{ "GSD": { "alias": "CVE-2023-32736", "id": "GSD-2023-32736" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-32736" ], "id": "GSD-2023-32736", "modified": "2023-12-13T01:20:23.964599Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2023-32736", "STATE": "RESERVED" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." } ] } } } }
cve-2023-32736
Vulnerability from cvelistv5
Published
2024-11-12 12:49
Modified
2024-12-02 20:16
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 Update 5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 Update 5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 8), SIRIUS Safety ES V18 (All versions), SIRIUS Soft Starter ES V17 (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_step_7", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "17_update8", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "18_update5", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_step_7", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "17_update8", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "18_update5", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-plcsim", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "17", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_wincc", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "17_update8", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "18_update5", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_wincc_unified", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "17_update8", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "18_update5", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simocode_es", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "17_update8", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simotion_scout_tia", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "v5.4sp1", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "v5.4sp3", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "v5.5sp1", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_startdrive", "vendor": "siemens", "versions": [ { "lessThan": "17", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "18", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sirius_safety_es", "vendor": "siemens", "versions": [ { "lessThan": "17_update8", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "18", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tia_portal_cloud", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "16", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "17", "versionType": "custom" }, { "lessThan": "*", "status": "affected", "version": "18", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-32736", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-02T19:49:50.974471Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-02T20:16:52.424Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 Safety V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 Safety V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 Safety V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Unified V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Unified V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Unified V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE ES V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE ES V18", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION SCOUT TIA V5.4 SP1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION SCOUT TIA V5.4 SP3", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION SCOUT TIA V5.5 SP1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive V18", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Safety ES V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Safety ES V18", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter ES V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter ES V18", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud V17", "vendor": "Siemens", "versions": [ { "lessThan": "V4.6.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud V18", "vendor": "Siemens", "versions": [ { "lessThan": "V4.6.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Unified V18 (All versions \u003c V18 Update 5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions \u003c V17 Update 8), SIMATIC WinCC V18 (All versions \u003c V18 Update 5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions \u003c V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions \u003c V17 Update 8), SIRIUS Safety ES V18 (All versions), SIRIUS Soft Starter ES V17 (All versions \u003c V17 Update 8), SIRIUS Soft Starter ES V18 (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions \u003c V4.6.0.1), TIA Portal Cloud V18 (All versions \u003c V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502: Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-12T12:49:22.651Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-871035.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-32736", "datePublished": "2024-11-12T12:49:22.651Z", "dateReserved": "2023-05-12T13:16:47.721Z", "dateUpdated": "2024-12-02T20:16:52.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.