Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    24 vulnerabilities by silextechnology

    CVE-2026-32965 (GCVE-0-2026-32965)

    Vulnerability from nvd – Published: 2026-04-20 03:17 – Updated: 2026-04-20 14:23
    VLAI
    Summary
    Initialization of a resource with an insecure default vulnerability exists in SD-330AC and AMC Manager provided by silex technology, Inc. When the affected device is connected to the network with the initial (factory-default) configuration, the device can be configured with the null string password.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1188 - Initialization of a resource with an insecure default
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32965",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:23:30.435627Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:23:36.842Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Initialization of a resource with an insecure default vulnerability exists in SD-330AC and AMC Manager provided by silex technology, Inc. When the affected device is connected to the network with the initial (factory-default) configuration, the device can be configured with the null string password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1188",
                  "description": "Initialization of a resource with an insecure default",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:17:33.917Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32965",
        "datePublished": "2026-04-20T03:17:33.917Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:23:36.842Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32964 (GCVE-0-2026-32964)

    Vulnerability from nvd – Published: 2026-04-20 03:17 – Updated: 2026-04-20 14:08
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain an improper neutralization of CRLF sequences ('CRLF Injection') vulnerability. Processing some crafted configuration data may lead to arbitrary entries injected to the system configuration.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-93 - Improper neutralization of CRLF sequences ('CRLF Injection')
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32964",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:08:43.843940Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:08:52.559Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain an improper neutralization of CRLF sequences (\u0027CRLF Injection\u0027) vulnerability. Processing some crafted configuration data may lead to arbitrary entries injected to the system configuration."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-93",
                  "description": "Improper neutralization of CRLF sequences (\u0027CRLF Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:17:52.839Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32964",
        "datePublished": "2026-04-20T03:17:52.839Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:08:52.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32963 (GCVE-0-2026-32963)

    Vulnerability from nvd – Published: 2026-04-20 03:18 – Updated: 2026-04-20 14:04
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a reflected cross-site scripting vulnerability. When a user logs in to the affected device and access some crafted web page, arbitrary script may be executed on the user's browser.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Cross-site scripting (XSS)
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32963",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:04:14.460369Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:04:22.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a reflected cross-site scripting vulnerability. When a user logs in to the affected device and access some crafted web page, arbitrary script may be executed on the user\u0027s browser."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Cross-site scripting (XSS)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:07.431Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32963",
        "datePublished": "2026-04-20T03:18:07.431Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:04:22.838Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32962 (GCVE-0-2026-32962)

    Vulnerability from nvd – Published: 2026-04-20 03:18 – Updated: 2026-04-20 14:52
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue. The device configuration may be altered without authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32962",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:52:08.258698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:52:15.598Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue. The device configuration may be altered without authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing authentication for critical function",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:25.122Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32962",
        "datePublished": "2026-04-20T03:18:25.122Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:52:15.598Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32961 (GCVE-0-2026-32961)

    Vulnerability from nvd – Published: 2026-04-20 03:18 – Updated: 2026-04-20 13:57
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in packet data processing of sx_smpd. Processing a crafted packet may cause a temporary denial-of-service (DoS) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based buffer overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32961",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:57:49.945676Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:57:57.283Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in packet data processing of sx_smpd. Processing a crafted packet may cause a temporary denial-of-service (DoS) condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based buffer overflow",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:37.055Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32961",
        "datePublished": "2026-04-20T03:18:37.055Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T13:57:57.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32960 (GCVE-0-2026-32960)

    Vulnerability from nvd – Published: 2026-04-20 03:18 – Updated: 2026-04-20 13:57
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a sensitive information in resource not removed before reuse. An attacker may login to the device without knowing the password by sending a crafted packet.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-226 - Sensitive information in resource not removed before reuse
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32960",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:57:04.903633Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:57:13.495Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a sensitive information in resource not removed before reuse.  An attacker may login to the device without knowing the password by sending a crafted packet."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-226",
                  "description": "Sensitive information in resource not removed before reuse",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:47.538Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32960",
        "datePublished": "2026-04-20T03:18:47.538Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T13:57:13.495Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32959 (GCVE-0-2026-32959)

    Vulnerability from nvd – Published: 2026-04-20 03:18 – Updated: 2026-04-20 13:56
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a use of a broken or risky cryptographic algorithm. Information in the traffic may be retrieved via man-in-the-middle attack.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-327 - Use of a broken or risky cryptographic algorithm
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32959",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:56:19.084152Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:56:27.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a use of a broken or risky cryptographic algorithm. Information in the traffic may be retrieved via man-in-the-middle attack."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-327",
                  "description": "Use of a broken or risky cryptographic algorithm",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:56.184Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32959",
        "datePublished": "2026-04-20T03:18:56.184Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:56:27.714Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32958 (GCVE-0-2026-32958)

    Vulnerability from nvd – Published: 2026-04-20 03:19 – Updated: 2026-04-20 13:19
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. use a hard-coded cryptographic key. An administrative user may be directed to apply a fake firmware update.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-321 - Use of hard-coded cryptographic key
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32958",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:19:18.750535Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:19:40.008Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. use a hard-coded cryptographic key. An administrative user may be directed to apply a fake firmware update."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "Use of hard-coded cryptographic key",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:19:16.492Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32958",
        "datePublished": "2026-04-20T03:19:16.492Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:19:40.008Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32957 (GCVE-0-2026-32957)

    Vulnerability from nvd – Published: 2026-04-20 03:19 – Updated: 2026-04-20 13:36
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue on firmware maintenance. Arbitrary file may be uploaded on the device without authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32957",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:19:59.658698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:36:04.975Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue on firmware maintenance. Arbitrary file may be uploaded on the device without authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing authentication for critical function",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:19:35.581Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32957",
        "datePublished": "2026-04-20T03:19:35.581Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:36:04.975Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32956 (GCVE-0-2026-32956)

    Vulnerability from nvd – Published: 2026-04-20 03:20 – Updated: 2026-04-20 13:36
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based buffer overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32956",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:20:29.854302Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:36:04.476Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based buffer overflow",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:20:01.225Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32956",
        "datePublished": "2026-04-20T03:20:01.225Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:36:04.476Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32955 (GCVE-0-2026-32955)

    Vulnerability from nvd – Published: 2026-04-20 03:19 – Updated: 2026-04-20 13:36
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a stack-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based buffer overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32955",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:20:14.696625Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:36:04.747Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a stack-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based buffer overflow",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:19:47.937Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32955",
        "datePublished": "2026-04-20T03:19:47.937Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:36:04.747Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32956 (GCVE-0-2026-32956)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:20 – Updated: 2026-04-20 13:36
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based buffer overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32956",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:20:29.854302Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:36:04.476Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based buffer overflow",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:20:01.225Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32956",
        "datePublished": "2026-04-20T03:20:01.225Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:36:04.476Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32955 (GCVE-0-2026-32955)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:19 – Updated: 2026-04-20 13:36
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a stack-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based buffer overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32955",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:20:14.696625Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:36:04.747Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a stack-based buffer overflow vulnerability in processing the redirect URLs. Arbitrary code may be executed on the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based buffer overflow",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:19:47.937Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32955",
        "datePublished": "2026-04-20T03:19:47.937Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:36:04.747Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32957 (GCVE-0-2026-32957)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:19 – Updated: 2026-04-20 13:36
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue on firmware maintenance. Arbitrary file may be uploaded on the device without authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32957",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:19:59.658698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:36:04.975Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue on firmware maintenance. Arbitrary file may be uploaded on the device without authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing authentication for critical function",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:19:35.581Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32957",
        "datePublished": "2026-04-20T03:19:35.581Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:36:04.975Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32958 (GCVE-0-2026-32958)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:19 – Updated: 2026-04-20 13:19
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. use a hard-coded cryptographic key. An administrative user may be directed to apply a fake firmware update.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-321 - Use of hard-coded cryptographic key
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32958",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:19:18.750535Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:19:40.008Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. use a hard-coded cryptographic key. An administrative user may be directed to apply a fake firmware update."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "Use of hard-coded cryptographic key",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:19:16.492Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32958",
        "datePublished": "2026-04-20T03:19:16.492Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:19:40.008Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32959 (GCVE-0-2026-32959)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:18 – Updated: 2026-04-20 13:56
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a use of a broken or risky cryptographic algorithm. Information in the traffic may be retrieved via man-in-the-middle attack.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-327 - Use of a broken or risky cryptographic algorithm
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32959",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:56:19.084152Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:56:27.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a use of a broken or risky cryptographic algorithm. Information in the traffic may be retrieved via man-in-the-middle attack."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-327",
                  "description": "Use of a broken or risky cryptographic algorithm",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:56.184Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32959",
        "datePublished": "2026-04-20T03:18:56.184Z",
        "dateReserved": "2026-03-17T00:23:24.980Z",
        "dateUpdated": "2026-04-20T13:56:27.714Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32960 (GCVE-0-2026-32960)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:18 – Updated: 2026-04-20 13:57
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a sensitive information in resource not removed before reuse. An attacker may login to the device without knowing the password by sending a crafted packet.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-226 - Sensitive information in resource not removed before reuse
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32960",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:57:04.903633Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:57:13.495Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain an issue with a sensitive information in resource not removed before reuse.  An attacker may login to the device without knowing the password by sending a crafted packet."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-226",
                  "description": "Sensitive information in resource not removed before reuse",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:47.538Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32960",
        "datePublished": "2026-04-20T03:18:47.538Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T13:57:13.495Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32961 (GCVE-0-2026-32961)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:18 – Updated: 2026-04-20 13:57
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in packet data processing of sx_smpd. Processing a crafted packet may cause a temporary denial-of-service (DoS) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based buffer overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32961",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T13:57:49.945676Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T13:57:57.283Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a heap-based buffer overflow vulnerability in packet data processing of sx_smpd. Processing a crafted packet may cause a temporary denial-of-service (DoS) condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based buffer overflow",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:37.055Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32961",
        "datePublished": "2026-04-20T03:18:37.055Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T13:57:57.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32962 (GCVE-0-2026-32962)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:18 – Updated: 2026-04-20 14:52
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue. The device configuration may be altered without authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32962",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:52:08.258698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:52:15.598Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a missing authentication for critical function issue. The device configuration may be altered without authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing authentication for critical function",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:25.122Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32962",
        "datePublished": "2026-04-20T03:18:25.122Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:52:15.598Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32963 (GCVE-0-2026-32963)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:18 – Updated: 2026-04-20 14:04
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain a reflected cross-site scripting vulnerability. When a user logs in to the affected device and access some crafted web page, arbitrary script may be executed on the user's browser.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Cross-site scripting (XSS)
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32963",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:04:14.460369Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:04:22.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain a reflected cross-site scripting vulnerability. When a user logs in to the affected device and access some crafted web page, arbitrary script may be executed on the user\u0027s browser."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Cross-site scripting (XSS)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:18:07.431Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32963",
        "datePublished": "2026-04-20T03:18:07.431Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:04:22.838Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32964 (GCVE-0-2026-32964)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:17 – Updated: 2026-04-20 14:08
    VLAI
    Summary
    SD-330AC and AMC Manager provided by silex technology, Inc. contain an improper neutralization of CRLF sequences ('CRLF Injection') vulnerability. Processing some crafted configuration data may lead to arbitrary entries injected to the system configuration.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-93 - Improper neutralization of CRLF sequences ('CRLF Injection')
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32964",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:08:43.843940Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:08:52.559Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SD-330AC and AMC Manager provided by silex technology, Inc. contain an improper neutralization of CRLF sequences (\u0027CRLF Injection\u0027) vulnerability. Processing some crafted configuration data may lead to arbitrary entries injected to the system configuration."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-93",
                  "description": "Improper neutralization of CRLF sequences (\u0027CRLF Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:17:52.839Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32964",
        "datePublished": "2026-04-20T03:17:52.839Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:08:52.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32965 (GCVE-0-2026-32965)

    Vulnerability from cvelistv5 – Published: 2026-04-20 03:17 – Updated: 2026-04-20 14:23
    VLAI
    Summary
    Initialization of a resource with an insecure default vulnerability exists in SD-330AC and AMC Manager provided by silex technology, Inc. When the affected device is connected to the network with the initial (factory-default) configuration, the device can be configured with the null string password.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1188 - Initialization of a resource with an insecure default
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32965",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-20T14:23:30.435627Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-20T14:23:36.842Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD-330AC",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.42 and earlier"
                }
              ]
            },
            {
              "product": "AMC Manager",
              "vendor": "silex technology, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.5.0.2 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Initialization of a resource with an insecure default vulnerability exists in SD-330AC and AMC Manager provided by silex technology, Inc. When the affected device is connected to the network with the initial (factory-default) configuration, the device can be configured with the null string password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1188",
                  "description": "Initialization of a resource with an insecure default",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-20T03:17:33.917Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.silex.jp/support/security-advisories/en/2026-001"
            },
            {
              "url": "https://www.silex.jp/support/security-advisories/2026-001"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94271449/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-32965",
        "datePublished": "2026-04-20T03:17:33.917Z",
        "dateReserved": "2026-03-17T00:23:24.981Z",
        "dateUpdated": "2026-04-20T14:23:36.842Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-201805-1044

    Vulnerability from variot - Updated: 2023-12-18 14:01

    In Silex SX-500 all versions and GE MobileLink(GEH-500) version 1.54 and prior, authentication is not verified when making certain POST requests, which may allow attackers to modify system settings. Silex SX-500 and GE MobileLink(GEH-500) Contains an authentication vulnerability.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. Silex SD-320AN is a serial port device server produced by Silex Technology Company of Japan. GE MobileLink (GEH-500) is an electrocardiogram analysis system developed by General Electric (GE). There is a security vulnerability in Silex SX-500 and GE MobileLink (GEH-500) 1.54 and earlier versions. The vulnerability is caused by the program not performing authentication on POST requests. An attacker could exploit this vulnerability to change system settings

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201805-1044",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sx-500",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "silextechnology",
            "version": null
          },
          {
            "model": "geh-500",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "silextechnology",
            "version": "1.54"
          },
          {
            "model": "geh-sd-320an",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "silextechnology",
            "version": "geh-1.1"
          },
          {
            "model": "sd-320an",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "silextechnology",
            "version": "2.01"
          },
          {
            "model": "geh-500",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "silex",
            "version": "1.54"
          },
          {
            "model": "geh-sd-320an",
            "scope": null,
            "trust": 0.8,
            "vendor": "silex",
            "version": null
          },
          {
            "model": "sd-320an",
            "scope": null,
            "trust": 0.8,
            "vendor": "silex",
            "version": null
          },
          {
            "model": "sx-500",
            "scope": null,
            "trust": 0.8,
            "vendor": "silex",
            "version": null
          },
          {
            "model": "geh-500",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "silextechnology",
            "version": "1.54"
          },
          {
            "model": "sd-320an",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "silextechnology",
            "version": "2.01"
          },
          {
            "model": "geh-sd-320an",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "silextechnology",
            "version": "geh-1.1"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:silextechnology:sd-320an_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "2.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:silextechnology:sd-320an:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:silextechnology:geh-sd-320an_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "geh-1.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:silextechnology:geh-sd-320an:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:silextechnology:geh-500_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.54",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:silextechnology:geh-500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:silextechnology:sx-500_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:silextechnology:sx-500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          }
        ]
      },
      "cve": "CVE-2018-6020",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.4,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 6.4,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2018-6020",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.4,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-136052",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 2.5,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "Low",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2018-6020",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-6020",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201805-234",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-136052",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Silex SX-500 all versions and GE MobileLink(GEH-500) version 1.54 and prior, authentication is not verified when making certain POST requests, which may allow attackers to modify system settings. Silex SX-500 and GE MobileLink(GEH-500) Contains an authentication vulnerability.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. Silex SD-320AN is a serial port device server produced by Silex Technology Company of Japan. GE MobileLink (GEH-500) is an electrocardiogram analysis system developed by General Electric (GE). There is a security vulnerability in Silex SX-500 and GE MobileLink (GEH-500) 1.54 and earlier versions. The vulnerability is caused by the program not performing authentication on POST requests. An attacker could exploit this vulnerability to change system settings",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-6020",
            "trust": 2.5
          },
          {
            "db": "ICS CERT",
            "id": "ICSMA-18-128-01",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-136052",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "id": "VAR-201805-1044",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          }
        ],
        "trust": 0.7666666999999999
      },
      "last_update_date": "2023-12-18T14:01:13.354000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "http://www.silex.jp/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-287",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://ics-cert.us-cert.gov/advisories/icsma-18-128-01"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-6020"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-6020"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "date": "2018-06-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "date": "2018-05-09T21:29:00.213000",
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "date": "2018-05-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-13T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136052"
          },
          {
            "date": "2018-06-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          },
          {
            "date": "2018-06-13T14:14:16.177000",
            "db": "NVD",
            "id": "CVE-2018-6020"
          },
          {
            "date": "2018-05-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Silex SX-500 and  GE MobileLink Authentication vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004824"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-234"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201805-1045

    Vulnerability from variot - Updated: 2023-12-18 14:01

    Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution. Silex SD-320AN and GE MobileLink (GEH-SD-320AN) Is OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Silex SD-320AN is a serial device server from Japan's Silex Technology Corporation. GE MobileLink (GEH-SD-320AN) is a set of electrocardiogram analysis system of General Electric (GE). A remote attacker could use this vulnerability to execute code. The vulnerability stems from the fact that the program does not have correct filtering system call parameters

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201805-1045",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "geh-sd-320an",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "silextechnology",
            "version": "geh-1.1"
          },
          {
            "model": "sd-320an",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "silextechnology",
            "version": "2.01"
          },
          {
            "model": "geh-sd-320an",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "silex",
            "version": "1.1"
          },
          {
            "model": "sd-320an",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "silex",
            "version": "2.01"
          },
          {
            "model": "sd-320an",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "silex",
            "version": "\u003c=2.01"
          },
          {
            "model": "mobilelink \u003c=geh-1.1",
            "scope": null,
            "trust": 0.6,
            "vendor": "ge",
            "version": null
          },
          {
            "model": "sd-320an",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "silextechnology",
            "version": "2.01"
          },
          {
            "model": "geh-sd-320an",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "silextechnology",
            "version": "geh-1.1"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:silextechnology:sd-320an_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "2.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:silextechnology:sd-320an:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:silextechnology:geh-sd-320an_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "geh-1.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:silextechnology:geh-sd-320an:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          }
        ]
      },
      "cve": "CVE-2018-6021",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2018-6021",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2018-09554",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "VHN-136053",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "LOW",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.1,
                "impactScore": 3.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "Low",
                "baseScore": 7.4,
                "baseSeverity": "High",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2018-6021",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "Low",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-6021",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-09554",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201805-233",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-136053",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution. Silex SD-320AN and GE MobileLink (GEH-SD-320AN) Is OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Silex SD-320AN is a serial device server from Japan\u0027s Silex Technology Corporation. GE MobileLink (GEH-SD-320AN) is a set of electrocardiogram analysis system of General Electric (GE). A remote attacker could use this vulnerability to execute code. The vulnerability stems from the fact that the program does not have correct filtering system call parameters",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "ICS CERT",
            "id": "ICSMA-18-128-01",
            "trust": 3.1
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "id": "VAR-201805-1045",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          }
        ],
        "trust": 1.53333335
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          }
        ]
      },
      "last_update_date": "2023-12-18T14:01:13.321000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "http://www.silex.jp/"
          },
          {
            "title": "Patch for Silex SD-320AN and GE MobileLink Remote Code Execution Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/129203"
          },
          {
            "title": "Silex SD-320AN  and GE MobileLink Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79912"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://ics-cert.us-cert.gov/advisories/icsma-18-128-01"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-6021"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-6021"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "date": "2018-05-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "date": "2018-06-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "date": "2018-05-09T21:29:00.277000",
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "date": "2018-05-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-09554"
          },
          {
            "date": "2018-06-13T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136053"
          },
          {
            "date": "2018-06-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          },
          {
            "date": "2018-06-13T14:25:35.437000",
            "db": "NVD",
            "id": "CVE-2018-6021"
          },
          {
            "date": "2018-05-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Silex SD-320AN and  GE MobileLink In  OS Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004825"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-233"
          }
        ],
        "trust": 0.6
      }
    }