icsa-21-210-02
Vulnerability from csaf_cisa
Published
2021-07-29 00:00
Modified
2021-07-29 00:00
Summary
Wibu-Systems CodeMeter Runtime
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to read data from the heap of the CodeMeter Runtime network server, or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "organization": "Tenable, Inc", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to read data from the heap of the CodeMeter Runtime network server, or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-675303.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-210-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-210-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-210-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-210-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "category": "external", "summary": "SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-675303.txt" } ], "title": "Wibu-Systems CodeMeter Runtime", "tracking": { "current_release_date": "2021-07-29T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-210-02", "initial_release_date": "2021-07-29T00:00:00.000000Z", "revision_history": [ { "date": "2021-07-29T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-210-02 WIBU Systems CodeMeter Runtime" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "CAPE 14 installations installed from material dated earlier than 2021-06-16", "product": { "name": "PSS(R)CAPE", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "PSS(R)CAPE" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SICAM 230", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SICAM 230" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 2019 SP1 \u003c 2020 Upd1", "product": { "name": "SIMATIC Information Server", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SIMATIC Information Server" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.1", "product": { "name": "SIMATIC PCS neo", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SIMATIC PCS neo" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 2019 \u003c 2020 Upd1", "product": { "name": "SIMATIC Process Historian (incl. Process Historian OPC UA Server)", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SIMATIC Process Historian (incl. Process Historian OPC UA Server)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.17 P013", "product": { "name": "SIMATIC WinCC OA V3.17", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.17" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.18 P002", "product": { "name": "SIMATIC WinCC OA V3.18", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.18" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= V10.0 \u003c V10.3 Upd 1", "product": { "name": "SIMIT Simulation Platform", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIMIT Simulation Platform" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V1.0.1 Update 1", "product": { "name": "SINEC INS", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SINEC INS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.0 SP2", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-20093", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.\n\nAn unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010" ] }, "references": [ { "summary": "CVE-2021-20093 - SIMATIC WinCC OA V3.17", "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "summary": "CVE-2021-20093 - SIMATIC WinCC OA V3.18", "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "summary": "CVE-2021-20093 - SIMIT Simulation Platform", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800638/" }, { "summary": "CVE-2021-20093 - SINEC INS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109806100/" }, { "summary": "CVE-2021-20093 - SINEMA Remote Connect Server", "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790/" }, { "summary": "CVE-2021-20093 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-20093.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-20093" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "CAPE 14 installations installed from material dated 2021-06-16 or later are not affected, as they contain a fixed version of CodeMeter Runtime.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "If CAPE 14 was initially installed using earlier material, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.psscape.com/codemeter and install it the same way as documented for previous versions in the PSS CAPE 14 Installation Manual. Contact PSS(R)CAPE Support at psscape.support.energy@siemens.com if you need assistance with patching affected systems.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Installations of PSS(R)CAPE are only affected if network access to CodeMeter Runtime is enabled. This is not the default configuration and is not necessary for any functionality in PSS(R)CAPE.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Update SICAM 230 to V8.00 or later version. Then update CodeMeter Runtime to V7.21a or V7.30a: Download the package from: https://www.wibu.com/us/support/user/downloads-user-software.html. Install it on SICAM 230 systems according to the procedure documented in chapter 9.2 of the COPA-DATA Security Vulnerability Announcement 2021_1: https://www.copadata.com/fileadmin/user_upload/faq/files/CD_SVA_2021_1.pdf.", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update SIMATIC PCS neo to V3.1 or later version", "product_ids": [ "CSAFPID-0003", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running.", "product_ids": [ "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V3.17 P013 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "mitigation", "details": "Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running (for details refer to the updated security manual of WinCC OA).", "product_ids": [ "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "vendor_fix", "details": "Update to V3.18 P002 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V10.3 Upd1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800638/" }, { "category": "vendor_fix", "details": "Alternatively, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.wibu.com/us/support/user/downloads-user-software.html and follow the installation instructions from WIBU Systems.", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800638/" }, { "category": "vendor_fix", "details": "Update to V1.0.1 Update 1 or later version", "product_ids": [ "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109806100/" }, { "category": "vendor_fix", "details": "Alternatively, update CodeMeter Runtime to V7.21a: Download the package \"CodeMeter User Runtime for Linux, version 7.21a, Driver-only\" from the WIBU Systems User Software website. Install it on the system which runs SINEC INS by executing the following command:\n\n\"sudo dpkg --force-depends --force-confnew -i codemeter-7.21.4611.501_amd64.deb\"", "product_ids": [ "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109806100/" }, { "category": "mitigation", "details": "Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running. Note that this is the default configuration, which therefore limits the exploitability to local attacks only.", "product_ids": [ "CSAFPID-0009", "CSAFPID-00010" ] }, { "category": "vendor_fix", "details": "Update to V3.0 SP2 or later version", "product_ids": [ "CSAFPID-00010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010" ] } ], "title": "CVE-2021-20093" }, { "cve": "CVE-2021-20094", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.\n\nAn unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-20094 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-20094.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-20094" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "CAPE 14 installations installed from material dated 2021-06-16 or later are not affected, as they contain a fixed version of CodeMeter Runtime.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "If CAPE 14 was initially installed using earlier material, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.psscape.com/codemeter and install it the same way as documented for previous versions in the PSS CAPE 14 Installation Manual. Contact PSS(R)CAPE Support at psscape.support.energy@siemens.com if you need assistance with patching affected systems.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Installations of PSS(R)CAPE are only affected if network access to CodeMeter Runtime is enabled. This is not the default configuration and is not necessary for any functionality in PSS(R)CAPE.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Update SICAM 230 to V8.00 or later version. Then update CodeMeter Runtime to V7.21a or V7.30a: Download the package from: https://www.wibu.com/us/support/user/downloads-user-software.html. Install it on SICAM 230 systems according to the procedure documented in chapter 9.2 of the COPA-DATA Security Vulnerability Announcement 2021_1: https://www.copadata.com/fileadmin/user_upload/faq/files/CD_SVA_2021_1.pdf.", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-20094" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.