cve-2019-10929
Vulnerability from cvelistv5
Published
2019-08-13 18:55
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.us-cert.gov/ics/advisories/icsa-19-344-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-344-04 | Third Party Advisory, US Government Resource |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.230Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V20.8" } ] }, { "product": "SIMATIC HMI Panel (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.1" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V20.8" } ] }, { "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC WinCC (TIA Portal)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC WinCC OA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P013" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC WinCC Runtime Professional", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "TIM 1531 IRC (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-327", "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:07", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10929", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC CP 1626", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V20.8" } ] } }, { "product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC NET PC Software V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Update 14" } ] } }, { "product_name": "SIMATIC NET PC Software V15", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.4.0" } ] } }, { "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.1" } ] } }, { "product_name": "SIMATIC S7-1500 Software Controller", "version": { "version_data": [ { "version_value": "All versions \u003c V20.8" } ] } }, { "product_name": "SIMATIC S7-PLCSIM Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC WinCC (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC WinCC OA", "version": { "version_data": [ { "version_value": "All versions \u003c V3.16 P013" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10929", "datePublished": "2019-08-13T18:55:57", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.230Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-10929\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-08-13T19:15:14.860\",\"lastModified\":\"2024-11-21T04:20:10.487\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC CP 1626 (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones anteriores a V20. 8), SIMATIC HMI Panel (incl. variantes SIPLUS) (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.4.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.8.1), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V20.8), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V3.0), SIMATIC STEP 7 (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 16 P013), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V16), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a V16), TIM 1531 IRC (incl. variantes de SIPLUS NET) (Todas las versiones anteriores a V2.1). Los dispositivos afectados contienen una vulnerabilidad de elusi\u00f3n de la protecci\u00f3n de mensajes debido a ciertas propiedades en el c\u00e1lculo utilizado para la protecci\u00f3n de la integridad. Esto podr\u00eda permitir a un atacante en posici\u00f3n de Man-in-the-Middle modificar el tr\u00e1fico de red enviado por el puerto 102/tcp a los dispositivos afectados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFA8109D-F938-4FE3-9885-831D2D0FE058\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8AED132-C4CF-4C2E-B826-DFAE745256FD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C59DF55E-2F4F-4BF1-B02F-05916BC863D4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"30E3491F-8F4A-4C7D-960D-073AA41DB4D6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"621AC3EC-6DA3-4AA6-9100-0407EC8370E6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3871C0C9-C65E-4E0B-9CA8-75E60066297F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"9F22D58C-444F-4179-B84F-24D57F4971EB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07849777-92E7-41D2-9128-F8D20DE15391\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"985A67F3-9799-4D30-B049-619456280DA4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE17584A-BF7A-48B8-A9CB-477663766C63\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"6A5E0374-939D-4C5E-B721-5AD8A3329387\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC4698CF-F935-4707-BA91-7E3650C7956C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"FF7EA085-2297-4BA0-96AB-2A2EBE0BEFAF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"232279DE-CF1C-4A3C-886D-B4CE3F104F09\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF4F6EA7-68BD-4A9D-8DDC-1D802EA7905B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE0BA68C-EB57-49CE-94A8-E7905AB79824\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33F882B8-EEDF-489E-9933-37EFC0AAC356\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"822894D4-96D5-4BDC-A698-D31262BCF422\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9E8D52B-CDB3-4E26-A0C4-592CCBFBB827\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2E24A4C-AC13-4382-BDF6-E13878FED4DC\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"744B5953-511F-42CA-80A0-DBE36A6AA144\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA1684C0-4B7C-44A0-9F16-5F8121654397\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C9A3749-B092-4F92-8140-55F10A03A5DB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"E6D968D9-2A64-4E1C-824F-6508AEC6789D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"F96AD4B7-105A-4D60-9026-E5C6389F3C73\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.15\",\"matchCriteriaId\":\"4C3580BA-45F0-4A01-925F-D56B0BA058F7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"84D652E6-23F7-4EB6-AE66-69662E191559\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:patch_12:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F0B76B7-FCB4-4831-BD00-AF29FD4606B2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*\",\"matchCriteriaId\":\"29B1F502-8A3A-4C07-90D2-CE5EB06CB573\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*\",\"matchCriteriaId\":\"0384FFF2-F577-4FFC-8A84-5682771D1BC1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2DA2E87-7B96-4B6B-90F9-C22B138B441B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"581EA284-EDD6-4EA5-96B2-67904D1D9DC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_tim_1531_irc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.1\",\"matchCriteriaId\":\"95DEFB00-96A2-460F-8B59-A288FD154FDC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_tim_1531_irc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AEFDF765-44F4-45CB-8A28-FD7D355310DA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_panel_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE91BB69-3E42-4110-B49B-D53DB894E140\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_panel:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"35CA808F-891D-4E10-A87A-68440D0BE0CB\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-344-04\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-344-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.