Action not permitted
Modal body text goes here.
cve-2022-39141
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Parasolid V33.1 |
Version: All versions < V33.1.262 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T11:10:32.617Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Parasolid V33.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V33.1.262" } ] }, { "product": "Parasolid V34.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.0.252" } ] }, { "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.1.242" } ] }, { "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.161" } ] }, { "product": "Simcenter Femap V2022.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2022.1.3" } ] }, { "product": "Simcenter Femap V2022.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2022.2.2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-13T09:40:57", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-39141", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Parasolid V33.1", "version": { "version_data": [ { "version_value": "All versions \u003c V33.1.262" } ] } }, { "product_name": "Parasolid V34.0", "version": { "version_data": [ { "version_value": "All versions \u003c V34.0.252" } ] } }, { "product_name": "Parasolid V34.1", "version": { "version_data": [ { "version_value": "All versions \u003c V34.1.242" } ] } }, { "product_name": "Parasolid V35.0", "version": { "version_data": [ { "version_value": "All versions \u003c V35.0.161" } ] } }, { "product_name": "Simcenter Femap V2022.1", "version": { "version_data": [ { "version_value": "All versions \u003c V2022.1.3" } ] } }, { "product_name": "Simcenter Femap V2022.2", "version": { "version_data": [ { "version_value": "All versions \u003c V2022.2.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-39141", "datePublished": "2022-09-13T09:40:57", "dateReserved": "2022-09-01T00:00:00", "dateUpdated": "2024-08-03T11:10:32.617Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-39141\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-09-13T10:15:11.187\",\"lastModified\":\"2024-11-21T07:17:39.497\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid versiones V33.1 (Todas las versiones anteriores a V33.1.262), Parasolid versiones V34.0 (Todas las versiones anteriores a V34.0.252), Parasolid versiones V34.1 (Todas las versiones anteriores a V34.1.242), Parasolid versiones V35.0 (Todas las versiones anteriores a V35.0.161), Simcenter Femap versiones V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap versiones V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicaci\u00f3n afectada es vulnerable a la lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado cuando son analizados archivos X_T. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-17296)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022.1\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"55A01C08-1B67-4D81-8730-9ED534E37F7F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022.2\",\"versionEndExcluding\":\"2022.2.2\",\"matchCriteriaId\":\"7CF06743-FC11-46E1-BD60-D9F6F514E52C\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"33.1\",\"versionEndExcluding\":\"33.1.262\",\"matchCriteriaId\":\"9C9495DA-A41E-4B6B-BD27-B5132F38B7D4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.0\",\"versionEndExcluding\":\"34.0.252\",\"matchCriteriaId\":\"F0D9079D-6138-4602-A982-9BC4ECBC35E7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.1\",\"versionEndExcluding\":\"34.1.242\",\"matchCriteriaId\":\"4C486991-A1C0-4815-AAD6-163464D711AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.161\",\"matchCriteriaId\":\"4412F05F-EBA8-439D-868A-D14FC739E255\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
gsd-2022-39141
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-39141", "description": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)", "id": "GSD-2022-39141" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-39141" ], "details": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)", "id": "GSD-2022-39141", "modified": "2023-12-13T01:19:20.793954Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-39141", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Parasolid V33.1", "version": { "version_data": [ { "version_value": "All versions \u003c V33.1.262" } ] } }, { "product_name": "Parasolid V34.0", "version": { "version_data": [ { "version_value": "All versions \u003c V34.0.252" } ] } }, { "product_name": "Parasolid V34.1", "version": { "version_data": [ { "version_value": "All versions \u003c V34.1.242" } ] } }, { "product_name": "Parasolid V35.0", "version": { "version_data": [ { "version_value": "All versions \u003c V35.0.161" } ] } }, { "product_name": "Simcenter Femap V2022.1", "version": { "version_data": [ { "version_value": "All versions \u003c V2022.1.3" } ] } }, { "product_name": "Simcenter Femap V2022.2", "version": { "version_data": [ { "version_value": "All versions \u003c V2022.2.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.2.2", "versionStartIncluding": "2022.2", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.1.3", "versionStartIncluding": "2022.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "34.1.242", "versionStartIncluding": "34.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "34.0.252", "versionStartIncluding": "34.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "33.1.262", "versionStartIncluding": "33.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "35.0.161", "versionStartIncluding": "35.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-39141" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-09-13T15:14Z", "publishedDate": "2022-09-13T10:15Z" } } }
icsa-22-258-02
Vulnerability from csaf_cisa
Published
2022-09-15 00:00
Modified
2022-09-15 00:00
Summary
Siemens Simcenter Femap and Parasolid
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could result in remote code execution in the compromised process.
Critical infrastructure sectors
Critical Manufacturing
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.
{ "document": { "acknowledgments": [ { "organization": "Trend Micro Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens and CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could result in remote code execution in the compromised process.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-518824 Multiple File Parsing Vulnerabilities in Simcenter Femap and Parasolid - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-518824.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-258-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-258-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-258-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-258-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-518824 Multiple File Parsing Vulnerabilities in Simcenter Femap and Parasolid - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" }, { "category": "external", "summary": "SSA-518824 Multiple File Parsing Vulnerabilities in Simcenter Femap and Parasolid - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-518824.txt" } ], "title": "Siemens Simcenter Femap and Parasolid", "tracking": { "current_release_date": "2022-09-15T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-258-02", "initial_release_date": "2022-09-15T00:00:00.000000Z", "revision_history": [ { "date": "2022-09-15T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V33.1.262", "product": { "name": "Parasolid V33.1", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003e= V33.1.262 \u003c V33.1.263", "product": { "name": "Parasolid V33.1", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Parasolid V33.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V34.0.252", "product": { "name": "Parasolid V34.0", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Parasolid V34.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V34.1.242", "product": { "name": "Parasolid V34.1", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Parasolid V34.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V35.0.161", "product": { "name": "Parasolid V35.0", "product_id": "CSAFPID-0005" } }, { "category": "product_version_range", "name": "\u003e= V35.0.161 \u003c V35.0.164", "product": { "name": "Parasolid V35.0", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Parasolid V35.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2022.1.3", "product": { "name": "Simcenter Femap V2022.1", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "Simcenter Femap V2022.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2022.2.2", "product": { "name": "Simcenter Femap V2022.2", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "Simcenter Femap V2022.2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-39137", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39137" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39137" }, { "cve": "CVE-2022-39138", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17284)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39138" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39138" }, { "cve": "CVE-2022-39139", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17289)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39139" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39139" }, { "cve": "CVE-2022-39140", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17292)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39140" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39140" }, { "cve": "CVE-2022-39141", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39141" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39141" }, { "cve": "CVE-2022-39142", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17485)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39142" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39142" }, { "cve": "CVE-2022-39143", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17493)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39143" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39143" }, { "cve": "CVE-2022-39144", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17494)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39144" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39144" }, { "cve": "CVE-2022-39145", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17496)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39145" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39145" }, { "cve": "CVE-2022-39146", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39146" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39146" }, { "cve": "CVE-2022-39147", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39147" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39147" }, { "cve": "CVE-2022-39148", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17513)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39148" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39148" }, { "cve": "CVE-2022-39149", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17733)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39149" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39149" }, { "cve": "CVE-2022-39150", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17735)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39150" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39150" }, { "cve": "CVE-2022-39151", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39151" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39151" }, { "cve": "CVE-2022-39152", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39152" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39152" }, { "cve": "CVE-2022-39153", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39153" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39153" }, { "cve": "CVE-2022-39154", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39154" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39154" }, { "cve": "CVE-2022-39155", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39155" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39155" }, { "cve": "CVE-2022-39156", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-39156" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Simcenter Femap or Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Update to V33.1.262 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.0.252 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V34.1.242 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.1.3 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2022.2.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.161 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V33.1.263 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V35.0.164 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2022-39156" } ] }
ghsa-w28v-fh3p-3r9j
Vulnerability from github
Published
2022-09-14 00:00
Modified
2022-09-14 00:00
Severity ?
Details
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)
{ "affected": [], "aliases": [ "CVE-2022-39141" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-09-13T10:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)", "id": "GHSA-w28v-fh3p-3r9j", "modified": "2022-09-14T00:00:49Z", "published": "2022-09-14T00:00:49Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-39141" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.