Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    2277 vulnerabilities by tenda

    CVE-2026-11557 (GCVE-0-2026-11557)

    Vulnerability from nvd – Published: 2026-06-08 18:15 – Updated: 2026-06-08 19:52
    VLAI
    Title
    Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow
    Summary
    A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F451 Affected: 1.0.0.7
    Affected: 1.0.0.9
        cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11557",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T19:52:15.831128Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T19:52:29.251Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F451",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7"
                },
                {
                  "status": "affected",
                  "version": "1.0.0.9"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T18:15:10.637Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369167 | Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369167"
            },
            {
              "name": "VDB-369167 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369167/cti"
            },
            {
              "name": "CVE-2026-11557 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11557"
            },
            {
              "name": "Submit #836477 | Tenda Tenda F451 Wireless Router V1.0.0.7, V1.0.0.9 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836477"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/fromNatlimit/fromNatlimit.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T08:00:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11557",
        "datePublished": "2026-06-08T18:15:10.637Z",
        "dateReserved": "2026-06-08T05:55:39.465Z",
        "dateUpdated": "2026-06-08T19:52:29.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11556 (GCVE-0-2026-11556)

    Vulnerability from nvd – Published: 2026-06-08 18:00 – Updated: 2026-06-09 14:35
    VLAI
    Title
    Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection
    Summary
    A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F451 Affected: 1.0.0.7
    Affected: 1.0.0.9
        cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11556",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-09T14:33:10.240378Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T14:35:15.927Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F451",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7"
                },
                {
                  "status": "affected",
                  "version": "1.0.0.9"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T18:00:15.317Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369166 | Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369166"
            },
            {
              "name": "VDB-369166 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369166/cti"
            },
            {
              "name": "CVE-2026-11556 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11556"
            },
            {
              "name": "Submit #836476 | Tenda Tenda F451 Wireless Router V1.0.0.7, V1.0.0.9 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836476"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWriteFacMac2/formWriteFacMac.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T08:00:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11556",
        "datePublished": "2026-06-08T18:00:15.317Z",
        "dateReserved": "2026-06-08T05:55:33.297Z",
        "dateUpdated": "2026-06-09T14:35:15.927Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11553 (GCVE-0-2026-11553)

    Vulnerability from nvd – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
    VLAI
    Title
    Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    zhihua xie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11553",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T18:49:04.954919Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T18:49:14.135Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zhihua xie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T17:15:11.855Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369163"
            },
            {
              "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369163/cti"
            },
            {
              "name": "CVE-2026-11553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11553"
            },
            {
              "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836778"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T07:48:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11553",
        "datePublished": "2026-06-08T17:15:11.855Z",
        "dateReserved": "2026-06-08T05:43:31.214Z",
        "dateUpdated": "2026-06-08T18:49:14.135Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11528 (GCVE-0-2026-11528)

    Vulnerability from nvd – Published: 2026-06-08 15:15 – Updated: 2026-06-09 14:35
    VLAI
    Title
    Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow
    Summary
    A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC18 Affected: 15.03.05.05
        cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11528",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-09T14:27:07.795609Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T14:35:55.593Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.05"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T15:15:12.614Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369145 | Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369145"
            },
            {
              "name": "VDB-369145 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369145/cti"
            },
            {
              "name": "CVE-2026-11528 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11528"
            },
            {
              "name": "Submit #836474 | Tenda Tenda AC18 Wireless Router  V15.03.05.05 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836474"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/getRebootStatus/getRebootStatus.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T21:47:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11528",
        "datePublished": "2026-06-08T15:15:12.614Z",
        "dateReserved": "2026-06-07T19:42:14.647Z",
        "dateUpdated": "2026-06-09T14:35:55.593Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11524 (GCVE-0-2026-11524)

    Vulnerability from nvd – Published: 2026-06-08 15:00 – Updated: 2026-06-09 15:26
    VLAI
    Title
    Tenda W20E Web Management modifyWifiFilterRules stack-based overflow
    Summary
    A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11524",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-09T15:25:13.664719Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T15:26:03.032Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T15:00:16.713Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369144 | Tenda W20E Web Management modifyWifiFilterRules stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369144"
            },
            {
              "name": "VDB-369144 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369144/cti"
            },
            {
              "name": "CVE-2026-11524 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11524"
            },
            {
              "name": "Submit #836478 | Tenda Tenda W20E Enterprise Router  V15.11.0.6 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836478"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWifiFilterRulesModify/modifyWifiFilterRules.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T18:12:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E Web Management modifyWifiFilterRules stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11524",
        "datePublished": "2026-06-08T15:00:16.713Z",
        "dateReserved": "2026-06-07T16:07:35.577Z",
        "dateUpdated": "2026-06-09T15:26:03.032Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11523 (GCVE-0-2026-11523)

    Vulnerability from nvd – Published: 2026-06-08 14:45 – Updated: 2026-06-08 16:36
    VLAI
    Title
    Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow
    Summary
    A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11523",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T16:35:00.338505Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:36:03.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T14:45:09.883Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369143 | Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369143"
            },
            {
              "name": "VDB-369143 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369143/cti"
            },
            {
              "name": "CVE-2026-11523 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11523"
            },
            {
              "name": "Submit #836471 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836471"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T18:11:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11523",
        "datePublished": "2026-06-08T14:45:09.883Z",
        "dateReserved": "2026-06-07T16:06:42.495Z",
        "dateUpdated": "2026-06-08T16:36:03.017Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11522 (GCVE-0-2026-11522)

    Vulnerability from nvd – Published: 2026-06-08 14:30 – Updated: 2026-06-08 15:52
    VLAI
    Title
    Tenda W20E setPortMirror formSetPortMirror stack-based overflow
    Summary
    A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11522",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T15:52:11.957984Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T15:52:25.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T14:30:11.465Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369142 | Tenda W20E setPortMirror formSetPortMirror stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369142"
            },
            {
              "name": "VDB-369142 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369142/cti"
            },
            {
              "name": "CVE-2026-11522 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11522"
            },
            {
              "name": "Submit #836469 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836469"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formSetPortMirror/portMirrorMirroredPorts.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T18:11:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E setPortMirror formSetPortMirror stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11522",
        "datePublished": "2026-06-08T14:30:11.465Z",
        "dateReserved": "2026-06-07T16:06:39.937Z",
        "dateUpdated": "2026-06-08T15:52:25.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11504 (GCVE-0-2026-11504)

    Vulnerability from nvd – Published: 2026-06-08 10:00 – Updated: 2026-06-08 12:57
    VLAI
    Title
    Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow
    Summary
    A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369124 vdb-entrytechnical-description
    https://vuldb.com/vuln/369124/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11504 third-party-advisory
    https://vuldb.com/submit/835649 third-party-advisory
    https://github.com/cve-a/moist/issues/2 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CX12L Affected: 16.03.53.12
        cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11504",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:57:07.691843Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:57:17.537Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wi-Fi Schedule Configuration Endpoint"
              ],
              "product": "CX12L",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.53.12"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T10:00:13.594Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369124 | Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369124"
            },
            {
              "name": "VDB-369124 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369124/cti"
            },
            {
              "name": "CVE-2026-11504 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11504"
            },
            {
              "name": "Submit #835649 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/835649"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/cve-a/moist/issues/2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T16:06:25.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11504",
        "datePublished": "2026-06-08T10:00:13.594Z",
        "dateReserved": "2026-06-07T14:01:17.439Z",
        "dateUpdated": "2026-06-08T12:57:17.537Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11503 (GCVE-0-2026-11503)

    Vulnerability from nvd – Published: 2026-06-08 09:45 – Updated: 2026-06-08 16:22
    VLAI
    Title
    Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369123 vdb-entrytechnical-description
    https://vuldb.com/vuln/369123/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11503 third-party-advisory
    https://vuldb.com/submit/835648 third-party-advisory
    https://github.com/cve-a/moist/issues/1 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CX12L Affected: 16.03.53.12
        cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11503",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:46:27.133276Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:19.524Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wi-Fi Configuration Endpoint"
              ],
              "product": "CX12L",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.53.12"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T09:45:12.620Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369123 | Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369123"
            },
            {
              "name": "VDB-369123 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369123/cti"
            },
            {
              "name": "CVE-2026-11503 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11503"
            },
            {
              "name": "Submit #835648 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/835648"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/cve-a/moist/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T16:06:22.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11503",
        "datePublished": "2026-06-08T09:45:12.620Z",
        "dateReserved": "2026-06-07T14:01:15.075Z",
        "dateUpdated": "2026-06-08T16:22:19.524Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11499 (GCVE-0-2026-11499)

    Vulnerability from nvd – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
    VLAI
    Title
    Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
    Summary
    A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369119 vdb-entrytechnical-description
    https://vuldb.com/vuln/369119/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
    https://vuldb.com/submit/834888 third-party-advisory
    https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:55:19.613788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:55:29.374Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T07:00:23.672Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369119"
            },
            {
              "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369119/cti"
            },
            {
              "name": "CVE-2026-11499 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11499"
            },
            {
              "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834888"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:28:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11499",
        "datePublished": "2026-06-08T07:00:23.672Z",
        "dateReserved": "2026-06-07T13:23:38.138Z",
        "dateUpdated": "2026-06-08T12:55:29.374Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11498 (GCVE-0-2026-11498)

    Vulnerability from nvd – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
    VLAI
    Title
    Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369118 vdb-entrytechnical-description
    https://vuldb.com/vuln/369118/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
    https://vuldb.com/submit/834887 third-party-advisory
    https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:47:31.920390Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:24.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T06:45:21.289Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369118"
            },
            {
              "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369118/cti"
            },
            {
              "name": "CVE-2026-11498 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11498"
            },
            {
              "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834887"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:27:15.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11498",
        "datePublished": "2026-06-08T06:45:21.289Z",
        "dateReserved": "2026-06-07T13:22:12.336Z",
        "dateUpdated": "2026-06-08T16:22:24.244Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11493 (GCVE-0-2026-11493)

    Vulnerability from nvd – Published: 2026-06-08 05:45 – Updated: 2026-06-08 13:30
    VLAI
    Title
    Tenda AC15 Samba smb.conf weak password
    Summary
    A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-521 - Weak Password Requirements
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC15 Affected: 15.03.05.19
        cpe:2.3:o:tenda:ac15_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    L-14 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11493",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T13:30:33.197769Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T13:30:41.606Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac15_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Samba"
              ],
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "L-14 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 2.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 4.3,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "Weak Password Requirements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T05:45:09.868Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369113 | Tenda AC15 Samba smb.conf weak password",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/369113"
            },
            {
              "name": "VDB-369113 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369113/cti"
            },
            {
              "name": "CVE-2026-11493 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11493"
            },
            {
              "name": "Submit #834818 | Tenda AC15 V15.03.05.19 Misconfiguration",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834818"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://www.notion.so/Tenda-AC15-V15-03-05-19-3671f5ba98908023b508dc0330624dcd?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T12:23:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC15 Samba smb.conf weak password"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11493",
        "datePublished": "2026-06-08T05:45:09.868Z",
        "dateReserved": "2026-06-07T10:18:43.938Z",
        "dateUpdated": "2026-06-08T13:30:41.606Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-10192 (GCVE-0-2026-10192)

    Vulnerability from nvd – Published: 2026-05-31 16:00 – Updated: 2026-06-01 12:29
    VLAI
    Title
    Tenda W12 httpd set_local_time_0 stack-based overflow
    Summary
    A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W12 Affected: 3.0.0.7(4763)
        cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    CookedMelon (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-10192",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-01T12:29:33.921006Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-01T12:29:51.172Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.0.7(4763)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CookedMelon (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-31T16:00:13.456Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-367473 | Tenda W12 httpd set_local_time_0 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/367473"
            },
            {
              "name": "VDB-367473 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/367473/cti"
            },
            {
              "name": "CVE-2026-10192 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-10192"
            },
            {
              "name": "Submit #820024 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/820024"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "http://cdn2.v50to.cc/set_local_time_0_overflow.zip"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-30T18:52:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W12 httpd set_local_time_0 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-10192",
        "datePublished": "2026-05-31T16:00:13.456Z",
        "dateReserved": "2026-05-30T16:45:18.912Z",
        "dateUpdated": "2026-06-01T12:29:51.172Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-10191 (GCVE-0-2026-10191)

    Vulnerability from nvd – Published: 2026-05-31 15:45 – Updated: 2026-06-01 15:24
    VLAI
    Title
    Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow
    Summary
    A vulnerability was determined in Tenda W12 3.0.0.7(4763). Impacted is the function cgiWifiMacFilterSet of the file /bin/httpd. This manipulation of the argument wifiMacFilterSet.macList.mac causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W12 Affected: 3.0.0.7(4763)
        cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    CookedMelon (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-10191",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-01T15:16:43.874685Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-01T15:24:11.577Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.0.7(4763)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CookedMelon (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda W12 3.0.0.7(4763). Impacted is the function cgiWifiMacFilterSet of the file /bin/httpd. This manipulation of the argument wifiMacFilterSet.macList.mac causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-31T15:45:14.535Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-367472 | Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/367472"
            },
            {
              "name": "VDB-367472 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/367472/cti"
            },
            {
              "name": "CVE-2026-10191 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-10191"
            },
            {
              "name": "Submit #820023 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/820023"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "http://cdn2.v50to.cc/cgiWifiMacFilterSet_overflow.zip"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-30T18:52:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-10191",
        "datePublished": "2026-05-31T15:45:14.535Z",
        "dateReserved": "2026-05-30T16:45:16.184Z",
        "dateUpdated": "2026-06-01T15:24:11.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-10190 (GCVE-0-2026-10190)

    Vulnerability from nvd – Published: 2026-05-31 15:30 – Updated: 2026-06-01 15:04
    VLAI
    Title
    Tenda W12 Web Management httpd cgiSysWebTimeoutSet denial of service
    Summary
    A vulnerability was found in Tenda W12 3.0.0.7(4763). This issue affects the function cgiSysWebTimeoutSet of the file /bin/httpd of the component Web Management Interface. The manipulation of the argument web_over_time results in denial of service. It is possible to launch the attack remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/367471 vdb-entrytechnical-description
    https://vuldb.com/vuln/367471/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-10190 third-party-advisory
    https://vuldb.com/submit/820022 third-party-advisory
    http://cdn2.v50to.cc/cgiSysWebTimeoutSet_dos.zip exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda W12 Affected: 3.0.0.7(4763)
        cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    CookedMelon (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-10190",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-01T15:04:47.302906Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-01T15:04:52.891Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/820022"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "W12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.0.7(4763)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CookedMelon (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda W12 3.0.0.7(4763). This issue affects the function cgiSysWebTimeoutSet of the file /bin/httpd of the component Web Management Interface. The manipulation of the argument web_over_time results in denial of service. It is possible to launch the attack remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-404",
                  "description": "Denial of Service",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-31T15:30:13.999Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-367471 | Tenda W12 Web Management httpd cgiSysWebTimeoutSet denial of service",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/367471"
            },
            {
              "name": "VDB-367471 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/367471/cti"
            },
            {
              "name": "CVE-2026-10190 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-10190"
            },
            {
              "name": "Submit #820022 | Tenda W12 V3.0.0.7(4763) Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/820022"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "http://cdn2.v50to.cc/cgiSysWebTimeoutSet_dos.zip"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-30T18:52:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W12 Web Management httpd cgiSysWebTimeoutSet denial of service"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-10190",
        "datePublished": "2026-05-31T15:30:13.999Z",
        "dateReserved": "2026-05-30T16:45:13.485Z",
        "dateUpdated": "2026-06-01T15:04:52.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-10189 (GCVE-0-2026-10189)

    Vulnerability from nvd – Published: 2026-05-31 15:00 – Updated: 2026-06-01 13:28
    VLAI
    Title
    Tenda W12 httpd cgiSysTimeInfoSet stack-based overflow
    Summary
    A vulnerability has been found in Tenda W12 3.0.0.7(4763). This vulnerability affects the function cgiSysTimeInfoSet of the file /bin/httpd. The manipulation of the argument sec leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W12 Affected: 3.0.0.7(4763)
        cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    CookedMelon (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-10189",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-01T13:28:26.403905Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-01T13:28:34.971Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.0.7(4763)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CookedMelon (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda W12 3.0.0.7(4763). This vulnerability affects the function cgiSysTimeInfoSet of the file /bin/httpd. The manipulation of the argument sec leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-31T15:00:14.812Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-367470 | Tenda W12 httpd cgiSysTimeInfoSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/367470"
            },
            {
              "name": "VDB-367470 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/367470/cti"
            },
            {
              "name": "CVE-2026-10189 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-10189"
            },
            {
              "name": "Submit #820021 | Tenda W12 V3.0.0.7(4763) stack",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/820021"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "http://cdn2.v50to.cc/cgiSysTimeInfoSet_overflow.zip"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-30T18:52:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W12 httpd cgiSysTimeInfoSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-10189",
        "datePublished": "2026-05-31T15:00:14.812Z",
        "dateReserved": "2026-05-30T16:45:10.724Z",
        "dateUpdated": "2026-06-01T13:28:34.971Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11557 (GCVE-0-2026-11557)

    Vulnerability from cvelistv5 – Published: 2026-06-08 18:15 – Updated: 2026-06-08 19:52
    VLAI
    Title
    Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow
    Summary
    A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F451 Affected: 1.0.0.7
    Affected: 1.0.0.9
        cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11557",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T19:52:15.831128Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T19:52:29.251Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F451",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7"
                },
                {
                  "status": "affected",
                  "version": "1.0.0.9"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T18:15:10.637Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369167 | Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369167"
            },
            {
              "name": "VDB-369167 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369167/cti"
            },
            {
              "name": "CVE-2026-11557 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11557"
            },
            {
              "name": "Submit #836477 | Tenda Tenda F451 Wireless Router V1.0.0.7, V1.0.0.9 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836477"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/fromNatlimit/fromNatlimit.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T08:00:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11557",
        "datePublished": "2026-06-08T18:15:10.637Z",
        "dateReserved": "2026-06-08T05:55:39.465Z",
        "dateUpdated": "2026-06-08T19:52:29.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11556 (GCVE-0-2026-11556)

    Vulnerability from cvelistv5 – Published: 2026-06-08 18:00 – Updated: 2026-06-09 14:35
    VLAI
    Title
    Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection
    Summary
    A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F451 Affected: 1.0.0.7
    Affected: 1.0.0.9
        cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11556",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-09T14:33:10.240378Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T14:35:15.927Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F451",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7"
                },
                {
                  "status": "affected",
                  "version": "1.0.0.9"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T18:00:15.317Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369166 | Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369166"
            },
            {
              "name": "VDB-369166 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369166/cti"
            },
            {
              "name": "CVE-2026-11556 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11556"
            },
            {
              "name": "Submit #836476 | Tenda Tenda F451 Wireless Router V1.0.0.7, V1.0.0.9 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836476"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWriteFacMac2/formWriteFacMac.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T08:00:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11556",
        "datePublished": "2026-06-08T18:00:15.317Z",
        "dateReserved": "2026-06-08T05:55:33.297Z",
        "dateUpdated": "2026-06-09T14:35:15.927Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11553 (GCVE-0-2026-11553)

    Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
    VLAI
    Title
    Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    zhihua xie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11553",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T18:49:04.954919Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T18:49:14.135Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zhihua xie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T17:15:11.855Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369163"
            },
            {
              "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369163/cti"
            },
            {
              "name": "CVE-2026-11553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11553"
            },
            {
              "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836778"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T07:48:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11553",
        "datePublished": "2026-06-08T17:15:11.855Z",
        "dateReserved": "2026-06-08T05:43:31.214Z",
        "dateUpdated": "2026-06-08T18:49:14.135Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11528 (GCVE-0-2026-11528)

    Vulnerability from cvelistv5 – Published: 2026-06-08 15:15 – Updated: 2026-06-09 14:35
    VLAI
    Title
    Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow
    Summary
    A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC18 Affected: 15.03.05.05
        cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11528",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-09T14:27:07.795609Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T14:35:55.593Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.05"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T15:15:12.614Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369145 | Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369145"
            },
            {
              "name": "VDB-369145 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369145/cti"
            },
            {
              "name": "CVE-2026-11528 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11528"
            },
            {
              "name": "Submit #836474 | Tenda Tenda AC18 Wireless Router  V15.03.05.05 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836474"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/getRebootStatus/getRebootStatus.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T21:47:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11528",
        "datePublished": "2026-06-08T15:15:12.614Z",
        "dateReserved": "2026-06-07T19:42:14.647Z",
        "dateUpdated": "2026-06-09T14:35:55.593Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11524 (GCVE-0-2026-11524)

    Vulnerability from cvelistv5 – Published: 2026-06-08 15:00 – Updated: 2026-06-09 15:26
    VLAI
    Title
    Tenda W20E Web Management modifyWifiFilterRules stack-based overflow
    Summary
    A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11524",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-09T15:25:13.664719Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T15:26:03.032Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T15:00:16.713Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369144 | Tenda W20E Web Management modifyWifiFilterRules stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369144"
            },
            {
              "name": "VDB-369144 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369144/cti"
            },
            {
              "name": "CVE-2026-11524 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11524"
            },
            {
              "name": "Submit #836478 | Tenda Tenda W20E Enterprise Router  V15.11.0.6 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836478"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWifiFilterRulesModify/modifyWifiFilterRules.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T18:12:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E Web Management modifyWifiFilterRules stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11524",
        "datePublished": "2026-06-08T15:00:16.713Z",
        "dateReserved": "2026-06-07T16:07:35.577Z",
        "dateUpdated": "2026-06-09T15:26:03.032Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11523 (GCVE-0-2026-11523)

    Vulnerability from cvelistv5 – Published: 2026-06-08 14:45 – Updated: 2026-06-08 16:36
    VLAI
    Title
    Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow
    Summary
    A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11523",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T16:35:00.338505Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:36:03.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T14:45:09.883Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369143 | Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369143"
            },
            {
              "name": "VDB-369143 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369143/cti"
            },
            {
              "name": "CVE-2026-11523 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11523"
            },
            {
              "name": "Submit #836471 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836471"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T18:11:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11523",
        "datePublished": "2026-06-08T14:45:09.883Z",
        "dateReserved": "2026-06-07T16:06:42.495Z",
        "dateUpdated": "2026-06-08T16:36:03.017Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11522 (GCVE-0-2026-11522)

    Vulnerability from cvelistv5 – Published: 2026-06-08 14:30 – Updated: 2026-06-08 15:52
    VLAI
    Title
    Tenda W20E setPortMirror formSetPortMirror stack-based overflow
    Summary
    A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    hacker128 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11522",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T15:52:11.957984Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T15:52:25.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hacker128 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T14:30:11.465Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369142 | Tenda W20E setPortMirror formSetPortMirror stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369142"
            },
            {
              "name": "VDB-369142 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369142/cti"
            },
            {
              "name": "CVE-2026-11522 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11522"
            },
            {
              "name": "Submit #836469 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836469"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formSetPortMirror/portMirrorMirroredPorts.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T18:11:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E setPortMirror formSetPortMirror stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11522",
        "datePublished": "2026-06-08T14:30:11.465Z",
        "dateReserved": "2026-06-07T16:06:39.937Z",
        "dateUpdated": "2026-06-08T15:52:25.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11504 (GCVE-0-2026-11504)

    Vulnerability from cvelistv5 – Published: 2026-06-08 10:00 – Updated: 2026-06-08 12:57
    VLAI
    Title
    Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow
    Summary
    A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369124 vdb-entrytechnical-description
    https://vuldb.com/vuln/369124/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11504 third-party-advisory
    https://vuldb.com/submit/835649 third-party-advisory
    https://github.com/cve-a/moist/issues/2 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CX12L Affected: 16.03.53.12
        cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11504",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:57:07.691843Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:57:17.537Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wi-Fi Schedule Configuration Endpoint"
              ],
              "product": "CX12L",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.53.12"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T10:00:13.594Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369124 | Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369124"
            },
            {
              "name": "VDB-369124 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369124/cti"
            },
            {
              "name": "CVE-2026-11504 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11504"
            },
            {
              "name": "Submit #835649 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/835649"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/cve-a/moist/issues/2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T16:06:25.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11504",
        "datePublished": "2026-06-08T10:00:13.594Z",
        "dateReserved": "2026-06-07T14:01:17.439Z",
        "dateUpdated": "2026-06-08T12:57:17.537Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11503 (GCVE-0-2026-11503)

    Vulnerability from cvelistv5 – Published: 2026-06-08 09:45 – Updated: 2026-06-08 16:22
    VLAI
    Title
    Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369123 vdb-entrytechnical-description
    https://vuldb.com/vuln/369123/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11503 third-party-advisory
    https://vuldb.com/submit/835648 third-party-advisory
    https://github.com/cve-a/moist/issues/1 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CX12L Affected: 16.03.53.12
        cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11503",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:46:27.133276Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:19.524Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wi-Fi Configuration Endpoint"
              ],
              "product": "CX12L",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.53.12"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T09:45:12.620Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369123 | Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369123"
            },
            {
              "name": "VDB-369123 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369123/cti"
            },
            {
              "name": "CVE-2026-11503 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11503"
            },
            {
              "name": "Submit #835648 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/835648"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/cve-a/moist/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T16:06:22.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11503",
        "datePublished": "2026-06-08T09:45:12.620Z",
        "dateReserved": "2026-06-07T14:01:15.075Z",
        "dateUpdated": "2026-06-08T16:22:19.524Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11499 (GCVE-0-2026-11499)

    Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
    VLAI
    Title
    Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
    Summary
    A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369119 vdb-entrytechnical-description
    https://vuldb.com/vuln/369119/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
    https://vuldb.com/submit/834888 third-party-advisory
    https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:55:19.613788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:55:29.374Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T07:00:23.672Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369119"
            },
            {
              "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369119/cti"
            },
            {
              "name": "CVE-2026-11499 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11499"
            },
            {
              "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834888"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:28:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11499",
        "datePublished": "2026-06-08T07:00:23.672Z",
        "dateReserved": "2026-06-07T13:23:38.138Z",
        "dateUpdated": "2026-06-08T12:55:29.374Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11498 (GCVE-0-2026-11498)

    Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
    VLAI
    Title
    Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369118 vdb-entrytechnical-description
    https://vuldb.com/vuln/369118/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
    https://vuldb.com/submit/834887 third-party-advisory
    https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    moist (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:47:31.920390Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:24.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T06:45:21.289Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369118"
            },
            {
              "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369118/cti"
            },
            {
              "name": "CVE-2026-11498 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11498"
            },
            {
              "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834887"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:27:15.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11498",
        "datePublished": "2026-06-08T06:45:21.289Z",
        "dateReserved": "2026-06-07T13:22:12.336Z",
        "dateUpdated": "2026-06-08T16:22:24.244Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11493 (GCVE-0-2026-11493)

    Vulnerability from cvelistv5 – Published: 2026-06-08 05:45 – Updated: 2026-06-08 13:30
    VLAI
    Title
    Tenda AC15 Samba smb.conf weak password
    Summary
    A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-521 - Weak Password Requirements
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC15 Affected: 15.03.05.19
        cpe:2.3:o:tenda:ac15_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    L-14 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11493",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T13:30:33.197769Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T13:30:41.606Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac15_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Samba"
              ],
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "L-14 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 2.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 4.3,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "Weak Password Requirements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T05:45:09.868Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369113 | Tenda AC15 Samba smb.conf weak password",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/369113"
            },
            {
              "name": "VDB-369113 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369113/cti"
            },
            {
              "name": "CVE-2026-11493 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11493"
            },
            {
              "name": "Submit #834818 | Tenda AC15 V15.03.05.19 Misconfiguration",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834818"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://www.notion.so/Tenda-AC15-V15-03-05-19-3671f5ba98908023b508dc0330624dcd?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T12:23:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC15 Samba smb.conf weak password"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11493",
        "datePublished": "2026-06-08T05:45:09.868Z",
        "dateReserved": "2026-06-07T10:18:43.938Z",
        "dateUpdated": "2026-06-08T13:30:41.606Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-10192 (GCVE-0-2026-10192)

    Vulnerability from cvelistv5 – Published: 2026-05-31 16:00 – Updated: 2026-06-01 12:29
    VLAI
    Title
    Tenda W12 httpd set_local_time_0 stack-based overflow
    Summary
    A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W12 Affected: 3.0.0.7(4763)
        cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    CookedMelon (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-10192",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-01T12:29:33.921006Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-01T12:29:51.172Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.0.7(4763)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CookedMelon (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-31T16:00:13.456Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-367473 | Tenda W12 httpd set_local_time_0 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/367473"
            },
            {
              "name": "VDB-367473 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/367473/cti"
            },
            {
              "name": "CVE-2026-10192 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-10192"
            },
            {
              "name": "Submit #820024 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/820024"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "http://cdn2.v50to.cc/set_local_time_0_overflow.zip"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-30T18:52:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W12 httpd set_local_time_0 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-10192",
        "datePublished": "2026-05-31T16:00:13.456Z",
        "dateReserved": "2026-05-30T16:45:18.912Z",
        "dateUpdated": "2026-06-01T12:29:51.172Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-10191 (GCVE-0-2026-10191)

    Vulnerability from cvelistv5 – Published: 2026-05-31 15:45 – Updated: 2026-06-01 15:24
    VLAI
    Title
    Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow
    Summary
    A vulnerability was determined in Tenda W12 3.0.0.7(4763). Impacted is the function cgiWifiMacFilterSet of the file /bin/httpd. This manipulation of the argument wifiMacFilterSet.macList.mac causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda W12 Affected: 3.0.0.7(4763)
        cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    CookedMelon (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-10191",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-01T15:16:43.874685Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-01T15:24:11.577Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.0.7(4763)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CookedMelon (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda W12 3.0.0.7(4763). Impacted is the function cgiWifiMacFilterSet of the file /bin/httpd. This manipulation of the argument wifiMacFilterSet.macList.mac causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-31T15:45:14.535Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-367472 | Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/367472"
            },
            {
              "name": "VDB-367472 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/367472/cti"
            },
            {
              "name": "CVE-2026-10191 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-10191"
            },
            {
              "name": "Submit #820023 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/820023"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "http://cdn2.v50to.cc/cgiWifiMacFilterSet_overflow.zip"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-30T18:52:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-10191",
        "datePublished": "2026-05-31T15:45:14.535Z",
        "dateReserved": "2026-05-30T16:45:16.184Z",
        "dateUpdated": "2026-06-01T15:24:11.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }