gsd-2023-44248
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
An improper access control vulnerability [CWE-284] in FortiEDRCollectorWindows version 5.2.0.4549 and below, 5.0.3.1007 and below, 4.0 all may allow a local attacker to prevent the collector service to start in the next system reboot by tampering with some registry keys of the service.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-44248", "id": "GSD-2023-44248" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-44248" ], "details": "An improper access control vulnerability [CWE-284] in\u00a0FortiEDRCollectorWindows version 5.2.0.4549 and below, 5.0.3.1007 and below, 4.0 all may allow a local attacker to prevent the collector service to start in the next system reboot by tampering with some registry keys of the service.", "id": "GSD-2023-44248", "modified": "2023-12-13T01:20:39.020515Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2023-44248", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FortiEDR", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.0.3" }, { "version_affected": "\u003c=", "version_name": "5.0.0", "version_value": "5.0.1" }, { "version_affected": "=", "version_value": "4.0.0" } ] } } ] }, "vendor_name": "Fortinet" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An improper access control vulnerability [CWE-284] in\u00a0FortiEDRCollectorWindows version 5.2.0.4549 and below, 5.0.3.1007 and below, 4.0 all may allow a local attacker to prevent the collector service to start in the next system reboot by tampering with some registry keys of the service." } ] }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:R", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-284", "lang": "eng", "value": "Denial of service" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-23-306", "refsource": "MISC", "url": "https://fortiguard.com/psirt/FG-IR-23-306" } ] }, "solution": [ { "lang": "en", "value": "Please upgrade to FortiEDRCollectorWindows version 5.2.0.4581 or above\nPlease upgrade to FortiEDRCollectorWindows version 5.0.3.1016 or above\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:fortinet:fortiedr:4.0.0:*:*:*:*:windows:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fortinet:fortiedr:*:*:*:*:*:windows:*:*", "cpe_name": [], "versionEndIncluding": "5.2.0.4549", "versionStartIncluding": "5.2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fortinet:fortiedr:*:*:*:*:*:windows:*:*", "cpe_name": [], "versionEndIncluding": "5.0.3.1007", "versionStartIncluding": "5.0.3", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2023-44248" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An improper access control vulnerability [CWE-284] in\u00a0FortiEDRCollectorWindows version 5.2.0.4549 and below, 5.0.3.1007 and below, 4.0 all may allow a local attacker to prevent the collector service to start in the next system reboot by tampering with some registry keys of the service." } ] }, "problemtype": { "problemtype_data": [ { "description": [] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-23-306", "refsource": "", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-23-306" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } }, "lastModifiedDate": "2023-11-21T01:39Z", "publishedDate": "2023-11-14T18:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…