GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2026-40715 (GCVE-0-2026-40715)

Vulnerability from cvelistv5 – Published: 2026-06-02 16:14 – Updated: 2026-06-03 03:56
VLAI
Summary
Dell ThinOS 10, versions prior to ThinOS10 2602_10.0765, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-02 00:00 UTC
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version CPE status
Dell ThinOS 10 Affected: 0 , < 2602_10.0765_T10 (semver)
guessed Create a notification for this product.
Date Public
2026-05-20 16:12
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40715",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-02T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-03T03:56:06.228Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThinOS 10",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2602_10.0765_T10",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank Brandon Schreiber for reporting this issue."
        }
      ],
      "datePublic": "2026-05-20T16:12:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell ThinOS 10, versions prior to ThinOS10 2602_10.0765, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation."
            }
          ],
          "value": "Dell ThinOS 10, versions prior to ThinOS10 2602_10.0765, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-02T16:14:12.841Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000463678/dsa-2026-214"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-40715",
    "datePublished": "2026-06-02T16:14:12.841Z",
    "dateReserved": "2026-04-15T05:04:31.837Z",
    "dateUpdated": "2026-06-03T03:56:06.228Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-40715",
      "date": "2026-09-17",
      "epss": "0.001",
      "percentile": "0.00969"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-40715\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2026-06-02T17:16:29.773\",\"lastModified\":\"2026-07-22T19:10:00.120\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell ThinOS 10, versions prior to ThinOS10 2602_10.0765, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation.\"},{\"lang\":\"es\",\"value\":\"Dell ThinOS 10, versiones anteriores a ThinOS10 2602_10.0765, contienen una vulnerabilidad de control de acceso inadecuado. Un atacante con privilegios bajos y acceso local podr\u00eda potencialmente explotar esta vulnerabilidad, lo que llevar\u00eda a una escalada de privilegios.\"}],\"affected\":[{\"source\":\"security_alert@emc.com\",\"affectedData\":[{\"vendor\":\"Dell\",\"product\":\"ThinOS 10\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2602_10.0765_T10\",\"versionType\":\"semver\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-06-02T00:00:00+00:00\",\"id\":\"CVE-2026-40715\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:thinos:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2602_10.0765\",\"matchCriteriaId\":\"24F986D3-8849-4466-A749-870298E8EF25\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000463678/dsa-2026-214\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2026-06-05T19:14:04+00:00",
      "cve": "CVE-2026-40715",
      "id": "CVE-2026-40715",
      "initial_release_date": "2026-05-20T16:12:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2026-40715",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-40715.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-40715\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-06-02T17:36:32.509220Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-06-02T17:36:35.011Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Dell would like to thank Brandon Schreiber for reporting this issue.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"ThinOS 10\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2602_10.0765_T10\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-05-20T16:12:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000463678/dsa-2026-214\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.2\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell ThinOS 10, versions prior to ThinOS10 2602_10.0765, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell ThinOS 10, versions prior to ThinOS10 2602_10.0765, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284: Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2026-06-02T16:14:12.841Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-40715\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-03T03:56:06.228Z\", \"dateReserved\": \"2026-04-15T05:04:31.837Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2026-06-02T16:14:12.841Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…