fkie_cve-2025-27695
Vulnerability from fkie_nvd
Published
2025-05-08 19:16
Modified
2025-07-11 14:08
Severity ?
Summary
Dell Wyse Management Suite, versions prior to WMS 5.1 contain an Authentication Bypass by Spoofing vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information Disclosure.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/en-us/000296515/dsa-2025-135 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | wyse_management_suite | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:wyse_management_suite:*:*:*:*:*:*:*:*",
"matchCriteriaId": "625A4274-8B9A-4A8B-A727-98CC0704BC6F",
"versionEndExcluding": "5.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell Wyse Management Suite, versions prior to WMS 5.1 contain an Authentication Bypass by Spoofing vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information Disclosure."
},
{
"lang": "es",
"value": "Las versiones de Dell Wyse Management Suite anteriores a WMS 5.1 contienen una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n por suplantaci\u00f3n de identidad. Un atacante con privilegios elevados y acceso remoto podr\u00eda explotar esta vulnerabilidad, lo que podr\u00eda provocar una divulgaci\u00f3n de informaci\u00f3n."
}
],
"id": "CVE-2025-27695",
"lastModified": "2025-07-11T14:08:35.500",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
},
"published": "2025-05-08T19:16:02.290",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000296515/dsa-2025-135"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-290"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…