ssa-599506
Vulnerability from csaf_siemens
Published
2022-07-12 00:00
Modified
2022-07-12 00:00
Summary
SSA-599506: Command Injection Vulnerability in RUGGEDCOM ROX

Notes

Summary
RUGGEDCOM ROX devices are affected by a command injection vulnerability that could allow an attacker with administrative privileges to gain root access. Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "RUGGEDCOM ROX devices are affected by a command injection vulnerability that could allow an attacker with administrative privileges to gain root access.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-599506: Command Injection Vulnerability in RUGGEDCOM ROX - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-599506: Command Injection Vulnerability in RUGGEDCOM ROX - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-599506.txt"
      },
      {
        "category": "self",
        "summary": "SSA-599506: Command Injection Vulnerability in RUGGEDCOM ROX - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-599506.json"
      }
    ],
    "title": "SSA-599506: Command Injection Vulnerability in RUGGEDCOM ROX",
    "tracking": {
      "current_release_date": "2022-07-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-599506",
      "initial_release_date": "2022-07-12T00:00:00Z",
      "revision_history": [
        {
          "date": "2022-07-12T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX MX5000",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX MX5000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX MX5000RE",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX MX5000RE"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1400",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1400"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1500",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1500"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1501",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1501"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1510",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1510"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1511",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1511"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1512",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1512"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1524",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1524"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX1536",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX1536"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 2.15.1",
                "product": {
                  "name": "RUGGEDCOM ROX RX5000",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM ROX RX5000"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-29560",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V2.15.1 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ],
          "url": "https://support.industry.siemens.com/cs/document/109810800"
        },
        {
          "category": "workaround",
          "details": "Apply the principle of least privileges for accounts configured on the affected devices",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        },
        {
          "category": "workaround",
          "details": "Apply Defense-in-Depth practices to the SSH, Web and NETCONF services on ROX",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "title": "CVE-2022-29560"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…