gsd-2024-2560
Vulnerability from gsd
Modified
2024-04-02 05:02
Details
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Aliases



{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2024-2560"
      ],
      "details": "A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
      "id": "GSD-2024-2560",
      "modified": "2024-04-02T05:02:53.365601Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cna@vuldb.com",
        "ID": "CVE-2024-2560",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "AC18",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "15.03.05.05"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Tenda"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "yhryhryhr_backup (VulDB User)"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "deu",
            "value": "In Tenda AC18 15.03.05.05 wurde eine problematische Schwachstelle entdeckt. Hierbei betrifft es die Funktion fromSysToolRestoreSet der Datei /goform/SysToolRestoreSet. Dank der Manipulation mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          },
          {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-352",
                "lang": "eng",
                "value": "CWE-352 Cross-Site Request Forgery"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://vuldb.com/?id.257059",
            "refsource": "MISC",
            "url": "https://vuldb.com/?id.257059"
          },
          {
            "name": "https://vuldb.com/?ctiid.257059",
            "refsource": "MISC",
            "url": "https://vuldb.com/?ctiid.257059"
          },
          {
            "name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolRestoreSet.md",
            "refsource": "MISC",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolRestoreSet.md"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad fue encontrada en Tenda AC18 15.03.05.05 y clasificada como problem\u00e1tica. La funci\u00f3n fromSysToolRestoreSet del archivo /goform/SysToolRestoreSet es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a la Cross-Site Request Forgery. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257059. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-2560",
        "lastModified": "2024-04-11T01:25:28.043",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 1.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-03-17T11:15:06.297",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolRestoreSet.md"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?ctiid.257059"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?id.257059"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-352"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.