GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-44103 (GCVE-0-2024-44103)

Vulnerability from cvelistv5 – Published: 2024-09-10 20:39 – Updated: 2025-06-12 17:04
VLAI
Summary
DLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-11 00:00 UTC
CWE
Impacted products
Vendor Product Version CPE status
Ivanti Workspace Control Unaffected: 10.19.0.0 (custom)
guessed Create a notification for this product.
ivanti automation Unaffected: 0 , < 10.18.99.0 (custom)
    cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "automation",
            "vendor": "ivanti",
            "versions": [
              {
                "lessThan": "10.18.99.0",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-44103",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-11T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-12T03:55:35.127Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Workspace Control",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "10.19.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges. \u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "DLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-426",
              "description": "CWE-426 Untrusted Search Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-12T17:04:53.415Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-Ivanti-Workspace-Control-IWC"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-44103",
    "datePublished": "2024-09-10T20:39:40.204Z",
    "dateReserved": "2024-08-20T14:55:35.616Z",
    "dateUpdated": "2025-06-12T17:04:53.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-44103",
      "date": "2026-09-17",
      "epss": "0.00245",
      "percentile": "0.15989"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:ivanti:workspace_control:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "21D83B80-CA53-4122-864F-7CD27A212A4A",
                  "versionEndExcluding": "10.18.99.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "DLL hijacking in the management console of Ivanti Workspace Control version 10.18.0.0 and below allows a local authenticated attacker to escalate their privileges."
        },
        {
          "lang": "es",
          "value": "El secuestro de DLL en la consola de administraci\u00f3n de Ivanti Workspace Control versi\u00f3n 10.18.0.0 y anteriores permite que un atacante autenticado local escale sus privilegios."
        }
      ],
      "id": "CVE-2024-44103",
      "lastModified": "2024-09-18T17:18:39.040",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.0,
            "impactScore": 6.0,
            "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2024-09-10T21:15:13.547",
      "references": [
        {
          "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-Ivanti-Workspace-Control-IWC"
        }
      ],
      "sourceIdentifier": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-426"
            }
          ],
          "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-426"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "affected",
                "product": "Workspace Control",
                "vendor": "Ivanti",
                "versions": [
                  {
                    "status": "unaffected",
                    "version": "10.19.0.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "affected",
                "product": "automation",
                "vendor": "ivanti",
                "versions": [
                  {
                    "lessThan": "10.18.99.0",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:ivanti:workspace_control:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "21D83B80-CA53-4122-864F-7CD27A212A4A",
                    "versionEndExcluding": "10.18.99.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "DLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges."
          },
          {
            "lang": "es",
            "value": "El secuestro de DLL en la consola de administraci\u00f3n de Ivanti Workspace Control versi\u00f3n 10.18.0.0 y anteriores permite que un atacante autenticado local escale sus privilegios."
          }
        ],
        "id": "CVE-2024-44103",
        "lastModified": "2026-06-17T07:52:18.847",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.0,
              "impactScore": 6.0,
              "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-44103",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-11T00:00:00+00:00",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-09-10T21:15:13.547",
        "references": [
          {
            "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://forums.ivanti.com/s/article/Security-Advisory-Ivanti-Workspace-Control-IWC"
          }
        ],
        "sourceIdentifier": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-426"
              }
            ],
            "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-426"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-06-12T18:10:13+00:00",
      "cve": "CVE-2024-44103",
      "id": "CVE-2024-44103",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-44103",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-44103.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "affected",
                "product": "automation",
                "vendor": "ivanti",
                "versions": [
                  {
                    "lessThan": "10.18.99.0",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-44103",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-11T14:51:47.846989Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-11T14:52:15.567Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Workspace Control",
              "vendor": "Ivanti",
              "versions": [
                {
                  "status": "unaffected",
                  "version": "10.19.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges. \u0026nbsp;\u003c/span\u003e"
                }
              ],
              "value": "DLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-426",
                  "description": "CWE-426 Untrusted Search Path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-12T17:04:53.415Z",
            "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
            "shortName": "ivanti"
          },
          "references": [
            {
              "url": "https://forums.ivanti.com/s/article/Security-Advisory-Ivanti-Workspace-Control-IWC"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "assignerShortName": "ivanti",
        "cveId": "CVE-2024-44103",
        "datePublished": "2024-09-10T20:39:40.204Z",
        "dateReserved": "2024-08-20T14:55:35.616Z",
        "dateUpdated": "2025-06-12T17:04:53.415Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…