Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-28808 (GCVE-0-2022-28808)
Vulnerability from cvelistv5
- n/a
URL | Tags | ||
---|---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:03:53.157Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.opendesign.com/security-advisories" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-17T22:19:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.opendesign.com/security-advisories" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28808", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-28808", "datePublished": "2022-07-17T22:19:05", "dateReserved": "2022-04-08T00:00:00", "dateUpdated": "2024-08-03T06:03:53.157Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-28808\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-07-17T23:15:08.573\",\"lastModified\":\"2024-11-21T06:57:58.257\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado un problema en Open Design Alliance Drawings SDK versiones anteriores a 2023.3. Se presenta una vulnerabilidad de lectura fuera de l\u00edmites cuando se leen archivos DWG en modo de recuperaci\u00f3n. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2023.3\",\"matchCriteriaId\":\"8AC10824-B014-4128-9C43-161838056F9C\"}]}]}],\"references\":[{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
fkie_cve-2022-28808
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
cve@mitre.org | https://www.opendesign.com/security-advisories | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.opendesign.com/security-advisories | Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
opendesign | drawings_sdk | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC10824-B014-4128-9C43-161838056F9C", "versionEndExcluding": "2023.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha detectado un problema en Open Design Alliance Drawings SDK versiones anteriores a 2023.3. Se presenta una vulnerabilidad de lectura fuera de l\u00edmites cuando se leen archivos DWG en modo de recuperaci\u00f3n. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual" } ], "id": "CVE-2022-28808", "lastModified": "2024-11-21T06:57:58.257", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-07-17T23:15:08.573", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.opendesign.com/security-advisories" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.opendesign.com/security-advisories" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ICSA-23-320-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. \n\nSiemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-137900.json" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-137900.html" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-137900.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2023-11-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-320-09", "initial_release_date": "2023-11-14T00:00:00.000000Z", "revision_history": [ { "date": "2023-11-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV10.4.4", "product": { "name": "COMOS", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "COMOS", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-25020", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "summary", "text": "MPXJ through 8.1.3 allows XXE attacks. This affects the GanttProjectReader and PhoenixReader components.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-25020" }, { "cve": "CVE-2020-35460", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "common/InputStreamHelper.java in Packwood MPXJ before 8.3.5 allows directory traversal in the zip stream handler flow, leading to the writing of files to arbitrary locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-35460" }, { "cve": "CVE-2022-23095", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.12.1 mishandles the loading of JPG files. Unchecked input data from a crafted JPG file leads to memory corruption. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-23095" }, { "cve": "CVE-2022-28807", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable\r\nto an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-28807" }, { "cve": "CVE-2022-28808", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading DWG files in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-28808" }, { "cve": "CVE-2022-28809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading a DWG file with invalid vertex number in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-28809" }, { "cve": "CVE-2023-0933", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Integer overflow in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-0933" }, { "cve": "CVE-2023-1530", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-1530" }, { "cve": "CVE-2023-2931", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-2931" }, { "cve": "CVE-2023-2932", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-2932" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer overflow while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer overflow while parsing specially crafted DXF files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-43503", "cwe": { "id": "CWE-319", "name": "Cleartext Transmission of Sensitive Information" }, "notes": [ { "category": "summary", "text": "Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "For CVE-2023-43503, update to V10.4.4 or later version and update the COMOS database to version 25. (See \u201cData maintenance: Modifying the version\u201d in the user manual. Warning: After the update, the database cannot be used by older COMOS versions)", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-43503" }, { "cve": "CVE-2023-43504", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "For CVE-2023-43504, delete ptmcast.exe from bin folder of COMOS installation directory. Installations from COMOS V10.4.4 or later version does not contain ptmcast.exe", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-43504" }, { "cve": "CVE-2023-43505", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application lacks proper access controls in SMB shares. This could allow an attacker to access files that the user should not have access to.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "CVE-2023-43505, CVE-2023-46601: Use an application server like Citrix which builds an additional layer of access control around COMOS. The file share with the documents folder and the database should be only accessible by the application server. You can find further recommendations in the COMOS manual \u201cSecurityrelevant configuration\u201d in COMOS documentation (\nhttps://support.industry.siemens.com/cs/document/109823629/)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-43505" }, { "cve": "CVE-2023-46601", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application lacks proper access controls in making the SQLServer connection. This could allow an attacker to query the database directly to access information that the user should not have access to.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "CVE-2023-43505, CVE-2023-46601: Use an application server like Citrix which builds an additional layer of access control around COMOS. The file share with the documents folder and the database should be only accessible by the application server. You can find further recommendations in the COMOS manual \u201cSecurityrelevant configuration\u201d in COMOS documentation (\nhttps://support.industry.siemens.com/cs/document/109823629/)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-46601" } ] }
icsa-22-195-11
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "organization": "Open Design Alliance", "summary": "coordination efforts" }, { "names": [ "Yonghui Han" ], "organization": "FortiGuard Labs", "summary": "coordinating disclosure" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "JT2Go and Teamcenter Visualization are affected by multiple file\nparsing vulnerabilities in Drawings SDK from Open Design Alliance. If\na user is tricked to open a malicious DWG file with any of the\naffected products, this could lead the application to crash or\npotentially lead to arbitrary code execution. Siemens has released\nupdates for the affected products and recommends to update to the\nlatest versions. Note: - This advisory covers security\nvulnerabilities recently disclosed by Open Design Alliance [0] [0]\nhttps://www.opendesign.com/security-\nadvisories", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-429204.json" }, { "category": "self", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-429204.txt" }, { "category": "self", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-429204.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-22-195-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-195-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-195-11 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-195-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Open Design Alliance Drawings SDK", "tracking": { "current_release_date": "2022-09-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-195-11", "initial_release_date": "2022-07-12T00:00:00.000000Z", "revision_history": [ { "date": "2022-07-12T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2022-08-09T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Teamcenter Visualization version lines V13.2 and V14.0" }, { "date": "2022-09-13T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Teamcenter Visualization version line V12.4" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV13.3.0.5", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV12.4.0.15", "product": { "name": "Teamcenter Visualization V12.4", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V12.4" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.9", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.3.0.5", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.0.0.2", "product": { "name": "Teamcenter Visualization V14.0", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.0" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-28807", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable\r\nto an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28807" }, { "cve": "CVE-2022-28808", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading DWG files in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28808" }, { "cve": "CVE-2022-28809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading a DWG file with invalid vertex number in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28809" } ] }
ICSA-22-195-11
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "organization": "Open Design Alliance", "summary": "coordination efforts" }, { "names": [ "Yonghui Han" ], "organization": "FortiGuard Labs", "summary": "coordinating disclosure" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "JT2Go and Teamcenter Visualization are affected by multiple file\nparsing vulnerabilities in Drawings SDK from Open Design Alliance. If\na user is tricked to open a malicious DWG file with any of the\naffected products, this could lead the application to crash or\npotentially lead to arbitrary code execution. Siemens has released\nupdates for the affected products and recommends to update to the\nlatest versions. Note: - This advisory covers security\nvulnerabilities recently disclosed by Open Design Alliance [0] [0]\nhttps://www.opendesign.com/security-\nadvisories", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-429204.json" }, { "category": "self", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-429204.txt" }, { "category": "self", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-429204.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-22-195-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-195-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-195-11 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-195-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Open Design Alliance Drawings SDK", "tracking": { "current_release_date": "2022-09-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-195-11", "initial_release_date": "2022-07-12T00:00:00.000000Z", "revision_history": [ { "date": "2022-07-12T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2022-08-09T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Teamcenter Visualization version lines V13.2 and V14.0" }, { "date": "2022-09-13T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Teamcenter Visualization version line V12.4" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV13.3.0.5", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV12.4.0.15", "product": { "name": "Teamcenter Visualization V12.4", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V12.4" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.9", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.3.0.5", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.0.0.2", "product": { "name": "Teamcenter Visualization V14.0", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.0" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-28807", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable\r\nto an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28807" }, { "cve": "CVE-2022-28808", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading DWG files in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28808" }, { "cve": "CVE-2022-28809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading a DWG file with invalid vertex number in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28809" } ] }
icsa-23-320-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. \n\nSiemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-137900.json" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-137900.html" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-137900.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2023-11-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-320-09", "initial_release_date": "2023-11-14T00:00:00.000000Z", "revision_history": [ { "date": "2023-11-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV10.4.4", "product": { "name": "COMOS", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "COMOS", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-25020", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "summary", "text": "MPXJ through 8.1.3 allows XXE attacks. This affects the GanttProjectReader and PhoenixReader components.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-25020" }, { "cve": "CVE-2020-35460", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "common/InputStreamHelper.java in Packwood MPXJ before 8.3.5 allows directory traversal in the zip stream handler flow, leading to the writing of files to arbitrary locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-35460" }, { "cve": "CVE-2022-23095", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.12.1 mishandles the loading of JPG files. Unchecked input data from a crafted JPG file leads to memory corruption. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-23095" }, { "cve": "CVE-2022-28807", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable\r\nto an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-28807" }, { "cve": "CVE-2022-28808", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading DWG files in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-28808" }, { "cve": "CVE-2022-28809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading a DWG file with invalid vertex number in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-28809" }, { "cve": "CVE-2023-0933", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Integer overflow in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-0933" }, { "cve": "CVE-2023-1530", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-1530" }, { "cve": "CVE-2023-2931", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-2931" }, { "cve": "CVE-2023-2932", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-2932" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer overflow while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer overflow while parsing specially crafted DXF files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-43503", "cwe": { "id": "CWE-319", "name": "Cleartext Transmission of Sensitive Information" }, "notes": [ { "category": "summary", "text": "Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "For CVE-2023-43503, update to V10.4.4 or later version and update the COMOS database to version 25. (See \u201cData maintenance: Modifying the version\u201d in the user manual. Warning: After the update, the database cannot be used by older COMOS versions)", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-43503" }, { "cve": "CVE-2023-43504", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "For CVE-2023-43504, delete ptmcast.exe from bin folder of COMOS installation directory. Installations from COMOS V10.4.4 or later version does not contain ptmcast.exe", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-43504" }, { "cve": "CVE-2023-43505", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application lacks proper access controls in SMB shares. This could allow an attacker to access files that the user should not have access to.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "CVE-2023-43505, CVE-2023-46601: Use an application server like Citrix which builds an additional layer of access control around COMOS. The file share with the documents folder and the database should be only accessible by the application server. You can find further recommendations in the COMOS manual \u201cSecurityrelevant configuration\u201d in COMOS documentation (\nhttps://support.industry.siemens.com/cs/document/109823629/)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-43505" }, { "cve": "CVE-2023-46601", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application lacks proper access controls in making the SQLServer connection. This could allow an attacker to query the database directly to access information that the user should not have access to.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "CVE-2023-43505, CVE-2023-46601: Use an application server like Citrix which builds an additional layer of access control around COMOS. The file share with the documents folder and the database should be only accessible by the application server. You can find further recommendations in the COMOS manual \u201cSecurityrelevant configuration\u201d in COMOS documentation (\nhttps://support.industry.siemens.com/cs/document/109823629/)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-46601" } ] }
gsd-2022-28808
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-28808", "description": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2022-28808" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-28808" ], "details": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2022-28808", "modified": "2023-12-13T01:19:34.070039Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28808", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2023.3", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28808" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.opendesign.com/security-advisories" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-07-25T14:56Z", "publishedDate": "2022-07-17T23:15Z" } } }
ghsa-g857-242h-9m66
Vulnerability from github
An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2022-28808" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-07-17T23:15:00Z", "severity": "HIGH" }, "details": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading DWG files in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GHSA-g857-242h-9m66", "modified": "2022-07-26T00:01:06Z", "published": "2022-07-18T00:00:32Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-28808" }, { "type": "WEB", "url": "https://www.opendesign.com/security-advisories" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
CERTFR-2022-AVI-627
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Mendix Applications using Mendix versions 9 (9.12) antérieures à 9.12.2 | ||
Siemens | N/A | Teamcenter Visualization V12.4 toutes versions | ||
Siemens | N/A | SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) versions antérieures à 3.0.22 | ||
Siemens | N/A | EN100 Ethernet module IEC 104 variant toutes versions | ||
Siemens | N/A | SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) versions antérieures à 2.0 | ||
Siemens | N/A | SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) toutes versions | ||
Siemens | N/A | SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) versions antérieures à 2.0 | ||
Siemens | N/A | SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) versions antérieures à 3.0.22 | ||
Siemens | N/A | SICAM GridEdge Essential ARM (6MD7881-2AA30) toutes versions | ||
Siemens | N/A | Mendix Applications using Mendix versions 8 antérieures à 8.18.18 | ||
Siemens | N/A | EN100 Ethernet module Modbus TCP variant toutes versions | ||
Siemens | N/A | SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) à SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) toutes versions | ||
Siemens | N/A | Teamcenter Visualization toutes versions 14.0.x | ||
Siemens | N/A | RUGGEDCOM ROX MX5000 à RX5000 versions antérieures à 2.15.1 | ||
Siemens | N/A | Mendix Excel Importer Module (Mendix 8 compatible) versions antérieures à 9.2.2 | ||
Siemens | N/A | SIMATIC MV540 H (6GF3540-0GE10) versions antérieures à 3.3 | ||
Siemens | N/A | SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) versions antérieures à 2.0 | ||
Siemens | N/A | Opcenter Quality versions 13.2 antérieures à 13.2.20220624 | ||
Siemens | N/A | SIMATIC MV540 S (6GF3540-0CD10) versions antérieures à 3.3 | ||
Siemens | N/A | Teamcenter Visualization versions 13.3.x antérieures à 13.3.0.5 | ||
Siemens | N/A | RUGGEDCOM ROS toutes versions : Se référer à l'avis éditeur pour la liste exacte des produits RUGGEDCOM concernés et des correctifs disponibles | ||
Siemens | N/A | Parasolid V34.0 versions antérieures à 34.0.250 | ||
Siemens | N/A | SIMATIC MV550 H (6GF3550-0GE10) versions antérieures à 3.3 | ||
Siemens | N/A | Mendix Applications using Mendix 9 versions 9.12 antérieure à 9.12.3 | ||
Siemens | N/A | Mendix Applications using Mendix versions 7 antérieures à 7.23.31 | ||
Siemens | N/A | CP-8021 MASTER MODULE (6MF2802-1AA00) versions antérieures à CPC80 V16.30 | ||
Siemens | N/A | Simcenter Femap versions antérieures à 2022.2 | ||
Siemens | N/A | EN100 Ethernet module PROFINET IO variant toutes versions | ||
Siemens | N/A | SICAM GridEdge Essential Intel (6MD7881-2AA40) versions antérieures à 2.7.3 | ||
Siemens | N/A | SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) versions antérieures à 2.0 | ||
Siemens | N/A | CP-8000 MASTER MODULE WITH I/O -40/+70°C (6MF2101-1AB10-0AA0) versions antérieures à CPC80 V16.30 | ||
Siemens | N/A | SIMATIC MV550 S (6GF3550-0CD10) versions antérieures à 3.3 | ||
Siemens | N/A | SICAM GridEdge Essential with GDS ARM (6MD7881-2AA10) toutes versions | ||
Siemens | N/A | Mendix Applications using Mendix 9 versions supérieures ou égales à 9.11 et antérieures à 9.15 | ||
Siemens | N/A | EN100 Ethernet module DNP3 IP variant toutes versions | ||
Siemens | N/A | Parasolid V33.1 toutes versions | ||
Siemens | N/A | JT2Go versions antérieures à 13.3.0.5 | ||
Siemens | N/A | Opcenter Quality versions 13.1 antérieures à 13.1.20220624 | ||
Siemens | N/A | EN100 Ethernet module IEC 61850 variant versions antérieures à 4.40 | ||
Siemens | N/A | SIMATIC MV560 X (6GF3560-0HE10) versions antérieures à 3.3 | ||
Siemens | N/A | Simcenter Femap toutes versions | ||
Siemens | N/A | Teamcenter Visualization V14.0 toutes versions | ||
Siemens | N/A | Teamcenter Visualization V13.2 toutes versions | ||
Siemens | N/A | SIMATIC MV560 U (6GF3560-0LE10) versions antérieures à 3.3 | ||
Siemens | N/A | Mendix Applications using Mendix versions 9 antérieures à 9.14.0 | ||
Siemens | N/A | Mendix Excel Importer Module (Mendix 9 compatible) versions antérieures à 10.1.2 | ||
Siemens | N/A | CP-8022 MASTER MODULE WITH GPRS (6MF2802-2AA00) versions antérieures à CPC80 V16.30 | ||
Siemens | N/A | SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) versions antérieures à 22.00 | ||
Siemens | N/A | SICAM GridEdge Essential with GDS Intel (6MD7881-2AA20) versions antérieures à 2.7.3 | ||
Siemens | N/A | Disques SINAMICS PERFECT HARMONY GH180 Drives fabriqués depuis 2015 avant 2021 | ||
Siemens | N/A | SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) à SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) toutes versions : Se référer à l'avis éditeur pour la liste exacte des produits SCALANCE concernés et des correctifs disponibles | ||
Siemens | N/A | SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) versions antérieures à 2.0 | ||
Siemens | N/A | SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) toutes versions | ||
Siemens | N/A | CP-8000 MASTER MODULE WITH I/O -25/+70°C (6MF2101-0AB10-0AA0) versions antérieures à CPC80 V16.30 | ||
Siemens | N/A | Mendix Applications using Mendix versions 9 (9.6) antérieures à 9.6.12 | ||
Siemens | N/A | PADS Standard/Plus Viewer toutes versions | ||
Siemens | N/A | SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) toutes versions : Se référer à l'avis éditeur pour la liste exacte des produits SIMATIC concernés et des correctifs disponibles | ||
Siemens | N/A | Parasolid V34.1 versions antérieures à 34.1.233 |
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Mendix Applications using Mendix versions 9 (9.12) ant\u00e9rieures \u00e0 9.12.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization V12.4 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) versions ant\u00e9rieures \u00e0 3.0.22", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "EN100 Ethernet module IEC 104 variant toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) versions ant\u00e9rieures \u00e0 2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) versions ant\u00e9rieures \u00e0 2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) versions ant\u00e9rieures \u00e0 3.0.22", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM GridEdge Essential ARM (6MD7881-2AA30) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix versions 8 ant\u00e9rieures \u00e0 8.18.18", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "EN100 Ethernet module Modbus TCP variant toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) \u00e0 SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization toutes versions 14.0.x", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX MX5000 \u00e0 RX5000 versions ant\u00e9rieures \u00e0 2.15.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Excel Importer Module (Mendix 8 compatible) versions ant\u00e9rieures \u00e0 9.2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV540 H (6GF3540-0GE10) versions ant\u00e9rieures \u00e0 3.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) versions ant\u00e9rieures \u00e0 2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Quality versions 13.2 ant\u00e9rieures \u00e0 13.2.20220624", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV540 S (6GF3540-0CD10) versions ant\u00e9rieures \u00e0 3.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROS toutes versions : Se r\u00e9f\u00e9rer \u00e0 l\u0027avis \u00e9diteur pour la liste exacte des produits RUGGEDCOM concern\u00e9s et des correctifs disponibles", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V34.0 versions ant\u00e9rieures \u00e0 34.0.250", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV550 H (6GF3550-0GE10) versions ant\u00e9rieures \u00e0 3.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 9 versions 9.12 ant\u00e9rieure \u00e0 9.12.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix versions 7 ant\u00e9rieures \u00e0 7.23.31", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8021 MASTER MODULE (6MF2802-1AA00) versions ant\u00e9rieures \u00e0 CPC80 V16.30", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap versions ant\u00e9rieures \u00e0 2022.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "EN100 Ethernet module PROFINET IO variant toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM GridEdge Essential Intel (6MD7881-2AA40) versions ant\u00e9rieures \u00e0 2.7.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) versions ant\u00e9rieures \u00e0 2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (6MF2101-1AB10-0AA0) versions ant\u00e9rieures \u00e0 CPC80 V16.30", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV550 S (6GF3550-0CD10) versions ant\u00e9rieures \u00e0 3.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM GridEdge Essential with GDS ARM (6MD7881-2AA10) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 9 versions sup\u00e9rieures ou \u00e9gales \u00e0 9.11 et ant\u00e9rieures \u00e0 9.15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "EN100 Ethernet module DNP3 IP variant toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V33.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT2Go versions ant\u00e9rieures \u00e0 13.3.0.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Quality versions 13.1 ant\u00e9rieures \u00e0 13.1.20220624", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "EN100 Ethernet module IEC 61850 variant versions ant\u00e9rieures \u00e0 4.40", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV560 X (6GF3560-0HE10) versions ant\u00e9rieures \u00e0 3.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization V14.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization V13.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV560 U (6GF3560-0LE10) versions ant\u00e9rieures \u00e0 3.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix versions 9 ant\u00e9rieures \u00e0 9.14.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Excel Importer Module (Mendix 9 compatible) versions ant\u00e9rieures \u00e0 10.1.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8022 MASTER MODULE WITH GPRS (6MF2802-2AA00) versions ant\u00e9rieures \u00e0 CPC80 V16.30", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) versions ant\u00e9rieures \u00e0 22.00", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM GridEdge Essential with GDS Intel (6MD7881-2AA20) versions ant\u00e9rieures \u00e0 2.7.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Disques SINAMICS PERFECT HARMONY GH180 Drives fabriqu\u00e9s depuis 2015 avant 2021", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) \u00e0 SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) toutes versions : Se r\u00e9f\u00e9rer \u00e0 l\u0027avis \u00e9diteur pour la liste exacte des produits SCALANCE concern\u00e9s et des correctifs disponibles", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) versions ant\u00e9rieures \u00e0 2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (6MF2101-0AB10-0AA0) versions ant\u00e9rieures \u00e0 CPC80 V16.30", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix versions 9 (9.6) ant\u00e9rieures \u00e0 9.6.12", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PADS Standard/Plus Viewer toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) toutes versions : Se r\u00e9f\u00e9rer \u00e0 l\u0027avis \u00e9diteur pour la liste exacte des produits SIMATIC concern\u00e9s et des correctifs disponibles", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V34.1 versions ant\u00e9rieures \u00e0 34.1.233", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2022-34820", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34820" }, { "name": "CVE-2022-34819", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34819" }, { "name": "CVE-2022-34277", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34277" }, { "name": "CVE-2022-31257", "url": "https://www.cve.org/CVERecord?id=CVE-2022-31257" }, { "name": "CVE-2022-34288", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34288" }, { "name": "CVE-2022-29884", "url": "https://www.cve.org/CVERecord?id=CVE-2022-29884" }, { "name": "CVE-2022-34280", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34280" }, { "name": "CVE-2022-28809", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28809" }, { "name": "CVE-2022-34663", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34663" }, { "name": "CVE-2022-34286", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34286" }, { "name": "CVE-2021-44222", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44222" }, { "name": "CVE-2022-29560", "url": "https://www.cve.org/CVERecord?id=CVE-2022-29560" }, { "name": "CVE-2022-34748", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34748" }, { "name": "CVE-2022-34287", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34287" }, { "name": "CVE-2022-34275", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34275" }, { "name": "CVE-2022-34291", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34291" }, { "name": "CVE-2022-34274", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34274" }, { "name": "CVE-2022-34273", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34273" }, { "name": "CVE-2022-28808", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28808" }, { "name": "CVE-2021-29998", "url": "https://www.cve.org/CVERecord?id=CVE-2021-29998" }, { "name": "CVE-2022-33736", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33736" }, { "name": "CVE-2022-34466", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34466" }, { "name": "CVE-2022-34272", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34272" }, { "name": "CVE-2022-34284", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34284" }, { "name": "CVE-2022-26648", "url": "https://www.cve.org/CVERecord?id=CVE-2022-26648" }, { "name": "CVE-2022-34276", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34276" }, { "name": "CVE-2022-34289", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34289" }, { "name": "CVE-2022-34821", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34821" }, { "name": "CVE-2022-28807", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28807" }, { "name": "CVE-2022-34465", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34465" }, { "name": "CVE-2022-33137", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33137" }, { "name": "CVE-2022-34283", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34283" }, { "name": "CVE-2022-34278", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34278" }, { "name": "CVE-2022-34282", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34282" }, { "name": "CVE-2022-34290", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34290" }, { "name": "CVE-2022-26647", "url": "https://www.cve.org/CVERecord?id=CVE-2022-26647" }, { "name": "CVE-2022-34279", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34279" }, { "name": "CVE-2022-34467", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34467" }, { "name": "CVE-2022-34281", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34281" }, { "name": "CVE-2022-26649", "url": "https://www.cve.org/CVERecord?id=CVE-2022-26649" }, { "name": "CVE-2021-44221", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44221" }, { "name": "CVE-2022-34464", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34464" }, { "name": "CVE-2022-34285", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34285" }, { "name": "CVE-2022-33138", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33138" }, { "name": "CVE-2022-2069", "url": "https://www.cve.org/CVERecord?id=CVE-2022-2069" }, { "name": "CVE-2022-30938", "url": "https://www.cve.org/CVERecord?id=CVE-2022-30938" } ], "initial_release_date": "2022-07-12T00:00:00", "last_revision_date": "2022-07-12T00:00:00", "links": [], "reference": "CERTFR-2022-AVI-627", "revisions": [ { "description": "Version initiale", "revision_date": "2022-07-12T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-517377 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-599506 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-599506.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-243317 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-243317.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-429204 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-429204.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-829738 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-829738.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-610768 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-610768.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-492173 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-492173.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-348662 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-348662.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-580125 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-580125.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-840800 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-840800.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-225578 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-225578.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-491621 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-491621.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-433782 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-433782.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-910883 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-910883.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-474231 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-474231.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-865333 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-865333.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-439148 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-439148.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-310038 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-310038.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-944952 du 12 juillet 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-944952.html" } ] }
CERTFR-2023-AVI-0935
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une exécution de code arbitraire à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | RUGGEDCOM RSG920P V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE XC208G (6GK5208-0GA00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) toutes les versions | ||
Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) toutes les versions | ||
Siemens | N/A | Applications Mendix basées sur Mendix 10 versions antérieures à V10.4.0 | ||
Siemens | N/A | RUGGEDCOM RS416PNC toutes les versions | ||
Siemens | N/A | SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2200NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS8000NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2300PF toutes les versions | ||
Siemens | N/A | SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS416Pv2 V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RST2228P versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC208EEC (6GK5208-0BA00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2300P V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS969 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS940GNC toutes les versions | ||
Siemens | N/A | SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) toutes les versions | ||
Siemens | N/A | Mendix Studio Pro 8 versions antérieures à V8.18.27 | ||
Siemens | N/A | RUGGEDCOM RS900GNC toutes les versions | ||
Siemens | N/A | RUGGEDCOM M2200F toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2200F toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900LNC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416PNCv2 V5.X toutes les versions | ||
Siemens | N/A | SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | Siemens OPC UA Modelling Editor (SiOME) versions antérieures à V2.8 | ||
Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2488NC V5.X toutes les versions | ||
Siemens | N/A | SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS1600TNC toutes les versions | ||
Siemens | N/A | SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM M2100 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XC208 (6GK5208-0BA00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2288NC V4.X toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) toutes les versions | ||
Siemens | N/A | SCALANCE XP216EEC (6GK5216-0HA00-2ES6) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC216-4C G (6GK5216-4GS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900M-GETS-XX versions antérieures à V4.3.8 | ||
Siemens | N/A | Mendix Studio Pro 10 versions antérieures à V10.3.1 | ||
Siemens | N/A | SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XP208EEC (6GK5208-0HA00-2ES6) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900MNC-GETS-C01 toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900NC(32M) V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM M2200 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XP216 (6GK5216-0HA00-2AS6) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM i801NC toutes les versions | ||
Siemens | N/A | SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RST916C versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM i800 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RSG2300NC V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS910LNC toutes les versions | ||
Siemens | N/A | Tecnomatix Plant Simulation V2302 versions antérieures à V2302.0004 | ||
Siemens | N/A | RUGGEDCOM RS900GP versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS400 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS900M-STND-C01 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS940GF toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416F toutes les versions | ||
Siemens | N/A | SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) toutes les versions | ||
Siemens | N/A | SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2100 (32M) V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RSG2300 V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS900 (32M) V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900G versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RMC8388NC V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RMC8388NC V4.X toutes les versions | ||
Siemens | N/A | SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900GF toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2288 V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | SINEC PNI versions antérieures à V2.0 | ||
Siemens | N/A | SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2488NC V4.X toutes les versions | ||
Siemens | N/A | Desigo CC product family V7 toutes les versions sans le dernier correctif de sécurité | ||
Siemens | N/A | SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS8000TNC toutes les versions | ||
Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) toutes les versions | ||
Siemens | N/A | SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS400NC toutes les versions | ||
Siemens | N/A | SCALANCE XF204 DNA (6GK5204-0BA00-2YF2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM i803NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS910W versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC216-4C (6GK5216-4BS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC224-4C G (6GK5224-4GS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS416NCv2 V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2100F toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2100PF toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS1600T versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC208G EEC (6GK5208-0GA00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | Desigo CC product family V5.0 toutes les versions sans le dernier correctif de sécurité | ||
Siemens | N/A | SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2300PNC V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2300P V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RMC30 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS920W versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS416PF toutes les versions | ||
Siemens | N/A | RUGGEDCOM i803 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM APE1808 toutes versions utilisées avec Nozomi Guardian / CMC versions V22.6.3 à 23.1.0sans le dernier correctif de sécurité | ||
Siemens | N/A | Applications Mendix basées sur Mendix 7.x versions antérieures à V7.23.37 | ||
Siemens | N/A | RUGGEDCOM RSG908C versions antérieures à V5.6.0 | ||
Siemens | N/A | Applications Mendix basées sur Mendix 9.x versions antérieures à V9.24.10 | ||
Siemens | N/A | RUGGEDCOM RSG920P V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS900W versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XF204-2BA (6GK5204-2AA00-2GF2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS401NC toutes les versions | ||
Siemens | N/A | SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes les versions | ||
Siemens | N/A | SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) toutes les versions | ||
Siemens | N/A | Desigo CC product family V5.1 toutes les versions sans le dernier correctif de sécurité | ||
Siemens | N/A | SCALANCE XC224 (6GK5224-0BA00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900MNC-STND-XX toutes les versions | ||
Siemens | N/A | SIMATIC MV500 family versions antérieures à V3.3.5 | ||
Siemens | N/A | RUGGEDCOM RST916P versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS401 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2488 V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS910 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416v2 V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RSG2488F toutes les versions | ||
Siemens | N/A | SCALANCE XC216EEC (6GK5216-0BA00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900GNC(32M) V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RST2228 versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS416P versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RSG2288NC V5.X toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM M2100F toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS8000 versions antérieures à V4.3.8 | ||
Siemens | N/A | Applications Mendix basées sur Mendix 8.x versions antérieures à V8.18.27 | ||
Siemens | N/A | SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) toutes les versions | ||
Siemens | N/A | SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RP110NC toutes les versions | ||
Siemens | N/A | SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2100P versions antérieures à V4.3.8 | ||
Siemens | N/A | SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM M969F toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900GPF toutes les versions | ||
Siemens | N/A | SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG907R versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM i802 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM M969 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RSG920PNC V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS920L versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS900MNC-STND-XX-C01 toutes les versions | ||
Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900F toutes les versions | ||
Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900G (32M) V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) toutes les versions | ||
Siemens | N/A | SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) toutes les versions | ||
Siemens | N/A | Simcenter Femap V2301 versions antérieures à V2301.0003 | ||
Siemens | N/A | RUGGEDCOM RSG2100NC(32M) V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2288 V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RSG920PNC V4.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS8000H versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RMC8388 V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RSG910C versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG909R versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416PNCv2 V4.X toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS910NC toutes les versions | ||
Siemens | N/A | SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) toutes les versions | ||
Siemens | N/A | SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes les versions | ||
Siemens | N/A | SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | Desigo CC product family V6 toutes les versions sans le dernier correctif de sécurité | ||
Siemens | N/A | RUGGEDCOM RS416Pv2 V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) toutes les versions | ||
Siemens | N/A | RUGGEDCOM i800NC toutes les versions | ||
Siemens | N/A | SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS930LNC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RMC8388 V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | SIMATIC PCS neo versions antérieures à V4.1 | ||
Siemens | N/A | RUGGEDCOM RS900M-STND-XX versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS910L versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) toutes les versions | ||
Siemens | N/A | RUGGEDCOM i802NC toutes les versions | ||
Siemens | N/A | SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS1600FNC toutes les versions | ||
Siemens | N/A | SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2100PNC toutes les versions | ||
Siemens | N/A | SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS400F toutes les versions | ||
Siemens | N/A | Mendix Studio Pro 7 versions antérieures à V7.23.37 | ||
Siemens | N/A | RUGGEDCOM RSG2100 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS8000A versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS900L versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS920LNC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS8000T versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) toutes les versions | ||
Siemens | N/A | SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RMC30NC toutes les versions | ||
Siemens | N/A | COMOS versions antérieures à V10.4.4, les vulnérabilités CVE-2023-43505, CVE-2023-46601 ne seront pas corrigées par l'éditeur | ||
Siemens | N/A | RUGGEDCOM RS900GNC(32M) V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2488 V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS8000ANC toutes les versions | ||
Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE XC216 (6GK5216-0BA00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS930L versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) toutes les versions | ||
Siemens | N/A | SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) toutes les versions | ||
Siemens | N/A | SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSL910NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2300 V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RSG2300PNC V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM i801 versions antérieures à V4.3.8 | ||
Siemens | N/A | Mendix Studio Pro 9 versions antérieures à V9.24.0 | ||
Siemens | N/A | RUGGEDCOM M2100NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416NCv2 V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2100NC toutes les versions | ||
Siemens | N/A | SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900M-GETS-C01 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS969NC toutes les versions | ||
Siemens | N/A | SCALANCE XP208 (6GK5208-0HA00-2AS6) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC208G PoE (6GK5208-0RA00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS900G (32M) V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | Tecnomatix Plant Simulation V2201 versions antérieures à V2201.0010 | ||
Siemens | N/A | SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS8000HNC toutes les versions | ||
Siemens | N/A | SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | Simcenter Femap V2306 versions antérieures à V2306.0001 | ||
Siemens | N/A | RUGGEDCOM RP110 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS900 (32M) V4.X versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RSG2100 (32M) V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM M969NC toutes les versions | ||
Siemens | N/A | SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2) versions antérieures à V4.5 | ||
Siemens | N/A | SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSL910 versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS1600F versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS900NC(32M) V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416 versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) toutes les versions | ||
Siemens | N/A | SCALANCE XF204 (6GK5204-0BA00-2GF2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2300NC V5.X toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS900MNC-GETS-XX toutes les versions | ||
Siemens | N/A | SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS930W versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM M2200NC toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416v2 V5.X versions antérieures à V5.6.0 | ||
Siemens | N/A | RUGGEDCOM RS900GPNC toutes les versions | ||
Siemens | N/A | SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) toutes les versions | ||
Siemens | N/A | SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS1600 versions antérieures à V4.3.8 | ||
Siemens | N/A | RUGGEDCOM RS940G versions antérieures à V4.3.8 | ||
Siemens | N/A | SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) toutes les versions | ||
Siemens | N/A | SIPROTEC 4 7SJ66 versions antérieures à V4.41 | ||
Siemens | N/A | RUGGEDCOM RSG2300F toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) toutes les versions | ||
Siemens | N/A | SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RS1600NC toutes les versions | ||
Siemens | N/A | SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2) versions antérieures à V4.5 | ||
Siemens | N/A | RUGGEDCOM RSG2100NC(32M) V5.X toutes les versions | ||
Siemens | N/A | SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) toutes les versions | ||
Siemens | N/A | SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RS416NC toutes les versions | ||
Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) toutes les versions | ||
Siemens | N/A | RUGGEDCOM RSG2200 versions antérieures à V4.3.8 |
Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "RUGGEDCOM RSG920P V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208G (6GK5208-0GA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications Mendix bas\u00e9es sur Mendix 10 versions ant\u00e9rieures \u00e0 V10.4.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416PNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2200NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300PF toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416Pv2 V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RST2228P versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300P V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS969 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS940GNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Studio Pro 8 versions ant\u00e9rieures \u00e0 V8.18.27", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M2200F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2200F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900LNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416PNCv2 V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siemens OPC UA Modelling Editor (SiOME) versions ant\u00e9rieures \u00e0 V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2488NC V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS1600TNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M2100 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208 (6GK5208-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2288NC V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900M-GETS-XX versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Studio Pro 10 versions ant\u00e9rieures \u00e0 V10.3.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900MNC-GETS-C01 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900NC(32M) V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M2200 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP216 (6GK5216-0HA00-2AS6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i801NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RST916C versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i800 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300NC V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS910LNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Tecnomatix Plant Simulation V2302 versions ant\u00e9rieures \u00e0 V2302.0004", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GP versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS400 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900M-STND-C01 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS940GF toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100 (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300 V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900 (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900G versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RMC8388NC V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RMC8388NC V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GF toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2288 V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC PNI versions ant\u00e9rieures \u00e0 V2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2488NC V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC product family V7 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000TNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS400NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i803NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS910W versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416NCv2 V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100PF toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS1600T versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC product family V5.0 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300PNC V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300P V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RMC30 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS920W versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416PF toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i803 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM APE1808 toutes versions utilis\u00e9es avec Nozomi Guardian / CMC versions V22.6.3 \u00e0 23.1.0sans le dernier correctif de s\u00e9curit\u00e9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications Mendix bas\u00e9es sur Mendix 7.x versions ant\u00e9rieures \u00e0 V7.23.37", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG908C versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications Mendix bas\u00e9es sur Mendix 9.x versions ant\u00e9rieures \u00e0 V9.24.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG920P V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900W versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS401NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC product family V5.1 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC224 (6GK5224-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900MNC-STND-XX toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC MV500 family versions ant\u00e9rieures \u00e0 V3.3.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RST916P versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS401 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2488 V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS910 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416v2 V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2488F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GNC(32M) V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RST2228 versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416P versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2288NC V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M2100F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications Mendix bas\u00e9es sur Mendix 8.x versions ant\u00e9rieures \u00e0 V8.18.27", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RP110NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100P versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M969F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GPF toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG907R versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i802 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M969 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG920PNC V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS920L versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900MNC-STND-XX-C01 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900G (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap V2301 versions ant\u00e9rieures \u00e0 V2301.0003", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100NC(32M) V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2288 V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG920PNC V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000H versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RMC8388 V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG910C versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG909R versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416PNCv2 V4.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS910NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC product family V6 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416Pv2 V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i800NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS930LNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RMC8388 V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS neo versions ant\u00e9rieures \u00e0 V4.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900M-STND-XX versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS910L versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i802NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS1600FNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100PNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS400F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Studio Pro 7 versions ant\u00e9rieures \u00e0 V7.23.37", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000A versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900L versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS920LNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000T versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RMC30NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS versions ant\u00e9rieures \u00e0 V10.4.4, les vuln\u00e9rabilit\u00e9s CVE-2023-43505, CVE-2023-46601 ne seront pas corrig\u00e9es par l\u0027\u00e9diteur", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GNC(32M) V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2488 V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000ANC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC216 (6GK5216-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS930L versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSL910NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300 V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300PNC V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM i801 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Studio Pro 9 versions ant\u00e9rieures \u00e0 V9.24.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M2100NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416NCv2 V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900M-GETS-C01 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS969NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP208 (6GK5208-0HA00-2AS6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900G (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Tecnomatix Plant Simulation V2201 versions ant\u00e9rieures \u00e0 V2201.0010", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS8000HNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap V2306 versions ant\u00e9rieures \u00e0 V2306.0001", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RP110 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900 (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100 (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M969NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSL910 versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS1600F versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900NC(32M) V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204 (6GK5204-0BA00-2GF2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300NC V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900MNC-GETS-XX toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS930W versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM M2200NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416v2 V5.X versions ant\u00e9rieures \u00e0 V5.6.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS900GPNC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS1600 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS940G versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 4 7SJ66 versions ant\u00e9rieures \u00e0 V4.41", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2300F toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS1600NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2) versions ant\u00e9rieures \u00e0 V4.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2100NC(32M) V5.X toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RS416NC toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM RSG2200 versions ant\u00e9rieures \u00e0 V4.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2023-24895", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24895" }, { "name": "CVE-2023-0216", "url": "https://www.cve.org/CVERecord?id=CVE-2023-0216" }, { "name": "CVE-2020-35460", "url": "https://www.cve.org/CVERecord?id=CVE-2020-35460" }, { "name": "CVE-2023-0401", "url": "https://www.cve.org/CVERecord?id=CVE-2023-0401" }, { "name": "CVE-2023-33135", "url": "https://www.cve.org/CVERecord?id=CVE-2023-33135" }, { "name": "CVE-2023-1530", "url": "https://www.cve.org/CVERecord?id=CVE-2023-1530" }, { "name": "CVE-2023-22669", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22669" }, { "name": "CVE-2023-44321", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44321" }, { "name": "CVE-2023-3935", "url": "https://www.cve.org/CVERecord?id=CVE-2023-3935" }, { "name": "CVE-2023-46096", "url": "https://www.cve.org/CVERecord?id=CVE-2023-46096" }, { "name": "CVE-2023-44317", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44317" }, { "name": "CVE-2022-4304", "url": "https://www.cve.org/CVERecord?id=CVE-2022-4304" }, { "name": "CVE-2023-38072", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38072" }, { "name": "CVE-2023-24897", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24897" }, { "name": "CVE-2022-44792", "url": "https://www.cve.org/CVERecord?id=CVE-2022-44792" }, { "name": "CVE-2023-3817", "url": "https://www.cve.org/CVERecord?id=CVE-2023-3817" }, { "name": "CVE-2023-38075", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38075" }, { "name": "CVE-2019-12256", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12256" }, { "name": "CVE-2023-35788", "url": "https://www.cve.org/CVERecord?id=CVE-2023-35788" }, { "name": "CVE-2022-28809", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28809" }, { "name": "CVE-2023-24936", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24936" }, { "name": "CVE-2023-38073", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38073" }, { "name": "CVE-2023-46097", "url": "https://www.cve.org/CVERecord?id=CVE-2023-46097" }, { "name": "CVE-2019-12258", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12258" }, { "name": "CVE-2020-25020", "url": "https://www.cve.org/CVERecord?id=CVE-2020-25020" }, { "name": "CVE-2022-4203", "url": "https://www.cve.org/CVERecord?id=CVE-2022-4203" }, { "name": "CVE-2022-44793", "url": "https://www.cve.org/CVERecord?id=CVE-2022-44793" }, { "name": "CVE-2023-33128", "url": "https://www.cve.org/CVERecord?id=CVE-2023-33128" }, { "name": "CVE-2019-12259", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12259" }, { "name": "CVE-2023-0217", "url": "https://www.cve.org/CVERecord?id=CVE-2023-0217" }, { "name": "CVE-2023-44320", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44320" }, { "name": "CVE-2022-39158", "url": "https://www.cve.org/CVERecord?id=CVE-2022-39158" }, { "name": "CVE-2022-28808", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28808" }, { "name": "CVE-2019-12261", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12261" }, { "name": "CVE-2023-46099", "url": "https://www.cve.org/CVERecord?id=CVE-2023-46099" }, { "name": "CVE-2023-46590", "url": "https://www.cve.org/CVERecord?id=CVE-2023-46590" }, { "name": "CVE-2023-2932", "url": "https://www.cve.org/CVERecord?id=CVE-2023-2932" }, { "name": "CVE-2023-41033", "url": "https://www.cve.org/CVERecord?id=CVE-2023-41033" }, { "name": "CVE-2023-46098", "url": "https://www.cve.org/CVERecord?id=CVE-2023-46098" }, { "name": "CVE-2022-37434", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37434" }, { "name": "CVE-2021-20094", "url": "https://www.cve.org/CVERecord?id=CVE-2021-20094" }, { "name": "CVE-2022-28807", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28807" }, { "name": "CVE-2023-38071", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38071" }, { "name": "CVE-2023-45794", "url": "https://www.cve.org/CVERecord?id=CVE-2023-45794" }, { "name": "CVE-2019-12263", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12263" }, { "name": "CVE-2021-20093", "url": "https://www.cve.org/CVERecord?id=CVE-2021-20093" }, { "name": "CVE-2023-44319", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44319" }, { "name": "CVE-2023-46601", "url": "https://www.cve.org/CVERecord?id=CVE-2023-46601" }, { "name": "CVE-2023-32032", "url": "https://www.cve.org/CVERecord?id=CVE-2023-32032" }, { "name": "CVE-2022-4450", "url": "https://www.cve.org/CVERecord?id=CVE-2022-4450" }, { "name": "CVE-2023-2650", "url": "https://www.cve.org/CVERecord?id=CVE-2023-2650" }, { "name": "CVE-2022-47522", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47522" }, { "name": "CVE-2023-38070", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38070" }, { "name": "CVE-2022-23095", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23095" }, { "name": "CVE-2023-44322", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44322" }, { "name": "CVE-2023-29245", "url": "https://www.cve.org/CVERecord?id=CVE-2023-29245" }, { "name": "CVE-2023-43503", "url": "https://www.cve.org/CVERecord?id=CVE-2023-43503" }, { "name": "CVE-2019-12260", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12260" }, { "name": "CVE-2022-23218", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23218" }, { "name": "CVE-2023-28260", "url": "https://www.cve.org/CVERecord?id=CVE-2023-28260" }, { "name": "CVE-2023-43505", "url": "https://www.cve.org/CVERecord?id=CVE-2023-43505" }, { "name": "CVE-2023-38074", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38074" }, { "name": "CVE-2019-12262", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12262" }, { "name": "CVE-2023-29331", "url": "https://www.cve.org/CVERecord?id=CVE-2023-29331" }, { "name": "CVE-2019-12255", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12255" }, { "name": "CVE-2023-44374", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44374" }, { "name": "CVE-2023-43504", "url": "https://www.cve.org/CVERecord?id=CVE-2023-43504" }, { "name": "CVE-2023-0933", "url": "https://www.cve.org/CVERecord?id=CVE-2023-0933" }, { "name": "CVE-2023-2567", "url": "https://www.cve.org/CVERecord?id=CVE-2023-2567" }, { "name": "CVE-2023-32649", "url": "https://www.cve.org/CVERecord?id=CVE-2023-32649" }, { "name": "CVE-2022-41032", "url": "https://www.cve.org/CVERecord?id=CVE-2022-41032" }, { "name": "CVE-2023-4863", "url": "https://www.cve.org/CVERecord?id=CVE-2023-4863" }, { "name": "CVE-2023-21808", "url": "https://www.cve.org/CVERecord?id=CVE-2023-21808" }, { "name": "CVE-2023-2931", "url": "https://www.cve.org/CVERecord?id=CVE-2023-2931" }, { "name": "CVE-2023-2975", "url": "https://www.cve.org/CVERecord?id=CVE-2023-2975" }, { "name": "CVE-2022-30184", "url": "https://www.cve.org/CVERecord?id=CVE-2022-30184" }, { "name": "CVE-2019-12265", "url": "https://www.cve.org/CVERecord?id=CVE-2019-12265" }, { "name": "CVE-2023-44373", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44373" }, { "name": "CVE-2023-3446", "url": "https://www.cve.org/CVERecord?id=CVE-2023-3446" }, { "name": "CVE-2022-23219", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23219" }, { "name": "CVE-2023-38076", "url": "https://www.cve.org/CVERecord?id=CVE-2023-38076" }, { "name": "CVE-2023-41032", "url": "https://www.cve.org/CVERecord?id=CVE-2023-41032" }, { "name": "CVE-2023-33126", "url": "https://www.cve.org/CVERecord?id=CVE-2023-33126" }, { "name": "CVE-2023-44318", "url": "https://www.cve.org/CVERecord?id=CVE-2023-44318" }, { "name": "CVE-2023-22670", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22670" } ], "initial_release_date": "2023-11-14T00:00:00", "last_revision_date": "2023-11-14T00:00:00", "links": [], "reference": "CERTFR-2023-AVI-0935", "revisions": [ { "description": "Version initiale", "revision_date": "2023-11-14T00:00:00.000000" } ], "risks": [ { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" }, { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un\nd\u00e9ni de service \u00e0 distance et une ex\u00e9cution de code arbitraire \u00e0\ndistance.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-617233 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-292063.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-268517 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-084182.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-197270 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-787941.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-099606 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-625850.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-137900 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-137900.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-456933 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-456933.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-787941 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-084182 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-887122.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-887122 du 08 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-150063.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-150063 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-268517.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-699386 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-197270.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-292063 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-617233.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-625850 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-457702 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-099606.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-478780 du 14 novembre 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-478780.html" } ] }
cnvd-2022-51434
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-429204.html
Name | ['SIEMENS JT2Go <13.3.0.5', 'Siemens Teamcenter Visualization 12.4', 'Siemens Teamcenter Visualization 13.2', 'Siemens Teamcenter Visualization <13.3.0.5', 'Siemens Teamcenter Visualization 14.0'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2022-28808" } }, "description": "JT2Go\u662f\u4e00\u4e2a3D JT\u67e5\u770b\u5de5\u5177\uff0c\u5141\u8bb8\u7528\u6237\u67e5\u770bJT\u3001PDF\u3001Solid Edge\u3001PLM XML\u4ee5\u53ca\u53ef\u7528\u7684JT\u3001VFZ\u3001CGM\u548cTIF\u6570\u636e\u3002Teamcenter Visualization\u4f7f\u4f01\u4e1a\u80fd\u591f\u901a\u8fc7\u5168\u9762\u7684\u53ef\u89c6\u5316\u89e3\u51b3\u65b9\u6848\u7cfb\u5217\u589e\u5f3a\u5176\u4ea7\u54c1\u751f\u547d\u5468\u671f\u7ba1\u7406 (PLM) \u73af\u5883\u3002\u8be5\u8f6f\u4ef6\u4f7f\u4f01\u4e1a\u7528\u6237\u80fd\u591f\u5728\u5355\u4e00\u73af\u5883\u4e2d\u8bbf\u95ee\u6587\u6863\u30012D\u56fe\u7eb8\u548c3D\u6a21\u578b\u3002\n\nSiemens JT2Go and Teamcenter Visualization\u5b58\u5728\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-429204.html", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2022-51434", "openTime": "2022-07-14", "patchDescription": "JT2Go\u662f\u4e00\u4e2a3D JT\u67e5\u770b\u5de5\u5177\uff0c\u5141\u8bb8\u7528\u6237\u67e5\u770bJT\u3001PDF\u3001Solid Edge\u3001PLM XML\u4ee5\u53ca\u53ef\u7528\u7684JT\u3001VFZ\u3001CGM\u548cTIF\u6570\u636e\u3002Teamcenter Visualization\u4f7f\u4f01\u4e1a\u80fd\u591f\u901a\u8fc7\u5168\u9762\u7684\u53ef\u89c6\u5316\u89e3\u51b3\u65b9\u6848\u7cfb\u5217\u589e\u5f3a\u5176\u4ea7\u54c1\u751f\u547d\u5468\u671f\u7ba1\u7406 (PLM) \u73af\u5883\u3002\u8be5\u8f6f\u4ef6\u4f7f\u4f01\u4e1a\u7528\u6237\u80fd\u591f\u5728\u5355\u4e00\u73af\u5883\u4e2d\u8bbf\u95ee\u6587\u6863\u30012D\u56fe\u7eb8\u548c3D\u6a21\u578b\u3002\r\n\r\nSiemens JT2Go and Teamcenter Visualization\u5b58\u5728\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens JT2Go and Teamcenter Visualization\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff08CNVD-2022-51434\uff09\u7684\u8865\u4e01", "products": { "product": [ "SIEMENS JT2Go \u003c13.3.0.5", "Siemens Teamcenter Visualization 12.4", "Siemens Teamcenter Visualization 13.2", "Siemens Teamcenter Visualization \u003c13.3.0.5", "Siemens Teamcenter Visualization 14.0" ] }, "referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-429204.html", "serverity": "\u9ad8", "submitTime": "2022-07-14", "title": "Siemens JT2Go and Teamcenter Visualization\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff08CNVD-2022-51434\uff09" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.