A maliciously crafted PDF file, when parsed through certain Autodesk products, can force a Heap-Based Overflow vulnerability. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "08F0B7FF-A0AF-45A6-BCD8-ED3CDF131749",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F07B2E77-DB15-4E63-B6E3-80331CF56B30",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7A50FB1-FF20-4FC4-953E-702576FC487E",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5C0D7FC-F1AC-4882-9B75-EE93182593A4",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F38F358-7F2D-4E71-B546-0DCD04F4DCCD",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "15E833D7-0BF9-4213-ACF6-622CC4BC4D0A",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C746E50-6500-4BD9-B9AD-E58B49163FCC",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9DD3780-1C5F-47EA-BC81-9E679FB3628C",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34E2392F-D068-4AB1-83D8-E70E9F9871F4",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2500CC71-B7D3-412A-AB2B-E9B748A3785E",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCBAABF0-47ED-4AE8-95EF-CA88AC482ED7",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5417086A-F453-4A1E-A151-4D9E5CB9C4EA",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "233064C8-C3E0-4BC7-9289-28E40C5E31A4",
              "versionEndExcluding": "2025.4.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1EA8A6E-9199-42C0-A807-952406DA952C",
              "versionEndExcluding": "2026.3",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66B0B67D-64D6-41F7-AB4B-2653BC51D026",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D50BA86C-8012-4AD8-AA9D-DF41278C5049",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC0479E2-96AB-40F4-B0FA-3A383E7DE66A",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5E9CC04-B5AC-4525-870A-0918AC2AB4AD",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "99B3A33A-99DF-4BB2-8AA4-2960422C9C8C",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "996E5628-78A2-42A3-91E7-E54D814D8068",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8014E1F-EA63-4898-936D-B6945920ADCC",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98BCB2ED-A4C2-49F2-8F56-DC4DC896D343",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7947EDF4-C754-48B0-9270-EEA698E6F048",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C183351D-FF44-49F6-B703-BD186ACDC658",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "16DDAD2E-730B-49A4-8423-8630FF0E7571",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "782C3D4E-8384-4A4E-BDBE-7AFB370B13BA",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA97DB73-C60B-4BA5-97B7-EF1424A203DA",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CC953B9-8AE6-467C-9949-9617DAC9EC0E",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2EBB17CA-9BB5-43C7-ACAF-3F490A9BB5FF",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B7101B-1613-4076-934C-1FA34BBB3D11",
              "versionEndExcluding": "2024.1.8",
              "versionStartIncluding": "2024",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE367F62-0A0A-4102-85A2-E3E57FE61A24",
              "versionEndExcluding": "2025.1.3",
              "versionStartIncluding": "2025",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFCE6B4D-6432-4F5D-9004-B277BF117CD7",
              "versionEndExcluding": "2026.1",
              "versionStartIncluding": "2026",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A maliciously crafted PDF file, when parsed through certain Autodesk products, can force a Heap-Based Overflow vulnerability. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process."
    }
  ],
  "id": "CVE-2025-8894",
  "lastModified": "2025-09-19T13:51:12.743",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "psirt@autodesk.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-09-16T15:15:46.973",
  "references": [
    {
      "source": "psirt@autodesk.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.autodesk.com/products/autodesk-access/overview"
    },
    {
      "source": "psirt@autodesk.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2025-0018"
    }
  ],
  "sourceIdentifier": "psirt@autodesk.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "psirt@autodesk.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…