CVE-2024-22443 (GCVE-0-2024-22443)
Vulnerability from cvelistv5 – Published: 2024-07-24 15:08 – Updated: 2024-08-01 22:43
VLAI
Summary
A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise.
Severity
7.2 (High)
CWE
- CWE-1321 - Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hewlett Packard Enterprise | HPE Aruba Networking EdgeConnect SD-WAN Orchestrator |
Affected:
EdgeConnect SD-WAN Orchestrator 9.4.x: Orchestrator 9.4.1 (all builds) and below , ≤ <=9.4.1
(semver)
Affected: EdgeConnect SD-WAN Orchestrator 9.3.x: Orchestrator 9.3.2 (all builds) and below , ≤ <=9.3.2 (semver) Affected: EdgeConnect SD-WAN Orchestrator 9.2.x: Orchestrator 9.2.9 (all builds) and below , ≤ <=9.2.9 (semver) Affected: EdgeConnect SD-WAN Orchestrator 9.1.x: Orchestrator 9.1.9 (all builds) and below , ≤ <=9.1.9 (semver) |
Date Public
2024-07-24 13:57
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.2.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "edgeconnect_sd-wan_orchestrator",
"vendor": "arubanetworks",
"versions": [
{
"lessThanOrEqual": "9.2.9",
"status": "affected",
"version": "9.2.0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.3.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "edgeconnect_sd-wan_orchestrator",
"vendor": "arubanetworks",
"versions": [
{
"lessThanOrEqual": "9.3.2",
"status": "affected",
"version": "9.3.0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.1.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "edgeconnect_sd-wan_orchestrator",
"vendor": "arubanetworks",
"versions": [
{
"lessThanOrEqual": "9.1.9",
"status": "affected",
"version": "9.1.0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.4.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "edgeconnect_sd-wan_orchestrator",
"vendor": "arubanetworks",
"versions": [
{
"lessThanOrEqual": "9.4.1",
"status": "affected",
"version": "9.4.0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22443",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-24T19:28:56.823854Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1321",
"description": "CWE-1321 Improperly Controlled Modification of Object Prototype Attributes (\u0027Prototype Pollution\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T19:29:09.760Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.951Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE Aruba Networking EdgeConnect SD-WAN Orchestrator",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"lessThanOrEqual": "\u003c=9.4.1",
"status": "affected",
"version": "EdgeConnect SD-WAN Orchestrator 9.4.x: Orchestrator 9.4.1 (all builds) and below",
"versionType": "semver"
},
{
"lessThanOrEqual": "\u003c=9.3.2",
"status": "affected",
"version": "EdgeConnect SD-WAN Orchestrator 9.3.x: Orchestrator 9.3.2 (all builds) and below",
"versionType": "semver"
},
{
"lessThanOrEqual": "\u003c=9.2.9",
"status": "affected",
"version": "EdgeConnect SD-WAN Orchestrator 9.2.x: Orchestrator 9.2.9 (all builds) and below",
"versionType": "semver"
},
{
"lessThanOrEqual": "\u003c=9.1.9",
"status": "affected",
"version": "EdgeConnect SD-WAN Orchestrator 9.1.x: Orchestrator 9.1.9 (all builds) and below",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Daniel Jensen (@dozernz)"
}
],
"datePublic": "2024-07-24T13:57:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise."
}
],
"value": "A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T15:08:07.150Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2024-22443",
"datePublished": "2024-07-24T15:08:07.150Z",
"dateReserved": "2024-01-10T15:24:39.967Z",
"dateUpdated": "2024-08-01T22:43:34.951Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-22443",
"date": "2026-05-29",
"epss": "0.00795",
"percentile": "0.74262"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.1.0\", \"versionEndExcluding\": \"9.1.10\", \"matchCriteriaId\": \"7BA8228A-2E28-4530-AA20-2DEBB9BBE65B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.2.0\", \"versionEndExcluding\": \"9.2.10\", \"matchCriteriaId\": \"6C3CFB16-DA18-46DF-9AA5-34E86F6D3CA3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.3.0\", \"versionEndExcluding\": \"9.3.3\", \"matchCriteriaId\": \"C9FCF925-3E4D-43C7-A524-008FADCF97A3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.4.0\", \"versionEndExcluding\": \"9.4.2\", \"matchCriteriaId\": \"3FDE31DF-800F-4F99-8632-F5CD3A52B062\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la interfaz de administraci\\u00f3n basada en web de EdgeConnect SD-WAN Orchestrator podr\\u00eda permitir que un atacante remoto autenticado lleve a cabo un prototipo de ataque de contaminaci\\u00f3n del lado del servidor. La explotaci\\u00f3n exitosa de esta vulnerabilidad podr\\u00eda permitir a un atacante ejecutar comandos arbitrarios en el sistema operativo subyacente, lo que podr\\u00eda comprometer completamente el sistema.\"}]",
"id": "CVE-2024-22443",
"lastModified": "2024-11-21T08:56:18.113",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"security-alert@hpe.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
"published": "2024-07-24T15:15:11.370",
"references": "[{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-1321\"}]}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-1321\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-22443\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2024-07-24T15:15:11.370\",\"lastModified\":\"2024-11-21T08:56:18.113\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web de EdgeConnect SD-WAN Orchestrator podr\u00eda permitir que un atacante remoto autenticado lleve a cabo un prototipo de ataque de contaminaci\u00f3n del lado del servidor. La explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda permitir a un atacante ejecutar comandos arbitrarios en el sistema operativo subyacente, lo que podr\u00eda comprometer completamente el sistema.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-alert@hpe.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1321\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1321\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.1.0\",\"versionEndExcluding\":\"9.1.10\",\"matchCriteriaId\":\"7BA8228A-2E28-4530-AA20-2DEBB9BBE65B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.2.0\",\"versionEndExcluding\":\"9.2.10\",\"matchCriteriaId\":\"6C3CFB16-DA18-46DF-9AA5-34E86F6D3CA3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.3.0\",\"versionEndExcluding\":\"9.3.3\",\"matchCriteriaId\":\"C9FCF925-3E4D-43C7-A524-008FADCF97A3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.4.0\",\"versionEndExcluding\":\"9.4.2\",\"matchCriteriaId\":\"3FDE31DF-800F-4F99-8632-F5CD3A52B062\"}]}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T22:43:34.951Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-22443\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-24T19:28:56.823854Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.2.0:*:*:*:*:*:*:*\"], \"vendor\": \"arubanetworks\", \"product\": \"edgeconnect_sd-wan_orchestrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"9.2.9\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.3.0:*:*:*:*:*:*:*\"], \"vendor\": \"arubanetworks\", \"product\": \"edgeconnect_sd-wan_orchestrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.3.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"9.3.2\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.1.0:*:*:*:*:*:*:*\"], \"vendor\": \"arubanetworks\", \"product\": \"edgeconnect_sd-wan_orchestrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.1.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"9.1.9\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.4.0:*:*:*:*:*:*:*\"], \"vendor\": \"arubanetworks\", \"product\": \"edgeconnect_sd-wan_orchestrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"9.4.1\"}], \"defaultStatus\": \"unaffected\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1321\", \"description\": \"CWE-1321 Improperly Controlled Modification of Object Prototype Attributes (\u0027Prototype Pollution\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-24T19:28:47.146Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Daniel Jensen (@dozernz)\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise\", \"product\": \"HPE Aruba Networking EdgeConnect SD-WAN Orchestrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"EdgeConnect SD-WAN Orchestrator 9.4.x: Orchestrator 9.4.1 (all builds) and below\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c=9.4.1\"}, {\"status\": \"affected\", \"version\": \"EdgeConnect SD-WAN Orchestrator 9.3.x: Orchestrator 9.3.2 (all builds) and below\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c=9.3.2\"}, {\"status\": \"affected\", \"version\": \"EdgeConnect SD-WAN Orchestrator 9.2.x: Orchestrator 9.2.9 (all builds) and below\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c=9.2.9\"}, {\"status\": \"affected\", \"version\": \"EdgeConnect SD-WAN Orchestrator 9.1.x: Orchestrator 9.1.9 (all builds) and below\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c=9.1.9\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-07-24T13:57:00.000Z\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04672en_us\u0026docLocale=en_US\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A vulnerability in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise.\", \"base64\": false}]}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2024-07-24T15:08:07.150Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-22443\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T22:43:34.951Z\", \"dateReserved\": \"2024-01-10T15:24:39.967Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2024-07-24T15:08:07.150Z\", \"assignerShortName\": \"hpe\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…