gsd-2022-41327
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A cleartext transmission of sensitive information vulnerability [CWE-319] in Fortinet FortiOS version 7.2.0 through 7.2.4, 7.0.0 through 7.0.8, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.8 allows an authenticated attacker with readonly superadmin privileges to intercept traffic in order to obtain other adminstrators cookies via diagnose CLI commands.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-41327", "id": "GSD-2022-41327" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-41327" ], "details": "A cleartext transmission of sensitive information vulnerability [CWE-319] in Fortinet FortiOS version 7.2.0 through 7.2.4, 7.0.0 through 7.0.8, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.8 allows an authenticated attacker with readonly superadmin privileges to intercept traffic in order to obtain other adminstrators cookies via diagnose CLI commands.", "id": "GSD-2022-41327", "modified": "2023-12-13T01:19:32.977695Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2022-41327", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FortiOS", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "7.2.0", "version_value": "7.2.3" }, { "version_affected": "\u003c=", "version_name": "7.0.0", "version_value": "7.0.8" } ] } }, { "product_name": "FortiProxy", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "7.2.0", "version_value": "7.2.1" }, { "version_affected": "\u003c=", "version_name": "7.0.0", "version_value": "7.0.7" } ] } } ] }, "vendor_name": "Fortinet" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A cleartext transmission of sensitive information vulnerability [CWE-319] in Fortinet FortiOS version 7.2.0 through 7.2.4, 7.0.0 through 7.0.8, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.8 allows an authenticated attacker with readonly superadmin privileges to intercept traffic in order to obtain other adminstrators cookies via diagnose CLI commands." } ] }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:X/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-319", "lang": "eng", "value": "Information disclosure" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-22-380", "refsource": "MISC", "url": "https://fortiguard.com/psirt/FG-IR-22-380" } ] }, "solution": [ { "lang": "en", "value": "Please upgrade to FortiOS version 7.2.5 or above\r\nPlease upgrade to FortiOS version 7.0.9 or above\r\nPlease upgrade to FortiProxy version 7.2.2 or above\r\nPlease upgrade to FortiProxy version 7.0.8 or above" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:fortinet:fortiproxy:7.2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "7.0.8", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "7.0.7", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fortinet:fortiproxy:7.2.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "7.2.4", "versionStartIncluding": "7.2.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2022-41327" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A cleartext transmission of sensitive information vulnerability [CWE-319] in Fortinet FortiOS version 7.2.0 through 7.2.4, 7.0.0 through 7.0.8, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.8 allows an authenticated attacker with readonly superadmin privileges to intercept traffic in order to obtain other adminstrators cookies via diagnose CLI commands." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-319" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-22-380", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-22-380" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6 } }, "lastModifiedDate": "2023-06-17T01:37Z", "publishedDate": "2023-06-13T09:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.