CERTFR-2022-AVI-546
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
Vendor | Product | Description | ||
---|---|---|---|---|
Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
Schneider Electric | N/A | Conext ComBox toutes versions | ||
Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
References
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Conext ComBox toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Versadac versions ant\u00e9rieures \u00e0 2.43", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2022-32524", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32524" }, { "name": "CVE-2022-24322", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24322" }, { "name": "CVE-2022-22731", "url": "https://www.cve.org/CVERecord?id=CVE-2022-22731" }, { "name": "CVE-2022-32514", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32514" }, { "name": "CVE-2020-35198", "url": "https://www.cve.org/CVERecord?id=CVE-2020-35198" }, { "name": "CVE-2022-32517", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32517" }, { "name": "CVE-2022-32526", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32526" }, { "name": "CVE-2022-32530", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32530" }, { "name": "CVE-2022-32748", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32748" }, { "name": "CVE-2022-22806", "url": "https://www.cve.org/CVERecord?id=CVE-2022-22806" }, { "name": "CVE-2022-32529", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32529" }, { "name": "CVE-2022-32513", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32513" }, { "name": "CVE-2022-32747", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32747" }, { "name": "CVE-2022-32523", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32523" }, { "name": "CVE-2022-32528", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32528" }, { "name": "CVE-2022-32516", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32516" }, { "name": "CVE-2022-32522", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32522" }, { "name": "CVE-2022-32527", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32527" }, { "name": "CVE-2022-32515", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32515" }, { "name": "CVE-2021-22697", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22697" }, { "name": "CVE-2022-0715", "url": "https://www.cve.org/CVERecord?id=CVE-2022-0715" }, { "name": "CVE-2022-0223", "url": "https://www.cve.org/CVERecord?id=CVE-2022-0223" }, { "name": "CVE-2022-32519", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32519" }, { "name": "CVE-2022-22805", "url": "https://www.cve.org/CVERecord?id=CVE-2022-22805" }, { "name": "CVE-2022-24323", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24323" }, { "name": "CVE-2022-32512", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32512" }, { "name": "CVE-2022-32518", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32518" }, { "name": "CVE-2022-22732", "url": "https://www.cve.org/CVERecord?id=CVE-2022-22732" }, { "name": "CVE-2020-28895", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28895" }, { "name": "CVE-2022-32520", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32520" }, { "name": "CVE-2022-32525", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32525" }, { "name": "CVE-2021-22698", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22698" }, { "name": "CVE-2022-32521", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32521" } ], "initial_release_date": "2022-06-15T00:00:00", "last_revision_date": "2022-08-19T00:00:00", "links": [], "reference": "CERTFR-2022-AVI-546", "revisions": [ { "description": "Version initiale", "revision_date": "2022-06-15T00:00:00.000000" }, { "description": "Modification de la version des produits IGSS Data Server", "revision_date": "2022-06-23T00:00:00.000000" }, { "description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.", "revision_date": "2022-08-19T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ] }
CVE-2022-32748 (GCVE-0-2022-32748)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-295 - Improper Certificate Validation
Summary
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | EcoStruxure™ Cybersecurity Admin Expert (CAE) |
Version: All < 2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:45.261Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32748", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:27.920514Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:07:23.903Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "EcoStruxure\u2122 Cybersecurity Admin Expert (CAE)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "2.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure\u2122 Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.9, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-295", "description": "CWE-295 Improper Certificate Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32748", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-09T00:00:00.000Z", "dateUpdated": "2025-02-05T20:07:23.903Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32747 (GCVE-0-2022-32747)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-290 - Authentication Bypass by Spoofing
Summary
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | EcoStruxure™ Cybersecurity Admin Expert (CAE) |
Version: All < 2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:45.120Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32747", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:30.511500Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:07:31.318Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "EcoStruxure\u2122 Cybersecurity Admin Expert (CAE)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "2.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure\u2122 Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-290", "description": "CWE-290 Authentication Bypass by Spoofing", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32747", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-09T00:00:00.000Z", "dateUpdated": "2025-02-05T20:07:31.318Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22698 (GCVE-0-2021-22698)
Vulnerability from cvelistv5
Published
2021-01-25 17:10
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Summary
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Power Build - Rapsody software V2.1.13 and prior. |
Version: EcoStruxure Power Build - Rapsody software V2.1.13 and prior. |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.283Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-187/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior." } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "\u00a0CWE-434: Unrestricted Upload of File with Dangerous Type\u00a0", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-18T17:58:44", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-187/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22698", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0", "version": { "version_data": [ { "version_value": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior." } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "\u00a0CWE-434: Unrestricted Upload of File with Dangerous Type\u00a0" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-187/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-187/" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22698", "datePublished": "2021-01-25T17:10:12", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.283Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-0223 (GCVE-0-2022-0223)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | EcoStruxure Power Commission |
Version: All < V2.22 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:18:42.838Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-0223", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:50:51.006673Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:09:13.271Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "EcoStruxure Power Commission", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.22", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-0223", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-01-13T00:00:00.000Z", "dateUpdated": "2025-02-05T20:09:13.271Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32519 (GCVE-0-2022-32519)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-257 - Storing Passwords in a Recoverable Format
Summary
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Data Center Expert |
Version: All < V7.9.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.451Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32519", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:40.472047Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:07:58.690Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.9.0", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-257", "description": "CWE-257 Storing Passwords in a Recoverable Format", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32519", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:07:58.690Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-24323 (GCVE-0-2022-24323)
Vulnerability from cvelistv5
Published
2022-03-09 23:05
Modified
2024-08-03 04:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
References
URL | Tags | |
---|---|---|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
Schneider Electric | EcoStruxure Process Expert |
Version: V2021 and prior |
|||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:07:02.566Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Process Expert", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "V2021 and prior" } ] }, { "product": "EcoStruxure Control Expert", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "V15.0 SP1 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-754", "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-09T23:05:14", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-24323", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Process Expert", "version": { "version_data": [ { "version_name": "V2021", "version_value": "and prior" } ] } }, { "product_name": "EcoStruxure Control Expert", "version": { "version_data": [ { "version_name": "V15.0 SP1", "version_value": "and prior" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-754 Improper Check for Unusual or Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-24323", "datePublished": "2022-03-09T23:05:14", "dateReserved": "2022-02-02T00:00:00", "dateUpdated": "2024-08-03T04:07:02.566Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32518 (GCVE-0-2022-32518)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-522 - Insufficiently Protected Credentials
Summary
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Data Center Expert |
Version: All < V7.9.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.372Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32518", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:43.556621Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:08:08.814Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.9.0", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522 Insufficiently Protected Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32518", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:08:08.814Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32525 (GCVE-0-2022-32525)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.391Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32525", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:54.213286Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:17:54.890Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32525", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:17:54.890Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32523 (GCVE-0-2022-32523)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32523", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:59.962055Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:18:12.115Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32523", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:18:12.115Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32514 (GCVE-0-2022-32514)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-287 - Improper Authentication
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schneider Electric | C-Bus Network Automation Controller, LSS5500NAC |
Version: All < V1.10.0 |
|||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.528Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32514", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:57:05.377109Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:18:27.254Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "C-Bus Network Automation Controller, LSS5500NAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Wiser for C-Bus Automation Controller, LSS5500SHAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "Clipsal C-Bus Network Automation Controller, 5500NAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "SpaceLogic C-Bus Application Controller, 5500AC2", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32514", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:18:27.254Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-0715 (GCVE-0-2022-0715)
Vulnerability from cvelistv5
Published
2022-03-09 19:30
Modified
2024-08-02 23:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-287 - Improper Authentication
Summary
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
References
URL | Tags | ||||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
Schneider Electric | APC Smart-UPS |
Version: SMT Series Version: SMC Series Version: SCL Series Version: SMX Series Version: SRT Series |
|||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:40:03.366Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APC Smart-UPS", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "SMT Series " }, { "status": "affected", "version": "SMC Series " }, { "status": "affected", "version": "SCL Series " }, { "status": "affected", "version": "SMX Series " }, { "status": "affected", "version": "SRT Series " } ] }, { "product": "SmartConnect ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "SMT Series " }, { "status": "affected", "version": "SMC Series" }, { "status": "affected", "version": "SMTL Series" }, { "status": "affected", "version": "SCL Series" }, { "status": "affected", "version": "SMX Series" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-28T16:25:27", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-0715", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APC Smart-UPS", "version": { "version_data": [ { "version_value": "SMT Series " }, { "version_value": "SMC Series " }, { "version_value": "SCL Series " }, { "version_value": "SMX Series " }, { "version_value": "SRT Series " } ] } }, { "product_name": "SmartConnect ", "version": { "version_data": [ { "version_value": "SMT Series " }, { "version_value": "SMC Series" }, { "version_value": "SMTL Series" }, { "version_value": "SCL Series" }, { "version_value": "SMX Series" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287 Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-0715", "datePublished": "2022-03-09T19:30:14", "dateReserved": "2022-02-21T00:00:00", "dateUpdated": "2024-08-02T23:40:03.366Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-22731 (GCVE-0-2022-22731)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | EcoStruxure Power Commission |
Version: All < V2.22 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:21:48.950Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-22731", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:50:48.313706Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:09:04.898Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "EcoStruxure Power Commission", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.22", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-22731", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-01-06T00:00:00.000Z", "dateUpdated": "2025-02-05T20:09:04.898Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-24322 (GCVE-0-2022-24322)
Vulnerability from cvelistv5
Published
2022-03-09 23:05
Modified
2024-08-03 04:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)
References
URL | Tags | |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | EcoStruxure Control Expert |
Version: V15.0 SP1 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:07:02.429Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "V15.0 SP1 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-09T23:05:13", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-24322", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert", "version": { "version_data": [ { "version_name": "V15.0 SP1", "version_value": "and prior" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-24322", "datePublished": "2022-03-09T23:05:13", "dateReserved": "2022-02-02T00:00:00", "dateUpdated": "2024-08-03T04:07:02.429Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32515 (GCVE-0-2022-32515)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Conext™ ComBox |
Version: All Versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.438Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32515", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:55:11.111660Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:08:34.356Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Conext\u2122 ComBox", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext\u2122 ComBox (All Versions)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-307", "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32515", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:08:34.356Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-22805 (GCVE-0-2022-22805)
Vulnerability from cvelistv5
Published
2022-03-09 19:30
Modified
2024-08-03 03:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
References
URL | Tags | ||||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | SmartConnect |
Version: SMT Series Version: SMC Series Version: SMTL Series Version: SCL Series Version: SMX Series |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:21:49.170Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SmartConnect ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "SMT Series " }, { "status": "affected", "version": "SMC Series" }, { "status": "affected", "version": "SMTL Series" }, { "status": "affected", "version": "SCL Series" }, { "status": "affected", "version": "SMX Series" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-28T16:25:28", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-22805", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SmartConnect ", "version": { "version_data": [ { "version_value": "SMT Series " }, { "version_value": "SMC Series" }, { "version_value": "SMTL Series" }, { "version_value": "SCL Series" }, { "version_value": "SMX Series" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-22805", "datePublished": "2022-03-09T19:30:16", "dateReserved": "2022-01-07T00:00:00", "dateUpdated": "2024-08-03T03:21:49.170Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-22806 (GCVE-0-2022-22806)
Vulnerability from cvelistv5
Published
2022-03-09 19:30
Modified
2024-08-03 03:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-294 - Authentication Bypass by Capture-replay
Summary
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
References
URL | Tags | ||||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | SmartConnect |
Version: SMT Series Version: SMC Series Version: SMTL Series Version: SCL Series Version: SMX Series |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:21:49.161Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SmartConnect ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "SMT Series " }, { "status": "affected", "version": "SMC Series" }, { "status": "affected", "version": "SMTL Series" }, { "status": "affected", "version": "SCL Series" }, { "status": "affected", "version": "SMX Series" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-294", "description": "CWE-294 Authentication Bypass by Capture-replay", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-28T16:25:29", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-22806", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SmartConnect ", "version": { "version_data": [ { "version_value": "SMT Series " }, { "version_value": "SMC Series" }, { "version_value": "SMTL Series" }, { "version_value": "SCL Series" }, { "version_value": "SMX Series" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-294 Authentication Bypass by Capture-replay" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-22806", "datePublished": "2022-03-09T19:30:17", "dateReserved": "2022-01-07T00:00:00", "dateUpdated": "2024-08-03T03:21:49.161Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32522 (GCVE-0-2022-32522)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32522", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:57:02.779533Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:18:19.794Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32522", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:18:19.794Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32529 (GCVE-0-2022-32529)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.368Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32529", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:45.508996Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:17:32.848Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32529", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:17:32.848Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32524 (GCVE-0-2022-32524)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.591Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32524", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:56.977758Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:18:04.323Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32524", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:18:04.323Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22697 (GCVE-0-2021-22697)
Vulnerability from cvelistv5
Published
2021-01-25 17:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Summary
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Power Build - Rapsody software V2.1.13 and prior. |
Version: EcoStruxure Power Build - Rapsody software V2.1.13 and prior. |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.429Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior." } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434: Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-18T17:58:40", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22697", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0", "version": { "version_data": [ { "version_value": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior." } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-434: Unrestricted Upload of File with Dangerous Type" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22697", "datePublished": "2021-01-25T17:09:26", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.429Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32520 (GCVE-0-2022-32520)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-522 - Insufficiently Protected Credentials
Summary
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Data Center Expert |
Version: All < V7.9.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.481Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32520", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:37.298872Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:07:51.671Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.9.0", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522 Insufficiently Protected Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32520", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:07:51.671Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32528 (GCVE-0-2022-32528)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause access to manipulate and read specific files in the IGSS project report directory,
potentially leading to a denial-of-service condition when an attacker sends specific messages.
Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:44.654Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-165-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32528", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:55:05.449223Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:07:38.231Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-13T18:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could\ncause access to manipulate and read specific files in the IGSS project report directory,\npotentially leading to a denial-of-service condition when an attacker sends specific messages.\n\n Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)\u003c/p\u003e" } ], "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could\ncause access to manipulate and read specific files in the IGSS project report directory,\npotentially leading to a denial-of-service condition when an attacker sends specific messages.\n\n Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-16T13:02:56.075Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-165-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32528", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:07:38.231Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32521 (GCVE-0-2022-32521)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Summary
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Data Center Expert |
Version: All < V7.9.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.618Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32521", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:33.537984Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:07:44.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.9.0", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-04" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32521", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:07:44.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32530 (GCVE-0-2022-32530)
Vulnerability from cvelistv5
Published
2022-06-24 13:00
Modified
2024-08-03 07:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Summary
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Geo SCADA Mobile |
Version: Build < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.411Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Geo SCADA Mobile", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "222", "status": "affected", "version": "Build", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-668", "description": "CWE-668 Exposure of Resource to Wrong Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-24T13:00:17", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-32530", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Geo SCADA Mobile", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "Build", "version_value": "222" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-668 Exposure of Resource to Wrong Sphere" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32530", "datePublished": "2022-06-24T13:00:17", "dateReserved": "2022-06-07T00:00:00", "dateUpdated": "2024-08-03T07:46:43.411Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32512 (GCVE-0-2022-32512)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | CanBRASS |
Version: All < V7.5.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.362Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-07" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32512", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:50:39.612446Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:08:42.167Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "CanBRASS", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.5.1", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-165-07" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32512", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:08:42.167Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32517 (GCVE-0-2022-32517)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1021 - Improper Restriction of Rendered UI Layers or Frames
Summary
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conext™ ComBox (All Versions)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Conext™ ComBox |
Version: All Versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.543Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32517", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:50:36.676159Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:08:16.694Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Conext\u2122 ComBox", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conext\u2122 ComBox (All Versions)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1021", "description": "CWE-1021: Improper Restriction of Rendered UI Layers or Frames", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32517", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:08:16.694Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-35198 (GCVE-0-2020-35198)
Vulnerability from cvelistv5
Published
2021-05-12 10:55
Modified
2024-08-04 17:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:02:06.842Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T23:22:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35198", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35198", "datePublished": "2021-05-12T10:55:47", "dateReserved": "2020-12-12T00:00:00", "dateUpdated": "2024-08-04T17:02:06.842Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-22732 (GCVE-0-2022-22732)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Summary
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | EcoStruxure Power Commission |
Version: All < V2.22 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:21:48.946Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-22732", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:50:45.469109Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:08:57.280Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "EcoStruxure Power Commission", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.22", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.9, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-668", "description": "CWE-668 Exposure of Resource to Wrong Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-22732", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-01-06T00:00:00.000Z", "dateUpdated": "2025-02-05T20:08:57.280Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32516 (GCVE-0-2022-32516)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Summary
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Conext™ ComBox |
Version: All Versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.469Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32516", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:55:08.252212Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:08:26.260Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Conext\u2122 ComBox", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352 Cross-Site Request Forgery (CSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32516", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:08:26.260Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32513 (GCVE-0-2022-32513)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-521 - Weak Password Requirements
Summary
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schneider Electric | C-Bus Network Automation Controller, LSS5500NAC |
Version: All < V1.10.0 |
|||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.427Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32513", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:57:08.047448Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:18:33.992Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "C-Bus Network Automation Controller, LSS5500NAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Wiser for C-Bus Automation Controller, LSS5500SHAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "Clipsal C-Bus Network Automation Controller, 5500NAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "SpaceLogic C-Bus Application Controller, 5500AC2", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-521", "description": "CWE-521 Weak Password Requirements", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32513", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:18:33.992Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32526 (GCVE-0-2022-32526)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.316Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32526", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:51.302669Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:17:48.134Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32526", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:17:48.134Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32527 (GCVE-0-2022-32527)
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2025-02-05 20:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | IGSS Data Server (IGSSdataServer.exe) |
Version: All < V15.0.0.22170 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:46:43.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-32527", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:48.578692Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:17:39.968Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "IGSS Data Server (IGSSdataServer.exe)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0.0.22170", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2022-06-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification_V2.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-32527", "datePublished": "2023-01-30T00:00:00.000Z", "dateReserved": "2022-06-07T00:00:00.000Z", "dateUpdated": "2025-02-05T20:17:39.968Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-28895 (GCVE-0-2020-28895)
Vulnerability from cvelistv5
Published
2021-02-03 15:16
Modified
2024-08-04 16:41
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:41:00.095Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "credits": [ { "lang": "en", "value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e" } ], "datePublic": "2020-12-14T00:00:00", "descriptions": [ { "lang": "en", "value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T23:22:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "source": { "discovery": "EXTERNAL" }, "title": "integer overflow in calloc", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-28895", "STATE": "PUBLIC", "TITLE": "integer overflow in calloc" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "credit": [ { "lang": "eng", "value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ] }, "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-28895", "datePublished": "2021-02-03T15:16:34", "dateReserved": "2020-11-17T00:00:00", "dateUpdated": "2024-08-04T16:41:00.095Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.