var-201904-0174
Vulnerability from variot
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. Attackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0174", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinamics s210", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "5.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-plcsim advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic ipc diagmonitor", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1.3" }, { "model": "simatic s7-1500s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.3" }, { "model": "sinamics gm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic cp443-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sitop manager", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "cp1604", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sitop psu8600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic cp443-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v eip", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.3" }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-400 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sitop ups1600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics sm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic rf182c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf600r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.1" }, { "model": "cp1616", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf185c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic rf186c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-1500t", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic rf188c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.6" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic winac rtx", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics sl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic cp443-1 opc ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic rf181-eip", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "tim 1531 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic s7-1500f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic cp343-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics s210", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 1543sp-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic rf185c", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "sinamics s150", "version": "5.1" }, { "model": "simatic winac rtx sp2 all", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "simatic s7-300 cpu family all", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics g130 and g150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf182c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 opc ua", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf188c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf600r", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "cp1604", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "cp1616", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et sp open controller cpu 1515sp pc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200\u003cv2.1.6" }, { "model": "simatic hmi comfort panels 4\" 22\"", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "sinamics s150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s210", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "sinamics s210 sp1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531" }, { "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf181-eip", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf186c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-plcsim advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie basic", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie standard", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "simocode pro pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "sitop manager", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sitop psu8600", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sitop ups1600", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siamtic rf185c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp343-1 advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et sp open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinamics s210", "version": "5.1" }, { "model": "tim irc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15310" }, { "model": "sitop ups1600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop psu8600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop manager", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics s210 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics s120 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s120 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g130 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g130 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "simocode pro pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v0" }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v60" }, { "model": "simatic s7-300 cpu", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 cpu", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf600r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf188c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf186c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf185c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf182c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic ipc diagmonitor", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp900f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp900 mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp700f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp700 mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp400f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp opc ua", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "rfid 181-eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16160" }, { "model": "cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16040" }, { "model": "sinamics s150 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s120 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g150 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g130 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-300 cpu", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v3.x.16" }, { "model": "simatic et200 open controller cpu 1515sp pc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.1.6" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp1604", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp400f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 opc ua", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic ipc diagmonitor", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 plcsim advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop manager", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf600r", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf188c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf186c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp1616", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf182c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf181 eip", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie basic", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie standard", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx 2010", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf185c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v eip", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s210", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop psu8600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop ups1600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "tim 1531 irc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp343 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500t", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 sp open controller cpu 1515sp pc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 sp open controller cpu 1515sp pc2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels", "version": "*" } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp343-1_advanced_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf185c_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003541" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to NCCIC.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 }, "cve": "CVE-2019-6568", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-6568", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-12904", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-158003", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-6568", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-6568", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6568", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-6568", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6568", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-12904", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201904-458", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-158003", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device. \r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. \nAttackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data", "sources": [ { "db": "NVD", "id": "CVE-2019-6568" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "BID", "id": "107842" }, { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "VULHUB", "id": "VHN-158003" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6568", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-19-099-06", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-480230", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-530931", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-227-04", "trust": 1.4 }, { "db": "BID", "id": "107842", "trust": 1.0 }, { "db": "CNNVD", "id": "CNNVD-201904-458", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-12904", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-003541", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3150", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1204.2", "trust": 0.6 }, { "db": "IVD", "id": "A397CC8B-EE17-4FAF-8447-E9EE5F57DD12", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-158003", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "id": "VAR-201904-0174", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" } ], "trust": 1.5998432480392157 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" } ] }, "last_update_date": "2024-11-23T22:25:58.024000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-480230", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "title": "SSA-530931", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "title": "Patches for multiple Siemens product denial of service vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/160237" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=91286" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.1 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158003" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-06" }, { "trust": 2.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-04" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6568" }, { "trust": 0.9, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6568" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3150/" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-06" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-099-06" }, { "trust": 0.6, "url": "https://www.securityfocus.com/bid/107842" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-webserver-28976" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/78710" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-05T00:00:00", "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "date": "2019-05-05T00:00:00", "db": "CNVD", "id": "CNVD-2019-12904" }, { "date": "2019-04-17T00:00:00", "db": "VULHUB", "id": "VHN-158003" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107842" }, { "date": "2019-05-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "date": "2019-04-09T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-458" }, { "date": "2019-04-17T14:29:03.683000", "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-07T00:00:00", "db": "CNVD", "id": "CNVD-2019-12904" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-158003" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107842" }, { "date": "2019-08-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-458" }, { "date": "2024-11-21T04:46:42.773000", "db": "NVD", "id": "CVE-2019-6568" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability related to input validation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003541" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.