Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    14 vulnerabilities by Mennekes

    CVE-2026-8980 (GCVE-0-2026-8980)

    Vulnerability from nvd – Published: 2026-05-28 13:12 – Updated: 2026-05-28 14:22
    VLAI
    Title
    Privilege Escalation
    Summary
    The Mennekes Amtron series (firmware versions ≤ 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    Impacted products
    Vendor Product Version
    Mennekes Amtron Affected: 0 , ≤ 5.22.3 (custom)
    Create a notification for this product.
    Credits
    S. Eisenreich-Dietz (CyberDanube)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-8980",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T14:21:57.909920Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T14:22:21.131Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Amtron",
              "vendor": "Mennekes",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "5.33.11-21500",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "5.22.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "S. Eisenreich-Dietz (CyberDanube)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests.\u003c/p\u003e"
                }
              ],
              "value": "The Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-28T13:12:34.223Z",
            "orgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
            "shortName": "CyberDanube"
          },
          "references": [
            {
              "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Privilege Escalation",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
        "assignerShortName": "CyberDanube",
        "cveId": "CVE-2026-8980",
        "datePublished": "2026-05-28T13:12:34.223Z",
        "dateReserved": "2026-05-19T13:11:29.613Z",
        "dateUpdated": "2026-05-28T14:22:21.131Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-8979 (GCVE-0-2026-8979)

    Vulnerability from nvd – Published: 2026-05-28 13:05 – Updated: 2026-05-28 14:21
    VLAI
    Title
    Authentication Bypass
    Summary
    The Mennekes Amtron series (firmware versions ≤ 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    Mennekes Amtron Affected: 0 , ≤ 5.22.3 (custom)
    Create a notification for this product.
    Credits
    S. Eisenreich-Dietz (CyberDanube)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-8979",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T14:21:09.524366Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T14:21:33.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Amtron",
              "vendor": "Mennekes",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "5.33.11-21500",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "5.22.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "S. Eisenreich-Dietz (CyberDanube)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint.\u003c/p\u003e"
                }
              ],
              "value": "The Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-28T13:15:22.499Z",
            "orgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
            "shortName": "CyberDanube"
          },
          "references": [
            {
              "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Authentication Bypass",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
        "assignerShortName": "CyberDanube",
        "cveId": "CVE-2026-8979",
        "datePublished": "2026-05-28T13:05:40.423Z",
        "dateReserved": "2026-05-19T13:11:28.172Z",
        "dateUpdated": "2026-05-28T14:21:33.159Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-22370 (GCVE-0-2025-22370)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, SQL Injection in web configuration interface
    Summary
    Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22370",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:05.010221Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:11.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:46.281Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22370"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, SQL Injection in web configuration interface",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22370",
        "datePublished": "2025-03-11T13:40:22.946Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:46.281Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22369 (GCVE-0-2025-22369)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint
    Summary
    The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-552 - Files or Directories Accessible to External Parties
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22369",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:52:14.627801Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:52:22.813Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-597",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-597 Absolute Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or Directories Accessible to External Parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.988Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22369"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22369",
        "datePublished": "2025-03-11T13:40:24.403Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:47.988Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22368 (GCVE-0-2025-22368)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in sCU firmware update
    Summary
    The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22368",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:42.139099Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:48.901Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:45.140Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22368"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in sCU firmware update",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22368",
        "datePublished": "2025-03-11T13:40:22.216Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:45.140Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22367 (GCVE-0-2025-22367)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in time setting
    Summary
    The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T19:23:05.314995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T19:23:24.531Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:44.127Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22367"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in time setting",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22367",
        "datePublished": "2025-03-11T13:40:21.388Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:44.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22366 (GCVE-0-2025-22366)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in firmware upgrade
    Summary
    The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22366",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:53:28.425309Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:53:56.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.110Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22366"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in firmware upgrade",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22366",
        "datePublished": "2025-03-11T13:40:23.659Z",
        "dateReserved": "2025-01-03T14:56:05.685Z",
        "dateUpdated": "2025-04-01T04:47:47.110Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-8980 (GCVE-0-2026-8980)

    Vulnerability from cvelistv5 – Published: 2026-05-28 13:12 – Updated: 2026-05-28 14:22
    VLAI
    Title
    Privilege Escalation
    Summary
    The Mennekes Amtron series (firmware versions ≤ 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    Impacted products
    Vendor Product Version
    Mennekes Amtron Affected: 0 , ≤ 5.22.3 (custom)
    Create a notification for this product.
    Credits
    S. Eisenreich-Dietz (CyberDanube)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-8980",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T14:21:57.909920Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T14:22:21.131Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Amtron",
              "vendor": "Mennekes",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "5.33.11-21500",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "5.22.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "S. Eisenreich-Dietz (CyberDanube)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests.\u003c/p\u003e"
                }
              ],
              "value": "The Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-28T13:12:34.223Z",
            "orgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
            "shortName": "CyberDanube"
          },
          "references": [
            {
              "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Privilege Escalation",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
        "assignerShortName": "CyberDanube",
        "cveId": "CVE-2026-8980",
        "datePublished": "2026-05-28T13:12:34.223Z",
        "dateReserved": "2026-05-19T13:11:29.613Z",
        "dateUpdated": "2026-05-28T14:22:21.131Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-8979 (GCVE-0-2026-8979)

    Vulnerability from cvelistv5 – Published: 2026-05-28 13:05 – Updated: 2026-05-28 14:21
    VLAI
    Title
    Authentication Bypass
    Summary
    The Mennekes Amtron series (firmware versions ≤ 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    Mennekes Amtron Affected: 0 , ≤ 5.22.3 (custom)
    Create a notification for this product.
    Credits
    S. Eisenreich-Dietz (CyberDanube)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-8979",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T14:21:09.524366Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T14:21:33.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Amtron",
              "vendor": "Mennekes",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "5.33.11-21500",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "5.22.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "S. Eisenreich-Dietz (CyberDanube)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint.\u003c/p\u003e"
                }
              ],
              "value": "The Mennekes Amtron series (firmware versions \u2264 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-28T13:15:22.499Z",
            "orgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
            "shortName": "CyberDanube"
          },
          "references": [
            {
              "url": "https://cyberdanube.com/security-research/multiple-vulnerabilities-in-mennekes-amtron-series/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Authentication Bypass",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
        "assignerShortName": "CyberDanube",
        "cveId": "CVE-2026-8979",
        "datePublished": "2026-05-28T13:05:40.423Z",
        "dateReserved": "2026-05-19T13:11:28.172Z",
        "dateUpdated": "2026-05-28T14:21:33.159Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-22369 (GCVE-0-2025-22369)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint
    Summary
    The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-552 - Files or Directories Accessible to External Parties
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22369",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:52:14.627801Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:52:22.813Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-597",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-597 Absolute Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or Directories Accessible to External Parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.988Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22369"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22369",
        "datePublished": "2025-03-11T13:40:24.403Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:47.988Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22366 (GCVE-0-2025-22366)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in firmware upgrade
    Summary
    The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22366",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:53:28.425309Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:53:56.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.110Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22366"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in firmware upgrade",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22366",
        "datePublished": "2025-03-11T13:40:23.659Z",
        "dateReserved": "2025-01-03T14:56:05.685Z",
        "dateUpdated": "2025-04-01T04:47:47.110Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22370 (GCVE-0-2025-22370)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, SQL Injection in web configuration interface
    Summary
    Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22370",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:05.010221Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:11.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:46.281Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22370"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, SQL Injection in web configuration interface",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22370",
        "datePublished": "2025-03-11T13:40:22.946Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:46.281Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22368 (GCVE-0-2025-22368)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in sCU firmware update
    Summary
    The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22368",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:42.139099Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:48.901Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:45.140Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22368"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in sCU firmware update",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22368",
        "datePublished": "2025-03-11T13:40:22.216Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:45.140Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22367 (GCVE-0-2025-22367)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in time setting
    Summary
    The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T19:23:05.314995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T19:23:24.531Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:44.127Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22367"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in time setting",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22367",
        "datePublished": "2025-03-11T13:40:21.388Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:44.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }