CWE-941
Incorrectly Specified Destination in a Communication Channel
The product creates a communication channel to initiate an outgoing request to an actor, but it does not correctly specify the intended destination for that actor.
CVE-2025-0036 (GCVE-0-2025-0036)
Vulnerability from cvelistv5
Published
2025-06-09 23:57
Modified
2025-06-30 14:48
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-682 - Incorrect Calculation
- CWE-772 - Missing Release of Resource after Effective Lifetime
- CWE-940 - Improper Verification of Source of a Communication Channel
- CWE-941 - Incorrectly Specified Destination in a Communication Channel
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Summary
In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| AMD | Versal Adaptive SoC Devices |
Patch: 2025.1 release |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0036",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:19:45.871057Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:27:43.315Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Versal Adaptive SoC Devices",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal RF Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal AI Edge Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal Prime Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal Premium Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal AI Core Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Versal HBM Series",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
},
{
"defaultStatus": "affected",
"product": "Alveo V80 Compute Accelerator",
"vendor": "AMD",
"versions": [
{
"status": "unaffected",
"version": "2025.1 release"
}
]
}
],
"datePublic": "2025-06-03T16:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.\u003cbr\u003e"
}
],
"value": "In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.2,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-682",
"description": "CWE-682 Incorrect Calculation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-772",
"description": "CWE-772 Missing Release of Resource after Effective Lifetime",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-941",
"description": "CWE-941 Incorrectly Specified Destination in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T14:48:59.255Z",
"orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
"shortName": "AMD"
},
"references": [
{
"url": "https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8011.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
"assignerShortName": "AMD",
"cveId": "CVE-2025-0036",
"datePublished": "2025-06-09T23:57:39.748Z",
"dateReserved": "2024-11-21T16:18:02.918Z",
"dateUpdated": "2025-06-30T14:48:59.255Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.