ICSA-22-088-03

Vulnerability from csaf_cisa - Published: 2022-03-29 00:00 - Updated: 2022-03-29 00:00
Summary
Hitachi Energy LinkOne WebView

Notes

CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to modify a victim 's system files or information, disclose application full path, disclose sensitive information to an unauthorized actor, and launch a common web attack.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Switzerland
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities have a high attack complexity.

{
  "document": {
    "acknowledgments": [
      {
        "organization": "Compa\u00f1\u00eda Minera Do\u00f1a In\u00e9s de Collahuasi SCM",
        "summary": "reporting these vulnerabilities to Hitachi Energy"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities could allow an attacker to modify a victim \u0027s system files or information, disclose application full path, disclose sensitive information to an unauthorized actor, and launch a common web attack.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Multiple Sectors",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Switzerland",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
        "title": "Recommended Practices"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities have a high attack complexity.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-088-03 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-088-03.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-088-03 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-088-03"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      }
    ],
    "title": "Hitachi Energy LinkOne WebView",
    "tracking": {
      "current_release_date": "2022-03-29T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-22-088-03",
      "initial_release_date": "2022-03-29T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2022-03-29T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-22-088-03 Hitachi Energy LinkOne WebView"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.25",
                "product": {
                  "name": "LinkOne WebView: v3.25",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "LinkOne WebView"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.23",
                "product": {
                  "name": "LinkOne WebView: v3.23",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "LinkOne WebView"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.22",
                "product": {
                  "name": "LinkOne WebView: v3.22",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "LinkOne WebView"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.24",
                "product": {
                  "name": "LinkOne WebView: v3.24",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "LinkOne WebView"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.26",
                "product": {
                  "name": "LinkOne WebView: v3.26",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "LinkOne WebView"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.2",
                "product": {
                  "name": "LinkOne WebView: v3.20",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "LinkOne WebView"
          }
        ],
        "category": "vendor",
        "name": "Hitachi Energy"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-40337",
      "cwe": {
        "id": "CWE-79",
        "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Multiple stored XSS vulnerabilities exist in the LinkOne application, allowing multiple web attacks and the theft of sensitive information.CVE-2021-40337 has been assigned to these vulnerabilities. A CVSS v3 base score of 4.2 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-40337"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Hitachi Energy recommends applying the available security patch or updating LinkOne to v3.27. Contact Hitachi Energy for more information on applying the security patch or updating LinkOne to v3.27",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us"
        },
        {
          "category": "mitigation",
          "details": "Recommended security practices and firewall configurations can help protect the application from attacks that originate from outside the network. Such practices include physically protecting the application from direct access by unauthorized personnel, having no direct connections to the Internet. For the end-user of the application, it is recommended to use the latest browser when accessing the LinkOne application.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information, review Hitachi Energy\u0027s security advisory 8DBD000079",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000079\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "category": "mitigation",
          "details": "Additional recommendation is to follow the hardening guidelines published by The Center for Internet Security (CIS) to protect the host Operating System on which the LinkOne is hosted.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.cisecurity.org/about-us/"
        },
        {
          "category": "mitigation",
          "details": "For additional information and support please contact your product provider or Hitachi Energy service.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2021-40338",
      "cwe": {
        "id": "CWE-209",
        "name": "Generation of Error Message Containing Sensitive Information"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When an error happens during the query operation in the application due to a misconfiguration in the web server configuration file, debug mode in LinkOne application is activated and shows the full path of the directory.CVE-2021-40338 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-40338"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Hitachi Energy recommends applying the available security patch or updating LinkOne to v3.27. Contact Hitachi Energy for more information on applying the security patch or updating LinkOne to v3.27",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us"
        },
        {
          "category": "mitigation",
          "details": "Recommended security practices and firewall configurations can help protect the application from attacks that originate from outside the network. Such practices include physically protecting the application from direct access by unauthorized personnel, having no direct connections to the Internet. For the end-user of the application, it is recommended to use the latest browser when accessing the LinkOne application.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information, review Hitachi Energy\u0027s security advisory 8DBD000079",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000079\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "category": "mitigation",
          "details": "Additional recommendation is to follow the hardening guidelines published by The Center for Internet Security (CIS) to protect the host Operating System on which the LinkOne is hosted.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.cisecurity.org/about-us/"
        },
        {
          "category": "mitigation",
          "details": "For additional information and support please contact your product provider or Hitachi Energy service.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2021-40339",
      "cwe": {
        "id": "CWE-693",
        "name": "Protection Mechanism Failure"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The LinkOne application is lacking HTTP Headers, allowing an attacker to retrieve sensitive information.CVE-2021-40339 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-40339"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Hitachi Energy recommends applying the available security patch or updating LinkOne to v3.27. Contact Hitachi Energy for more information on applying the security patch or updating LinkOne to v3.27",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us"
        },
        {
          "category": "mitigation",
          "details": "Recommended security practices and firewall configurations can help protect the application from attacks that originate from outside the network. Such practices include physically protecting the application from direct access by unauthorized personnel, having no direct connections to the Internet. For the end-user of the application, it is recommended to use the latest browser when accessing the LinkOne application.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information, review Hitachi Energy\u0027s security advisory 8DBD000079",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000079\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "category": "mitigation",
          "details": "Additional recommendation is to follow the hardening guidelines published by The Center for Internet Security (CIS) to protect the host Operating System on which the LinkOne is hosted.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.cisecurity.org/about-us/"
        },
        {
          "category": "mitigation",
          "details": "For additional information and support please contact your product provider or Hitachi Energy service.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2021-40340",
      "cwe": {
        "id": "CWE-200",
        "name": "Exposure of Sensitive Information to an Unauthorized Actor"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Misconfiguration in the ASP server causes server and ASP.net information to be shown. An attacker can use this information as a reconnaissance for further exploitation.CVE-2021-40340 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-40340"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Hitachi Energy recommends applying the available security patch or updating LinkOne to v3.27. Contact Hitachi Energy for more information on applying the security patch or updating LinkOne to v3.27",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us"
        },
        {
          "category": "mitigation",
          "details": "Recommended security practices and firewall configurations can help protect the application from attacks that originate from outside the network. Such practices include physically protecting the application from direct access by unauthorized personnel, having no direct connections to the Internet. For the end-user of the application, it is recommended to use the latest browser when accessing the LinkOne application.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information, review Hitachi Energy\u0027s security advisory 8DBD000079",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000079\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "category": "mitigation",
          "details": "Additional recommendation is to follow the hardening guidelines published by The Center for Internet Security (CIS) to protect the host Operating System on which the LinkOne is hosted.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.cisecurity.org/about-us/"
        },
        {
          "category": "mitigation",
          "details": "For additional information and support please contact your product provider or Hitachi Energy service.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ],
          "url": "https://www.hitachienergy.com/contact-us/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006"
          ]
        }
      ]
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…