Search criteria
105 vulnerabilities by Hitachi Energy
CVE-2026-8479 (GCVE-0-2026-8479)
Vulnerability from cvelistv5 – Published: 2026-05-26 11:54 – Updated: 2026-05-26 14:49
VLAI
Summary
IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.
Severity
CWE
- CWE-476 - NULL pointer dereference
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 series CMU firmware |
Affected:
12.7.1 , ≤ 12.7.7
(custom)
Affected: 13.5.1 , ≤ 13.5.4 (custom) Affected: 13.6.1 , ≤ 13.6.3 (custom) Affected: 13.7.1 , ≤ 13.7.8 (custom) Affected: 13.8.1 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8479",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T14:30:56.474198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T14:42:00.978Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series CMU firmware",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "12.7.7",
"status": "affected",
"version": "12.7.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.5.4",
"status": "affected",
"version": "13.5.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.6.3",
"status": "affected",
"version": "13.6.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.7.8",
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.8.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable\nfor a NULL pointer dereferencing, if a specially crafted\nsequence of messages is sent for a certain time, causing\nDenial of Service impact.\nProduct is only affected if IEC 60870-5-104 functionality in\nbidirectional mode (BCI) is configured.\n\n\u003cbr\u003e"
}
],
"value": "IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable\nfor a NULL pointer dereferencing, if a specially crafted\nsequence of messages is sent for a certain time, causing\nDenial of Service impact.\nProduct is only affected if IEC 60870-5-104 functionality in\nbidirectional mode (BCI) is configured."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL pointer dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T14:49:40.036Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000252\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2026-8479",
"datePublished": "2026-05-26T11:54:09.962Z",
"dateReserved": "2026-05-13T13:42:53.588Z",
"dateUpdated": "2026-05-26T14:49:40.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-7310 (GCVE-0-2026-7310)
Vulnerability from cvelistv5 – Published: 2026-05-26 11:43 – Updated: 2026-05-26 14:42
VLAI
Summary
A heap-based buffer overflow vulnerability exists in XML
parser functionality in the HiDraw. An authenticated
malicious user with local access can exploit this
vulnerability using a specially crafted XML file which may
lead to memory corruption and potential arbitrary code
execution. Successful exploitation could result in
application crashes (denial of service) and compromise the
confidentiality and integrity of the affected system.
Severity
CWE
- CWE-122 - Heap-based buffer overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MACH HiDraw |
Affected:
9.0 , < 9.22
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-7310",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T14:31:07.539083Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T14:42:15.647Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MACH HiDraw",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThan": "9.22",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A heap-based buffer overflow vulnerability exists in XML\nparser functionality in the HiDraw. An authenticated\nmalicious user with local access can exploit this\nvulnerability using a specially crafted XML file which may\nlead to memory corruption and potential arbitrary code\nexecution. Successful exploitation could result in\napplication crashes (denial of service) and compromise the\nconfidentiality and integrity of the affected system.\u0026nbsp;\u0026nbsp;"
}
],
"value": "A heap-based buffer overflow vulnerability exists in XML\nparser functionality in the HiDraw. An authenticated\nmalicious user with local access can exploit this\nvulnerability using a specially crafted XML file which may\nlead to memory corruption and potential arbitrary code\nexecution. Successful exploitation could result in\napplication crashes (denial of service) and compromise the\nconfidentiality and integrity of the affected system."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based buffer overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T11:43:41.155Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000248\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2026-7310",
"datePublished": "2026-05-26T11:43:41.155Z",
"dateReserved": "2026-04-28T12:37:08.600Z",
"dateUpdated": "2026-05-26T14:42:15.647Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2460 (GCVE-0-2026-2460)
Vulnerability from cvelistv5 – Published: 2026-02-24 13:24 – Updated: 2026-02-28 02:23
VLAI
Summary
A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so.
Severity
CWE
- CWE-267 - Privilege Defined with Unsafe Actions
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Relion REB500 |
Affected:
8.0.0.0 , ≤ 8.3.3.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2460",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-28T02:23:01.866036Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-28T02:23:18.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Relion REB500",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "8.3.3.0",
"status": "affected",
"version": "8.0.0.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so.\u003cbr\u003e"
}
],
"value": "A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-267",
"description": "CWE-267 Privilege Defined with Unsafe Actions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T13:43:35.340Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000217\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2026-2460",
"datePublished": "2026-02-24T13:24:34.836Z",
"dateReserved": "2026-02-13T11:08:27.300Z",
"dateUpdated": "2026-02-28T02:23:18.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2459 (GCVE-0-2026-2459)
Vulnerability from cvelistv5 – Published: 2026-02-24 13:21 – Updated: 2026-02-28 02:22
VLAI
Summary
A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so.
Severity
CWE
- CWE-267 - Privilege Defined with Unsafe Actions
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Relion REB500 |
Affected:
8.0.0.0 , ≤ 8.3.3.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2459",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-28T02:21:26.119358Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-28T02:22:21.519Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Relion REB500",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "8.3.3.0",
"status": "affected",
"version": "8.0.0.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so.\u003cbr\u003e"
}
],
"value": "A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-267",
"description": "CWE-267 Privilege Defined with Unsafe Actions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T13:42:34.978Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000217\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2026-2459",
"datePublished": "2026-02-24T13:21:42.470Z",
"dateReserved": "2026-02-13T11:08:24.044Z",
"dateUpdated": "2026-02-28T02:22:21.519Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1773 (GCVE-0-2026-1773)
Vulnerability from cvelistv5 – Published: 2026-02-24 13:13 – Updated: 2026-05-27 14:50
VLAI
Summary
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.
Severity
CWE
- CWE-184 - Incomplete List of Disallowed Inputs
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 series CMU firmware |
Affected:
12.7.1 , ≤ 12.7.7
(custom)
Affected: 13.5.1 , ≤ 13.5.4 (custom) Affected: 13.6.1 , ≤ 13.6.2 (custom) Affected: 13.7.1 , ≤ 13.7.7 (custom) Affected: 13.8.1 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1773",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-28T02:19:44.432868Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T14:50:01.447Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series CMU firmware",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "12.7.7",
"status": "affected",
"version": "12.7.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.5.4",
"status": "affected",
"version": "13.5.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.6.2",
"status": "affected",
"version": "13.6.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.7.7",
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.8.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame.\u0026nbsp;Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.\u003cbr\u003e"
}
],
"value": "IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame.\u00a0Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation."
}
],
"impacts": [
{
"capecId": "CAPEC-278",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-278 Web Services Protocol Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-184",
"description": "CWE-184 Incomplete List of Disallowed Inputs",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T14:53:41.970Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000237\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2026-1773",
"datePublished": "2026-02-24T13:13:17.990Z",
"dateReserved": "2026-02-02T16:28:59.394Z",
"dateUpdated": "2026-05-27T14:50:01.447Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1772 (GCVE-0-2026-1772)
Vulnerability from cvelistv5 – Published: 2026-02-24 13:03 – Updated: 2026-02-28 02:19
VLAI
Summary
RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.
Severity
CWE
- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 series CMU firmware |
Affected:
12.7.1 , ≤ 12.7.7
(custom)
Affected: 13.5.1 , ≤ 13.5.4 (custom) Affected: 13.6.1 , ≤ 13.6.2 (custom) Affected: 13.7.1 , ≤ 13.7.7 (custom) Affected: 13.8.1 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1772",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-28T02:18:35.605096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-28T02:19:01.092Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series CMU firmware",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "12.7.7",
"status": "affected",
"version": "12.7.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.5.4",
"status": "affected",
"version": "13.5.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.6.2",
"status": "affected",
"version": "13.6.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.7.7",
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.8.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.\u003cbr\u003e"
}
],
"value": "RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges."
}
],
"impacts": [
{
"capecId": "CAPEC-503",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-503 WebView Exposure"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280 Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T13:38:30.521Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000237\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2026-1772",
"datePublished": "2026-02-24T13:03:23.592Z",
"dateReserved": "2026-02-02T16:28:53.742Z",
"dateUpdated": "2026-02-28T02:19:01.092Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-7740 (GCVE-0-2025-7740)
Vulnerability from cvelistv5 – Published: 2026-01-28 09:02 – Updated: 2026-01-28 16:32
VLAI
Title
Use of default credentials vulnerability in Hitachi Energy SuprOS product
Summary
Default credentials vulnerability exists in SuprOS
product. If exploited, this could allow an authenticated
local attacker to use an admin account created during
product deployment.
Severity
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | SuprOS |
Affected:
9.0.0 , ≤ 9.2.2.0
(custom)
|
Date Public
2026-01-27 13:26
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7740",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-28T16:32:14.188387Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-28T16:32:25.192Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SuprOS",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "9.2.2.0",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2026-01-27T13:26:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Default credentials vulnerability exists in SuprOS\nproduct. If exploited, this could allow an authenticated\nlocal attacker to use an admin account created during\nproduct deployment.\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Default credentials vulnerability exists in SuprOS\nproduct. If exploited, this could allow an authenticated\nlocal attacker to use an admin account created during\nproduct deployment."
}
],
"impacts": [
{
"capecId": "CAPEC-70",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-70 Try Common or Default Usernames and Passwords"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392 Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-28T09:02:21.430Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000223\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of default credentials vulnerability in Hitachi Energy SuprOS product",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-7740",
"datePublished": "2026-01-28T09:02:21.430Z",
"dateReserved": "2025-07-17T06:26:51.973Z",
"dateUpdated": "2026-01-28T16:32:25.192Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-1038 (GCVE-0-2025-1038)
Vulnerability from cvelistv5 – Published: 2025-10-28 12:17 – Updated: 2025-10-28 13:11
VLAI
Summary
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.
Severity
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TropOS 4th Gen |
Affected:
8.7.0.0 , < 8.9.6.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1038",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:10:58.401351Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:11:10.628Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TropOS 4th Gen",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThan": "8.9.6.0",
"status": "affected",
"version": "8.7.0.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachi_energy:tropos_4th_gen:*:*:*:*:*:*:*:*",
"versionEndExcluding": "8.9.6.0",
"versionStartIncluding": "8.7.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \u201cDiagnostics Tools\u201d page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.\u003cbr\u003e"
}
],
"value": "The \u201cDiagnostics Tools\u201d page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T12:17:23.182Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000214\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-1038",
"datePublished": "2025-10-28T12:17:23.182Z",
"dateReserved": "2025-02-04T16:13:20.773Z",
"dateUpdated": "2025-10-28T13:11:10.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1037 (GCVE-0-2025-1037)
Vulnerability from cvelistv5 – Published: 2025-10-28 12:16 – Updated: 2025-10-28 13:13
VLAI
Summary
By making minor configuration changes to the TropOS 4th Gen device, an authenticated user with the ability to run user level shell commands can enable access via secure shell (SSH) to an unrestricted root shell. This is possible through abuse of a particular set of scripts and executables that allow for certain commands to be run as root from an unprivileged context.
Severity
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TropOS 4th Gen |
Affected:
8.7.0.0 , ≤ 8.9.6.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1037",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:12:51.605829Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:13:02.115Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TropOS 4th Gen",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "8.9.6.0",
"status": "affected",
"version": "8.7.0.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachi_energy:tropos_4th_gen:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.9.6.0",
"versionStartIncluding": "8.7.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "By making minor configuration changes to the TropOS 4th Gen device, an authenticated user with the ability to run user level shell commands can enable access via secure shell (SSH) to an unrestricted root shell. This is possible through abuse of a particular set of scripts and executables that allow for certain commands to be run as root from an unprivileged context.\u003cbr\u003e"
}
],
"value": "By making minor configuration changes to the TropOS 4th Gen device, an authenticated user with the ability to run user level shell commands can enable access via secure shell (SSH) to an unrestricted root shell. This is possible through abuse of a particular set of scripts and executables that allow for certain commands to be run as root from an unprivileged context."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T12:16:36.060Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000214\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-1037",
"datePublished": "2025-10-28T12:16:36.060Z",
"dateReserved": "2025-02-04T16:13:19.059Z",
"dateUpdated": "2025-10-28T13:13:02.115Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1036 (GCVE-0-2025-1036)
Vulnerability from cvelistv5 – Published: 2025-10-28 12:15 – Updated: 2025-10-28 13:14
VLAI
Summary
Command injection vulnerability exists in the “Logging” page of the web-based configuration utility. An authenticated user with low privileged network access for the configuration utility can execute arbitrary commands on the underlying OS to obtain root SSH access to the TropOS 4th Gen device.
Severity
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TropOS 4th Gen |
Affected:
8.7.0.0 , ≤ 8.9.6.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1036",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:14:04.115323Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:14:18.210Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TropOS 4th Gen",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "8.9.6.0",
"status": "affected",
"version": "8.7.0.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachi_energy:tropos_4th_gen:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.9.6.0",
"versionStartIncluding": "8.7.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Command injection vulnerability exists in the \u201cLogging\u201d page of the web-based configuration utility. An authenticated user with low privileged network access for the configuration utility can execute arbitrary commands on the underlying OS to obtain root SSH access to the TropOS 4th Gen device.\u003cbr\u003e"
}
],
"value": "Command injection vulnerability exists in the \u201cLogging\u201d page of the web-based configuration utility. An authenticated user with low privileged network access for the configuration utility can execute arbitrary commands on the underlying OS to obtain root SSH access to the TropOS 4th Gen device."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T12:15:29.573Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000214\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-1036",
"datePublished": "2025-10-28T12:15:29.573Z",
"dateReserved": "2025-02-04T16:13:15.117Z",
"dateUpdated": "2025-10-28T13:14:18.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10217 (GCVE-0-2025-10217)
Vulnerability from cvelistv5 – Published: 2025-09-30 12:10 – Updated: 2025-10-28 10:28
VLAI
Summary
A vulnerability exists in Asset Suite for an authenticated user to manipulate the content of performance related log data or to inject crafted data in logfile for potentially carrying out further malicious attacks. Performance logging is typically enabled for troubleshooting purposes while resolving application performance related issues.
Severity
CWE
- CWE-117 - Improper Output Neutralization for Logs
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Asset Suite |
Affected:
9.0 , ≤ 9.8
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10217",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-30T13:04:01.987539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-30T13:04:07.996Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Asset Suite",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "9.8",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachi_energy:asset_suite:*:*:*:*:*:*:*:*",
"versionEndIncluding": "9.8",
"versionStartIncluding": "9.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in Asset Suite for an authenticated user to manipulate the content of performance related log data or to inject crafted data in logfile for potentially carrying out further malicious attacks. Performance logging is typically enabled for troubleshooting purposes while resolving application performance related issues.\u003cbr\u003e"
}
],
"value": "A vulnerability exists in Asset Suite for an authenticated user to manipulate the content of performance related log data or to inject crafted data in logfile for potentially carrying out further malicious attacks. Performance logging is typically enabled for troubleshooting purposes while resolving application performance related issues."
}
],
"impacts": [
{
"capecId": "CAPEC-93",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-93 Log Injection-Tampering-Forging"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-117",
"description": "CWE-117 Improper Output Neutralization for Logs",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T10:28:45.480Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000226\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-10217",
"datePublished": "2025-09-30T12:10:23.803Z",
"dateReserved": "2025-09-10T11:07:55.536Z",
"dateUpdated": "2025-10-28T10:28:45.480Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-39205 (GCVE-0-2025-39205)
Vulnerability from cvelistv5 – Published: 2025-06-24 12:13 – Updated: 2025-10-01 14:58
VLAI
Summary
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.
Severity
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MicroSCADA X SYS600 |
Affected:
10.3 , ≤ 10.6
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-39205",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:22:05.197451Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:09.430Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MicroSCADA X SYS600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "10.6",
"status": "affected",
"version": "10.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation."
}
],
"value": "A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation."
}
],
"impacts": [
{
"capecId": "CAPEC-475",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-475 Signature Spoofing by Improper Validation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-01T14:58:20.730Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000218\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-39205",
"datePublished": "2025-06-24T12:13:20.791Z",
"dateReserved": "2025-04-16T05:26:03.424Z",
"dateUpdated": "2025-10-01T14:58:20.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-39204 (GCVE-0-2025-39204)
Vulnerability from cvelistv5 – Published: 2025-06-24 12:01 – Updated: 2025-06-25 12:42
VLAI
Summary
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.
Severity
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MicroSCADA X SYS600 |
Affected:
10.0 , ≤ 10.6
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-39204",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:22:07.253183Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:14.761Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MicroSCADA X SYS600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "10.6",
"status": "affected",
"version": "10.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user."
}
],
"value": "A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user."
}
],
"impacts": [
{
"capecId": "CAPEC-54",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-54 Query System for Information"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:46:35.883Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000218\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-39204",
"datePublished": "2025-06-24T12:01:09.855Z",
"dateReserved": "2025-04-16T05:26:03.424Z",
"dateUpdated": "2025-06-25T12:42:14.761Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-39203 (GCVE-0-2025-39203)
Vulnerability from cvelistv5 – Published: 2025-06-24 11:57 – Updated: 2025-10-07 10:00
VLAI
Summary
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.
Severity
CWE
- CWE-354 - Improper Validation of Integrity Check Value
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MicroSCADA X SYS600 |
Affected:
10.5 , ≤ 10.6
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-39203",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:22:09.329141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:19.734Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MicroSCADA X SYS600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "10.6",
"status": "affected",
"version": "10.5",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop."
}
],
"value": "A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop."
}
],
"impacts": [
{
"capecId": "CAPEC-595",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-595 Connection Reset"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-354",
"description": "CWE-354 Improper Validation of Integrity Check Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T10:00:29.745Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000218\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-39203",
"datePublished": "2025-06-24T11:57:04.229Z",
"dateReserved": "2025-04-16T05:26:03.424Z",
"dateUpdated": "2025-10-07T10:00:29.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-39202 (GCVE-0-2025-39202)
Vulnerability from cvelistv5 – Published: 2025-06-24 11:51 – Updated: 2025-06-25 12:42
VLAI
Summary
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.
Severity
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MicroSCADA X SYS600 |
Affected:
10.0 , ≤ 10.6
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-39202",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:23:46.957075Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:25.143Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MicroSCADA X SYS600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "10.6",
"status": "affected",
"version": "10.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption."
}
],
"value": "A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption."
}
],
"impacts": [
{
"capecId": "CAPEC-131",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-131 Resource Leak Exposure"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:13:37.460Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000218\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-39202",
"datePublished": "2025-06-24T11:51:58.576Z",
"dateReserved": "2025-04-16T05:26:03.424Z",
"dateUpdated": "2025-06-25T12:42:25.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-39201 (GCVE-0-2025-39201)
Vulnerability from cvelistv5 – Published: 2025-06-24 11:46 – Updated: 2025-06-25 12:42
VLAI
Summary
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.
Severity
6.1 (Medium)
CWE
- CWE-276 - Incorrect Default Permissions
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MicroSCADA X SYS600 |
Affected:
10.0 , ≤ 10.6
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-39201",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:22:11.449617Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:30.293Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MicroSCADA X SYS600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "10.6",
"status": "affected",
"version": "10.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service."
}
],
"value": "A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service."
}
],
"impacts": [
{
"capecId": "CAPEC-75",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-75 Manipulating Writeable Configuration Files"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:34:24.888Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000218\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-39201",
"datePublished": "2025-06-24T11:46:11.548Z",
"dateReserved": "2025-04-16T05:26:03.424Z",
"dateUpdated": "2025-06-25T12:42:30.293Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2403 (GCVE-0-2025-2403)
Vulnerability from cvelistv5 – Published: 2025-06-24 11:33 – Updated: 2025-06-25 12:42
VLAI
Summary
A denial-of-service vulnerability due to improper prioritization of network traffic over protection mechanism exists in Relion 670/650 and SAM600-IO series device that if exploited could potentially cause critical functions like LDCM (Line Distance Communication Module) to malfunction.
Severity
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Relion 670/650 and SAM600-IO |
Affected:
2.2.6.0 , ≤ 2.2.6.2
(custom)
Affected: 2.2.5.6 (custom) Affected: 2.2.4.4 (custom) Affected: 2.2.3.7 (custom) Affected: 2.2.2.6 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2403",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:24:33.228316Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:35.650Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Relion 670/650 and SAM600-IO",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "2.2.6.2",
"status": "affected",
"version": "2.2.6.0",
"versionType": "custom"
},
{
"status": "affected",
"version": "2.2.5.6",
"versionType": "custom"
},
{
"status": "affected",
"version": "2.2.4.4",
"versionType": "custom"
},
{
"status": "affected",
"version": "2.2.3.7",
"versionType": "custom"
},
{
"status": "affected",
"version": "2.2.2.6",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A denial-of-service vulnerability due to improper prioritization of network traffic over protection mechanism exists in Relion 670/650 and SAM600-IO series device that if exploited could potentially cause critical functions like LDCM (Line Distance Communication Module) to malfunction.\u003cbr\u003e"
}
],
"value": "A denial-of-service vulnerability due to improper prioritization of network traffic over protection mechanism exists in Relion 670/650 and SAM600-IO series device that if exploited could potentially cause critical functions like LDCM (Line Distance Communication Module) to malfunction."
}
],
"impacts": [
{
"capecId": "CAPEC-125",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-125 Flooding"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:24:16.087Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000216\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-2403",
"datePublished": "2025-06-24T11:33:10.236Z",
"dateReserved": "2025-03-17T10:36:28.911Z",
"dateUpdated": "2025-06-25T12:42:35.650Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1718 (GCVE-0-2025-1718)
Vulnerability from cvelistv5 – Published: 2025-06-24 11:24 – Updated: 2025-06-25 12:42
VLAI
Summary
An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management.
Severity
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Relion 670/650 and SAM600-IO |
Affected:
2.2.6.0 , ≤ 2.2.6.3
(custom)
Affected: 2.2.5.0 , ≤ 2.2.5.7 (custom) Affected: 2.2.4.0 , ≤ 2.2.4.5 (custom) Affected: 2.2.3.0 , ≤ 2.2.3.7 (custom) Affected: 2.2.2.0 , ≤ 2.2.2.6 (custom) Affected: 2.2.1.0 , ≤ 2.2.1.8 (custom) Affected: 2.2.0.0 , ≤ 2.2.0.13 (custom) Affected: 2.1.0 , < 2.1.* (custom) Affected: 2.0.0 , < 2.0.* (custom) Affected: 1 , < 1.* (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1718",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:22:13.533561Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:42:41.525Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Relion 670/650 and SAM600-IO",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "2.2.6.3",
"status": "affected",
"version": "2.2.6.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "2.2.5.7",
"status": "affected",
"version": "2.2.5.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "2.2.4.5",
"status": "affected",
"version": "2.2.4.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "2.2.3.7",
"status": "affected",
"version": "2.2.3.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "2.2.2.6",
"status": "affected",
"version": "2.2.2.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "2.2.1.8",
"status": "affected",
"version": "2.2.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "2.2.0.13",
"status": "affected",
"version": "2.2.0.0",
"versionType": "custom"
},
{
"lessThan": "2.1.*",
"status": "affected",
"version": "2.1.0",
"versionType": "custom"
},
{
"lessThan": "2.0.*",
"status": "affected",
"version": "2.0.0",
"versionType": "custom"
},
{
"lessThan": "1.*",
"status": "affected",
"version": "1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management.\u003cbr\u003e"
}
],
"value": "An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management."
}
],
"impacts": [
{
"capecId": "CAPEC-679",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-679 Exploitation of Improperly Configured or Implemented Memory Protections"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:20:09.558Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000174\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-1718",
"datePublished": "2025-06-24T11:24:17.579Z",
"dateReserved": "2025-02-26T16:05:27.638Z",
"dateUpdated": "2025-06-25T12:42:41.525Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2500 (GCVE-0-2025-2500)
Vulnerability from cvelistv5 – Published: 2025-05-30 12:29 – Updated: 2025-05-30 13:22
VLAI
Summary
A vulnerability exists in the SOAP Web services of the Asset
Suite versions listed below. If successfully exploited, an attacker
could gain unauthorized access to the product and the time window of a possible password attack could be expanded.
Severity
7.4 (High)
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Asset Suite |
Affected:
9.6.4.4
Affected: 9.7 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2500",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-30T13:22:10.779733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-30T13:22:19.268Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Asset Suite",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "9.6.4.4"
},
{
"status": "affected",
"version": "9.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the SOAP Web services of the Asset \nSuite versions listed below. If successfully exploited, an attacker \ncould gain unauthorized access to the product and the time window of a possible password attack could be expanded."
}
],
"value": "A vulnerability exists in the SOAP Web services of the Asset \nSuite versions listed below. If successfully exploited, an attacker \ncould gain unauthorized access to the product and the time window of a possible password attack could be expanded."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-30T12:29:21.370Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000212\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-2500",
"datePublished": "2025-05-30T12:29:21.370Z",
"dateReserved": "2025-03-18T14:54:10.957Z",
"dateUpdated": "2025-05-30T13:22:19.268Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1484 (GCVE-0-2025-1484)
Vulnerability from cvelistv5 – Published: 2025-05-30 12:26 – Updated: 2025-05-30 13:22
VLAI
Summary
A vulnerability exists in the media upload component of the Asset
Suite versions listed below. If successfully exploited an attacker
could impact the confidentiality or integrity of the system. An attacker can use this vulnerability to construct a request that will
cause JavaScript code supplied by the attacker to execute within
the user’s browser in the context of that user’s session with the
application.
Severity
6.5 (Medium)
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | Asset Suite |
Affected:
9.6.4.4
Unaffected: 9.6.4.5 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1484",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-30T13:22:35.804566Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-30T13:22:41.411Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Asset Suite",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "9.6.4.4"
},
{
"status": "unaffected",
"version": "9.6.4.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the media upload component of the Asset \nSuite versions listed below. If successfully exploited an attacker \ncould impact the confidentiality or integrity of the system. An attacker can use this vulnerability to construct a request that will \ncause JavaScript code supplied by the attacker to execute within \nthe user\u2019s browser in the context of that user\u2019s session with the \napplication."
}
],
"value": "A vulnerability exists in the media upload component of the Asset \nSuite versions listed below. If successfully exploited an attacker \ncould impact the confidentiality or integrity of the system. An attacker can use this vulnerability to construct a request that will \ncause JavaScript code supplied by the attacker to execute within \nthe user\u2019s browser in the context of that user\u2019s session with the \napplication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:H/SI:H/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-184",
"description": "CWE-184",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-30T12:26:42.536Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000212\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-1484",
"datePublished": "2025-05-30T12:26:42.536Z",
"dateReserved": "2025-02-19T21:19:18.947Z",
"dateUpdated": "2025-05-30T13:22:41.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27631 (GCVE-0-2025-27631)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:46 – Updated: 2025-03-25 13:07
VLAI
Summary
The TRMTracker web application is vulnerable to LDAP injection attack potentially allowing an attacker to inject code into a query and execute remote commands that can read and update data on the website.
Severity
6.5 (Medium)
CWE
- CWE-90 - Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TRMTracker |
Affected:
6.2 , ≤ 6.2.04
(custom)
Affected: 6.3 , ≤ 6.3.01 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27631",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:07:38.216323Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:07:52.198Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TRMTracker",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "6.2.04",
"status": "affected",
"version": "6.2",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.3.01",
"status": "affected",
"version": "6.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The TRMTracker web application is vulnerable to LDAP injection attack potentially allowing an attacker to inject code into a query and execute remote commands that can read and update data on the website.\u003cbr\u003e"
}
],
"value": "The TRMTracker web application is vulnerable to LDAP injection attack potentially allowing an attacker to inject code into a query and execute remote commands that can read and update data on the website."
}
],
"impacts": [
{
"capecId": "CAPEC-136",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-136 LDAP Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-90",
"description": "CWE-90: Improper Neutralization of Special Elements used in an LDAP Query (\u0027LDAP Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T12:46:08.184Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000210\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-27631",
"datePublished": "2025-03-25T12:46:08.184Z",
"dateReserved": "2025-03-04T11:40:47.755Z",
"dateUpdated": "2025-03-25T13:07:52.198Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27633 (GCVE-0-2025-27633)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:40 – Updated: 2025-03-25 13:09
VLAI
Summary
The TRMTracker web application is vulnerable to reflected Cross-site scripting attack. The application allows client-side code injection that might be used to compromise the confidentiality and integrity of the system.
Severity
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TRMTracker |
Affected:
6.2 , ≤ 6.2.04
(custom)
Affected: 6.3 , ≤ 6.3.01 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27633",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:09:06.568026Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:09:15.804Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TRMTracker",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "6.2.04",
"status": "affected",
"version": "6.2",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.3.01",
"status": "affected",
"version": "6.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The TRMTracker web application is vulnerable to reflected Cross-site scripting attack. The application allows client-side code injection that might be used to compromise the confidentiality and integrity of the system."
}
],
"value": "The TRMTracker web application is vulnerable to reflected Cross-site scripting attack. The application allows client-side code injection that might be used to compromise the confidentiality and integrity of the system."
}
],
"impacts": [
{
"capecId": "CAPEC-591",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-591 Reflected XSS"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T12:40:37.667Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000210\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-27633",
"datePublished": "2025-03-25T12:40:37.667Z",
"dateReserved": "2025-03-04T11:40:47.755Z",
"dateUpdated": "2025-03-25T13:09:15.804Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1445 (GCVE-0-2025-1445)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:38 – Updated: 2025-03-25 13:09
VLAI
Summary
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active.
Precondition is that IEC61850 as client or server are configured using TLS on RTU500 device. It affects the CMU the IEC61850 stack is configured on.
Severity
CWE
- CWE-820 - Missing Synchronization
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 |
Affected:
13.7.1 , ≤ 13.7.4
(custom)
Unaffected: 13.7.6 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1445",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:09:34.307700Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:09:43.952Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "13.7.4",
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.7.6",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active.\u003cbr\u003e\u003cbr\u003ePrecondition is that IEC61850 as client or server are configured using TLS on RTU500 device. It affects the CMU the IEC61850 stack is configured on.\u003cbr\u003e"
}
],
"value": "A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active.\n\nPrecondition is that IEC61850 as client or server are configured using TLS on RTU500 device. It affects the CMU the IEC61850 stack is configured on."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/R:A",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-820",
"description": "CWE-820: Missing Synchronization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T12:38:56.794Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-1445",
"datePublished": "2025-03-25T12:38:56.794Z",
"dateReserved": "2025-02-18T15:38:20.410Z",
"dateUpdated": "2025-03-25T13:09:43.952Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27632 (GCVE-0-2025-27632)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:37 – Updated: 2025-10-24 12:10
VLAI
Summary
A Host Header Injection vulnerability in TRMTracker application may allow an attacker by modifying the host header value in an HTTP request to leverage multiple attack vectors, including defacing the site content through web-cache poisoning.
Severity
6.1 (Medium)
CWE
- CWE-644 - Improper Neutralization of HTTP Headers for Scripting Syntax
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TRMTracker |
Affected:
6.2 , ≤ 6.2.04
(custom)
Affected: 6.3 , ≤ 6.3.01 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27632",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:10:29.615743Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:10:39.102Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TRMTracker",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "6.2.04",
"status": "affected",
"version": "6.2",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.3.01",
"status": "affected",
"version": "6.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A Host Header Injection vulnerability in TRMTracker application may allow an attacker by modifying the host header value in an HTTP request to leverage multiple attack vectors, including defacing the site content through web-cache poisoning."
}
],
"value": "A Host Header Injection vulnerability in TRMTracker application may allow an attacker by modifying the host header value in an HTTP request to leverage multiple attack vectors, including defacing the site content through web-cache poisoning."
}
],
"impacts": [
{
"capecId": "CAPEC-6",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-6 Argument Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-644",
"description": "CWE-644 Improper Neutralization of HTTP Headers for Scripting Syntax",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T12:10:40.967Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000210\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2025-27632",
"datePublished": "2025-03-25T12:37:30.114Z",
"dateReserved": "2025-03-04T11:40:47.755Z",
"dateUpdated": "2025-10-24T12:10:40.967Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12169 (GCVE-0-2024-12169)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:36 – Updated: 2025-03-25 13:11
VLAI
Summary
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled.
Severity
CWE
- CWE:410 Insufficient Resource Pool
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 |
Affected:
13.4.1 , ≤ 13.4.4
(custom)
Affected: 13.5.1 , ≤ 13.5.3 (custom) Affected: 13.6.1 (custom) Affected: 13.7.1 , ≤ 13.7.4 (custom) Unaffected: 13.7.6 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12169",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:11:12.407607Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:11:20.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "13.4.4",
"status": "affected",
"version": "13.4.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.5.3",
"status": "affected",
"version": "13.5.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.6.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.7.4",
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.7.6",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled."
}
],
"value": "A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/R:A",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE:410 Insufficient Resource Pool",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T12:36:02.457Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-12169",
"datePublished": "2025-03-25T12:36:02.457Z",
"dateReserved": "2024-12-04T15:01:44.851Z",
"dateUpdated": "2025-03-25T13:11:20.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11499 (GCVE-0-2024-11499)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:30 – Updated: 2025-03-25 13:11
VLAI
Summary
A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.
The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.
Severity
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 |
Affected:
13.4.1 , ≤ 13.4.4
(custom)
Affected: 13.5.1 , ≤ 13.5.3 (custom) Affected: 13.5.3 (custom) Affected: 13.6.1 (custom) Affected: 13.7.1 (custom) Unaffected: 13.5.4 (custom) Unaffected: 13.6.2 (custom) Unaffected: 13.7.6 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:11:51.667437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:11:58.573Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "13.4.4",
"status": "affected",
"version": "13.4.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.5.3",
"status": "affected",
"version": "13.5.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.5.3",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.6.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.5.4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.6.2",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.7.6",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.\u003cbr\u003e\u003cbr\u003eThe affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability. \u003cbr\u003e\u003cbr\u003e"
}
],
"value": "A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.\n\nThe affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/R:A",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T12:30:42.034Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-11499",
"datePublished": "2025-03-25T12:30:42.034Z",
"dateReserved": "2024-11-20T13:16:55.872Z",
"dateUpdated": "2025-03-25T13:11:58.573Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10037 (GCVE-0-2024-10037)
Vulnerability from cvelistv5 – Published: 2025-03-25 12:22 – Updated: 2025-03-31 16:17
VLAI
Summary
A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.
An attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.
The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.
Severity
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | RTU500 |
Affected:
12.0.1 , ≤ 12.0.14
(custom)
Affected: 12.2.1 , ≤ 12.2.12 (custom) Affected: 12.4.1 , ≤ 12.4.11 (custom) Affected: 12.6.1 , ≤ 12.6.10 (custom) Affected: 12.7.1 , ≤ 12.7.7 (custom) Affected: 13.2.1 , ≤ 13.2.7 (custom) Affected: 13.4.1 , ≤ 13.4.4 (custom) Affected: 13.5.1 , ≤ 13.5.3 (custom) Affected: 13.6.1 Unaffected: 12.7.8 Unaffected: 13.7.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10037",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-31T16:16:55.447930Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-31T16:17:05.591Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "12.0.14",
"status": "affected",
"version": "12.0.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.2.12",
"status": "affected",
"version": "12.2.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.4.11",
"status": "affected",
"version": "12.4.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.6.10",
"status": "affected",
"version": "12.6.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.7.7",
"status": "affected",
"version": "12.7.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.2.7",
"status": "affected",
"version": "13.2.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.4.4",
"status": "affected",
"version": "13.4.1",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.5.3",
"status": "affected",
"version": "13.5.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.6.1"
},
{
"status": "unaffected",
"version": "12.7.8"
},
{
"status": "unaffected",
"version": "13.7.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.\u003cbr\u003eAn attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.\u003cbr\u003e\u003cbr\u003eThe affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.\nAn attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.\n\nThe affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/R:A",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T12:22:07.815Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-10037",
"datePublished": "2025-03-25T12:22:07.815Z",
"dateReserved": "2024-10-16T15:15:10.639Z",
"dateUpdated": "2025-03-31T16:17:05.591Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-9929 (GCVE-0-2024-9929)
Vulnerability from cvelistv5 – Published: 2024-11-26 13:31 – Updated: 2024-11-26 15:20
VLAI
Summary
A vulnerability exists in NSD570 that allows any authenticated
user to access all device logs disclosing login information with
timestamps.
Severity
4.3 (Medium)
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | NSD570 Teleprotection Equipment |
Affected:
1.0 , ≤ 1.20
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9929",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T15:17:49.844119Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T15:20:14.006Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NSD570 Teleprotection Equipment",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "1.20",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in NSD570 that allows any authenticated\nuser to access all device logs disclosing login information with\ntimestamps.\n\n\u003cbr\u003e"
}
],
"value": "A vulnerability exists in NSD570 that allows any authenticated\nuser to access all device logs disclosing login information with\ntimestamps."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:24:33.955Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000173\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-9929",
"datePublished": "2024-11-26T13:31:02.242Z",
"dateReserved": "2024-10-14T11:03:59.485Z",
"dateUpdated": "2024-11-26T15:20:14.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-9928 (GCVE-0-2024-9928)
Vulnerability from cvelistv5 – Published: 2024-11-26 13:26 – Updated: 2024-11-26 16:11
VLAI
Summary
A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could
cause account takeover and unauthorized access to the system
when an attacker conducts brute-force attacks against the
equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second
between failed login attempts making it difficult to automate the
attacks.
Severity
5.3 (Medium)
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | NSD570 Teleprotection Equipment |
Affected:
1.0 , ≤ 1.20
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:hitachienergy:nsd570_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nsd570_firmware",
"vendor": "hitachienergy",
"versions": [
{
"lessThanOrEqual": "1.20",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9928",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T15:22:53.166662Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T16:11:19.880Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NSD570 Teleprotection Equipment",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "1.20",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could\ncause account takeover and unauthorized access to the system\nwhen an attacker conducts brute-force attacks against the\nequipment login. Note that the system supports only one concurrent session and implements a delay of more than a second\nbetween failed login attempts making it difficult to automate the\nattacks.\n\n\u003cbr\u003e"
}
],
"value": "A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could\ncause account takeover and unauthorized access to the system\nwhen an attacker conducts brute-force attacks against the\nequipment login. Note that the system supports only one concurrent session and implements a delay of more than a second\nbetween failed login attempts making it difficult to automate the\nattacks."
}
],
"impacts": [
{
"capecId": "CAPEC-49",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-49 Password Brute Forcing"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T13:26:58.145Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000173\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-9928",
"datePublished": "2024-11-26T13:26:58.145Z",
"dateReserved": "2024-10-14T11:03:53.306Z",
"dateUpdated": "2024-11-26T16:11:19.880Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41156 (GCVE-0-2024-41156)
Vulnerability from cvelistv5 – Published: 2024-10-29 12:44 – Updated: 2025-01-09 17:15
VLAI
Summary
Profile files from TRO600 series radios are extracted in plain-text
and encrypted file formats. Profile files provide potential attackers
valuable configuration information about the Tropos network. Profiles
can only be exported by authenticated users with higher privilege of write access.
Severity
CWE
- CWE-212 - Improper Removal of Sensitive Information Before Storage or Transfer
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TRO600 |
Affected:
9.0.1.0 , ≤ 9.2.0.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-29T13:50:37.518941Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T17:15:38.962Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TRO600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "9.2.0.0",
"status": "affected",
"version": "9.0.1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Profile files from TRO600 series radios are extracted in plain-text\nand encrypted file formats. Profile files provide potential attackers\nvaluable configuration information about the Tropos network. Profiles\ncan only be exported by authenticated users with higher privilege of write access.\n\n\n\u003cbr\u003e"
}
],
"value": "Profile files from TRO600 series radios are extracted in plain-text\nand encrypted file formats. Profile files provide potential attackers\nvaluable configuration information about the Tropos network. Profiles\ncan only be exported by authenticated users with higher privilege of write access."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-212",
"description": "CWE-212 Improper Removal of Sensitive Information Before Storage or Transfer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-04T10:43:00.903Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-41156",
"datePublished": "2024-10-29T12:44:58.707Z",
"dateReserved": "2024-07-16T16:02:30.296Z",
"dateUpdated": "2025-01-09T17:15:38.962Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}