GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-11248 (GCVE-0-2024-11248)

Vulnerability from cvelistv5 – Published: 2024-11-15 17:00 – Updated: 2024-11-15 19:30
VLAI
Title
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow
Summary
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-15 19:29 UTC
CWE
References
URL Tags
https://vuldb.com/?id.284684 vdb-entrytechnical-description
https://vuldb.com/?ctiid.284684 signaturepermissions-required
https://vuldb.com/?submit.443204 third-party-advisory
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version CPE status
Tenda AC10 Affected: 16.03.10.13
guessed Create a notification for this product.
tenda ac10_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11248",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-15T19:29:37.983327Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-15T19:30:31.322Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hand_king (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Durch Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-15T17:00:12.864Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-284684 | Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.284684"
        },
        {
          "name": "VDB-284684 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.284684"
        },
        {
          "name": "Submit #443204 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.443204"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-15T08:40:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11248",
    "datePublished": "2024-11-15T17:00:12.864Z",
    "dateReserved": "2024-11-15T07:35:05.406Z",
    "dateUpdated": "2024-11-15T19:30:31.322Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-11248",
      "date": "2026-09-17",
      "epss": "0.0126",
      "percentile": "0.68183"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "es",
          "value": "Se ha detectado una vulnerabilidad en Tenda AC10 16.03.10.13 que se ha clasificado como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetRebootTimer del archivo /goform/SetSysAutoRebbotCfg. La manipulaci\u00f3n del argumento rebootTime provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse."
        }
      ],
      "id": "CVE-2024-11248",
      "lastModified": "2024-11-19T21:51:57.467",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "automatable": "NOT_DEFINED",
              "availabilityRequirements": "NOT_DEFINED",
              "baseScore": 8.7,
              "baseSeverity": "HIGH",
              "confidentialityRequirements": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirements": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
              "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
              "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
              "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
              "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "recovery": "NOT_DEFINED",
              "safety": "NOT_DEFINED",
              "subsequentSystemAvailability": "NONE",
              "subsequentSystemConfidentiality": "NONE",
              "subsequentSystemIntegrity": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnerabilityResponseEffort": "NOT_DEFINED",
              "vulnerableSystemAvailability": "HIGH",
              "vulnerableSystemConfidentiality": "HIGH",
              "vulnerableSystemIntegrity": "HIGH"
            },
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-11-15T17:15:19.580",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?ctiid.284684"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?id.284684"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?submit.443204"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            },
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "AC10",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "16.03.10.13"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac10_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "16.03.10.13"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
          },
          {
            "lang": "es",
            "value": "Se ha detectado una vulnerabilidad en Tenda AC10 16.03.10.13 que se ha clasificado como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetRebootTimer del archivo /goform/SetSysAutoRebbotCfg. La manipulaci\u00f3n del argumento rebootTime provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse."
          }
        ],
        "id": "CVE-2024-11248",
        "lastModified": "2026-06-17T06:57:23.650",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-11248",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-15T19:29:37.983327Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-11-15T17:15:19.580",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?ctiid.284684"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?id.284684"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?submit.443204"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Product"
            ],
            "url": "https://www.tenda.com.cn/"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              },
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T22:08:43+00:00",
      "cve": "CVE-2024-11248",
      "id": "CVE-2024-11248",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-11248.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac10_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "16.03.10.13"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-11248",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-15T19:29:37.983327Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-15T19:30:26.705Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hand_king (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Durch Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-15T17:00:12.864Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-284684 | Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.284684"
            },
            {
              "name": "VDB-284684 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.284684"
            },
            {
              "name": "Submit #443204 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.443204"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-11-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-11-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-11-15T08:40:15.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-11248",
        "datePublished": "2024-11-15T17:00:12.864Z",
        "dateReserved": "2024-11-15T07:35:05.406Z",
        "dateUpdated": "2024-11-15T19:30:31.322Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…