cve-2024-9997
Vulnerability from cvelistv5
Published
2024-10-29 21:45
Modified
2024-11-15 21:41
Severity ?
EPSS score ?
Summary
A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.
References
▼ | URL | Tags | |
---|---|---|---|
psirt@autodesk.com | https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021 | Vendor Advisory |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Autodesk | AutoCAD |
Version: 2025 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-9997", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T13:51:29.745174Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:00:57.856Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AutoCAD", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "AutoCAD LT", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "AutoCAD Architecture", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "AutoCAD Electrical", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "AutoCAD Mechanical", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "AutoCAD MEP", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "AutoCAD Plant 3D", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Civil 3D", "vendor": "AutoCAD", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Advance Steel", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "DWG TrueView", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Infrastructure Parts Editor", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Inventor", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Navisworks Manage", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Navisworks Simulate", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Revit", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] }, { "defaultStatus": "unaffected", "product": "Vault Basic Client", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2025" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.\u003cbr\u003e" } ], "value": "A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process." } ], "impacts": [ { "capecId": "CAPEC-100", "descriptions": [ { "lang": "en", "value": "CAPEC-100 Overflow Buffers" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-15T21:41:09.391Z", "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601", "shortName": "autodesk" }, "references": [ { "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021" } ], "source": { "discovery": "UNKNOWN" }, "title": "Autodesk AutoCAD DWG File Parsing Memory Corruption Code Execution Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601", "assignerShortName": "autodesk", "cveId": "CVE-2024-9997", "datePublished": "2024-10-29T21:45:59.005Z", "dateReserved": "2024-10-15T13:39:39.800Z", "dateUpdated": "2024-11-15T21:41:09.391Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-9997\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2024-10-29T22:15:09.490\",\"lastModified\":\"2024-11-01T16:27:34.960\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\" Un archivo DWG creado con fines malintencionados, cuando se analiza en acdb25.dll a trav\u00e9s de Autodesk AutoCAD, puede provocar una vulnerabilidad de corrupci\u00f3n de memoria. Un actor malintencionado puede aprovechar esta vulnerabilidad para provocar un bloqueo, escribir datos confidenciales o ejecutar c\u00f3digo arbitrario en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"8108219C-2977-47DF-8818-F7360E0AEA31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"583DCDB2-2170-4A06-B532-31886E2F1B12\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"A993F4D4-A2BA-42F7-B840-36BCCE6FF725\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"F4C616A7-A68D-42C5-88EB-9A6FE2C53116\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"F08AC00E-D022-401C-9A0F-55C5943591C8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"889BB63A-C63B-4558-B1D6-49F76E1BB2C1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"FA51DA68-070A-40F6-BF50-DBC31DCDD224\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"9DF22F44-1D3F-4F18-9835-8E0AE817377C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"C1E9CD44-2AD4-4145-9816-60D0BD468D37\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"B6F2BC95-E948-4B22-9765-D5008ABD88E8\"}]}]}],\"references\":[{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021\",\"source\":\"psirt@autodesk.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.