icsa-19-162-01
Vulnerability from csaf_cisa
Published
2019-06-11 00:00
Modified
2019-06-11 00:00
Summary
ICSA-19-162-01 Siemens Siveillance VMS
Notes
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's TXT advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
General Recommendations
As a general security measure Siemens strongly recommends to protectnetwork access to affected products with appropriate mechanisms. It isadvised to follow recommended security practices in order to run thedevices in a protected IT environment.
Terms of Use
Siemens Security Advisories are subject to the terms and conditions containedin Siemens' underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter "License Terms"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens' Global Website(https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reported this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protectnetwork access to affected products with appropriate mechanisms. It isadvised to follow recommended security practices in order to run thedevices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-212009: Vulnerabilities in Siveillance VMS",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-212009.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-162-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-162-01.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-19-162-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-162-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "ICSA-19-162-01 Siemens Siveillance VMS",
"tracking": {
"current_release_date": "2019-06-11T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-162-01",
"initial_release_date": "2019-06-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-06-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV11.2a",
"product": {
"name": "Siveillance VMS 2017 R2",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Siveillance VMS 2017 R2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.1a",
"product": {
"name": "Siveillance VMS 2018 R1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Siveillance VMS 2018 R1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.2a",
"product": {
"name": "Siveillance VMS 2018 R2",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Siveillance VMS 2018 R2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.3a",
"product": {
"name": "Siveillance VMS 2018 R3",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Siveillance VMS 2018 R3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.1a",
"product": {
"name": "Siveillance VMS 2019 R1",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Siveillance VMS 2019 R1"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-6580",
"cwe": {
"id": "CWE-862",
"name": "Missing Authorization"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6580"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V11.2a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.1a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.2a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.3a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V13.1a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Block port 80/TCP at an external firewall.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
},
{
"cve": "CVE-2019-6581",
"cwe": {
"id": "CWE-285",
"name": "Improper Authorization"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6581"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V11.2a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.1a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.2a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.3a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V13.1a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Block port 80/TCP at an external firewall.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
},
{
"cve": "CVE-2019-6582",
"cwe": {
"id": "CWE-285",
"name": "Improper Authorization"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6582"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V11.2a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.1a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.2a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V12.3a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "vendor_fix",
"details": "Update to V13.1a - Download: https://support.industry.siemens.com/cs/ww/en/ps/24899/dl",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/ps/24899/dl"
},
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Block port 80/TCP at an external firewall.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…