gsd-2023-36635
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2
7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-36635",
"id": "GSD-2023-36635"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-36635"
],
"details": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API.",
"id": "GSD-2023-36635",
"modified": "2023-12-13T01:20:34.183755Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2023-36635",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FortiSwitchManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "7.2.0",
"version_value": "7.2.2"
},
{
"version_affected": "\u003c=",
"version_name": "7.0.0",
"version_value": "7.0.1"
}
]
}
}
]
},
"vendor_name": "Fortinet"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API."
}
]
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H/E:F/RL:X/RC:X",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-284",
"lang": "eng",
"value": "Improper access control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-174",
"refsource": "MISC",
"url": "https://fortiguard.com/psirt/FG-IR-22-174"
}
]
},
"solution": [
{
"lang": "en",
"value": "Please upgrade to FortiOS version 7.2.1 or above\r\nPlease upgrade to FortiOS version 7.0.8 or above\r\nPlease upgrade to FortiSwitchManager version 7.2.2 or above\r\nPlease upgrade to FortiSwitchManager version 7.0.2 or above"
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2023-36635"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-174",
"refsource": "MISC",
"tags": [
"Not Applicable",
"Vendor Advisory"
],
"url": "https://fortiguard.com/psirt/FG-IR-22-174"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4
}
},
"lastModifiedDate": "2023-09-12T14:26Z",
"publishedDate": "2023-09-07T13:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…