fkie_cve-2024-4242
Vulnerability from fkie_nvd
Published
2024-04-26 21:15
Modified
2025-01-27 18:29
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formwrlSSIDget.md | Broken Link | |
| cna@vuldb.com | https://vuldb.com/?ctiid.262133 | Permissions Required, Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.262133 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?submit.319824 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formwrlSSIDget.md | Broken Link | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.262133 | Permissions Required, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.262133 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.319824 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | w9_firmware | 1.0.0.7\(4456\) | |
| tenda | w9 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:w9_firmware:1.0.0.7\\(4456\\):*:*:*:*:*:*:*",
"matchCriteriaId": "2C2E04EE-4493-4CCB-9EB6-7E0D033920A1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D015C5A3-DF6D-45B7-B669-9CCD50C5E704",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se encontr\u00f3 una vulnerabilidad en Tenda W9 1.0.0.7(4456). Ha sido calificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formwrlSSIDget del archivo /goform/wifiSSIDget. La manipulaci\u00f3n del argumento ssidIndex provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-262133. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2024-4242",
"lastModified": "2025-01-27T18:29:46.497",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-04-26T21:15:50.727",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formwrlSSIDget.md"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.262133"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.262133"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.319824"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formwrlSSIDget.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.262133"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.262133"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.319824"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…