gsd-2021-1586
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2021-1586",
"description": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.",
"id": "GSD-2021-1586"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-1586"
],
"details": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.",
"id": "GSD-2021-1586",
"modified": "2023-12-13T01:23:23.770690Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2021-08-25T16:00:00",
"ID": "CVE-2021-1586",
"STATE": "PUBLIC",
"TITLE": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco NX-OS System Software in ACI Mode ",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition."
}
]
},
"exploit": [
{
"lang": "eng",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
}
],
"impact": {
"cvss": {
"baseScore": "8.6",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H ",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
}
]
},
"source": {
"advisory": "cisco-sa-n9kaci-tcp-dos-YXukt6gM",
"defect": [
[
"CSCvw87983"
]
],
"discovery": "INTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:15.0\\(2e\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:15.1\\(1h\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx3p:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2021-1586"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-345"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
"refsource": "CISCO",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.0
}
},
"lastModifiedDate": "2021-09-02T17:18Z",
"publishedDate": "2021-08-25T20:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…