icsa-14-329-02d
Vulnerability from csaf_cisa
Published
2014-08-28 06:00
Modified
2025-06-06 22:51
Summary
Siemens SIMATIC WinCC, PCS7, and TIA Portal Vulnerabilities

Notes

Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
        "title": "Recommended Practices"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-14-329-02 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2014/icsa-14-329-02d.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-14-329-02 - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-329-02d"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
      }
    ],
    "title": "Siemens SIMATIC WinCC, PCS7, and TIA Portal Vulnerabilities",
    "tracking": {
      "current_release_date": "2025-06-06T22:51:40.258927Z",
      "generator": {
        "date": "2025-06-06T22:51:40.258866Z",
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-14-329-02D",
      "initial_release_date": "2014-08-28T06:00:00.000000Z",
      "revision_history": [
        {
          "date": "2014-08-28T06:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "Initial Publication"
        },
        {
          "date": "2025-06-06T22:51:40.258927Z",
          "legacy_version": "CSAF Conversion",
          "number": "2",
          "summary": "Advisory converted into a CSAF"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Siemens SIMATIC WinCC V7.0 SP3 and prior: vers:all/*",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V7.0 SP3 and prior"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV7.2_Update_9",
                "product": {
                  "name": "Siemens SIMATIC WinCC  V7.2: \u003cV7.2_Update_9",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC  V7.2"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV7.3_Update_2",
                "product": {
                  "name": "Siemens SIMATIC WinCC V7.3: \u003cV7.3_Update_2",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V7.3"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Siemens SIMATIC PCS 7 V7.1 SP4 and prior: vers:all/*",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS 7 V7.1 SP4 and prior"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV8.0_SP2_with_WinCC_V7.2_Update_9",
                "product": {
                  "name": "Siemens SIMATIC PCS 7 V8.0: \u003cV8.0_SP2_with_WinCC_V7.2_Update_9",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS 7 V8.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cwith_WinCC_V7.3_Update_2",
                "product": {
                  "name": "Siemens SIMATIC PCS 7 V8.1: \u003cwith_WinCC_V7.3_Update_2",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS 7 V8.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV13_Update_6",
                "product": {
                  "name": "Siemens TIA Portal V13 (including WinCC Professional Runtime): \u003cV13_Update_6",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "TIA Portal V13 (including WinCC Professional Runtime)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2014-8551",
      "cwe": {
        "id": "CWE-284",
        "name": "Improper Access Control"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Siemens has released updates for the following products and strongly encourages customers to upgrade to the new versions as soon as possible: TIA Portal V13 (including WinCC Professional Runtime) Upgrade to WinCC V13 Update 6: (http://support.automation.siemens.com/WW/view/de/90527654)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/de/90527654"
        },
        {
          "category": "mitigation",
          "details": "WinCC 7.0 Upgrade to WinCC 7.0 SP2 Update 11: (http://support.automation.siemens.com/WW/view/en/107174184)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/107174184"
        },
        {
          "category": "mitigation",
          "details": "WinCC V7.0 SP3 Upgrade to WinCC 7.0 SP3 Update 7: (http://support.automation.siemens.com/WW/view/en/109253830)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/109253830"
        },
        {
          "category": "mitigation",
          "details": "WinCC 7.2 Upgrade to WinCC 7.2 Update 9: (http://support.automation.siemens.com/WW/view/en/104151435)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/104151435"
        },
        {
          "category": "mitigation",
          "details": "WinCC 7.3  Upgrade to WinCC 7.3 Update 2: (http://support.automation.siemens.com/WW/view/en/105898606)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/105898606"
        },
        {
          "category": "mitigation",
          "details": "PCS 7 V7.1 SP4  Upgrade to WinCC 7.0 SP2 Update 11: (http://support.automation.siemens.com/WW/view/en/107174184)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/107174184"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to OpenPCS 7 V7.1 SP4 Update 1: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to Route Control V7.1 SP2 Update 5: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V7.1 SP1 Update 19: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V7.1 SP2 Update 8: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "PCS 7 V8.0 SP2 Upgrade to WinCC 7.2 Update 9: (http://support.automation.siemens.com/WW/view/en/104151435)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/104151435"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to OpenPCS 7 V8.0 Update 5: (http://support.automation.siemens.com/WW/view/en/106224418)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106224418"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to Route Control V8.0 Update 4: (http://support.automation.siemens.com/WW/view/en/106224418)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106224418"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V8.0 Update 11: (http://support.automation.siemens.com/WW/view/en/106224418)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106224418"
        },
        {
          "category": "mitigation",
          "details": "PCS 7 V8.1  Upgrade to WinCC 7.3 Update 2: (http://support.automation.siemens.com/WW/view/de/105898606)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/de/105898606"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to OpenPCS 7 V8.1 Update 1: (http://support.automation.siemens.com/WW/view/en/106226042)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226042"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to Route Control V8.1 Update 1: (http://support.automation.siemens.com/WW/view/en/106226042)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226042"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V8.1 Update 1: (http://support.automation.siemens.com/WW/view/en/106226042)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226042"
        },
        {
          "category": "mitigation",
          "details": "Until updates can be deployed, Siemens advises customers to mitigate the risk of their products by implementing the following:    Always run WinCC server and engineering stations within a trusted network. Ensure that the WinCC server and the engineering workstations communicate through encrypted channels only (e.g., activate feature \u201cEncrypted Communications\u201d in WinCC V7.3, or establish a VPN tunnel).  Restrict access to the WinCC server to trusted entities.  Apply up-to-date application whitelisting software and virus scanners.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends protecting network access to the SIMATIC WinCC server with appropriate mechanisms. It is also advised to follow recommended security practices and to configure the environment according to operational guidelines in order to run the devices in a protected IT environment.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information on these vulnerabilities and detailed instructions, please see Siemens Security Advisory SSA-134508 at the following location: (http://www.siemens.com/cert/advisories)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://www.siemens.com/cert/advisories"
        }
      ],
      "scores": [
        {
          "cvss_v2": {
            "baseScore": 10.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2014-8552",
      "cwe": {
        "id": "CWE-284",
        "name": "Improper Access Control"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Siemens has released updates for the following products and strongly encourages customers to upgrade to the new versions as soon as possible: TIA Portal V13 (including WinCC Professional Runtime) Upgrade to WinCC V13 Update 6: (http://support.automation.siemens.com/WW/view/de/90527654)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/de/90527654"
        },
        {
          "category": "mitigation",
          "details": "WinCC 7.0 Upgrade to WinCC 7.0 SP2 Update 11: (http://support.automation.siemens.com/WW/view/en/107174184)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/107174184"
        },
        {
          "category": "mitigation",
          "details": "WinCC V7.0 SP3 Upgrade to WinCC 7.0 SP3 Update 7: (http://support.automation.siemens.com/WW/view/en/109253830)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/109253830"
        },
        {
          "category": "mitigation",
          "details": "WinCC 7.2 Upgrade to WinCC 7.2 Update 9: (http://support.automation.siemens.com/WW/view/en/104151435)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/104151435"
        },
        {
          "category": "mitigation",
          "details": "WinCC 7.3  Upgrade to WinCC 7.3 Update 2: (http://support.automation.siemens.com/WW/view/en/105898606)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/105898606"
        },
        {
          "category": "mitigation",
          "details": "PCS 7 V7.1 SP4  Upgrade to WinCC 7.0 SP2 Update 11: (http://support.automation.siemens.com/WW/view/en/107174184)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/107174184"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to OpenPCS 7 V7.1 SP4 Update 1: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to Route Control V7.1 SP2 Update 5: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V7.1 SP1 Update 19: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V7.1 SP2 Update 8: (http://support.automation.siemens.com/WW/view/en/106226043)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226043"
        },
        {
          "category": "mitigation",
          "details": "PCS 7 V8.0 SP2 Upgrade to WinCC 7.2 Update 9: (http://support.automation.siemens.com/WW/view/en/104151435)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/104151435"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to OpenPCS 7 V8.0 Update 5: (http://support.automation.siemens.com/WW/view/en/106224418)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106224418"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to Route Control V8.0 Update 4: (http://support.automation.siemens.com/WW/view/en/106224418)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106224418"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V8.0 Update 11: (http://support.automation.siemens.com/WW/view/en/106224418)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106224418"
        },
        {
          "category": "mitigation",
          "details": "PCS 7 V8.1  Upgrade to WinCC 7.3 Update 2: (http://support.automation.siemens.com/WW/view/de/105898606)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/de/105898606"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to OpenPCS 7 V8.1 Update 1: (http://support.automation.siemens.com/WW/view/en/106226042)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226042"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to Route Control V8.1 Update 1: (http://support.automation.siemens.com/WW/view/en/106226042)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226042"
        },
        {
          "category": "mitigation",
          "details": "Upgrade to BATCH V8.1 Update 1: (http://support.automation.siemens.com/WW/view/en/106226042)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/106226042"
        },
        {
          "category": "mitigation",
          "details": "Until updates can be deployed, Siemens advises customers to mitigate the risk of their products by implementing the following:    Always run WinCC server and engineering stations within a trusted network. Ensure that the WinCC server and the engineering workstations communicate through encrypted channels only (e.g., activate feature \u201cEncrypted Communications\u201d in WinCC V7.3, or establish a VPN tunnel).  Restrict access to the WinCC server to trusted entities.  Apply up-to-date application whitelisting software and virus scanners.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends protecting network access to the SIMATIC WinCC server with appropriate mechanisms. It is also advised to follow recommended security practices and to configure the environment according to operational guidelines in order to run the devices in a protected IT environment.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information on these vulnerabilities and detailed instructions, please see Siemens Security Advisory SSA-134508 at the following location: (http://www.siemens.com/cert/advisories)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "http://www.siemens.com/cert/advisories"
        }
      ],
      "scores": [
        {
          "cvss_v2": {
            "baseScore": 7.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ]
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…