cve-2022-39146
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Siemens Parasolid V34.0 Version: All versions < V34.0.252
Siemens Parasolid V34.1 Version: All versions < V34.1.242
Siemens Parasolid V35.0 Version: All versions < V35.0.161
Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.555Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824: Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39146",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824: Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39146",
    "datePublished": "2022-09-13T09:41:02",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.555Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-39146\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-09-13T10:15:11.487\",\"lastModified\":\"2024-11-21T07:17:40.087\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid versiones V33.1 (Todas las versiones anteriores a V33.1.262), Parasolid versiones V33.1 (Todas las versiones posteriores a V33.1.262 incluy\u00e9ndola, anteriores a V33.1.263), Parasolid versiones V34.0 (Todas las versiones anteriores a V34.0.252), Parasolid versiones V34.1 (Todas las versiones anteriores a V34. 1.242), Parasolid versiones V35.0 (Todas las versiones anteriores a V35.0.161), Parasolid versiones V35.0 (Todas las versiones posteriores a V35.0.161 incluy\u00e9ndola, anteriores a V35.0.164), Simcenter Femap versiones V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap versiones V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicaci\u00f3n afectada es vulnerable al acceso a punteros no inicializados mientras analiza archivos X_T especialmente dise\u00f1ados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-17502)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-824\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022.1\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"55A01C08-1B67-4D81-8730-9ED534E37F7F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022.2\",\"versionEndExcluding\":\"2022.2.2\",\"matchCriteriaId\":\"7CF06743-FC11-46E1-BD60-D9F6F514E52C\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"33.1\",\"versionEndExcluding\":\"33.1.263\",\"matchCriteriaId\":\"7A2239AD-07CA-4FE9-AAFC-CE580BD903B2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.0\",\"versionEndExcluding\":\"34.0.252\",\"matchCriteriaId\":\"F0D9079D-6138-4602-A982-9BC4ECBC35E7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.1\",\"versionEndExcluding\":\"34.1.242\",\"matchCriteriaId\":\"4C486991-A1C0-4815-AAD6-163464D711AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.164\",\"matchCriteriaId\":\"E5741DD9-05D9-4F2D-AD1F-9D27D2A4070D\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.