CVE-2022-32521 (GCVE-0-2022-32521)
Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2025-02-05 20:07- CWE-502 - Deserialization of Untrusted Data
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Data Center Expert |
Affected:
All , < V7.9.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:46:43.618Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-32521",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:33.537984Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:07:44.700Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V7.9.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-06-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-32521",
"datePublished": "2023-01-30T00:00:00.000Z",
"dateReserved": "2022-06-07T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:07:44.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-32521",
"date": "2026-05-29",
"epss": "0.01497",
"percentile": "0.81412"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:data_center_expert:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"7.9.0\", \"matchCriteriaId\": \"F98A808B-75E5-4CFC-85B4-53954C9FE818\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad CWE 502: deserializaci\\u00f3n de datos no confiables que podr\\u00eda permitir que el c\\u00f3digo se ejecute de forma remota en el servidor cuando se publican datos deserializados de manera insegura en el servidor web. Productos afectados: Data Center Expert (versiones anteriores a V7.9.0)\"}]",
"id": "CVE-2022-32521",
"lastModified": "2024-11-21T07:06:32.973",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
"published": "2023-01-30T23:15:10.547",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Release Notes\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Release Notes\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-502\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-32521\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-01-30T23:15:10.547\",\"lastModified\":\"2024-11-21T07:06:32.973\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE 502: deserializaci\u00f3n de datos no confiables que podr\u00eda permitir que el c\u00f3digo se ejecute de forma remota en el servidor cuando se publican datos deserializados de manera insegura en el servidor web. Productos afectados: Data Center Expert (versiones anteriores a V7.9.0)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-502\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:data_center_expert:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.9.0\",\"matchCriteriaId\":\"F98A808B-75E5-4CFC-85B4-53954C9FE818\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Release Notes\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Release Notes\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T07:46:43.618Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-32521\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-05T19:52:33.537984Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-05T19:52:34.981Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Data Center Expert\", \"versions\": [{\"status\": \"affected\", \"version\": \"All\", \"lessThan\": \"V7.9.0\", \"versionType\": \"custom\"}]}], \"datePublic\": \"2022-06-14T00:00:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-502\", \"description\": \"CWE-502 Deserialization of Untrusted Data\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-01-30T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-32521\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-05T20:07:44.700Z\", \"dateReserved\": \"2022-06-07T00:00:00.000Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-01-30T00:00:00.000Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
{
"CVSS 2.0": "AV:N/AC:H/Au:S/C:C/I:C/A:C",
"CVSS 3.0": "AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 7.9.1 (Data Center Expert)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\u0026_ga=2.232546783.1324274284.1656652886-288657633.1651119814",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "14.06.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "11.07.2022",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "11.07.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04262",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-32521",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Data Center Expert",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u043e\u0431 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0438 Schneider Electric Data Center Expert, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u0432 \u043f\u0430\u043c\u044f\u0442\u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u043e\u0432\u0435\u0440\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0412\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u0432 \u043f\u0430\u043c\u044f\u0442\u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u043e\u0432\u0435\u0440\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 (CWE-502)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u043e\u0431 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0438 Schneider Electric Data Center Expert \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u0432 \u043f\u0430\u043c\u044f\u0442\u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u043e\u0432\u0435\u0440\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04\u0026_ga=2.232546783.1324274284.1656652886-288657633.1651119814",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-502",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,1)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,1)"
}
FKIE_CVE-2022-32521
Vulnerability from fkie_nvd - Published: 2023-01-30 23:15 - Updated: 2024-11-21 07:068.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf&p_Doc_Ref=SEVD-2022-165-04 | Patch, Release Notes, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf&p_Doc_Ref=SEVD-2022-165-04 | Patch, Release Notes, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | data_center_expert | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:data_center_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F98A808B-75E5-4CFC-85B4-53954C9FE818",
"versionEndExcluding": "7.9.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE 502: deserializaci\u00f3n de datos no confiables que podr\u00eda permitir que el c\u00f3digo se ejecute de forma remota en el servidor cuando se publican datos deserializados de manera insegura en el servidor web. Productos afectados: Data Center Expert (versiones anteriores a V7.9.0)"
}
],
"id": "CVE-2022-32521",
"lastModified": "2024-11-21T07:06:32.973",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-01-30T23:15:10.547",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Release Notes",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Release Notes",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-502"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-VJ7V-2RFM-6P53
Vulnerability from github – Published: 2023-01-31 00:30 – Updated: 2023-02-07 21:30A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
{
"affected": [],
"aliases": [
"CVE-2022-32521"
],
"database_specific": {
"cwe_ids": [
"CWE-502"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-01-30T23:15:00Z",
"severity": "CRITICAL"
},
"details": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)",
"id": "GHSA-vj7v-2rfm-6p53",
"modified": "2023-02-07T21:30:23Z",
"published": "2023-01-31T00:30:18Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-32521"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2022-32521
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-32521",
"description": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)",
"id": "GSD-2022-32521"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-32521"
],
"details": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)",
"id": "GSD-2022-32521",
"modified": "2023-12-13T01:19:12.556743Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-06-14T07:00:00.000Z",
"ID": "CVE-2022-32521",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Data Center Expert",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "V7.9.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502 Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:data_center_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.9.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-32521"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04",
"refsource": "MISC",
"tags": [
"Patch",
"Release Notes",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-04-03T17:44Z",
"publishedDate": "2023-01-30T23:15Z"
}
}
}
SEVD-2022-165-04
Vulnerability from csaf_se - Published: 2022-06-14 18:30 - Updated: 2022-06-14 18:30A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party.
CWE-522 - Insufficiently Protected Credentials| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Data Center Expert 7.9.1
Schneider Electric / Data Center Expert
|
7.9.1 |
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party.
CWE-257 - Storing Passwords in a Recoverable Format| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Data Center Expert 7.9.1
Schneider Electric / Data Center Expert
|
7.9.1 |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party.
CWE-522 - Insufficiently Protected Credentials| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Data Center Expert 7.9.1
Schneider Electric / Data Center Expert
|
7.9.1 |
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Data Center Expert 7.9.1
Schneider Electric / Data Center Expert
|
7.9.1 |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Data Center Expert product.\r\nThe Data Center Expert product provides an efficient way for organizations to monitor and manage their company-wide multi-vendor physical infrastructure, including power, cooling, security and environmental.\r\nFailure to apply the remediations provided below may risk unauthorized access to a DCE instance, which could result in downtime or outage.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Data Center Expert - SEVD-2022-165-04 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-165-04.json"
},
{
"category": "self",
"summary": "Data Center Expert - SEVD-2022-165-04 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-165-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Data Center Expert",
"tracking": {
"current_release_date": "2022-06-14T18:30:00.000Z",
"generator": {
"date": "2022-06-16T17:56:15.212Z",
"engine": {
"name": "Secvisogram",
"version": "1.14.0"
}
},
"id": "SEVD-2022-165-04",
"initial_release_date": "2022-06-14T18:30:00.000Z",
"revision_history": [
{
"date": "2022-06-14T18:30:00.000Z",
"number": "1",
"summary": "Original Release"
},
{
"date": "2022-06-16T16:00:00.000Z",
"number": "2",
"summary": "Affected versions updated to include V7.9.0, remediation guidance updated for clarity."
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=7.9.0",
"product": {
"name": "Schneider Electric Data Center Expert version 7.9.0 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Data Center Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "7.9.1",
"product": {
"name": "Schneider Electric Data Center Expert 7.9.1",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Data Center Expert"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Tom Wyatt"
],
"organization": "Mimecast Ltd"
}
],
"cve": "CVE-2022-32518",
"cwe": {
"id": "CWE-522",
"name": "Insufficiently Protected Credentials"
},
"notes": [
{
"category": "description",
"text": "A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Data Center Expert V7.9.1 and newer includes fixes for these vulnerabilities. You can download the latest version on the EcoStruxure IT Entitlements Portal. If you do not have an EcoStruxure IT Entitlements account, please contact Customer Care Center. \r\n https://www.se.com/us/en/work/support/contacts.jsp \n Release Notes:\r https://dcimsupport.ecostruxureit.com/hc/en-us/articles/4517646198941-Data-Center-Expert-7-9-1-release-notes",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://download.struxureon.com/dce/upgrade/791/6SJA8N/index.html"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Leverage secure protocols wherever available (HTTPS)\r\n\u2022 Leverage certificates signed by an external and trusted CA\r\nFollow security hardening guidelines found in https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook."
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32518"
},
{
"acknowledgments": [
{
"names": [
"Tom Wyatt"
],
"organization": "Mimecast Ltd"
}
],
"cve": "CVE-2022-32519",
"cwe": {
"id": "CWE-257",
"name": "Storing Passwords in a Recoverable Format"
},
"notes": [
{
"category": "description",
"text": "A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Data Center Expert V7.9.1 and newer includes fixes for these vulnerabilities. You can download the latest version on the EcoStruxure IT Entitlements Portal. If you do not have an EcoStruxure IT Entitlements account, please contact Customer Care Center. \r\n https://www.se.com/us/en/work/support/contacts.jsp \n Release Notes:\r https://dcimsupport.ecostruxureit.com/hc/en-us/articles/4517646198941-Data-Center-Expert-7-9-1-release-notes",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://download.struxureon.com/dce/upgrade/791/6SJA8N/index.html"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Leverage secure protocols wherever available (HTTPS)\r\n\u2022 Leverage certificates signed by an external and trusted CA\r\nFollow security hardening guidelines found in https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook."
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32519"
},
{
"acknowledgments": [
{
"names": [
"Tom Wyatt"
],
"organization": "Mimecast Ltd"
}
],
"cve": "CVE-2022-32520",
"cwe": {
"id": "CWE-522",
"name": "Insufficiently Protected Credentials"
},
"notes": [
{
"category": "description",
"text": "A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Data Center Expert V7.9.1 and newer includes fixes for these vulnerabilities. You can download the latest version on the EcoStruxure IT Entitlements Portal. If you do not have an EcoStruxure IT Entitlements account, please contact Customer Care Center. \r\n https://www.se.com/us/en/work/support/contacts.jsp \n Release Notes:\r https://dcimsupport.ecostruxureit.com/hc/en-us/articles/4517646198941-Data-Center-Expert-7-9-1-release-notes",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://download.struxureon.com/dce/upgrade/791/6SJA8N/index.html"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Leverage secure protocols wherever available (HTTPS)\r\n\u2022 Leverage certificates signed by an external and trusted CA\r\nFollow security hardening guidelines found in https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook."
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32520"
},
{
"acknowledgments": [
{
"names": [
"Tom Wyatt"
],
"organization": "Mimecast Ltd"
}
],
"cve": "CVE-2022-32521",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"category": "description",
"text": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Data Center Expert V7.9.1 and newer includes fixes for these vulnerabilities. You can download the latest version on the EcoStruxure IT Entitlements Portal. If you do not have an EcoStruxure IT Entitlements account, please contact Customer Care Center. \r\n https://www.se.com/us/en/work/support/contacts.jsp \n Release Notes:\r https://dcimsupport.ecostruxureit.com/hc/en-us/articles/4517646198941-Data-Center-Expert-7-9-1-release-notes",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://download.struxureon.com/dce/upgrade/791/6SJA8N/index.html"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Leverage secure protocols wherever available (HTTPS)\r\n\u2022 Leverage certificates signed by an external and trusted CA\r\nFollow security hardening guidelines found in https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook."
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32521"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.