Action not permitted
Modal body text goes here.
CVE-2022-28807
Vulnerability from cvelistv5
Published
2022-07-17 22:18
Modified
2024-08-03 06:03
Severity ?
EPSS score ?
Summary
An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it's opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://www.opendesign.com/security-advisories | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.opendesign.com/security-advisories | Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:03:53.076Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.opendesign.com/security-advisories" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-17T22:18:34", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.opendesign.com/security-advisories" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28807", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-28807", "datePublished": "2022-07-17T22:18:34", "dateReserved": "2022-04-08T00:00:00", "dateUpdated": "2024-08-03T06:03:53.076Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-28807\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-07-17T23:15:08.530\",\"lastModified\":\"2024-11-21T06:57:58.100\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado un problema en Open Design Alliance Drawings SDK anterior a 2023.2. Se presenta una vulnerabilidad de lectura fuera de l\u00edmites cuando es renderizado un archivo .dwg despu\u00e9s de abrirlo en el modo de recuperaci\u00f3n. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2023.2\",\"matchCriteriaId\":\"989FF002-B5A3-4339-B60F-B9EEB3FBDF1D\"}]}]}],\"references\":[{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
ghsa-2x96-8c2q-x6fv
Vulnerability from github
Published
2022-07-18 00:00
Modified
2022-07-26 00:01
Severity ?
Details
An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it's opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2022-28807" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-07-17T23:15:00Z", "severity": "HIGH" }, "details": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GHSA-2x96-8c2q-x6fv", "modified": "2022-07-26T00:01:06Z", "published": "2022-07-18T00:00:32Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-28807" }, { "type": "WEB", "url": "https://www.opendesign.com/security-advisories" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
icsa-23-320-09
Vulnerability from csaf_cisa
Published
2023-11-14 00:00
Modified
2023-11-14 00:00
Summary
Siemens COMOS
Notes
Summary
COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations.
Siemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. \n\nSiemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-137900.json" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-137900.html" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf" }, { "category": "self", "summary": "SSA-137900: Multiple Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-137900.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2023-11-14T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-320-09", "initial_release_date": "2023-11-14T00:00:00Z", "revision_history": [ { "date": "2023-11-14T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV10.4.4", "product": { "name": "COMOS", "product_id": "1" } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "COMOS", "product_id": "2" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-25020", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "summary", "text": "MPXJ through 8.1.3 allows XXE attacks. This affects the GanttProjectReader and PhoenixReader components.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-25020" }, { "cve": "CVE-2020-35460", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "common/InputStreamHelper.java in Packwood MPXJ before 8.3.5 allows directory traversal in the zip stream handler flow, leading to the writing of files to arbitrary locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-35460" }, { "cve": "CVE-2022-23095", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.12.1 mishandles the loading of JPG files. Unchecked input data from a crafted JPG file leads to memory corruption. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23095" }, { "cve": "CVE-2022-28807", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable\r\nto an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28807" }, { "cve": "CVE-2022-28808", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading DWG files in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28808" }, { "cve": "CVE-2022-28809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading a DWG file with invalid vertex number in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28809" }, { "cve": "CVE-2023-0933", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Integer overflow in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0933" }, { "cve": "CVE-2023-1530", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-1530" }, { "cve": "CVE-2023-2931", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-2931" }, { "cve": "CVE-2023-2932", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Use after free in PDFium library used in COMOS allowed a remote attacker to potentially exploit heap corruption via a crafted PDF file.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-2932" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer overflow while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer overflow while parsing specially crafted DXF files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V10.4.4 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-43503", "cwe": { "id": "CWE-319", "name": "Cleartext Transmission of Sensitive Information" }, "notes": [ { "category": "summary", "text": "Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "For CVE-2023-43503, update to V10.4.4 or later version and update the COMOS database to version 25. (See \u201cData maintenance: Modifying the version\u201d in the user manual. Warning: After the update, the database cannot be used by older COMOS versions)", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-43503" }, { "cve": "CVE-2023-43504", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "For CVE-2023-43504, delete ptmcast.exe from bin folder of COMOS installation directory. Installations from COMOS V10.4.4 or later version does not contain ptmcast.exe", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-43504" }, { "cve": "CVE-2023-43505", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application lacks proper access controls in SMB shares. This could allow an attacker to access files that the user should not have access to.", "title": "Summary" } ], "product_status": { "known_affected": [ "2" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "2" ] }, { "category": "mitigation", "details": "CVE-2023-43505, CVE-2023-46601: Use an application server like Citrix which builds an additional layer of access control around COMOS. The file share with the documents folder and the database should be only accessible by the application server. You can find further recommendations in the COMOS manual \u201cSecurityrelevant configuration\u201d in COMOS documentation (\nhttps://support.industry.siemens.com/cs/document/109823629/)", "product_ids": [ "2" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2" ] } ], "title": "CVE-2023-43505" }, { "cve": "CVE-2023-46601", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application lacks proper access controls in making the SQLServer connection. This could allow an attacker to query the database directly to access information that the user should not have access to.", "title": "Summary" } ], "product_status": { "known_affected": [ "2" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure all files imported into COMOS originate from a trusted source and transmitted are over secure channels", "product_ids": [ "2" ] }, { "category": "mitigation", "details": "CVE-2023-43505, CVE-2023-46601: Use an application server like Citrix which builds an additional layer of access control around COMOS. The file share with the documents folder and the database should be only accessible by the application server. You can find further recommendations in the COMOS manual \u201cSecurityrelevant configuration\u201d in COMOS documentation (\nhttps://support.industry.siemens.com/cs/document/109823629/)", "product_ids": [ "2" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2" ] } ], "title": "CVE-2023-46601" } ] }
icsa-22-195-11
Vulnerability from csaf_cisa
Published
2022-07-14 00:00
Modified
2022-07-14 00:00
Summary
Open Design Alliance Drawings SDK
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of this vulnerability could allow a user to open a malicious DWG file that could lead to the application crashing or to an arbitrary code execution.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
United States
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
These vulnerabilities are not exploitable remotely.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow a user to open a malicious DWG file that could lead to the application crashing or to an arbitrary code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States", "title": "Company headquarters location" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "These vulnerabilities are not exploitable remotely.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-429204.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-195-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-195-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-195-11 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-195-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-429204.pdf" }, { "category": "external", "summary": "SSA-429204 Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-429204.txt" } ], "title": "Open Design Alliance Drawings SDK", "tracking": { "current_release_date": "2022-07-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-195-11", "initial_release_date": "2022-07-14T00:00:00.000000Z", "revision_history": [ { "date": "2022-07-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V13.3.0.5", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V12.4.0.15", "product": { "name": "Teamcenter Visualization V12.4", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V12.4" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.9", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.3.0.5", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V14.0.0.2", "product": { "name": "Teamcenter Visualization V14.0", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.0" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-28807", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable\r\nto an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28807" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28807" }, { "cve": "CVE-2022-28808", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading DWG files in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28808" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28808" }, { "cve": "CVE-2022-28809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (all versions prior to 2023.3) is vulnerable to an out-of-bounds read when reading a DWG file with invalid vertex number in a recovery mode. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28809" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and\nTeamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.15 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.9 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.5 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.2 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "title": "CVE-2022-28809" } ] }
gsd-2022-28807
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it's opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-28807", "description": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2022-28807" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-28807" ], "details": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2022-28807", "modified": "2023-12-13T01:19:34.222644Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28807", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2023.2", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28807" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2023.2. An Out-of-Bounds Read vulnerability exists when rendering a .dwg file after it\u0027s opened in the recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.opendesign.com/security-advisories" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-07-25T15:13Z", "publishedDate": "2022-07-17T23:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.