var-202202-0243
Vulnerability from variot

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior). This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSDataServer process, which listens on TCP port 12401 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose information from the IGSS application. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Supervisory Control System) systems used by Schneider Electric in France to monitor and control industrial processes

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202202-0243",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "interactive graphical scada system data server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "15.0.0.22020"
      },
      {
        "model": "igss data server",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "igss data server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "15.0.0.22020  and earlier"
      },
      {
        "model": "igss",
        "scope": null,
        "trust": 0.7,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "electric interactive graphical scada system",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "\u003c=15.0.0.22020"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vyacheslav Moskvin",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      }
    ],
    "trust": 1.3
  },
  "cve": "CVE-2022-24317",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-24317",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-13072",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-24317",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-24317",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "ZDI",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-24317",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "NONE",
            "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-24317",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-24317",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2022-24317",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-13072",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202202-917",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior). This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSDataServer process, which listens on TCP port 12401 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose information from the IGSS application. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Supervisory Control System) systems used by Schneider Electric in France to monitor and control industrial processes",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-24317",
        "trust": 4.5
      },
      {
        "db": "ZDI",
        "id": "ZDI-22-324",
        "trust": 3.1
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2022-039-01",
        "trust": 2.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-046-01",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU96061299",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-15193",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.0676",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2022021405",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "id": "VAR-202202-0243",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      }
    ],
    "trust": 1.3829545300000001
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:50:42.743000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SEVD-2022-039-01",
        "trust": 0.8,
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01"
      },
      {
        "title": "",
        "trust": 0.7,
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01https://www.cisa.gov/uscert/ics/advisories/icsa-22-046-01"
      },
      {
        "title": "Patch for Schneider Electric Interactive Graphical SCADA System Authorization Issue Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/321161"
      },
      {
        "title": "Schneider Electric Interactive Graphical SCADA System Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=182724"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-862",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of authentication (CWE-862) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-22-324/"
      },
      {
        "trust": 2.2,
        "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-24317"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu96061299/"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-046-01"
      },
      {
        "trust": 0.7,
        "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-01https://www.cisa.gov/uscert/ics/advisories/icsa-22-046-01"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022021405"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-046-01"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.0676"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-02-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "date": "2022-02-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "date": "2023-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "date": "2022-02-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      },
      {
        "date": "2022-02-09T23:15:19.990000",
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-20T00:00:00",
        "db": "ZDI",
        "id": "ZDI-22-324"
      },
      {
        "date": "2022-02-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-13072"
      },
      {
        "date": "2023-05-29T00:04:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      },
      {
        "date": "2024-11-21T06:50:09.527000",
        "db": "NVD",
        "id": "CVE-2022-24317"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Interactive\u00a0Graphical\u00a0SCADA\u00a0System\u00a0Data\u00a0Server\u00a0 Vulnerability regarding lack of authentication in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005333"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-917"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…