gsd-2022-0988
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2022-0988",
    "description": "Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.",
    "id": "GSD-2022-0988"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-0988"
      ],
      "details": "Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.",
      "id": "GSD-2022-0988",
      "modified": "2023-12-13T01:19:11.364528Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "DATE_PUBLIC": "2022-03-22T17:29:00.000Z",
        "ID": "CVE-2022-0988",
        "STATE": "PUBLIC",
        "TITLE": "Delta Electronics DIAEnergie CLEARTEXT Transmission of Sensitive Information"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "DIAEnergie",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_value": "1.7.5"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Delta Electronics"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-319 Cleartext Transmission of Sensitive Information"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-238-03",
            "refsource": "CONFIRM",
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-238-03"
          }
        ]
      },
      "solution": [
        {
          "lang": "eng",
          "value": "Delta Electronics has released an updated version of DIAEnergie and recommends users install v1.8.0 and later on all affected systems."
        }
      ],
      "source": {
        "advisory": "ICSA-21-238-03",
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.7.5",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-0988"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-319"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-238-03",
              "refsource": "CONFIRM",
              "tags": [
                "Mitigation",
                "Patch",
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-238-03"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2022-04-01T12:24Z",
      "publishedDate": "2022-03-25T19:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.