var-202405-0154
Vulnerability from variot
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing. SIMATIC RTLS Locating Manager is used to configure, operate, and maintain SIMATIC RTLS devices, which is a real-time wireless location system that provides location solutions.
Siemens SIMATIC RTLS Locating Manager has an insufficient data authenticity verification vulnerability, which is due to the affected component failing to properly verify the heartbeat message
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0154", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic rtls locating manager", "scope": "lt", "trust": 4.2, "vendor": "siemens", "version": "v3.0.1.1" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" } ] }, "cve": "CVE-2024-33494", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2024-23117", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2024-33494", "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2024-33494", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2024-23117", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" }, { "db": "NVD", "id": "CVE-2024-33494" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing. SIMATIC RTLS Locating Manager is used to configure, operate, and maintain SIMATIC RTLS devices, which is a real-time wireless location system that provides location solutions. \n\nSiemens SIMATIC RTLS Locating Manager has an insufficient data authenticity verification vulnerability, which is due to the affected component failing to properly verify the heartbeat message", "sources": [ { "db": "NVD", "id": "CVE-2024-33494" }, { "db": "CNVD", "id": "CNVD-2024-23117" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-093430", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2024-33494", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-23117", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" }, { "db": "NVD", "id": "CVE-2024-33494" } ] }, "id": "VAR-202405-0154", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" } ], "trust": 0.95 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" } ] }, "last_update_date": "2024-08-14T13:41:07.069000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SIMATIC RTLS Locating Manager Insufficient Data Authenticity Verification Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/546781" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-345", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-33494" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" }, { "db": "NVD", "id": "CVE-2024-33494" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23117" }, { "db": "NVD", "id": "CVE-2024-33494" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23117" }, { "date": "2024-05-14T16:17:17.983000", "db": "NVD", "id": "CVE-2024-33494" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23117" }, { "date": "2024-06-11T12:15:15.330000", "db": "NVD", "id": "CVE-2024-33494" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC RTLS Locating Manager Insufficient Data Authenticity Verification Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23117" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.