Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. \n\nThis issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025"
},
{
"lang": "es",
"value": "Medtronic MyCareLink Patient Monitor cuenta con un servicio interno que deserializa datos, lo que permite a un atacante local interactuar con el servicio mediante la manipulado de una carga binaria para bloquearlo o elevar privilegios. Este problema afecta a los modelos 24950 y 24952 de Medtronic MyCareLink Patient Monitor antes del 25 de junio de 2025."
}
],
"id": "CVE-2025-4393",
"lastModified": "2025-07-25T15:29:44.523",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.0,
"impactScore": 5.5,
"source": "security@medtronic.com",
"type": "Secondary"
}
]
},
"published": "2025-07-24T07:15:53.343",
"references": [
{
"source": "security@medtronic.com",
"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins.html"
}
],
"sourceIdentifier": "security@medtronic.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-502"
}
],
"source": "security@medtronic.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…