ghsa-cc9x-2646-xv35
Vulnerability from github
Published
2024-03-12 12:30
Modified
2024-09-10 12:30
Details

A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process.

An attacker with physical access to the device could read out the data.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2024-21483"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-284"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-03-12T11:15:48Z",
    "severity": "MODERATE"
  },
  "details": "A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions \u003e= V3.2.3 \u003c V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions \u003e= V3.2.3 \u003c V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions \u003e= V3.2.3 \u003c V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions \u003e= V3.2.3 \u003c V3.3.0 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process.\n\nAn attacker with physical access to the device could read out the data.",
  "id": "GHSA-cc9x-2646-xv35",
  "modified": "2024-09-10T12:30:35Z",
  "published": "2024-03-12T12:30:48Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-21483"
    },
    {
      "type": "WEB",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-792319.html"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.