Action not permitted
Modal body text goes here.
CVE-2023-46280
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-46280", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-29T14:20:28.448026Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:22:08.819Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.324Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Security Configuration Tool (SCT)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0 SP2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PDM V9.2", "vendor": "Siemens", "versions": [ { "lessThan": "V9.2 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PCT", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5 SP3 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7 SP3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.18", "vendor": "Siemens", "versions": [ { "lessThan": "V3.18 P025", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.19", "vendor": "Siemens", "versions": [ { "lessThan": "V3.19 P010", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "lessThan": "V19 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "lessThan": "V6.23", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK PLC Programming Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud Connector", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions \u003c V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions \u003c V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:28.579Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46280", "datePublished": "2024-05-14T10:01:52.069Z", "dateReserved": "2023-10-20T08:02:52.794Z", "dateUpdated": "2024-12-10T13:53:28.579Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-46280\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-05-14T16:15:40.800\",\"lastModified\":\"2024-12-10T14:30:35.147\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions \u003c V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions \u003c V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en: S7-PCT (todas las versiones),\\nSecurity Configuration Tool (SCT) (todas las versiones),\\nSIMATIC Automation Tool (todas las versiones),\\nSIMATIC BATCH V9.1 (todas las versiones),\\nSIMATIC NET PC Software (todas las versiones),\\nSIMATIC PCS 7 V9.1 (todas las versiones),\\nSIMATIC PDM V9.2 (todas las versiones),\\nSIMATIC Route Control V9.1 (todas las versiones),\\nSIMATIC STEP 7 V5 (todas las versiones),\\nSIMATIC WinCC OA V3.17 ( Todas las versiones),\\nSIMATIC WinCC OA V3.18 (todas las versiones \u0026lt; V3.18 P025),\\nSIMATIC WinCC OA V3.19 (todas las versiones \u0026lt; V3.19 P010),\\nSIMATIC WinCC Runtime Advanced (todas las versiones),\\nSIMATIC WinCC Runtime Professional V16 (Todas las versiones),\\nSIMATIC WinCC Runtime Professional V17 (todas las versiones),\\nSIMATIC WinCC Runtime Professional V18 (todas las versiones),\\nSIMATIC WinCC Runtime Professional V19 (todas las versiones),\\nSIMATIC WinCC Unified PC Runtime (todas las versiones),\\nSIMATIC WinCC V7.4 (Todas las versiones),\\nSIMATIC WinCC V7.5 (Todas las versiones),\\nSIMATIC WinCC V8.0 (Todas las versiones),\\nSINAMICS Startdrive (Todas las versiones \u0026lt; V19 SP1),\\nSINUMERIK ONE virtual (Todas las versiones \u0026lt; V6.23),\\nProgramaci\u00f3n de PLC SINUMERIK Herramienta (todas las versiones),\\nTIA Portal Cloud Connector (todas las versiones \u0026lt; V2.0),\\nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones),\\nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones),\\nTotally Portal de automatizaci\u00f3n integrado (TIA Portal) V17 (todas las versiones),\\nPortal de automatizaci\u00f3n totalmente integrado (Portal TIA) V18 (todas las versiones),\\nPortal de automatizaci\u00f3n totalmente integrado (TIA Portal) V19 (todas las versiones \"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":4.0}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-331112.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-784301.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-962515.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-962515.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
ssa-962515
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. \n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "category": "self", "summary": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-962515.json" } ], "title": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products", "tracking": { "current_release_date": "2024-11-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-962515", "initial_release_date": "2024-05-14T00:00:00Z", "revision_history": [ { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-07-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for SIMATIC NET PC Software V18, SIMATIC WinCC Runtime Professional V16, V18, and V19 and SIMATIC WinCC V7.5, and V8.0, and TIA Portal V18" }, { "date": "2024-09-10T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for SIMATIC PCS 7 V9.1, SIMATIC BATCH V9.1, SIMATIC WinCC Runtime Professional V17, SIMATIC Automation Tool, Simatic NET PC Software V16, SIMATIC Route Control V9.1 and SIMATIC PDM V9.2" }, { "date": "2024-10-08T00:00:00Z", "legacy_version": "1.3", "number": "4", "summary": "Added fix for SIMATIC NET PC Software V19" }, { "date": "2024-11-12T00:00:00Z", "legacy_version": "1.4", "number": "5", "summary": "Added fix for SINUMERIK PLC Programming Tool" } ], "status": "interim", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "S7-PCT", "product_id": "1" } } ], "category": "product_name", "name": "S7-PCT" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Security Configuration Tool (SCT)", "product_id": "2" } } ], "category": "product_name", "name": "Security Configuration Tool (SCT)" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V5.0 SP2", "product": { "name": "SIMATIC Automation Tool", "product_id": "3" } } ], "category": "product_name", "name": "SIMATIC Automation Tool" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.1 SP2 Upd5", "product": { "name": "SIMATIC BATCH V9.1", "product_id": "4" } } ], "category": "product_name", "name": "SIMATIC BATCH V9.1" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V16 Update 8", "product": { "name": "SIMATIC NET PC Software V16", "product_id": "5" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC NET PC Software V17", "product_id": "6" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 SP1", "product": { "name": "SIMATIC NET PC Software V18", "product_id": "7" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 2", "product": { "name": "SIMATIC NET PC Software V19", "product_id": "8" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V19" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.1 SP2 UC05", "product": { "name": "SIMATIC PCS 7 V9.1", "product_id": "9" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V9.1" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.2 SP2 Upd3", "product": { "name": "SIMATIC PDM V9.2", "product_id": "10" } } ], "category": "product_name", "name": "SIMATIC PDM V9.2" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V9.1 SP2 Upd3", "product": { "name": "SIMATIC Route Control V9.1", "product_id": "11" } } ], "category": "product_name", "name": "SIMATIC Route Control V9.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC STEP 7 V5", "product_id": "12" } } ], "category": "product_name", "name": "SIMATIC STEP 7 V5" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC OA V3.17", "product_id": "13" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.18 P025", "product": { "name": "SIMATIC WinCC OA V3.18", "product_id": "14" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.19 P010", "product": { "name": "SIMATIC WinCC OA V3.19", "product_id": "15" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Runtime Advanced", "product_id": "16" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Advanced" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V16 Update 6", "product": { "name": "SIMATIC WinCC Runtime Professional V16", "product_id": "17" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V16" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V17 Update 8", "product": { "name": "SIMATIC WinCC Runtime Professional V17", "product_id": "18" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 4", "product": { "name": "SIMATIC WinCC Runtime Professional V18", "product_id": "19" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 2", "product": { "name": "SIMATIC WinCC Runtime Professional V19", "product_id": "20" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Unified PC Runtime V18", "product_id": "21" } } ], "category": "product_name", "name": "SIMATIC WinCC Unified PC Runtime V18" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC V7.4", "product_id": "22" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.4" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V7.5 SP2 Update 17", "product": { "name": "SIMATIC WinCC V7.5", "product_id": "23" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.5" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V8.0 Update 5", "product": { "name": "SIMATIC WinCC V8.0", "product_id": "24" } } ], "category": "product_name", "name": "SIMATIC WinCC V8.0" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 SP1", "product": { "name": "SINAMICS Startdrive", "product_id": "25" } } ], "category": "product_name", "name": "SINAMICS Startdrive" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV6.23", "product": { "name": "SINUMERIK ONE virtual", "product_id": "26" } } ], "category": "product_name", "name": "SINUMERIK ONE virtual" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.3.12", "product": { "name": "SINUMERIK PLC Programming Tool", "product_id": "27" } } ], "category": "product_name", "name": "SINUMERIK PLC Programming Tool" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV2.0", "product": { "name": "TIA Portal Cloud Connector", "product_id": "28" } } ], "category": "product_name", "name": "TIA Portal Cloud Connector" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "product_id": "29" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "30" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "31" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 4", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "32" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 2", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V19", "product_id": "33" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V19" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "13", "22", "29", "30" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "6", "12", "16", "21", "31" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 6 or later version", "product_ids": [ "17" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 8 or later version", "product_ids": [ "5" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974091/" }, { "category": "vendor_fix", "details": "Update to V17 Update 8 or later version", "product_ids": [ "18" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 4 or later version", "product_ids": [ "32" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 4 or later version", "product_ids": [ "19" ] }, { "category": "vendor_fix", "details": "Update to V18 SP1 or later version", "product_ids": [ "7" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972655/" }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "33" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "20" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "8" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109975600/" }, { "category": "vendor_fix", "details": "Update to V19 SP1 or later version", "product_ids": [ "25" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109963196/" }, { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "28" ] }, { "category": "vendor_fix", "details": "Update to V3.18 P025 or later version", "product_ids": [ "14" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V3.19 P010 or later version", "product_ids": [ "15" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V3.3.12 or later version\nPLC Programming Tool V3.3.12 or later versions are integrated in SINUMERIK 828D Toolbox version V5.24 or later; Updated software version can be obtained from Siemens customer support or a local partner.", "product_ids": [ "27" ] }, { "category": "vendor_fix", "details": "Update to V5.0 SP2 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/98161300/" }, { "category": "vendor_fix", "details": "Update to V6.23 or later version", "product_ids": [ "26" ] }, { "category": "vendor_fix", "details": "Update to V7.5 SP2 Update 17 or later version", "product_ids": [ "23" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793460/" }, { "category": "vendor_fix", "details": "Update to V8.0 Update 5 or later version", "product_ids": [ "24" ] }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 UC05 or later version", "product_ids": [ "9" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 Upd3 or later version", "product_ids": [ "11" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 Upd5 or later version", "product_ids": [ "4" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.2 SP2 Upd3 or later version", "product_ids": [ "10" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33" ] } ], "title": "CVE-2023-46280" } ] }
ssa-784301
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEC NMS before V3.0 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEC NMS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "category": "self", "summary": "SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-784301.json" } ], "title": "SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.0", "tracking": { "current_release_date": "2024-08-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-784301", "initial_release_date": "2024-08-13T00:00:00Z", "revision_history": [ { "date": "2024-08-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0", "product": { "name": "SINEC NMS", "product_id": "1" } } ], "category": "product_name", "name": "SINEC NMS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-4611", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in mm/mempolicy.c in the memory management subsystem in the Linux Kernel. This issue is caused by a race between mbind() and VMA-locked page fault, and may allow a local attacker to crash the system or lead to a kernel information leak.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4611" }, { "cve": "CVE-2023-5868", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A memory disclosure vulnerability was found in PostgreSQL that allows remote users to access sensitive information by exploiting certain aggregate function calls with \u0027unknown\u0027-type arguments. Handling \u0027unknown\u0027-type values from string literals without type designation can disclose bytes, potentially revealing notable and confidential information. This issue exists due to excessive data output in aggregate function calls, enabling remote users to read some portion of system memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5868" }, { "cve": "CVE-2023-5869", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A flaw was found in PostgreSQL that allows authenticated database users to execute arbitrary code through missing overflow checks during SQL array value modification. This issue exists due to an integer overflow during array modification where a remote user can trigger the overflow by providing specially crafted data. This enables the execution of arbitrary code on the target system, allowing users to write arbitrary bytes to memory and extensively read the server\u0027s memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5869" }, { "cve": "CVE-2023-5870", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A flaw was found in PostgreSQL involving the pg_cancel_backend role that signals background workers, including the logical replication launcher, autovacuum workers, and the autovacuum launcher. Successful exploitation requires a non-core extension with a less-resilient background worker and would affect that specific background worker only. This issue may allow a remote high privileged user to launch a denial of service (DoS) attack.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5870" }, { "cve": "CVE-2023-6378", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A serialization vulnerability in logback receiver component part of logback version 1.4.11 allows an attacker to mount a Denial-Of-Service attack by sending poisoned data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-6378" }, { "cve": "CVE-2023-6481", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A serialization vulnerability in logback receiver component part of logback version 1.4.13, 1.3.13 and 1.2.12 allows an attacker to mount a Denial-Of-Service attack by sending poisoned data", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-6481" }, { "cve": "CVE-2023-31122", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Out-of-bounds Read vulnerability in mod_macro of Apache HTTP Server.This issue affects Apache HTTP Server: through 2.4.57.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-31122" }, { "cve": "CVE-2023-34050", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "summary", "text": "In spring AMQP versions 1.0.0 to 2.4.16 and 3.0.0 to 3.0.9 , allowed list patterns for deserializable class names were added to Spring AMQP, allowing users to lock down deserialization of data in messages from untrusted sources; however by default, when no allowed list was provided, all classes could be deserialized. Specifically, an application is vulnerable if \r\n\r\n * the SimpleMessageConverter or SerializerMessageConverter is used \r\n * the user does not configure allowed list patterns \r\n * untrusted message originators gain permissions to write messages to the RabbitMQ broker to send malicious content.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-34050" }, { "cve": "CVE-2023-39615", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Xmlsoft Libxml2 v2.11.0 was discovered to contain an out-of-bounds read via the xmlSAX2StartElement() function at /libxml2/SAX2.c. This vulnerability allows attackers to cause a Denial of Service (DoS) via supplying a crafted XML file. NOTE: the vendor\u0027s position is that the product does not support the legacy SAX1 interface with custom callbacks; there is a crash even without crafted input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-39615" }, { "cve": "CVE-2023-42794", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Incomplete Cleanup vulnerability in Apache Tomcat.\r\n\r\nThe internal fork of Commons FileUpload packaged with Apache Tomcat 9.0.70 through 9.0.80 and 8.5.85 through 8.5.93 included an unreleased, \r\nin progress refactoring that exposed a potential denial of service on \r\nWindows if a web application opened a stream for an uploaded file but \r\nfailed to close the stream. The file would never be deleted from disk \r\ncreating the possibility of an eventual denial of service due to the \r\ndisk being full.\r\n\r\nUsers are recommended to upgrade to version 9.0.81 onwards or 8.5.94 onwards, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-42794" }, { "cve": "CVE-2023-42795", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Incomplete Cleanup vulnerability in Apache Tomcat.When recycling various internal objects in Apache Tomcat from 11.0.0-M1 through 11.0.0-M11, from 10.1.0-M1 through 10.1.13, from 9.0.0-M1 through 9.0.80 and from 8.5.0 through 8.5.93, an error could \r\ncause Tomcat to skip some parts of the recycling process leading to \r\ninformation leaking from the current request/response to the next.\r\n\r\nUsers are recommended to upgrade to version 11.0.0-M12 onwards, 10.1.14 onwards, 9.0.81 onwards or 8.5.94 onwards, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-42795" }, { "cve": "CVE-2023-43622", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An attacker, opening a HTTP/2 connection with an initial window size of 0, was able to block handling of that connection indefinitely in Apache HTTP Server. This could be used to exhaust worker resources in the server, similar to the well known \"slow loris\" attack pattern.\r\nThis has been fixed in version 2.4.58, so that such connection are terminated properly after the configured connection timeout.\r\n\r\nThis issue affects Apache HTTP Server: from 2.4.55 through 2.4.57.\r\n\r\nUsers are recommended to upgrade to version 2.4.58, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-43622" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-45648", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Improper Input Validation vulnerability in Apache Tomcat.Tomcat\u00a0from 11.0.0-M1 through 11.0.0-M11, from 10.1.0-M1 through 10.1.13, from 9.0.0-M1 through 9.0.81 and from 8.5.0 through 8.5.93 did not correctly parse HTTP trailer headers. A specially \r\ncrafted, invalid trailer header could cause Tomcat to treat a single \r\nrequest as multiple requests leading to the possibility of request \r\nsmuggling when behind a reverse proxy.\r\n\r\nUsers are recommended to upgrade to version 11.0.0-M12 onwards, 10.1.14 onwards, 9.0.81 onwards or 8.5.94 onwards, which fix the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-45648" }, { "cve": "CVE-2023-45802", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "When a HTTP/2 stream was reset (RST frame) by a client, there was a time window were the request\u0027s memory resources were not reclaimed immediately. Instead, de-allocation was deferred to connection close. A client could send new requests and resets, keeping the connection busy and open and causing the memory footprint to keep on growing. On connection close, all resources were reclaimed, but the process might run out of memory before that.\r\n\r\nThis was found by the reporter during testing of CVE-2023-44487 (HTTP/2 Rapid Reset Exploit) with their own test client. During \"normal\" HTTP/2 use, the probability to hit this bug is very low. The kept memory would not become noticeable before the connection closes or times out.\r\n\r\nUsers are recommended to upgrade to version 2.4.58, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-45802" }, { "cve": "CVE-2023-46120", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The RabbitMQ Java client library allows Java and JVM-based applications to connect to and interact with RabbitMQ nodes. `maxBodyLebgth` was not used when receiving Message objects. Attackers could send a very large Message causing a memory overflow and triggering an OOM Error. Users of RabbitMQ may suffer from DoS attacks from RabbitMQ Java client which will ultimately exhaust the memory of the consumer. This vulnerability was patched in version 5.18.0.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46120" }, { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46280" }, { "cve": "CVE-2023-46589", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Improper Input Validation vulnerability in Apache Tomcat.Tomcat from 11.0.0-M1 through 11.0.0-M10, from 10.1.0-M1 through 10.1.15, from 9.0.0-M1 through 9.0.82 and from 8.5.0 through 8.5.95 did not correctly parse HTTP trailer headers. A trailer header that exceeded the header size limit could cause Tomcat to treat a single request as multiple requests leading to the possibility of request smuggling when behind a reverse proxy. Users are recommended to upgrade to version 11.0.0-M11 onwards, 10.1.16 onwards, 9.0.83 onwards or 8.5.96 onwards, which fix the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46589" }, { "cve": "CVE-2023-52425", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "libexpat through 2.5.0 allows a denial of service (resource consumption) because many full reparsings are required in the case of a large token for which multiple buffer fills are needed.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-52425" }, { "cve": "CVE-2023-52426", "cwe": { "id": "CWE-776", "name": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)" }, "notes": [ { "category": "summary", "text": "libexpat through 2.5.0 allows recursive XML Entity Expansion if XML_DTD is undefined at compile time.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-52426" }, { "cve": "CVE-2024-0985", "cwe": { "id": "CWE-271", "name": "Privilege Dropping / Lowering Errors" }, "notes": [ { "category": "summary", "text": "Late privilege drop in REFRESH MATERIALIZED VIEW CONCURRENTLY in PostgreSQL allows an object creator to execute arbitrary SQL functions as the command issuer. The command intends to run SQL functions as the owner of the materialized view, enabling safe refresh of untrusted materialized views. The victim is a superuser or member of one of the attacker\u0027s roles. The attack requires luring the victim into running REFRESH MATERIALIZED VIEW CONCURRENTLY on the attacker\u0027s materialized view. Versions before PostgreSQL 16.2, 15.6, 14.11, 13.14, and 12.18 are affected.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-0985" }, { "cve": "CVE-2024-25062", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "An issue was discovered in libxml2 before 2.11.7 and 2.12.x before 2.12.5. When using the XML Reader interface with DTD validation and XInclude expansion enabled, processing crafted XML documents can lead to an xmlValidatePopElement use-after-free.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-25062" }, { "cve": "CVE-2024-28182", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "nghttp2 is an implementation of the Hypertext Transfer Protocol version 2 in C. The nghttp2 library prior to version 1.61.0 keeps reading the unbounded number of HTTP/2 CONTINUATION frames even after a stream is reset to keep HPACK context in sync. This causes excessive CPU usage to decode HPACK stream. nghttp2 v1.61.0 mitigates this vulnerability by limiting the number of CONTINUATION frames it accepts per stream. There is no workaround for this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-28182" }, { "cve": "CVE-2024-28757", "cwe": { "id": "CWE-776", "name": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)" }, "notes": [ { "category": "summary", "text": "libexpat through 2.6.1 allows an XML Entity Expansion attack when there is isolated use of external parsers (created via XML_ExternalEntityParserCreate).", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-28757" }, { "cve": "CVE-2024-36398", "cwe": { "id": "CWE-250", "name": "Execution with Unnecessary Privileges" }, "notes": [ { "category": "summary", "text": "The affected application executes a subset of its services as `NT AUTHORITY\\SYSTEM`. This could allow a local attacker to execute operating system commands with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-36398" }, { "cve": "CVE-2024-41938", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "The importCertificate function of the SINEC NMS Control web application contains a path traversal vulnerability. This could allow an authenticated attacker it to delete arbitrary certificate files on the drive SINEC NMS is installed on.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-41938" }, { "cve": "CVE-2024-41939", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-41939" }, { "cve": "CVE-2024-41940", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected application does not properly validate user input to a privileged command queue. This could allow an authenticated attacker to execute OS commands with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-41940" }, { "cve": "CVE-2024-41941", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and modify settings in the application without authorization.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-41941" } ] }
ssa-331112
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEC NMS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" }, { "category": "self", "summary": "SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-331112.json" } ], "title": "SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP1", "tracking": { "current_release_date": "2024-11-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-331112", "initial_release_date": "2024-11-12T00:00:00Z", "revision_history": [ { "date": "2024-11-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.0 SP1", "product": { "name": "SINEC NMS", "product_id": "1" } } ], "category": "product_name", "name": "SINEC NMS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-4807", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Issue summary: The POLY1305 MAC (message authentication code) implementation contains a bug that might corrupt the internal state of applications on the Windows 64 platform when running on newer X86_64 processors supporting the AVX512-IFMA instructions. Impact summary: If in an application that uses the OpenSSL library an attacker can influence whether the POLY1305 MAC algorithm is used, the application state might be corrupted with various application dependent consequences. The POLY1305 MAC (message authentication code) implementation in OpenSSL does not save the contents of non-volatile XMM registers on Windows 64 platform when calculating the MAC of data larger than 64 bytes. Before returning to the caller all the XMM registers are set to zero rather than restoring their previous content. The vulnerable code is used only on newer x86_64 processors supporting the AVX512-IFMA instructions. The consequences of this kind of internal application state corruption can be various - from no consequences, if the calling application does not depend on the contents of non-volatile XMM registers at all, to the worst consequences, where the attacker could get complete control of the application process. However given the contents of the registers are just zeroized so the attacker cannot put arbitrary values inside, the most likely consequence, if any, would be an incorrect result of some application dependent calculations or a crash leading to a denial of service. The POLY1305 MAC algorithm is most frequently used as part of the CHACHA20-POLY1305 AEAD (authenticated encryption with associated data) algorithm. The most common usage of this AEAD cipher is with TLS protocol versions 1.2 and 1.3 and a malicious client can influence whether this AEAD cipher is used by the server. This implies that server applications using OpenSSL can be potentially impacted. However we are currently not aware of any concrete application that would be affected by this issue therefore we consider this a Low severity security issue. As a workaround the AVX512-IFMA instructions support can be disabled at runtime by setting the environment variable OPENSSL_ia32cap: OPENSSL_ia32cap=:~0x200000 The FIPS provider is not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4807" }, { "cve": "CVE-2023-5363", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Issue summary: A bug has been identified in the processing of key and initialisation vector (IV) lengths. This can lead to potential truncation or overruns during the initialisation of some symmetric ciphers.\r\n\r\nImpact summary: A truncation in the IV can result in non-uniqueness, which could result in loss of confidentiality for some cipher modes.\r\n\r\nWhen calling EVP_EncryptInit_ex2(), EVP_DecryptInit_ex2() or EVP_CipherInit_ex2() the provided OSSL_PARAM array is processed after the key and IV have been established. Any alterations to the key length, via the \"keylen\" parameter or the IV length, via the \"ivlen\" parameter, within the OSSL_PARAM array will not take effect as intended, potentially causing truncation or overreading of these values. The following ciphers and cipher modes are impacted: RC2, RC4, RC5, CCM, GCM and OCB.\r\n\r\nFor the CCM, GCM and OCB cipher modes, truncation of the IV can result in loss of confidentiality. For example, when following NIST\u0027s SP 800-38D section 8.2.1 guidance for constructing a deterministic IV for AES in GCM mode, truncation of the counter portion could lead to IV reuse.\r\n\r\nBoth truncations and overruns of the key and overruns of the IV will produce incorrect results and could, in some cases, trigger a memory exception. However, these issues are not currently assessed as security critical.\r\n\r\nChanging the key and/or IV lengths is not considered to be a common operation and the vulnerable API was recently introduced. Furthermore it is likely that application developers will have spotted this problem during testing since decryption would fail unless both peers in the communication were similarly vulnerable. For these reasons we expect the probability of an application being vulnerable to this to be quite low. However if an application is vulnerable then this issue is considered very serious. For these reasons we have assessed this issue as Moderate severity overall.\r\n\r\nThe OpenSSL SSL/TLS implementation is not affected by this issue.\r\n\r\nThe OpenSSL 3.0 and 3.1 FIPS providers are not affected by this because the issue lies outside of the FIPS provider boundary.\r\n\r\nOpenSSL 3.1 and 3.0 are vulnerable to this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5363" }, { "cve": "CVE-2023-5678", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Issue summary: Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn\u0027t make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn\u0027t check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial of Service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the \"-pubcheck\" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5678" }, { "cve": "CVE-2023-6129", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Issue summary: The POLY1305 MAC (message authentication code) implementation\r\ncontains a bug that might corrupt the internal state of applications running\r\non PowerPC CPU based platforms if the CPU provides vector instructions.\r\n\r\nImpact summary: If an attacker can influence whether the POLY1305 MAC\r\nalgorithm is used, the application state might be corrupted with various\r\napplication dependent consequences.\r\n\r\nThe POLY1305 MAC (message authentication code) implementation in OpenSSL for\r\nPowerPC CPUs restores the contents of vector registers in a different order\r\nthan they are saved. Thus the contents of some of these vector registers\r\nare corrupted when returning to the caller. The vulnerable code is used only\r\non newer PowerPC processors supporting the PowerISA 2.07 instructions.\r\n\r\nThe consequences of this kind of internal application state corruption can\r\nbe various - from no consequences, if the calling application does not\r\ndepend on the contents of non-volatile XMM registers at all, to the worst\r\nconsequences, where the attacker could get complete control of the application\r\nprocess. However unless the compiler uses the vector registers for storing\r\npointers, the most likely consequence, if any, would be an incorrect result\r\nof some application dependent calculations or a crash leading to a denial of\r\nservice.\r\n\r\nThe POLY1305 MAC algorithm is most frequently used as part of the\r\nCHACHA20-POLY1305 AEAD (authenticated encryption with associated data)\r\nalgorithm. The most common usage of this AEAD cipher is with TLS protocol\r\nversions 1.2 and 1.3. If this cipher is enabled on the server a malicious\r\nclient can influence whether this AEAD cipher is used. This implies that\r\nTLS server applications using OpenSSL can be potentially impacted. However\r\nwe are currently not aware of any concrete application that would be affected\r\nby this issue therefore we consider this a Low severity security issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-6129" }, { "cve": "CVE-2023-6237", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Issue summary: Checking excessively long invalid RSA public keys may take a long time. Impact summary: Applications that use the function EVP_PKEY_public_check() to check RSA public keys may experience long delays. Where the key that is being checked has been obtained from an untrusted source this may lead to a Denial of Service. When function EVP_PKEY_public_check() is called on RSA public keys, a computation is done to confirm that the RSA modulus, n, is composite. For valid RSA keys, n is a product of two or more large primes and this computation completes quickly. However, if n is an overly large prime, then this computation would take a long time. An application that calls EVP_PKEY_public_check() and supplies an RSA key obtained from an untrusted source could be vulnerable to a Denial of Service attack. The function EVP_PKEY_public_check() is not called from other OpenSSL functions however it is called from the OpenSSL pkey command line application. For that reason that application is also vulnerable if used with the \u0027-pubin\u0027 and \u0027-check\u0027 options on untrusted data. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-6237" }, { "cve": "CVE-2023-38709", "cwe": { "id": "CWE-113", "name": "Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Request/Response Splitting\u0027)" }, "notes": [ { "category": "summary", "text": "Faulty input validation in the core of Apache allows malicious or exploitable backend/content generators to split HTTP responses. This issue affects Apache HTTP Server: through 2.4.58.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-38709" }, { "cve": "CVE-2023-46218", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "This flaw allows a malicious HTTP server to set \"super cookies\" in curl that are then passed back to more origins than what is otherwise allowed or possible. This allows a site to set cookies that then would get sent to different and unrelated sites and domains. It could do this by exploiting a mixed case flaw in curl\u0027s function that verifies a given cookie domain against the Public Suffix List (PSL). For example a cookie could be set with `domain=co.UK` when the URL used a lower case hostname `curl.co.uk`, even though `co.uk` is listed as a PSL domain.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46218" }, { "cve": "CVE-2023-46219", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "When saving HSTS data to an excessively long file name, curl could end up removing all contents, making subsequent requests using that file unaware of the HSTS status they should otherwise use.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46219" }, { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46280" }, { "cve": "CVE-2024-0727", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Issue summary: Processing a maliciously formatted PKCS12 file may lead OpenSSL\r\nto crash leading to a potential Denial of Service attack\r\n\r\nImpact summary: Applications loading files in the PKCS12 format from untrusted\r\nsources might terminate abruptly.\r\n\r\nA file in PKCS12 format can contain certificates and keys and may come from an\r\nuntrusted source. The PKCS12 specification allows certain fields to be NULL, but\r\nOpenSSL does not correctly check for this case. This can lead to a NULL pointer\r\ndereference that results in OpenSSL crashing. If an application processes PKCS12\r\nfiles from an untrusted source using the OpenSSL APIs then that application will\r\nbe vulnerable to this issue.\r\n\r\nOpenSSL APIs that are vulnerable to this are: PKCS12_parse(),\r\nPKCS12_unpack_p7data(), PKCS12_unpack_p7encdata(), PKCS12_unpack_authsafes()\r\nand PKCS12_newpass().\r\n\r\nWe have also fixed a similar issue in SMIME_write_PKCS7(). However since this\r\nfunction is related to writing data we do not consider it security significant.\r\n\r\nThe FIPS modules in 3.2, 3.1 and 3.0 are not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-0727" }, { "cve": "CVE-2024-2004", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-2004" }, { "cve": "CVE-2024-2379", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "libcurl skips the certificate verification for a QUIC connection under certain conditions, when built to use wolfSSL. If told to use an unknown/bad cipher or curve, the error path accidentally skips the verification and returns OK, thus ignoring any certificate problems.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-2379" }, { "cve": "CVE-2024-2398", "cwe": { "id": "CWE-772", "name": "Missing Release of Resource after Effective Lifetime" }, "notes": [ { "category": "summary", "text": "When an application tells libcurl it wants to allow HTTP/2 server push, and the amount of received headers for the push surpasses the maximum allowed limit (1000), libcurl aborts the server push. When aborting, libcurl inadvertently does not free all the previously allocated headers and instead leaks the memory. Further, this error condition fails silently and is therefore not easily detected by an application.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-2398" }, { "cve": "CVE-2024-2466", "cwe": { "id": "CWE-297", "name": "Improper Validation of Certificate with Host Mismatch" }, "notes": [ { "category": "summary", "text": "libcurl did not check the server certificate of TLS connections done to a host specified as an IP address, when built to use mbedTLS. libcurl would wrongly avoid using the set hostname function when the specified hostname was given as an IP address, therefore completely skipping the certificate check. This affects all uses of TLS protocols (HTTPS, FTPS, IMAPS, POPS3, SMTPS, etc).", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-2466" }, { "cve": "CVE-2024-24795", "cwe": { "id": "CWE-113", "name": "Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Request/Response Splitting\u0027)" }, "notes": [ { "category": "summary", "text": "HTTP Response splitting in multiple modules in Apache HTTP Server allows an attacker that can inject malicious response headers into backend applications to cause an HTTP desynchronization attack. Users are recommended to upgrade to version 2.4.59, which fixes this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-24795" }, { "cve": "CVE-2024-27316", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "HTTP/2 incoming headers exceeding the limit are temporarily buffered in nghttp2 in order to generate an informative HTTP 413 response. If a client does not stop sending headers, this leads to memory exhaustion.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-27316" }, { "cve": "CVE-2024-47808", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system.\r\nThis could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-47808" } ] }
icsa-24-137-13
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "names": [ "Jongseong Kim", "Byunghyun Kang", "Sangjun Park", "Yunjin Park", "Kwon Yul", "Seungchan Kim" ], "organization": "Team today-0day (bob 12th)", "summary": "reporting this vulnerability to Siemens." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. \n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-962515.json" }, { "category": "self", "summary": "SSA-962515: Out of Bounds Read Vulnerability in Industrial Products - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "category": "self", "summary": "ICS Advisory ICSA-24-137-13 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-137-13.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-137-13 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-137-13" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Industrial Products", "tracking": { "current_release_date": "2024-11-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-24-137-13", "initial_release_date": "2024-05-14T00:00:00.000000Z", "revision_history": [ { "date": "2024-05-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-07-09T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for SIMATIC NET PC Software V18, SIMATIC WinCC Runtime Professional V16, V18, and V19 and SIMATIC WinCC V7.5, and V8.0, and TIA Portal V18" }, { "date": "2024-09-10T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for SIMATIC PCS 7 V9.1, SIMATIC BATCH V9.1, SIMATIC WinCC Runtime Professional V17, SIMATIC Automation Tool, Simatic NET PC Software V16, SIMATIC Route Control V9.1 and SIMATIC PDM V9.2" }, { "date": "2024-10-08T00:00:00.000000Z", "legacy_version": "1.3", "number": "4", "summary": "Added fix for SIMATIC NET PC Software V19" }, { "date": "2024-11-12T00:00:00.000000Z", "legacy_version": "1.4", "number": "5", "summary": "Added fix for SINUMERIK PLC Programming Tool" } ], "status": "final", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "S7-PCT", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "S7-PCT" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Security Configuration Tool (SCT)", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Security Configuration Tool (SCT)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.0_SP2", "product": { "name": "SIMATIC Automation Tool", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SIMATIC Automation Tool" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV9.1_SP2_Upd5", "product": { "name": "SIMATIC BATCH V9.1", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SIMATIC BATCH V9.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV16_Update_8", "product": { "name": "SIMATIC NET PC Software V16", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC NET PC Software V17", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V17" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV18_SP1", "product": { "name": "SIMATIC NET PC Software V18", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V18" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV19_Update_2", "product": { "name": "SIMATIC NET PC Software V19", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIMATIC NET PC Software V19" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV9.1_SP2_UC05", "product": { "name": "SIMATIC PCS 7 V9.1", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V9.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV9.2_SP2_Upd3", "product": { "name": "SIMATIC PDM V9.2", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "SIMATIC PDM V9.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV9.1_SP2_Upd3", "product": { "name": "SIMATIC Route Control V9.1", "product_id": "CSAFPID-0011" } } ], "category": "product_name", "name": "SIMATIC Route Control V9.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC STEP 7 V5", "product_id": "CSAFPID-0012" } } ], "category": "product_name", "name": "SIMATIC STEP 7 V5" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC OA V3.17", "product_id": "CSAFPID-0013" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.17" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.18_P025", "product": { "name": "SIMATIC WinCC OA V3.18", "product_id": "CSAFPID-0014" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.18" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.19_P010", "product": { "name": "SIMATIC WinCC OA V3.19", "product_id": "CSAFPID-0015" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Runtime Advanced", "product_id": "CSAFPID-0016" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Advanced" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV16_Update_6", "product": { "name": "SIMATIC WinCC Runtime Professional V16", "product_id": "CSAFPID-0017" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V16" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV17_Update_8", "product": { "name": "SIMATIC WinCC Runtime Professional V17", "product_id": "CSAFPID-0018" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V17" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV18_Update_4", "product": { "name": "SIMATIC WinCC Runtime Professional V18", "product_id": "CSAFPID-0019" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V18" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV19_Update_2", "product": { "name": "SIMATIC WinCC Runtime Professional V19", "product_id": "CSAFPID-0020" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Unified PC Runtime V18", "product_id": "CSAFPID-0021" } } ], "category": "product_name", "name": "SIMATIC WinCC Unified PC Runtime V18" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC V7.4", "product_id": "CSAFPID-0022" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.4" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV7.5_SP2_Update_17", "product": { "name": "SIMATIC WinCC V7.5", "product_id": "CSAFPID-0023" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.5" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0_Update_5", "product": { "name": "SIMATIC WinCC V8.0", "product_id": "CSAFPID-0024" } } ], "category": "product_name", "name": "SIMATIC WinCC V8.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV19_SP1", "product": { "name": "SINAMICS Startdrive", "product_id": "CSAFPID-0025" } } ], "category": "product_name", "name": "SINAMICS Startdrive" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV6.23", "product": { "name": "SINUMERIK ONE virtual", "product_id": "CSAFPID-0026" } } ], "category": "product_name", "name": "SINUMERIK ONE virtual" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.3.12", "product": { "name": "SINUMERIK PLC Programming Tool", "product_id": "CSAFPID-0027" } } ], "category": "product_name", "name": "SINUMERIK PLC Programming Tool" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV2.0", "product": { "name": "TIA Portal Cloud Connector", "product_id": "CSAFPID-0028" } } ], "category": "product_name", "name": "TIA Portal Cloud Connector" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "product_id": "CSAFPID-0029" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "CSAFPID-0030" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "CSAFPID-0031" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV18_Update_4", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "CSAFPID-0032" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV19_Update_2", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V19", "product_id": "CSAFPID-0033" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V19" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002", "CSAFPID-0013", "CSAFPID-0022", "CSAFPID-0029", "CSAFPID-0030" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001", "CSAFPID-0006", "CSAFPID-0012", "CSAFPID-0016", "CSAFPID-0021", "CSAFPID-0031" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 6 or later version", "product_ids": [ "CSAFPID-0017" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 8 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974091/" }, { "category": "vendor_fix", "details": "Update to V17 Update 8 or later version", "product_ids": [ "CSAFPID-0018" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 4 or later version", "product_ids": [ "CSAFPID-0032" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 4 or later version", "product_ids": [ "CSAFPID-0019" ] }, { "category": "vendor_fix", "details": "Update to V18 SP1 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972655/" }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "CSAFPID-0033" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "CSAFPID-0020" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109975600/" }, { "category": "vendor_fix", "details": "Update to V19 SP1 or later version", "product_ids": [ "CSAFPID-0025" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109963196/" }, { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0028" ] }, { "category": "vendor_fix", "details": "Update to V3.18 P025 or later version", "product_ids": [ "CSAFPID-0014" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V3.19 P010 or later version", "product_ids": [ "CSAFPID-0015" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V3.3.12 or later version\nPLC Programming Tool V3.3.12 or later versions are integrated in SINUMERIK 828D Toolbox version V5.24 or later; Updated software version can be obtained from Siemens customer support or a local partner.", "product_ids": [ "CSAFPID-0027" ] }, { "category": "vendor_fix", "details": "Update to V5.0 SP2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/98161300/" }, { "category": "vendor_fix", "details": "Update to V6.23 or later version", "product_ids": [ "CSAFPID-0026" ] }, { "category": "vendor_fix", "details": "Update to V7.5 SP2 Update 17 or later version", "product_ids": [ "CSAFPID-0023" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793460/" }, { "category": "vendor_fix", "details": "Update to V8.0 Update 5 or later version", "product_ids": [ "CSAFPID-0024" ] }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 UC05 or later version", "product_ids": [ "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 Upd3 or later version", "product_ids": [ "CSAFPID-0011" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.1 SP2 Upd5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" }, { "category": "vendor_fix", "details": "Update to V9.2 SP2 Upd3 or later version", "product_ids": [ "CSAFPID-0010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812242/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033" ] } ], "title": "CVE-2023-46280" } ] }
icsa-24-228-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEC NMS before V3.0 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEC NMS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-784301.json" }, { "category": "self", "summary": "SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "category": "self", "summary": "ICS Advisory ICSA-24-228-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-228-06 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINEC NMS", "tracking": { "current_release_date": "2024-08-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-228-06", "initial_release_date": "2024-08-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-08-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0", "product": { "name": "SINEC NMS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEC NMS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-4611", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in mm/mempolicy.c in the memory management subsystem in the Linux Kernel. This issue is caused by a race between mbind() and VMA-locked page fault, and may allow a local attacker to crash the system or lead to a kernel information leak.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-4611" }, { "cve": "CVE-2023-5868", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A memory disclosure vulnerability was found in PostgreSQL that allows remote users to access sensitive information by exploiting certain aggregate function calls with \u0027unknown\u0027-type arguments. Handling \u0027unknown\u0027-type values from string literals without type designation can disclose bytes, potentially revealing notable and confidential information. This issue exists due to excessive data output in aggregate function calls, enabling remote users to read some portion of system memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-5868" }, { "cve": "CVE-2023-5869", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A flaw was found in PostgreSQL that allows authenticated database users to execute arbitrary code through missing overflow checks during SQL array value modification. This issue exists due to an integer overflow during array modification where a remote user can trigger the overflow by providing specially crafted data. This enables the execution of arbitrary code on the target system, allowing users to write arbitrary bytes to memory and extensively read the server\u0027s memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-5869" }, { "cve": "CVE-2023-5870", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A flaw was found in PostgreSQL involving the pg_cancel_backend role that signals background workers, including the logical replication launcher, autovacuum workers, and the autovacuum launcher. Successful exploitation requires a non-core extension with a less-resilient background worker and would affect that specific background worker only. This issue may allow a remote high privileged user to launch a denial of service (DoS) attack.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-5870" }, { "cve": "CVE-2023-6378", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A serialization vulnerability in logback receiver component part of logback version 1.4.11 allows an attacker to mount a Denial-Of-Service attack by sending poisoned data.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-6378" }, { "cve": "CVE-2023-6481", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A serialization vulnerability in logback receiver component part of logback version 1.4.13, 1.3.13 and 1.2.12 allows an attacker to mount a Denial-Of-Service attack by sending poisoned data", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-6481" }, { "cve": "CVE-2023-31122", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Out-of-bounds Read vulnerability in mod_macro of Apache HTTP Server.This issue affects Apache HTTP Server: through 2.4.57.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-31122" }, { "cve": "CVE-2023-34050", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "summary", "text": "In spring AMQP versions 1.0.0 to 2.4.16 and 3.0.0 to 3.0.9 , allowed list patterns for deserializable class names were added to Spring AMQP, allowing users to lock down deserialization of data in messages from untrusted sources; however by default, when no allowed list was provided, all classes could be deserialized. Specifically, an application is vulnerable if \r\n\r\n * the SimpleMessageConverter or SerializerMessageConverter is used \r\n * the user does not configure allowed list patterns \r\n * untrusted message originators gain permissions to write messages to the RabbitMQ broker to send malicious content.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-34050" }, { "cve": "CVE-2023-39615", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Xmlsoft Libxml2 v2.11.0 was discovered to contain an out-of-bounds read via the xmlSAX2StartElement() function at /libxml2/SAX2.c. This vulnerability allows attackers to cause a Denial of Service (DoS) via supplying a crafted XML file. NOTE: the vendor\u0027s position is that the product does not support the legacy SAX1 interface with custom callbacks; there is a crash even without crafted input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-39615" }, { "cve": "CVE-2023-42794", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Incomplete Cleanup vulnerability in Apache Tomcat.\r\n\r\nThe internal fork of Commons FileUpload packaged with Apache Tomcat 9.0.70 through 9.0.80 and 8.5.85 through 8.5.93 included an unreleased, \r\nin progress refactoring that exposed a potential denial of service on \r\nWindows if a web application opened a stream for an uploaded file but \r\nfailed to close the stream. The file would never be deleted from disk \r\ncreating the possibility of an eventual denial of service due to the \r\ndisk being full.\r\n\r\nUsers are recommended to upgrade to version 9.0.81 onwards or 8.5.94 onwards, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-42794" }, { "cve": "CVE-2023-42795", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Incomplete Cleanup vulnerability in Apache Tomcat.When recycling various internal objects in Apache Tomcat from 11.0.0-M1 through 11.0.0-M11, from 10.1.0-M1 through 10.1.13, from 9.0.0-M1 through 9.0.80 and from 8.5.0 through 8.5.93, an error could \r\ncause Tomcat to skip some parts of the recycling process leading to \r\ninformation leaking from the current request/response to the next.\r\n\r\nUsers are recommended to upgrade to version 11.0.0-M12 onwards, 10.1.14 onwards, 9.0.81 onwards or 8.5.94 onwards, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-42795" }, { "cve": "CVE-2023-43622", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An attacker, opening a HTTP/2 connection with an initial window size of 0, was able to block handling of that connection indefinitely in Apache HTTP Server. This could be used to exhaust worker resources in the server, similar to the well known \"slow loris\" attack pattern.\r\nThis has been fixed in version 2.4.58, so that such connection are terminated properly after the configured connection timeout.\r\n\r\nThis issue affects Apache HTTP Server: from 2.4.55 through 2.4.57.\r\n\r\nUsers are recommended to upgrade to version 2.4.58, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-43622" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-45648", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Improper Input Validation vulnerability in Apache Tomcat.Tomcat\u00a0from 11.0.0-M1 through 11.0.0-M11, from 10.1.0-M1 through 10.1.13, from 9.0.0-M1 through 9.0.81 and from 8.5.0 through 8.5.93 did not correctly parse HTTP trailer headers. A specially \r\ncrafted, invalid trailer header could cause Tomcat to treat a single \r\nrequest as multiple requests leading to the possibility of request \r\nsmuggling when behind a reverse proxy.\r\n\r\nUsers are recommended to upgrade to version 11.0.0-M12 onwards, 10.1.14 onwards, 9.0.81 onwards or 8.5.94 onwards, which fix the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-45648" }, { "cve": "CVE-2023-45802", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "When a HTTP/2 stream was reset (RST frame) by a client, there was a time window were the request\u0027s memory resources were not reclaimed immediately. Instead, de-allocation was deferred to connection close. A client could send new requests and resets, keeping the connection busy and open and causing the memory footprint to keep on growing. On connection close, all resources were reclaimed, but the process might run out of memory before that.\r\n\r\nThis was found by the reporter during testing of CVE-2023-44487 (HTTP/2 Rapid Reset Exploit) with their own test client. During \"normal\" HTTP/2 use, the probability to hit this bug is very low. The kept memory would not become noticeable before the connection closes or times out.\r\n\r\nUsers are recommended to upgrade to version 2.4.58, which fixes the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-45802" }, { "cve": "CVE-2023-46120", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The RabbitMQ Java client library allows Java and JVM-based applications to connect to and interact with RabbitMQ nodes. `maxBodyLebgth` was not used when receiving Message objects. Attackers could send a very large Message causing a memory overflow and triggering an OOM Error. Users of RabbitMQ may suffer from DoS attacks from RabbitMQ Java client which will ultimately exhaust the memory of the consumer. This vulnerability was patched in version 5.18.0.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-46120" }, { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-46280" }, { "cve": "CVE-2023-46589", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Improper Input Validation vulnerability in Apache Tomcat.Tomcat from 11.0.0-M1 through 11.0.0-M10, from 10.1.0-M1 through 10.1.15, from 9.0.0-M1 through 9.0.82 and from 8.5.0 through 8.5.95 did not correctly parse HTTP trailer headers. A trailer header that exceeded the header size limit could cause Tomcat to treat a single request as multiple requests leading to the possibility of request smuggling when behind a reverse proxy. Users are recommended to upgrade to version 11.0.0-M11 onwards, 10.1.16 onwards, 9.0.83 onwards or 8.5.96 onwards, which fix the issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-46589" }, { "cve": "CVE-2023-52425", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "libexpat through 2.5.0 allows a denial of service (resource consumption) because many full reparsings are required in the case of a large token for which multiple buffer fills are needed.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-52425" }, { "cve": "CVE-2023-52426", "cwe": { "id": "CWE-776", "name": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)" }, "notes": [ { "category": "summary", "text": "libexpat through 2.5.0 allows recursive XML Entity Expansion if XML_DTD is undefined at compile time.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-52426" }, { "cve": "CVE-2024-0985", "cwe": { "id": "CWE-271", "name": "Privilege Dropping / Lowering Errors" }, "notes": [ { "category": "summary", "text": "Late privilege drop in REFRESH MATERIALIZED VIEW CONCURRENTLY in PostgreSQL allows an object creator to execute arbitrary SQL functions as the command issuer. The command intends to run SQL functions as the owner of the materialized view, enabling safe refresh of untrusted materialized views. The victim is a superuser or member of one of the attacker\u0027s roles. The attack requires luring the victim into running REFRESH MATERIALIZED VIEW CONCURRENTLY on the attacker\u0027s materialized view. Versions before PostgreSQL 16.2, 15.6, 14.11, 13.14, and 12.18 are affected.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-0985" }, { "cve": "CVE-2024-25062", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "An issue was discovered in libxml2 before 2.11.7 and 2.12.x before 2.12.5. When using the XML Reader interface with DTD validation and XInclude expansion enabled, processing crafted XML documents can lead to an xmlValidatePopElement use-after-free.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-25062" }, { "cve": "CVE-2024-28182", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "nghttp2 is an implementation of the Hypertext Transfer Protocol version 2 in C. The nghttp2 library prior to version 1.61.0 keeps reading the unbounded number of HTTP/2 CONTINUATION frames even after a stream is reset to keep HPACK context in sync. This causes excessive CPU usage to decode HPACK stream. nghttp2 v1.61.0 mitigates this vulnerability by limiting the number of CONTINUATION frames it accepts per stream. There is no workaround for this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-28182" }, { "cve": "CVE-2024-28757", "cwe": { "id": "CWE-776", "name": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)" }, "notes": [ { "category": "summary", "text": "libexpat through 2.6.1 allows an XML Entity Expansion attack when there is isolated use of external parsers (created via XML_ExternalEntityParserCreate).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-28757" }, { "cve": "CVE-2024-36398", "cwe": { "id": "CWE-250", "name": "Execution with Unnecessary Privileges" }, "notes": [ { "category": "summary", "text": "The affected application executes a subset of its services as `NT AUTHORITY\\SYSTEM`. This could allow a local attacker to execute operating system commands with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-36398" }, { "cve": "CVE-2024-41938", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "The importCertificate function of the SINEC NMS Control web application contains a path traversal vulnerability. This could allow an authenticated attacker it to delete arbitrary certificate files on the drive SINEC NMS is installed on.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-41938" }, { "cve": "CVE-2024-41939", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-41939" }, { "cve": "CVE-2024-41940", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected application does not properly validate user input to a privileged command queue. This could allow an authenticated attacker to execute OS commands with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-41940" }, { "cve": "CVE-2024-41941", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and modify settings in the application without authorization.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109973059/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-41941" } ] }
icsa-24-319-04
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEC NMS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-331112.json" }, { "category": "self", "summary": "SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" }, { "category": "self", "summary": "ICS Advisory ICSA-24-319-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-319-04.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-319-04 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-319-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINEC NMS", "tracking": { "current_release_date": "2024-11-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-24-319-04", "initial_release_date": "2024-11-12T00:00:00.000000Z", "revision_history": [ { "date": "2024-11-12T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0_SP1", "product": { "name": "SINEC NMS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEC NMS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-4807", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Issue summary: The POLY1305 MAC (message authentication code) implementation contains a bug that might corrupt the internal state of applications on the Windows 64 platform when running on newer X86_64 processors supporting the AVX512-IFMA instructions. Impact summary: If in an application that uses the OpenSSL library an attacker can influence whether the POLY1305 MAC algorithm is used, the application state might be corrupted with various application dependent consequences. The POLY1305 MAC (message authentication code) implementation in OpenSSL does not save the contents of non-volatile XMM registers on Windows 64 platform when calculating the MAC of data larger than 64 bytes. Before returning to the caller all the XMM registers are set to zero rather than restoring their previous content. The vulnerable code is used only on newer x86_64 processors supporting the AVX512-IFMA instructions. The consequences of this kind of internal application state corruption can be various - from no consequences, if the calling application does not depend on the contents of non-volatile XMM registers at all, to the worst consequences, where the attacker could get complete control of the application process. However given the contents of the registers are just zeroized so the attacker cannot put arbitrary values inside, the most likely consequence, if any, would be an incorrect result of some application dependent calculations or a crash leading to a denial of service. The POLY1305 MAC algorithm is most frequently used as part of the CHACHA20-POLY1305 AEAD (authenticated encryption with associated data) algorithm. The most common usage of this AEAD cipher is with TLS protocol versions 1.2 and 1.3 and a malicious client can influence whether this AEAD cipher is used by the server. This implies that server applications using OpenSSL can be potentially impacted. However we are currently not aware of any concrete application that would be affected by this issue therefore we consider this a Low severity security issue. As a workaround the AVX512-IFMA instructions support can be disabled at runtime by setting the environment variable OPENSSL_ia32cap: OPENSSL_ia32cap=:~0x200000 The FIPS provider is not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-4807" }, { "cve": "CVE-2023-5363", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Issue summary: A bug has been identified in the processing of key and initialisation vector (IV) lengths. This can lead to potential truncation or overruns during the initialisation of some symmetric ciphers.\r\n\r\nImpact summary: A truncation in the IV can result in non-uniqueness, which could result in loss of confidentiality for some cipher modes.\r\n\r\nWhen calling EVP_EncryptInit_ex2(), EVP_DecryptInit_ex2() or EVP_CipherInit_ex2() the provided OSSL_PARAM array is processed after the key and IV have been established. Any alterations to the key length, via the \"keylen\" parameter or the IV length, via the \"ivlen\" parameter, within the OSSL_PARAM array will not take effect as intended, potentially causing truncation or overreading of these values. The following ciphers and cipher modes are impacted: RC2, RC4, RC5, CCM, GCM and OCB.\r\n\r\nFor the CCM, GCM and OCB cipher modes, truncation of the IV can result in loss of confidentiality. For example, when following NIST\u0027s SP 800-38D section 8.2.1 guidance for constructing a deterministic IV for AES in GCM mode, truncation of the counter portion could lead to IV reuse.\r\n\r\nBoth truncations and overruns of the key and overruns of the IV will produce incorrect results and could, in some cases, trigger a memory exception. However, these issues are not currently assessed as security critical.\r\n\r\nChanging the key and/or IV lengths is not considered to be a common operation and the vulnerable API was recently introduced. Furthermore it is likely that application developers will have spotted this problem during testing since decryption would fail unless both peers in the communication were similarly vulnerable. For these reasons we expect the probability of an application being vulnerable to this to be quite low. However if an application is vulnerable then this issue is considered very serious. For these reasons we have assessed this issue as Moderate severity overall.\r\n\r\nThe OpenSSL SSL/TLS implementation is not affected by this issue.\r\n\r\nThe OpenSSL 3.0 and 3.1 FIPS providers are not affected by this because the issue lies outside of the FIPS provider boundary.\r\n\r\nOpenSSL 3.1 and 3.0 are vulnerable to this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-5363" }, { "cve": "CVE-2023-5678", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Issue summary: Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn\u0027t make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn\u0027t check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial of Service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the \"-pubcheck\" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-5678" }, { "cve": "CVE-2023-6129", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Issue summary: The POLY1305 MAC (message authentication code) implementation\r\ncontains a bug that might corrupt the internal state of applications running\r\non PowerPC CPU based platforms if the CPU provides vector instructions.\r\n\r\nImpact summary: If an attacker can influence whether the POLY1305 MAC\r\nalgorithm is used, the application state might be corrupted with various\r\napplication dependent consequences.\r\n\r\nThe POLY1305 MAC (message authentication code) implementation in OpenSSL for\r\nPowerPC CPUs restores the contents of vector registers in a different order\r\nthan they are saved. Thus the contents of some of these vector registers\r\nare corrupted when returning to the caller. The vulnerable code is used only\r\non newer PowerPC processors supporting the PowerISA 2.07 instructions.\r\n\r\nThe consequences of this kind of internal application state corruption can\r\nbe various - from no consequences, if the calling application does not\r\ndepend on the contents of non-volatile XMM registers at all, to the worst\r\nconsequences, where the attacker could get complete control of the application\r\nprocess. However unless the compiler uses the vector registers for storing\r\npointers, the most likely consequence, if any, would be an incorrect result\r\nof some application dependent calculations or a crash leading to a denial of\r\nservice.\r\n\r\nThe POLY1305 MAC algorithm is most frequently used as part of the\r\nCHACHA20-POLY1305 AEAD (authenticated encryption with associated data)\r\nalgorithm. The most common usage of this AEAD cipher is with TLS protocol\r\nversions 1.2 and 1.3. If this cipher is enabled on the server a malicious\r\nclient can influence whether this AEAD cipher is used. This implies that\r\nTLS server applications using OpenSSL can be potentially impacted. However\r\nwe are currently not aware of any concrete application that would be affected\r\nby this issue therefore we consider this a Low severity security issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-6129" }, { "cve": "CVE-2023-6237", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Issue summary: Checking excessively long invalid RSA public keys may take a long time. Impact summary: Applications that use the function EVP_PKEY_public_check() to check RSA public keys may experience long delays. Where the key that is being checked has been obtained from an untrusted source this may lead to a Denial of Service. When function EVP_PKEY_public_check() is called on RSA public keys, a computation is done to confirm that the RSA modulus, n, is composite. For valid RSA keys, n is a product of two or more large primes and this computation completes quickly. However, if n is an overly large prime, then this computation would take a long time. An application that calls EVP_PKEY_public_check() and supplies an RSA key obtained from an untrusted source could be vulnerable to a Denial of Service attack. The function EVP_PKEY_public_check() is not called from other OpenSSL functions however it is called from the OpenSSL pkey command line application. For that reason that application is also vulnerable if used with the \u0027-pubin\u0027 and \u0027-check\u0027 options on untrusted data. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-6237" }, { "cve": "CVE-2023-38709", "cwe": { "id": "CWE-113", "name": "Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Request/Response Splitting\u0027)" }, "notes": [ { "category": "summary", "text": "Faulty input validation in the core of Apache allows malicious or exploitable backend/content generators to split HTTP responses. This issue affects Apache HTTP Server: through 2.4.58.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-38709" }, { "cve": "CVE-2023-46218", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "This flaw allows a malicious HTTP server to set \"super cookies\" in curl that are then passed back to more origins than what is otherwise allowed or possible. This allows a site to set cookies that then would get sent to different and unrelated sites and domains. It could do this by exploiting a mixed case flaw in curl\u0027s function that verifies a given cookie domain against the Public Suffix List (PSL). For example a cookie could be set with `domain=co.UK` when the URL used a lower case hostname `curl.co.uk`, even though `co.uk` is listed as a PSL domain.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-46218" }, { "cve": "CVE-2023-46219", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "When saving HSTS data to an excessively long file name, curl could end up removing all contents, making subsequent requests using that file unaware of the HSTS status they should otherwise use.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-46219" }, { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-46280" }, { "cve": "CVE-2024-0727", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Issue summary: Processing a maliciously formatted PKCS12 file may lead OpenSSL\r\nto crash leading to a potential Denial of Service attack\r\n\r\nImpact summary: Applications loading files in the PKCS12 format from untrusted\r\nsources might terminate abruptly.\r\n\r\nA file in PKCS12 format can contain certificates and keys and may come from an\r\nuntrusted source. The PKCS12 specification allows certain fields to be NULL, but\r\nOpenSSL does not correctly check for this case. This can lead to a NULL pointer\r\ndereference that results in OpenSSL crashing. If an application processes PKCS12\r\nfiles from an untrusted source using the OpenSSL APIs then that application will\r\nbe vulnerable to this issue.\r\n\r\nOpenSSL APIs that are vulnerable to this are: PKCS12_parse(),\r\nPKCS12_unpack_p7data(), PKCS12_unpack_p7encdata(), PKCS12_unpack_authsafes()\r\nand PKCS12_newpass().\r\n\r\nWe have also fixed a similar issue in SMIME_write_PKCS7(). However since this\r\nfunction is related to writing data we do not consider it security significant.\r\n\r\nThe FIPS modules in 3.2, 3.1 and 3.0 are not affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-0727" }, { "cve": "CVE-2024-2004", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-2004" }, { "cve": "CVE-2024-2379", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "libcurl skips the certificate verification for a QUIC connection under certain conditions, when built to use wolfSSL. If told to use an unknown/bad cipher or curve, the error path accidentally skips the verification and returns OK, thus ignoring any certificate problems.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-2379" }, { "cve": "CVE-2024-2398", "cwe": { "id": "CWE-772", "name": "Missing Release of Resource after Effective Lifetime" }, "notes": [ { "category": "summary", "text": "When an application tells libcurl it wants to allow HTTP/2 server push, and the amount of received headers for the push surpasses the maximum allowed limit (1000), libcurl aborts the server push. When aborting, libcurl inadvertently does not free all the previously allocated headers and instead leaks the memory. Further, this error condition fails silently and is therefore not easily detected by an application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-2398" }, { "cve": "CVE-2024-2466", "cwe": { "id": "CWE-297", "name": "Improper Validation of Certificate with Host Mismatch" }, "notes": [ { "category": "summary", "text": "libcurl did not check the server certificate of TLS connections done to a host specified as an IP address, when built to use mbedTLS. libcurl would wrongly avoid using the set hostname function when the specified hostname was given as an IP address, therefore completely skipping the certificate check. This affects all uses of TLS protocols (HTTPS, FTPS, IMAPS, POPS3, SMTPS, etc).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-2466" }, { "cve": "CVE-2024-24795", "cwe": { "id": "CWE-113", "name": "Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Request/Response Splitting\u0027)" }, "notes": [ { "category": "summary", "text": "HTTP Response splitting in multiple modules in Apache HTTP Server allows an attacker that can inject malicious response headers into backend applications to cause an HTTP desynchronization attack. Users are recommended to upgrade to version 2.4.59, which fixes this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-24795" }, { "cve": "CVE-2024-27316", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "HTTP/2 incoming headers exceeding the limit are temporarily buffered in nghttp2 in order to generate an informative HTTP 413 response. If a client does not stop sending headers, this leads to memory exhaustion.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-27316" }, { "cve": "CVE-2024-47808", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system.\r\nThis could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109974917/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-47808" } ] }
wid-sec-w-2024-1104
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "WinCC (Windows Control Center) ist ein PC-basiertes Prozessvisualisierungssystem von Siemens. \r\nTIA-Portal ist ein Automatisierungsframework f\u00fcr Steuerungen und andere Automatisierungsger\u00e4te der SIMATIC-Serie.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein lokaler Angreifer kann eine Schwachstelle in Siemens SIMATIC WinCC und Siemens TIA Portal ausnutzen, um einen Denial of Service Angriff durchzuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Windows", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2024-1104 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2024/wid-sec-w-2024-1104.json" }, { "category": "self", "summary": "WID-SEC-2024-1104 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2024-1104" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT vom 2024-05-13", "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" } ], "source_lang": "en-US", "title": "Siemens SIMATIC WinCC und TIA Portal: Schwachstelle erm\u00f6glicht Denial of Service", "tracking": { "current_release_date": "2024-05-13T22:00:00.000+00:00", "generator": { "date": "2024-08-15T18:08:50.555+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2024-1104", "initial_release_date": "2024-05-13T22:00:00.000+00:00", "revision_history": [ { "date": "2024-05-13T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SIMATIC WinCC", "product": { "name": "Siemens SIMATIC WinCC", "product_id": "T034733", "product_identification_helper": { "cpe": "cpe:/a:siemens:simatic_wincc:-" } } }, { "category": "product_version_range", "name": "\u003c19 Update 2", "product": { "name": "Siemens TIA Portal \u003c19 Update 2", "product_id": "T034734" } } ], "category": "product_name", "name": "SIMATIC WinCC" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46280", "notes": [ { "category": "description", "text": "Es besteht eine Schwachstelle in Siemens SIMATIC WinCC und Siemens TIA Portal. Dieser Fehler besteht aufgrund eines \u201eOut of Bounds\u201c-Leseproblems, das zu einem Absturz des Blue Screen of Death (BSOD) f\u00fchrt. Ein lokaler Angreifer kann diese Schwachstelle ausnutzen, um einen Denial-of-Service-Zustand zu verursachen." } ], "product_status": { "known_affected": [ "T034733" ] }, "release_date": "2024-05-13T22:00:00.000+00:00", "title": "CVE-2023-46280" } ] }
gsd-2023-46280
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2023-46280", "id": "GSD-2023-46280" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-46280" ], "id": "GSD-2023-46280", "modified": "2023-12-13T01:20:53.133480Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2023-46280", "STATE": "RESERVED" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." } ] } } } }
ghsa-g3gv-9xvr-p3r6
Vulnerability from github
8.2 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H
A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SINAMICS Startdrive (All versions < V19 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.
{ "affected": [], "aliases": [ "CVE-2023-46280" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-05-14T16:15:40Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SINAMICS Startdrive (All versions \u003c V19 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.", "id": "GHSA-g3gv-9xvr-p3r6", "modified": "2024-11-18T16:26:41Z", "published": "2024-05-14T18:30:58Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-46280" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H", "type": "CVSS_V3" }, { "score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "type": "CVSS_V4" } ] }
var-202405-0210
Vulnerability from variot
A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0210", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "security configuration tool", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic automation tool", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic net pc software", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v3.17" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v17" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v15.1" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7v9.1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v17" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v19" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "totally integrated automation portal update", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v19\u003cv192" }, { "model": "tia portal cloud connector", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.0" }, { "model": "sinumerik plc programming tool", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinumerik one virtual", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v6.23" }, { "model": "sinamics startdrive sp1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v19" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7.5" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7.4" }, { "model": "simatic wincc unified pc runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "simatic wincc oa p010", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v3.19\u003cv3.19" }, { "model": "simatic wincc oa p025", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v3.18\u003cv3.18" }, { "model": "simatic step", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7v5" }, { "model": "simatic route control", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v9.1" }, { "model": "simatic pdm", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v9.2" }, { "model": "simatic batch", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v9.1" }, { "model": "s7-pct", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ] }, "cve": "CVE-2023-46280", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 4.6, "confidentialityImpact": "NONE", "exploitabilityScore": 3.1, "id": "CNVD-2024-24524", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.0, "id": "CVE-2023-46280", "impactScore": 4.0, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-46280", "trust": 1.0, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-24524", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server", "sources": [ { "db": "NVD", "id": "CVE-2023-46280" }, { "db": "CNVD", "id": "CNVD-2024-24524" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-962515", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2023-46280", "trust": 1.6 }, { "db": "SIEMENS", "id": "SSA-784301", "trust": 1.0 }, { "db": "SIEMENS", "id": "SSA-331112", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-24524", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "id": "VAR-202405-0210", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ], "trust": 1.2706952166666667 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ] }, "last_update_date": "2024-11-13T19:49:07.316000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products Out-of-Bounds Read Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/547666" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-46280" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-30T00:00:00", "db": "CNVD", "id": "CNVD-2024-24524" }, { "date": "2024-05-14T16:15:40.800000", "db": "NVD", "id": "CVE-2023-46280" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2024-24524" }, { "date": "2024-11-12T13:15:05.960000", "db": "NVD", "id": "CVE-2023-46280" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products Out-of-Bounds Read Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.