ssa-962515
Vulnerability from csaf_siemens
Published
2024-05-14 00:00
Modified
2024-11-12 00:00
Summary
SSA-962515: Out of Bounds Read Vulnerability in Industrial Products
Notes
Summary
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition.
Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. \n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "category": "self", "summary": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-962515.json" } ], "title": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products", "tracking": { "current_release_date": "2024-11-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-962515", "initial_release_date": "2024-05-14T00:00:00Z", "revision_history": [ { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-07-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for SIMATIC NET PC Software V18, SIMATIC WinCC Runtime Professional V16, V18, and V19 and SIMATIC WinCC V7.5, and V8.0, and TIA Portal V18" }, { "date": "2024-09-10T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for SIMATIC PCS 7 V9.1, SIMATIC BATCH V9.1, SIMATIC WinCC Runtime Professional V17, SIMATIC Automation Tool, Simatic NET PC Software V16, SIMATIC Route Control V9.1 and SIMATIC PDM V9.2" }, { "date": "2024-10-08T00:00:00Z", "legacy_version": "1.3", "number": "4", "summary": "Added fix for SIMATIC NET PC Software V19" }, { "date": "2024-11-12T00:00:00Z", "legacy_version": "1.4", "number": "5", "summary": "Added fix for SINUMERIK PLC Programming Tool" } ], "status": "interim", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "S7-PCT", "product_id": "1" } } ], "category": "product_name", "name": "S7-PCT" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Security Configuration Tool (SCT)", "product_id": "2" } } ], "category": "product_name", "name": "Security Configuration Tool (SCT)" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V5.0 SP2", "product": { "name": "SIMATIC Automation Tool", "product_id": "3" } } ], "category": "product_name", "name": "SIMATIC Automation Tool" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.1 SP2 Upd5", "product": { "name": "SIMATIC BATCH V9.1", "product_id": "4" } } ], "category": "product_name", "name": "SIMATIC BATCH V9.1" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V16 Update 8", "product": { "name": "SIMATIC NET PC Software V16", "product_id": "5" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC NET PC Software V17", "product_id": "6" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 SP1", "product": { "name": "SIMATIC NET PC Software V18", "product_id": "7" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 2", "product": { "name": "SIMATIC NET PC Software V19", "product_id": "8" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V19" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.1 SP2 UC05", "product": { "name": "SIMATIC PCS 7 V9.1", "product_id": "9" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V9.1" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.2 SP2 Upd3", "product": { "name": "SIMATIC PDM V9.2", "product_id": "10" } } ], "category": "product_name", "name": "SIMATIC PDM V9.2" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.1 SP2 Upd3", "product": { "name": "SIMATIC Route Control V9.1", "product_id": "11" } } ], "category": "product_name", "name": "SIMATIC Route Control V9.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC STEP 7 V5", "product_id": "12" } } ], "category": "product_name", "name": "SIMATIC STEP 7 V5" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC OA V3.17", "product_id": "13" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.18 P025", "product": { "name": "SIMATIC WinCC OA V3.18", "product_id": "14" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.19 P010", "product": { "name": "SIMATIC WinCC OA V3.19", "product_id": "15" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Runtime Advanced", "product_id": "16" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Advanced" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V16 Update 6", "product": { "name": "SIMATIC WinCC Runtime Professional V16", "product_id": "17" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V16" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V17 Update 8", "product": { "name": "SIMATIC WinCC Runtime Professional V17", "product_id": "18" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 4", "product": { "name": "SIMATIC WinCC Runtime Professional V18", "product_id": "19" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 2", "product": { "name": "SIMATIC WinCC Runtime Professional V19", "product_id": "20" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Unified PC Runtime V18", "product_id": "21" } } ], "category": "product_name", "name": "SIMATIC WinCC Unified PC Runtime V18" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC V7.4", "product_id": "22" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.4" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V7.5 SP2 Update 17", "product": { "name": "SIMATIC WinCC V7.5", "product_id": "23" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.5" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V8.0 Update 5", "product": { "name": "SIMATIC WinCC V8.0", "product_id": "24" } } ], "category": "product_name", "name": "SIMATIC WinCC V8.0" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 SP1", "product": { "name": "SINAMICS Startdrive", "product_id": "25" } } ], "category": "product_name", "name": "SINAMICS Startdrive" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV6.23", "product": { "name": "SINUMERIK ONE virtual", "product_id": "26" } } ], "category": "product_name", "name": "SINUMERIK ONE virtual" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.3.12", "product": { "name": "SINUMERIK PLC Programming Tool", "product_id": "27" } } ], "category": "product_name", "name": "SINUMERIK PLC Programming Tool" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV2.0", "product": { "name": "TIA Portal Cloud Connector", "product_id": "28" } } ], "category": "product_name", "name": "TIA Portal Cloud Connector" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "product_id": "29" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "30" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "31" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 4", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "32" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 2", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V19", "product_id": "33" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V19" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "13", "22", "29", "30" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "6", "12", "16", "21", "31" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 6 or later version", "product_ids": [ "17" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 8 or later version", "product_ids": [ "5" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974091/" }, { "category": "vendor_fix", "details": "Update to V17 Update 8 or later version", "product_ids": [ "18" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 4 or later version", "product_ids": [ "32" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 4 or later version", "product_ids": [ "19" ] }, { "category": "vendor_fix", "details": "Update to V18 SP1 or later version", "product_ids": [ "7" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972655/" }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "33" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "20" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "8" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109975600/" }, { "category": "vendor_fix", "details": "Update to V19 SP1 or later version", "product_ids": [ "25" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109963196/" }, { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "28" ] }, { "category": "vendor_fix", "details": "Update to V3.18 P025 or later version", "product_ids": [ "14" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V3.19 P010 or later version", "product_ids": [ "15" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V3.3.12 or later version\nPLC Programming Tool V3.3.12 or later versions are integrated in SINUMERIK 828D Toolbox version V5.24 or later; Updated software version can be obtained from Siemens customer support or a local partner.", "product_ids": [ "27" ] }, { "category": "vendor_fix", "details": "Update to V5.0 SP2 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/98161300/" }, { "category": "vendor_fix", "details": "Update to V6.23 or later version", "product_ids": [ "26" ] }, { "category": "vendor_fix", "details": "Update to V7.5 SP2 Update 17 or later version", "product_ids": [ "23" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793460/" }, { "category": "vendor_fix", "details": "Update to V8.0 Update 5 or later version", "product_ids": [ "24" ] }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 UC05 or later version", "product_ids": [ "9" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 Upd3 or later version", "product_ids": [ "11" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 Upd5 or later version", "product_ids": [ "4" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.2 SP2 Upd3 or later version", "product_ids": [ "10" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33" ] } ], "title": "CVE-2023-46280" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.