A vulnerability has been identified in Siveillance Control (All versions >= V2.8 < V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-45793",
"id": "GSD-2023-45793"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-45793"
],
"details": "A vulnerability has been identified in Siveillance Control (All versions \u003e= V2.8 \u003c V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges.",
"id": "GSD-2023-45793",
"modified": "2023-12-13T01:20:38.198956Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-45793",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Siveillance Control",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V2.8",
"version_value": "V3.1.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Siveillance Control (All versions \u003e= V2.8 \u003c V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-863",
"lang": "eng",
"value": "CWE-863: Incorrect Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/html/ssa-145196.html",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-145196.html"
}
]
}
},
"nvd.nist.gov": {
"cve": {
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Siveillance Control (All versions \u003e= V2.8 \u003c V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Siveillance Control (Todas las versiones \u0026gt;= V2.8 \u0026lt; V3.1.1). El producto afectado no comprueba correctamente la lista de grupos de acceso asignados a un usuario individual. Esto podr\u00eda permitir que un usuario que haya iniciado sesi\u00f3n localmente obtenga privilegios de escritura para objetos donde solo tiene privilegios de lectura."
}
],
"id": "CVE-2023-45793",
"lastModified": "2024-03-12T12:40:13.500",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2024-03-12T11:15:47.503",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-145196.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-863"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…