remediation.\n\n\n"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": " CQI Data Sniffing ",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18",
"assignerShortName": "BD",
"cveId": "CVE-2023-30565",
"datePublished": "2023-07-13T19:06:18.280Z",
"dateReserved": "2023-04-12T16:30:07.537Z",
"dateUpdated": "2024-10-22T15:36:36.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.